Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Security System
Brand Gewiss
Model GW12682
Dimensions (L x H x D) 120 x 80 x 30 mm
Weight 200 g
Power Supply 12 V DC via mains adapter
Power Consumption 5 W max
Main Functions Motion detection, audible alarm, phone notification, remote control
Integrated Sensors Passive infrared (PIR) detector
Detection Range 10 m, 90° angle
Alarm Sound Level 105 dB
Connectivity GSM (SIM card) and Wi-Fi
Operating Temperature -10°C to 50°C
Maintenance and Cleaning Clean with a soft dry cloth; avoid solvents
Safety Surge protection, tamper alarm
Spare Parts and Repairability Sensors and backup battery replaceable by a professional
General Information Suitable for indoor use; CE certification

Frequently Asked Questions - GW12682 Gewiss

How to install the Gewiss GW12682 security system?
Place the device in a strategic location (recommended height 2 meters), plug in the mains adapter, insert a SIM card (if GSM) and follow the instructions in the Gewiss Home app.
How to reset the GW12682 to factory settings?
Hold the Reset button on the back of the device for 10 seconds until the LED flashes rapidly.
What to do if the alarm does not trigger?
Check that the device is powered on, the sensors are not obstructed, and the sensitivity is set correctly in the settings.
How to configure emergency numbers?
In the app, go to Settings > Emergency Contacts and add up to 5 numbers. Confirm with the PIN code.
Can I use the GW12682 without a subscription?
Yes, the basic functions (local alarm) are free. Phone notifications require a SIM card with an SMS/minutes plan.
How to change the alarm PIN code?
On the keypad (if provided) or in the app, select Change code, enter the old code, then the new one (4 to 6 digits).
What does the flashing red LED mean?
A flashing red LED indicates that the alarm has been triggered or a mains failure is detected. Refer to the error code section in the manual.
Is the GW12682 compatible with voice assistants?
No, this model does not support Alexa or Google Home. It uses its own Gewiss Home app.
How to test the motion detector?
Activate Test mode in the app. Walk in front of the sensor: a notification should appear on your phone.
Where to download the complete manual for the GW12682?
Go to notice-facile.com and search for 'Gewiss GW12682' to download the official PDF in French.

User questions about GW12682 Gewiss

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Security System in PDF format for free! Find your manual GW12682 - Gewiss and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. GW12682 by Gewiss.

USER MANUAL GW12682 Gewiss

Morsetti Bus KNX / EIB:

Attention - Important

Warning! The safety of this appliance is only guaranteed if all the instructions given here are followed scrupulously. These should be read thoroughly and kept in a safe place.

All Chorus products must be installed in compliance to CEI 64-8 Standards for household appliances and similar items, in dust-free environments where no special protection is required to prevent penetration of water.

The GEWISS sales organisation is at your disposal for clarifications and technical information.

Gewiss SpA reserves the right to make changes to the product described in this manual at any time and without giving any notice.

CONTENTS

OPERATING INSTRUCTIONS page

- Description of the product and how it works ....16

- Front view ....17

INSTALLATION

- Connections ....18

- Indicators and control elements positions....19

- Warnings for installation phase....20

- Assembly and connections ....20

- General description ......21

- Connection of the bus cable to the KNX/EIB terminal....21

- Connection of the transponder reader to the bus line ....21

- Electrical safety....21

- Conditions of use....22

- Homologation ....22

- EC Marking....22

TECHNICAL SPECIFICATIONS ......23

OPERATING INSTRUCTIONS

Description of the product and how it works

The transponder slot reader GW1X 682 is a KNX / EIB device which allows the transponder to recognise the badges and notify the presence of supervision (e.g. reception);

The device is fitted with three physical ON/OFF inputs to control the door open/closed switch or other signals (window contact, bathroom alarm etc).

The device has two 24Vac relays which are used, for instance, to control the lock on doors, to control "courtesy lights" to enable electrical loads present in the environment or other.

The transponder reading is performed by inserting the badge into the front slot reader.

The configuration of the device, the physical address, parameters and communication objects are all performed using the ETS software (Eib Tool Software). The product database can be downloaded from our website at www.gewiss.com, (product area - Domotics)

The transponder slot reader is placed inside a standard flush-mounted box, and mounted on Chorus supports in the space of three modules.

OPERATING INSTRUCTIONS

Front view

Backlit slot reader to insert the transponder badges

Technical line drawing of a device casing with a card symbol and 'KNX E13' label (no readable text or symbols beyond branding)

If there is no badge, the ON / OFF backlight setting on the badge slot reader can be configured using the ETS software;

when a badge is inserted the backlight is always OFF.

Connections

Bus Line: KNX / EIB terminal, conductor ∅ 0.6-0.8 mm.

12/24V ac/dc power supply: Screw terminals, max cable section 1.5 mm 2

ON/OFF outputs: Screw terminals, max cable section 1.5 mm

ON/OFF inputs without potential: Screw terminals, max cable section 1.5 mm 2

BUS / KNX Power supply 12/24V ac/dc Interface KNX / EIB IN3 IN2 IN1 CI I3 I2 I1 L2 L1 OUT 2 OUT 1 I ON / OFF inputs to the KNX / EIB commands Max 24V ac/dc 2A Max 24V ac/dc 2A

Traditional ON / OFF inputs to manage the KNX / EIB commands

INSTALLATION

Indicators and control element positions
12/24V GWXXXXX KNX/EIB LED KNX / EIB CI I3I2I1 NO2L2 NO1 L1 IN OUT2OUT1 Button KNX / EIB

Screw terminals:

1 power supply 12/24 V ac/dc
2 power supply 12/24 V ac/dc

CI KNX/EIB common inputs

I1 input 1 without potential
I2 input 2 without potential
I3 input 3 without potential

L1 common relay 1

NO1 relay 1 NO contact

L2 common relay 2

NO2 relay 2 NO contact

KNX / EIB Bus terminals:

  • negative pole
  • positive pole

KNX/ EIB Button

Button to switch between normal mode or programming mode or to identify the physical address

KNX / EIB Led

LED which signals normal mode (led off) or addressing mode (led on).

It switches off automatically after the detection/programming of the physical address

INSTALLATION

Warnings for installation phase

The device must be used for fixed installations in closed environments, dry areas, in wall or flush-mounted boxes.

  • The device cannot be installed inside the same box together with 230 V devices.
  • Only qualified personnel are permitted to install and start up the device.
  • Always comply with the safety and accident prevention standards and regulations in force.
  • The device must not be opened. Any faulty devices must be returned to the relative service center.

Assembly and connections

Only mount the reader in a horizontal position.

Exploded view diagram of an electronic device showing internal components and casing (no text or labels)

General description

To start up the device you must access the "KNX / EIB Button" to switch from normal mode to programming mode; the button is on the back of the casing.

When installing the device, make sure that the connection cables are long enough to extract the device / support frame from the flush-mounted box together.

Connection of the bus cable to the KNX / EIB clamp

The Bus KNX / EIB clamp (supplied with the device) is suitable for a single wire conductor with a 0.6-0.8 mm.

Connection of the transponder reader to the bus line

Insert the KNX / EIB Bus clamp, previously connected to the bus cable, into the integrated bus coupling slot which is on the back of the device.

Slide the bus clamp as far as possible.

Configuration

The transponder reader must be configured using one of the access management softwares - "GWHotel" or "GWAccess" used to configure the transponder badges and the assigning of access rights

INSTALLATION

Electrical safety

Pollution level (according to IEC 60664-1 Standard): 2.

Protection rating (according to EN 60529 Standard): IP 20.

Protection class (according to IEC 61140): III.

Overload rating (according to IEC 664-1): III.

Bus: safety voltage SELV DC 24V.

Complies with EN 50090 and IEC 664-1 Standards.

EMC requirements

Complies with EN 61000-6-3, EN 61000-6-1 and EN 50090-2-2 Standards.

Conditions of use

According to EN 50090-2-2 Standards.

Ambient temperature while working: 0°C +45°C.

Storage temperature: - 20 + 55°C.

Relative humidity: max. 90%.

Homologation

KNX/EIB homologated.

EC Marking

Complies to the low voltage EC Directive (civil and industrial building).

TECHNICAL SPECIFICATIONS

Power supply

BUS voltage KNX/EIB: 29V dc SELV

BUS absorption: 5mA

External auxiliary voltage: 12/24V ac/dc +/- 10%

Max. auxiliary power absorption: 150mA

KNX/EIB Inputs

3 contacts without potential

the power is supplied internally at 24V 1mA

Relay outputs

2 NO contacts 2A cosφ0,6, 24V ac

Channel 1: general use or electrical lock command

Channel 2: courtesy lights or general use

Transponder reader

Chip reader/writer transponder Atmel/Temic

Power supplied internally at 5V dc

Working power frequency: 125KHz

Control elements

Button to switch between normal mode / programming mode

Indicators

Backlit badge slot reader

FRANÇAIS

Porte-Transponder

Attention - Important

Bornes Bus KNX / EIB:

Tension BUS KNX / EIB: 29V cc SELV

Descripción general

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Gewiss

Model : GW12682

Category : Security System