VI 3000 RLP - Inverter PowerWalker - Free user manual and instructions
Find the device manual for free VI 3000 RLP PowerWalker in PDF.
Pick your language and provide your email: we'll send you a specifically translated version.
| Product Type | Uninterruptible Power Supply (UPS) |
| Model | VI 3000 RLP |
| Brand | PowerWalker |
| Power Rating | 3000 VA / 2700 W |
| Form Factor | Rackmount / Tower convertible (2U) |
| Input Voltage | 230 V AC (±10%) |
| Output Voltage | 230 V AC sine wave |
| Frequency | 50/60 Hz (auto-sensing) |
| Waveform | Pure sine wave |
| Battery Type | Sealed lead-acid, maintenance-free |
| Battery Quantity | 2 x 12V (internal pack) |
| Typical Backup Time (half load) | Approx. 15-20 minutes |
| Recharge Time | 4-6 hours to 90% |
| Dimensions (W x D x H) | 482 x 460 x 88 mm (19") |
| Weight | Approx. 30 kg |
| Interfaces | RS-232, USB, SNMP slot (optional) |
| Outlets | 8 x IEC C13 (programmable) |
| Protection Features | Overload, short circuit, surge, low battery, temperature |
| Maintenance | Battery replacement every 3-5 years; fan cleaning annually |
| Safety Standards | CE, TUV, IEC 62040 |
| Operating Temperature | 0°C to 40°C |
| Noise Level | <50 dBA (typical) |
Frequently Asked Questions - VI 3000 RLP PowerWalker
What is the typical backup time for the VI 3000 RLP?
At half load (1350 W), you can expect about 15-20 minutes of runtime. Full load (2700 W) reduces this to around 5-8 minutes.
How do I replace the batteries?
Remove the front panel to access the battery compartment. Unplug the old battery connectors and slide out the old batteries. Insert the new ones (same type: 12V 9Ah recommended) and reconnect. Refer to the manual for safety steps.
Can this UPS be mounted in a rack?
Yes, it is a rackmount/tower convertible design with 2U height. It includes rack ears for 19" racks.
What outlets are available?
It has 8 IEC C13 outlets, some of which may be programmable for load shedding or critical device prioritization.
Does it have surge protection?
Yes, it provides surge protection for connected devices, as well as overload and short circuit protection.
Is software included for monitoring?
Yes, it typically includes PowerWalker UPS monitoring software via USB/RS-232 for graceful shutdown and power management.
What input plug does it use?
It uses a standard IEC C20 inlet for 230V AC. A power cord with a Schuko or other regional plug is provided.
How often should I replace the batteries?
Batteries generally last 3-5 years depending on usage and temperature. Replace them if backup time reduces significantly.
Can the UPS be turned off for storage?
Yes, press the power button to turn off. For long-term storage, charge the batteries every 3-6 months to prevent damage.
Is it compatible with a generator?
Yes, but ensure the generator output is stable (pure sine wave recommended) and within voltage/frequency tolerance of the UPS.
User questions about VI 3000 RLP PowerWalker
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.