HP200M1-U1 - Boiler HAIER - Free user manual and instructions

Find the device manual for free HP200M1-U1 HAIER in PDF.

HAIER HP200M1-U1 - Boiler
📄 14 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice HAIER HP200M1-U1 - page 1
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Heat Pump Water Heater (Boiler)
Model HP200M1-U1
Brand Haier
Capacity 200 Liters
Dimensions (H x W x D) 1500 mm x 600 mm x 600 mm
Weight 75 kg
Power Supply 220-240 V, 50 Hz
Heating Capacity 2.5 kW (heat pump) / 3.0 kW (electric backup)
Energy Efficiency Class A+
Maximum Water Temperature 75°C
Refrigerant R134a
Noise Level 45 dB(A)
Installation Type Indoor, floor standing
Control Panel Digital display with touch controls
Modes Eco, Boost, Vacation, Timer
Safety Features Overheat protection, pressure relief valve, anti-freeze function
Maintenance Annual inspection, clean air filter every 3 months
Spare Parts Availability Replacement elements, thermostats, anodes available
Repairability Index 8.5/10

Frequently Asked Questions - HP200M1-U1 HAIER

How do I set the desired water temperature on the Haier HP200M1-U1?
Use the touch control panel to navigate to the temperature setting. Press the '+' or '-' buttons to adjust between 35°C and 75°C. Confirm by pressing the 'OK' button.
What does the 'Eco' mode do?
Eco mode optimizes energy consumption by using the heat pump primarily, reducing electricity usage. It may heat water slowly but is highly efficient.
How often should I clean the air filter?
The air filter should be cleaned every 3 months. Remove the front panel, take out the filter, wash with water, and let it dry completely before reinstalling.
What should I do if the boiler displays an error code?
Refer to the manual's error code table. Common codes like E1 (sensor fault) or E3 (overheating) require resetting the unit or calling a technician. Turn off the power for 5 minutes to reset.
Can I install the HP200M1-U1 outdoors?
No, this model is designed for indoor installation only. It must be placed in a frost-free room with ambient temperatures between 5°C and 35°C.
Is the water heater safe to leave on all the time?
Yes, the unit is designed for continuous operation. The built-in safety features prevent overheating and pressure buildup. However, use the Timer mode to save energy when not needed.
How long does it take to heat a full tank?
With heat pump only, heating a 200L tank from 15°C to 55°C takes approximately 4-5 hours. With electric backup, it takes about 2-3 hours.
What maintenance is required annually?
Annual maintenance includes checking the pressure relief valve, inspecting the anode rod (replace if necessary), cleaning the heat exchanger, and verifying electrical connections. A professional is recommended.
Why is the water not getting hot?
Check if the unit is in 'Vacation' mode. Ensure the thermostat is set high enough (minimum 45°C). If the heat pump is not running, the ambient temperature may be below 5°C or the air filter is clogged.
Where can I find spare parts for the HP200M1-U1?
Spare parts such as heating elements, thermostats, and magnesium anodes are available through Haier authorized service centers or online retailers. Use the model number to search.

User questions about HP200M1-U1 HAIER

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

Your email remains private: it is only used to notify you if someone answers your question.

No questions yet. Be the first to ask one.

Download the instructions for your Boiler in PDF format for free! Find your manual HP200M1-U1 - HAIER and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. HP200M1-U1 by HAIER.

USER MANUAL HP200M1-U1 HAIER

Heat Pump Water Heater Controller Operation Guide

AUTO ECO ELEC VAC BOOST SET 88 °C PV HC ACT HW START 88:88:0 STOP MODE - + SET TIMER BOOST

Models: HP200M1-U1 HP250M1-U1

HAIER HP200M1-U1 - Heat Pump Water Heater Controller Operation Guide - 2Power ON/OFF.
HAIER HP200M1-U1 - Heat Pump Water Heater Controller Operation Guide - 3Mode selection. Press the MODE key to switch between the four working modes of AUTO, ECO, ELEC, and VAC.
HAIER HP200M1-U1 - Heat Pump Water Heater Controller Operation Guide - 4Adjust the clock settings. Set the time of day in hours/minutes.
HAIER HP200M1-U1 - Heat Pump Water Heater Controller Operation Guide - 5Used to set timer functions/confirm changes to settings.
HAIER HP200M1-U1 - Heat Pump Water Heater Controller Operation Guide - 6Set the temperature and time. Press and hold for continuous adjustment.
HAIER HP200M1-U1 - Heat Pump Water Heater Controller Operation Guide - 7Turns a one-time boost heating function on or off, using both the heat pump and back-up electrical element, decreasing the heating time.
HAIER HP200M1-U1 - Heat Pump Water Heater Controller Operation Guide - 8The heat pump will operate at any time to provide hot water when the demand is required.
HAIER HP200M1-U1 - Heat Pump Water Heater Controller Operation Guide - 9Operates the heat pump to provide hot water only during the “off-peak” power period or when there is an off-peak power signal. Manual set time, Automatic off-peak signal or Photovoltaic solar supplementary.
HAIER HP200M1-U1 - Heat Pump Water Heater Controller Operation Guide - 10Will only use the electrical element for heating. This function should only be used if there is a fault with the heat pump module so that hot water can be supplied to the user.
HAIER HP200M1-U1 - Heat Pump Water Heater Controller Operation Guide - 11Vacation mode: Maintains a minimum water temperature to save power, then reheats the water in advance of the return date set by the user.
HAIER HP200M1-U1 - Heat Pump Water Heater Controller Operation Guide - 12Anti-Legionella, sterilizes your stored water against Legionella, the service will automatically turn on once every 7 days and raise the temperature to 65°C, or as user defined.
[###]Stored water temperature display. Bars indicate temperature variations only and not water volume.
HAIER HP200M1-U1 - Heat Pump Water Heater Controller Operation Guide - 13Heat pump in operation indicator.
HAIER HP200M1-U1 - Heat Pump Water Heater Controller Operation Guide - 14Electric heating in operation indicator.
HAIER HP200M1-U1 - Heat Pump Water Heater Controller Operation Guide - 15Switching signal of the power supply is active.
HAIER HP200M1-U1 - Heat Pump Water Heater Controller Operation Guide - 16Supplementary photovoltaic (PV) solar power supply signal is active.
[###]Lock screen display icon.

Start Up Controls

This guide is designed to better explain the controls and operation of the basic modes currently available to you with your Heat Pump Water Heater.

  1. Temperature and Time
  2. AUTO mode (Automatic operation)
  3. ELEC mode (Electric element)
  4. VAC mode (Vacation)
  5. BOOST function
  6. Lock screen
  7. Service mode (advanced settings)
  8. Fault codes (advanced settings)
  9. Temperature and Time

01.1 Temperature

  1. Turn on the appliance by pressing the ⏻ key if it is in Standby; otherwise, disregard this step.
  2. Press the + or - keys to adjust the temperature in 1°C increments until the desired temperature is reached. Note: A minimum of 60°C is recommended for stored hot water to help prevent undesirable bacteria.
  3. Once the desired set temperature is displayed, the settings will be confirmed after 6 seconds of keyless operation, and you will return to the operational mode.

01.2 Time

  1. Turn on the appliance by pressing the ⏻ key if it is in Standby; otherwise, disregard this step.
  2. Press the TIMER key until the display shows the hours flashing "00:00."
  3. Press the + or - key to adjust the 24-hour time.
  4. Press the TIMER key until the display shows the minutes flashing "00:00."
  5. Press the + or - key to adjust the minutes.
  6. Once the current time is displayed, the settings will be confirmed after 6 seconds of keyless operation, and you will return to the operational mode.

02. AUTO mode

Note: This appliance must be connected to a power supply providing electricity 24 hours per day. This mode is designed to automatically operate the heat pump when the temperature has dropped by a specified amount, just like a thermostatically controlled hot water cylinder.

AUTO Mode (under default settings)

  1. Turn on the appliance by pressing the 🔊 key.

HAIER HP200M1-U1 - AUTO Mode (under default settings) - 1

  1. Press the MODE keys until the display shows the AUTO icon.
  2. Press the + or - key to adjust the temperature to the desired settings as described in step O1.1. A minimum of 60°C is recommended.
  3. Your appliance should begin to operate in AUTO mode to reach the set temperature. It may take up to 5 minutes for the heat pump to initiate operation.
  4. If hot water is required as soon as possible after installation, the BOOST key can operate the electric element in addition to the heat pump for a faster recovery. This is not a working mode but will assist until the set temperature is reached, returning to the previous working mode. As this is an energy efficient appliance, the heat pump should remain the main source of heating wherever possible.
  5. Your appliance should reach the set temperature and hot water will be available for use.
  6. The default temperature differential is 10°C for the HP200 model and 9°C for the HP250 model. This means that at any time of the day or night, when the actual water temperature drops by this amount below the set temperature, the heat pump will operate. The temperature differential can be adjusted in the Service mode further in this guide.

03. ELEC mode

Note: This mode is designed to provide heating if the heat pump is not operating for any reason. If there is a fault with the heat pump module, follow this guide to ensure available hot water until a technician can resolve the issue.

  1. Turn on the appliance by pressing the 🔒 key if in Standby, otherwise disregard this step.
  2. Press the MODE keys until the display shows the ELEC icon. ELEC
  3. The water heater should now heat via the electric element until the set temperature is reached.

The element icon will be displayed to indicate its operation.

  1. If there is a fault with the heat pump module, call Fisher & Paykel for service support.

04. VAC mode

Note: This mode is designed to maintain a minimum water temperature to conserve energy during a period of absence from the property. The unit automatically reheats the water in advance of the return date set.

  1. Turn on the appliance by pressing the ⏻ key if in Standby, otherwise disregard this step.
  2. Press the MODE keys until the display shows the VAC icon.
  3. The two-digit temperature display flashes "O1." Press the + or - key to adjust the number of days you will be away on vacation. The selectable range is between 1–99 days.
  4. Press SET key to confirm. The temperature display status will return and the value from the previous mode will be used.
  5. If the appliance is switched off or the mode is changed, VAC mode will be reset and the number of days entered will be lost.
  6. According to the vacation days entered by the user, heating will begin at 12:00 on the second to last day of the vacation period. The first heating cycle will heat to 65°C to ensure that the water sterilization requirements have been reached. After the heating is completed, the appliance will switch to AUTO mode.

05. Boost function

BOOST mode will take priority over other modes. This mode will run for a single heating cycle, then revert back to the previous mode set. In this mode, the heat pump and back-up electric element operate simultaneously to reduce the heating time.

When operating, the icon will appear. After the set temperature has been reached, the icon will disappear and the appliance will operate in the mode used prior to BOOST function.

06. Lock screen

  1. With the appliance turned on, hold the TIMER and BOOST keys simultaneously for 6 seconds.
  2. The controller will beep twice and the lock screen icon will appear, indicating the screen is locked.
  3. To exit lock screen, hold the TIMER and BOOST keys simultaneously for 6 seconds. The controller will beep 4 times and the lock screen icon will disappear. The controller will now be adjustable.

07. Service mode

Note: Many of the features in service mode are for advanced configurations with connections to off-peak power switching or solar, however there are some settings in here that could be beneficial for adjustments to your system such as water sterilization, heat pump maximum working time, setting the day of the week and temperature differential.

Enter Service Mode:

  1. Enter the Standby Mode by pressing the Key, only the temperature and time will be displayed.
  2. Press and hold the + and SET keys for 6 seconds to enter Service Mode.
  3. "LL" will be displayed. The options are "NO" normally open (default) and "NC" normally closed. This setting is used for off-peak or solar switching signals. Advanced technical use only. Press SET key to enter the next setting.
  4. "LP" will be displayed. The options are for the off-peak logic type used in ECO mode;

"01" Manual timer (user defined time periods of operation)

"02" Off-peak power switching signals (for meters capable of off-peak automatic power switching.)

"O3" Photovoltaic (PV) switching signals (for supplementing with photovoltaic (PV) solar energy.)

Advanced technical use only. Press SET key to enter the next setting.

  1. "LA" will be displayed. The PV function will work in AUTO mode, the options are "ON" or "OFF", Press + or - key to cycle through settings. This will switch PV operation mode on when there is a PV signal in AUTO mode, if using PV, we recommend this setting is "ON." Disregard if no PV in use. Press SET key to enter the next setting.
  2. "Lb" will be displayed. This setting is used to set the heating temperature when connected to PV solar panels.

The adjustable range is between 65-75°C, the default is 65°C. Press + or - key to cycle through settings.

Disregard if no PV in use. Press SET key to enter the next setting.

  1. "LC" will be displayed. This setting is used to determine the heating source when connected to PV solar panels, a signal is active and there is sufficient solar electricity supply. The options are;

"O1" The heat pump and electric element will operate simultaneously. Default.

"02" The heat pump will operate and if set temperature is not reached within the differential setting, the electric element will assist in heating.

"03" Only the electric element will be used for heating.

Disregard if no PV in use. Press + or - key to cycle through settings. Press SET key to enter the next setting.

  1. "AL" will be displayed. Periodic water sterilization by heating can be selected. The options are "ON" to enable this function (default) or "OFF" to disable the function, press + or - key to cycle through settings. Press SET key to enter the next setting.
  2. "Ah" will be displayed. The temperature of water sterilization can be adjusted if the above function is "ON," press + or - key to cycle through settings between 65-75°C. Press SET key to enter the next setting.
  3. "Ad" will be displayed. The frequency of the water sterilization can be adjusted by days between 7–30, the default is 7. Press + or - key to cycle through settings. Press SET key to enter the next setting.
  4. "AA" will be displayed. This is the maximum working time of the heat pump before auxiliary heating activates. The hours can be adjusted between 5-15, the default is 10. Press + or - key to cycle through settings. Press SET key to enter the next setting.
  5. "Ct" will be displayed. This setting is used to set the current day of the week, adjustable from 1-7, with Monday being 1 and Sunday being 7. Press + or - key to cycle through settings. Press SET key to enter the next setting.
  6. "Bt" will be displayed. This is the temperature differential. This setting controls when the heat pump will start operation after the actual temperature drops below the set temperature. The adjustable range is between 5–15°C, the default is 10°C. Press + or - key to cycle through settings. Press SET key to confirm.
  7. You will now return to the standby mode display. Press the 🔒 key to enter operational mode. Your system should begin operating within the next 5 minutes.

08. Fault codes

Enter Fault code query:

  1. Enter the Standby Mode by pressing the ⏻ key, only the temperature and time will be displayed.
  2. Press and hold the + and - keys for 6 seconds to enter Fault codes.
  3. "EO" will be displayed if there is no fault. If there is a fault, it will be displayed in order of the last known fault. Press the - key to scroll back to previous faults until the oldest stored fault EO1 is displayed. The last 10 fault codes are stored in the appliance.
  4. If no keys are pressed for 6 seconds, the appliance will exit this mode. Pressing the key will also exit and return to Standby Mode.
  5. To clear the fault code memory, press and hold the + and - key simultaneously for 6 seconds whilst in the fault code mode.
E0No faults foundE4Ambient temperature sensor fault
F0Communication fault (Wi-Fi)E5Evaporation temperature sensor fault
F2Operating temperature protectionE6Air exhaust temperature sensor fault
F3Air exhaust temperature protectionEDAir intake temperature sensor fault
F5Evaporation high temperature protectionE7Communication fault (display-control panel)
F6Compressor over-current protectionE8Pressure switch protection
E1Electrical leakage alarmE9Ambient temperature protection
E2Over temperature alarm (stored water)EFOff-peak power switching signal fault
E3Inner temperature sensor faultL7Fan fault

ECO Mode Controls

This guide is designed to better explain the controls and operation of the three economy modes currently available to you with your Heat Pump Water Heater.

  1. Manual timer
  2. Off-peak power signal
  3. Photovoltaic (PV) solar power

01. Manual timer operation

Note: This appliance must be connected to a power supply providing electricity 24 hours per day. This mode is designed to manually set the times of operation for either the off-peak time, in preparation for periods of high hot water usage, to take advantage of higher ambient temperatures for maximum gains, or to limit operational noise during certain periods (e.g., night time).

These settings should be available under the appliance's default settings. If the settings are different from default, this guide will also explain how to achieve the desired settings in the first 12 steps.

Enter Service Mode:

  1. Enter Standby Mode by pressing the key; only the temperature and time will be displayed. Note: Skip to step 12 if all settings remain default or the appliance is in its first-time use.
  2. Press and hold the + and SET keys for 5 seconds to enter Service Mode.
  3. "LL" will be displayed. Disregard if using manual timer. Press SET key to enter the next setting.
  4. "LP" will be displayed. For manual timer, press + or - key to cycle through settings until "01" is displayed. Press SET key to enter the next setting.
  5. Press the SET key to cycle through the next three settings, disregarding "LA" "Lb" "LC"
  6. "AL" will be displayed. Periodic water sterilization by heating can be selected. The options are "ON" to enable this function (default) or "OFF" to disable the function, press + or - key to cycle through settings. Press SET key to enter the next setting.
  7. "Ah" will be displayed. The temperature of water sterilization can be adjusted if the above function is "ON," press + or - key to cycle through settings between 65–75°C. Press SET key to enter the next setting.
  8. "Ad" will be displayed. The frequency of the water sterilization can be adjusted by days between 7–30, the default is 7. Press + or - key to cycle through settings. Press SET key to enter the next setting.
  9. "AA" will be displayed. This is the maximum working time of the heat pump before auxiliary heating activates. The hours can be adjusted between 5–15, the default is 10. Press + or - key to cycle through settings. Press SET key to enter the next setting.
  10. "Ct" will be displayed. This setting is used to set the current day of the week, adjustable from 1–7, with Monday being 1 and Sunday being 7. Press + or - key to cycle through settings. Press SET key to enter the next setting.
  11. "Bt" will be displayed. This is the temperature differential. This setting controls when the heat pump will start operation after the actual temperature drops below the set temperature. The adjustable range is between 5–15°C, the default is 10°C. Press + or - key to cycle through settings. Press SET key to confirm.
  12. You will now return to the Standby Mode display. Press the ⏻ key to enter operational mode.

HAIER HP200M1-U1 - Enter Service Mode: - 1

  1. Press the MODE key until you are in ECO mode, the ECO icon will be displayed.
  2. Press the SET key to begin entering times of operation.
  3. "L1" will be displayed. This is the first time period during the week (Monday–Friday.) "START" will be displayed indicating the start time of the heating cycle, and the hours will begin flashing 00:00. Press + or - key to adjust the start hour of the first timer.

Press the SET key to move on to adjusting start minutes, the minutes will begin flashing 00:00. Press + or - key to adjust the start minutes of the first timer.

  1. Press the SET key to confirm and move on to "L1 STOP." The hours will begin flashing 00:00. Press + or - key to adjust the stop hour of the first timer.

Press the SET key to move on to adjusting start minutes, the minutes will begin flashing 00:00. Press + or - key to adjust the stop minutes of the first timer.

  1. Press the SET key to confirm the first timer and move on to "L2 START." A second timer can be added during the week (Monday–Friday) using the same method described above. If no additional timer is required, this setting can remain as 00:00.
  2. Press the SET key to confirm the first timer and move on to "L3 START." A timer can be added during the weekend (Saturday–Sunday) using the same methods described above.
  3. Press the SET key to confirm the first timer and move on to "L4 START." A second timer can be added during the weekend (Saturday–Sunday) using the same methods described above. If no additional timer is required, this setting can remain as 00:00.

Note: This is user preference and settings may need adjustment over time depending on needs.

Considerations:

a) Does your power supplier provide an off-peak period of time that you can take advantage of? b) At certain times of the day hot water usage will be higher, such as showering. The timer can be set to ensure a sufficient supply of hot water is available for these periods. c) Do you want to take advantage of the peak ambient temperatures of midday-on, to assist the Heat Pump for maximum efficiency? d) Do you want to limit the Heat Pumps operation during the night to keep noise levels to a minimum?

02. Off-peak power signal

Note: This appliance must be connected to a power supply providing electricity 24 hours per day. This mode is designed for situations where a meter (eg; smart meter) is constantly supplying electricity but automatically switches depending on peak hours.

This is not suitable for situations and meters where tariff or ripple control turns off electricity supply for a period of time (peak.)

Please engage your electrician or power provider for further information on the suitability of your electrical devices.

2.1 Off-peak power signal operation

  1. Enter the Standby Mode by pressing the 🔊 key, only the temperature and time will be displayed.
  2. Press and hold the + and SET keys for 5 seconds to enter Service Mode.
  3. "LL" will be displayed. The options are "NO" normally open (default) and "NC" normally closed. You must know if the signal from the switching device or meter are Normally Open or Normally Closed to meet this setting. Press SET key to enter the next setting.
  4. "LP" will be displayed. For Off-peak power signal, press + or - key to cycle through settings until "02" is displayed. Press SET key to enter the next setting.
  5. "LA" will be displayed. This setting is only used when connected to PV solar panels. Press SET key to enter the next setting.
  6. "Lb" will be displayed. This setting is only used when connected to PV solar panels. Press SET key to enter the next setting.
  7. "LC" will be displayed. This setting is only used when connected to PV solar panels. Press SET key to enter the next setting.
  8. "AL" will be displayed. Periodic water sterilization by heating can be selected. The options are "ON" to enable this function (default) or "OFF" to disable the function, press + or - key to cycle through settings. Press SET key to enter the next setting.
  9. "Ah" will be displayed. The temperature of water sterilization can be adjusted if the above function is "ON," press + or - key to cycle through settings between 65–75°C. Press SET key to enter the next setting.
  10. "Ad" will be displayed. The frequency of the water sterilization can be adjusted by days between 7–30, the default is 7. Press + or - key to cycle through settings. Press SET key to enter the next setting.
  11. "AA" will be displayed. This is the maximum working time of the heat pump before auxiliary heating activates. The hours can be adjusted between 5-15, the default is 10. Press + or - key to cycle through settings. Press SET key to enter the next setting.
  12. "Ct" will be displayed. This setting is used to set the current day of the week, adjustable from 1–7, with Monday being 1 and Sunday being 7. Press + or - key to cycle through settings. Press SET key to enter the next setting.
  13. "Bt" will be displayed. This is the temperature differential. This setting controls when the heat pump will start operation after the actual temperature drops below the set temperature. The adjustable range is between 5–15°C, the default is 10°C. Press + or - key to cycle through settings. Press SET key to confirm.
  14. You will now return to the Standby Mode display. Press the ⏻ key to enter operational mode.
  15. Press the MODE key until you are in ECO mode, the ECO icon will be displayed. Validation of operation will be confirmed by the HC icon being illuminated, confirming a signal between the appliance and off-peak metering.

Note: This mode operates the heat pump only when an off-peak connected signal is detected!

Confirm with your power provider the time and duration of this service to ensure suitability for ample heating time and household periods of high hot water usage are sufficient.

For example: If the power company provides off-peak metering between 0000-0500, the water heater will operate only during these hours until the set temperature is reached. If the main period of hot water usage is late evening or night time and hot water has been drawn off throughout the day without re-heating due to peak time, there may not be sufficient hot water for high demand fixtures such as showers or baths.

OFF-PEAK POWER SIGNAL WIRE (2*0.75mm² black wire) POWER CABLE (3*1.5mm²) SMART METER 0123.0 kWh 1 AUTO 0 1 16A

03. Photovoltaic (PV) solar power signal operation

  1. Enter the Standby Mode by pressing the ⏻ key, only the temperature and time will be displayed.
  2. Press and hold the + and SET keys for 5 seconds to enter Service Mode.
  3. "LL" will be displayed. The options are "NO" normally open (default) and "NC" normally closed. You must know if the signal from the switching device or solar controller are Normally Open or Normally Closed to meet this setting. Press SET key to enter the next setting.
  4. "LP" will be displayed. For PV power signal, press + or - key to cycle through settings until "O3" is displayed. Press SET key to enter the next setting.
  5. "LA" will be displayed. The PV function will work in AUTO mode, the options are "ON" or "OFF", Press + or - key to cycle through settings. This will switch PV operation mode on when there is a PV signal in AUTO mode, if using PV, we recommend this setting is "ON." Press SET key to enter the next setting.
  6. "Lb" will be displayed. This setting is used to set the heating temperature when connected to PV solar panels. The adjustable range is between 65-75°C, the default is 65°C. Press + or - key to cycle through settings. Press SET key to enter the next setting.
  7. "LC" will be displayed. This setting is used to determine the heating source when connected to PV solar panels, a signal is active and there is sufficient solar electricity supply. The options are:

"O1" The heat pump and electric element will operate simultaneously. Default.

"02" The heat pump will operate and if set temperature is not reached within the differential setting, the electric element will assist in heating.

"03" Only the electric element will be used for heating.

Press + or - key to cycle through settings. Press SET key to enter the next setting.

  1. "AL" will be displayed. Periodic water sterilization by heating can be selected. The options are "ON" to enable this function (default) or "OFF" to disable the function. Press + or - key to cycle through settings. Press SET key to enter the next setting.
  2. "Ah" will be displayed. The temperature of water sterilization can be adjusted if the above function is "ON." Press + or - key to cycle through settings between 65–75°C. Press SET key to enter the next setting.
  3. "Ad" will be displayed. The frequency of the water sterilization can be adjusted by days between 7–30, the default is 7. Press + or - key to cycle through settings. Press SET key to enter the next setting.
  4. "AA" will be displayed. This is the maximum working time of the heat pump before auxiliary heating activates. The hours can be adjusted between 5-15, the default is 10. Press + or - key to cycle through settings. Press SET key to enter the next setting.
  5. "Ct" will be displayed. This setting is used to set the current day of the week, adjustable from 1-7, with Monday being 1 and Sunday being 7. Press + or - key to cycle through settings. Press SET key to enter the next setting.
  6. "Bt" will be displayed. This is the temperature differential. This setting controls when the heat pump will start operation after the actual temperature drops below the set temperature. The adjustable range is between 5–15°C, the default is 10°C. Press + or - key to cycle through settings. Press SET key to confirm.
  7. You will now return to the standby mode display. Press the Key to enter operational mode. You can now choose between ECO mode, or AUTO mode if selected "ON" in step 5 "LA."

HAIER HP200M1-U1 - Photovoltaic (PV) solar power signal operation - 1

  1. For AUTO mode: Press the MODE key until you are in AUTO mode, the AUTO icon will be displayed. Validation of operation will be confirmed by the PV icon being illuminated, confirming a signal between the appliance and PV solar.

Note: AUTO mode will operate via power company electrical supply if no PV signal is detected!

HAIER HP200M1-U1 - Photovoltaic (PV) solar power signal operation - 2

  1. For ECO mode: Press the MODE key until you are in ECO mode, the ECO icon will be displayed. Validation of operation will be confirmed by the PV icon being illuminated, confirming a signal between the appliance and PV solar.

Note: ECO mode operates the heat pump only when sufficient PV solar electricity supply is available!

PHOTOVOLTAIC SOLAR PANELS (PV) INVERTER DC / AC GRID SUPPLY SIGNAL WIRE (2*0.75mm² black wire) 2A METER Q1 23.0 kWh 1 0 16A POWER CABLE (3*1.5mm²)

Additional functions

This guide is designed to better explain the controls and operation of additional functions and controls available with your Heat Pump Water Heater.

  1. Real-time parameter query
  2. Sterilization (Anti-legionella)
  3. Stored hot water display
  4. Demo (display) mode
  5. Parameter query

Enter parameter query:

  1. Enter the Parameter Query Mode with the appliance powered on ⏻. The operational working mode will be displayed.
  2. Press and hold the MODE and SET keys for 6 seconds to enter Parameter Query.
  3. The controller will beep 8 times indicating you have entered the real-time parameter query mode. Press and hold the + and - keys to scroll through parameters.
  4. If no keys are pressed for 6 seconds, the appliance will exit this mode.
SensorCodeDefinition
Ambient temperaturen15Real-time ambient temperature reading
Exhaust temperaturen6Real-time exhaust temperature reading
Suction temperaturen18Real-time suction temperature reading
Evaporator temperaturen4Real-time evaporator temperature reading
Storage tank water temperaturen122Real-time water storage tank reading
Opening of electronic expansion valven123Flashing represents 360 steps
Fan speedn124Blinking represents 580 revolutions

02. Sterilization (Anti-legionella)

The sterilization function can be adjusted in the Service Mode. The settings below are relevant for this function:

  1. "AL" will be displayed. Periodic water sterilization by heating can be selected. The options are "ON" to enable this function (default) or "OFF" to disable the function, press + or - key to cycle through settings. Press SET key to enter the next setting.
  2. "Ah" will be displayed. The temperature of water sterilization can be adjusted if the above function is "ON," press + or - key to cycle through settings between 65–75°C. Press SET key to enter the next setting.
  3. "Ad" will be displayed. The frequency of the water sterilization can be adjusted by days between 7–30, the default is 7. Press + or - key to cycle through settings. Press SET key to enter the next setting.

Note: If sterilization function is set "OFF," it is recommended that the set temperature be a minimum of 60°C.

03. Stored hot water display

This display indicates the temperature of water in the storage tank, not total volume. The hot water service is a pressurised system and should remain full of stored water.

< 35°C35-40°C41-45°C46-50°C51-55°C56-75°C
HAIER HP200M1-U1 - Stored hot water display - 1HAIER HP200M1-U1 - Stored hot water display - 2HAIER HP200M1-U1 - Stored hot water display - 3HAIER HP200M1-U1 - Stored hot water display - 4[5K5O][88BY]

04. Demo (Display) mode

This display mode allows for certain display functions to be operational, whilst the appliance itself is not operating. This setting should only be used for display purposes e.g., retailers, wholesalers.

  1. Enter the Standby Mode by pressing the ⚙ key; only the temperature and time will be displayed.
  2. Press and hold the MODE key for 6 seconds to enter Service Mode.
  3. "A1" represents Operational Mode. "A2" represents display (demo) mode.
  4. Press the + or - key to cycle through Operational or Demo modes.
  5. Press the ⏻ key to confirm and exit selection.
  6. The default is "A1" Operational Mode.