INVENTUM BC20 - Sphygmomanometer

BC20 - Sphygmomanometer INVENTUM - Free user manual and instructions

Find the device manual for free BC20 INVENTUM in PDF.

📄 40 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice INVENTUM BC20 - page 31
View the manual : Français FR Deutsch DE English EN Nederlands NL
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Electronic wrist blood pressure monitor
Brand Inventum
Model BC20
Measurement method Non-invasive oscillometric
Compatible wrist circumference 12.5 - 20.5 cm
Systolic measurement range 50 - 250 mmHg
Diastolic measurement range 40 - 180 mmHg
Pulse measurement range 40 - 160 beats/min
Blood pressure accuracy ±3 mmHg
Pulse accuracy ±5% of displayed value
Display LCD
Memory 60 measurements with date and time
Power supply 2 x 1.5 V micro batteries (LR03)
Safety classification Type BF
Operating conditions +10°C to +40°C, max humidity 85%
Storage conditions -5°C to +50°C, max humidity 85%
Cleaning Slightly damp cloth, no detergent
Warranty 24 months

Frequently Asked Questions - BC20 INVENTUM

How to set the date and time on the BC20 blood pressure monitor?
After inserting the batteries, press and hold the On/Off button for 5 seconds until '0' is displayed. Then press the M button for 2 seconds until '01' blinks. Use the On/Off button to adjust the year and confirm with M. Repeat for month, day, hour and minutes.
How to take a correct blood pressure measurement?
Place the monitor on the bare left wrist, about 1 cm from the thenar and hypothenar eminences. Sit down, place your arm on a table with the device at heart level. Rest for 3 to 5 minutes before measurement. Press On/Off.
What to do if the low battery symbol appears?
Replace the batteries with two new 1.5 V micro batteries (LR03), observing polarity. Do not dispose of used batteries in household waste; deposit them at an appropriate collection point.
How to view stored measurements?
With the device off, press the M button to display the last measurement. Press M again to scroll through the 60 measurements. After the last one, the average is displayed. The date and time of each measurement are visible.
What do the error messages mean?
Errors occur if: inflation >25s, movement during measurement, insufficient pressure, extreme values, or low batteries. Wait a few minutes and take another measurement. If 'ERR 330' is displayed, the pressure exceeded 330 mmHg.
How to clean the BC20 blood pressure monitor?
Use a slightly damp cloth without detergent or abrasive. Never run the device under running water to avoid damaging electronic components.
What is the WHO classification of blood pressure values?
Hypotension: systolic <105 or diastolic <60. Normal: 105-120/60-80. Prehypertension: 120-140/80-90. Hypertension stage I: 140-160/90-100. Hypertension stage II: >160/>100. Consult a doctor if necessary.
Can the monitor be used by several people?
Yes, each user can take their measurements. The memory stores the last 60 measurements without user distinction. It is advisable to note the measurements and share them with your doctor.
What to do if the warranty has expired?
If the 24-month warranty has expired, you can send the device to Inventum Holland BV or new E.T.P. bvba. A quote will be provided before repair if you request it, otherwise the repair will be charged.
Is the device suitable in case of cardiac arrhythmia?
In case of cardiac arrhythmias, the accuracy of wrist measurement may be reduced. It is recommended to use an arm blood pressure monitor. Consult your doctor for personalized advice.

User questions about BC20 INVENTUM

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Sphygmomanometer in PDF format for free! Find your manual BC20 - INVENTUM and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. BC20 by INVENTUM.

USER MANUAL BC20 INVENTUM

POLSBLOEDDRUKMETER HANDGELENK-BLUTDRUCKMESSGERÄT TENSIOMÈTRE DE POIGNET ÉLECTRONIQUE WRIST BLOOD PRESSURE MONITOR

INVENTUM BC20 - 1

0344

Name/function of the parts

  1. LCD-display
  2. Battery compartment cover
  3. Memory button M
  4. Start/ Stop button
  5. Cuff

NEDERLANDS

natural_image Silhouette of a person with heart symbols on their arm and wrist, no text or symbols present
natural_image Silhouette of a person with heart symbols on their chest, holding an object (no text or symbols present)
natural_image Silhouette of a person with heart symbols on their chest, holding an object (no text or symbols present)

Instruction manual Inventum blood pressure monitor, BC20.

Read the instruction manual carefully before use and keep the instructions in a safe place for future reference.

EXPLANATION SYMBOLS

INVENTUM BC20 - EXPLANATION SYMBOLS - 1

Legislation requires that all electrical and electronic equipment must be collected for reuse and recycling. Electrical and electronic equipment marked with the symbol indicating separate collection of such equipment must be returned to a municipal waste collection point.

Device classification type BF

Please read the instructions for use!

INTRODUCTION

You can measure your blood pressure quickly and easily with the blood pressure wrist computer, save the readings and display the progress and average of the readings. The computer is used for non-invasive measurement and monitoring of your arterial blood pressure levels.

This blood pressure measuring device meets the high standards of the German High Blood Pressure League and carries the seal of the German High Blood Pressure League. Further information at www.paritaet.org/hochdruckliga

The computer complies with the requirements of the European Directive for Medical Products, the German Medical Product Act as well as the European standards EN1060-1 (Non-invasive blood pressure measuring devices Part 1: General requirements), EN1060-3 (Non-invasive blood pressure measuring devices Part 3: supplementary requirements for electromechanical blood pressure measuring systems).

SAFETY INSTRUCTIONS

  • Read the instruction manual carefully and completely before using the appliance and keep them for later use.
    • Always measure your blood pressure at the same time of day in order to ensure comparability of the readings.
  • Relax for about 3 - 5 minutes before every measurement!
  • Wait 5 minutes between successive measurements!
  • The measurements you make yourself are only for your information – they are no substitute for a medical examination! Discuss your readings with your doctor and on no account make your own medical decisions (e.g. drugs and their dosages)!
  • The wrist measurement will be less accurate if an arm suffers from restricted blood circulation resulting from chronic or acute vascular diseases (including vasoconstrictions). In this case, use a sphygmomanometer for measurements on the upper arm.
  • Measuring errors can occur in diseases of the cardiovascular system, as well as with very low blood pressure, irregular blood circulation and arrhythmia and also in the case of other symptoms. The blood pressure computer consists of precision-made electronic components. The measuring accuracy and life of the computer depend on the care with which it is treated:

  • Protect the computer from shocks and be careful not to drop it,

  • protect it against moisture, dirt, wide fluctuations in temperature and the direct rays of the sun,
  • do not use it in areas where there are strong electromagnetic fields, i.e. keep it away from transmitters and mobile phones.
  • Do not press buttons without the cuff fitted.
  • Use the computer only on persons for whose wrist size the computer is intended.
  • If the computer is not used for a lengthy period of time, it is advisable to remove the batteries.
  • Keep the batteries out of reach of children. Batteries do not belong in domestic waste.
  • Dispose of batteries at the appropriate collection points.
  • Do not open the computer. Failure to comply invalidates the warranty. You must not adjust or repair the computer yourself or its correct function will no longer be guaranteed.
  • This device is intended for wrist blood-pressure/pulse measurement on adult human beings.
  • This instrument is not intended for commercial or clinical use.

  • Never immerse the blood pressure monitor in water or any other liquid.

  • If you have further questions about using our devices, please contact your dealer.

INSTRUCTIONS FOR USE

Inserting/ changing batteries

  • Remove the battery compartment cover.
  • Insert the two batteries into the battery compartment ensuring correct polarity.
  • Use exclusively brand-name batteries of the type: 2x1.5 V Micro (Alkaline Type LR 03).
  • Then close the battery compartment by fitting the cover and clicking it in position.

When the batteries are almost exhausted, an empty battery symbol ☐ appears at bottom left in the display and the batteries must then be exchanged. They are considered to be toxic waste and, as such, should be disposed of in special containers, toxic waste collection points or brought to electrical goods dealers. You are legally obliged to dispose of the batteries.

Note: Batteries containing pollutant substances are marked as follows: Pb-= Battery contains lead, Cd = Battery contains cadmium, Hg = Battery contains mercury.

Setting date/time

The date/time setting is necessary, so that you can save your readings correctly with the date and time and call them up again later.

  • After inserting the batteries, press the Start/Stop button for 5 seconds and wait until a "0" appears for the systole and diastole.
  • Then press the save button for 2 seconds until the year "01" flashes at the lower right in the display.
  • Set the year with the Start/Stop button and confirm it with memory button "M".
    • The months, days, hours and minutes displays flash in turn.
  • They must be set with the Start/Stop button and and confirmed with the memory button "M".
    • After it has been set, the time will be shown continuously in the display.

Applying the blood pressure monitor

  • Apply the blood pressure computer to the inside of the left wrist.
  • Ensure that the wrist is unclothed.
  • Close the cuff with the velcro fastener, so that the top margin of the computer is about 10 mm below the ball of the thumb (see illustration).
  • The cuff must be placed tightly around the wrist but must not constrict.

1 cm

Measuring blood pressure

  • Sit in a relaxed position.
  • Ensure that your arm is supported and bend it so that it is at the level of your heart (see illustration).
  • Before measurement allow an adequate relaxation time of 3 - 5 minutes.
  • Now press the Start/Stop button to start the measurement.
    • The cuff will now inflate automatically to 180 mmHg.
  • When the 180 mmHg pressure is reached, the pressure is automatically released from the cuff and a beating heart appears in the display.
  • If the preset pressure of 180 mmHg is inadequate during inflation, the device automatically pumps up to a higher pressure.
  • Your blood pressure readings and pulse rate will then appear in the display.
  • To switch off and release the pressure, press the Start/Stop button again.
  • If you forget to switch off the computer, it will switch off automatically after 3 minutes.

INVENTUM BC20 - Measuring blood pressure - 1

natural_image Silhouette of a person with heart symbols on their arm and hands, no text or symbols present

Display of the readings saved

The computer automatically saves the blood pressure readings of the last 60 measurements. When the 60 memory locations are exceeded, the current oldest value is deleted. You can display the memory as follows:

  • Press the memory-button "M" with the computer switched off. The last reading measured appears.
  • You can call up all individual readings saved by pressing the memory button "M" repeatedly.

  • The memory location number is shown in the display at bottom right. the date and time of the individual measurement are shown in the top part of the display.

  • The last result obtained is stored in the first memory location. As soon as a new result is obtained, this appears in the first memory location and the older result moves down to the next location.
  • After the last memory location occupied, the computer shows the average of all readings saved on pressing the memory button "M" again.
  • To switch off, press the Start/Stop button again.
  • If you forgot to switch off the computer, it will switch off automatically after 3 minutes.

Troubleshooting

Error messages appear in the display if:

  • cuff inflation takes longer than 25 seconds,
  • you move during the measurement instead of relaxing quietly,
    • insufficient pressure is reached despite extra inflation,
  • the blood pressure readings are extremely high or low,
  • the inflation pressure is higher than 330 mmHg (error message ERR 330),
  • the batteries are almost exhausted, the batteries must then be exchanged.

In the event of error messages, wait for a short time and measure again.

About Blood Pressure

The World Health Organization (WHO) and National High Blood Pressure Education Program Coordinating Committee have developed a blood pressure standard, according to which areas of low- and high-risk blood pressure are identified. This standard, however, is a general guideline as individual's blood pressure varies among different people and different age groups...etc.

It is important that you consult with your physician regularly. Your physician will tell you your normal blood pressure range as well as the point at which you will be considered at risk.

Table for classification of blood pressure values (unit of measurement mmHg) for adults:

Range Systolic Diastolic Action
Hypotonia (degraded blood pressure)lower than 105 lowerthan 60 Check with doctor
Normal range between 105and 120between 60 and 80Self check
Pre-hypertensive blood pressure range(*)between 120 and 140between 80 and 90Check with doctor
High blood pressure - degree Ibetween 140 and 160between 90 and 100Consult your doctor
High blood pressure - degree IIhigher than 160 higherthan 100 Consult your doctor

* Blood pressure range that might transfer to high blood pressure. Adapted from JNC 2003

CARE & CLEANING

  • Clean your blood pressure computer carefully only with a slightly moistened cloth.
  • Do not use detergents or solvents.
  • On no account must you immerse the computer in water, otherwise liquid can enter it and cause damage.
    • Always store the blood pressure monitor in the storagecase.

Technical data

Type: BC20

Measuring method: non-invasive, oscillometric blood pressure measurement at the wrist, for wrist circumferences

of 12,5 - 20,5 cm

Display range: 0 - 300 mmHg

Measuring range: systolic: 50 - 250 mmHg / diastolic: 40 - 180 mmHg / pulse: 40 - 160/min

Accuracy of the pressure reading: systolic ± 3 mmHg / diastolic: ± 3 mmHg / pulse: ± 5% of the displayed value

Measuring uncertainty: (max. permissible standard deviation according to clinical testing):

systolic: 8 mmHg / diastolic: 8 mmHg

Power supply: 2 x 1,5 V Micro (Alkaline type LR 03)

Classification Application part type BF

Ambient conditions: +10 °C – +40 °C max. 85% atmospheric humidity

Storage/transport: -5^-+50^ max. 85% atmospheric humidity

Key to symbols: Application part type BF

Important! Read the operating instructions

INVENTUM BC20 - Technical data - 1

INVENTUM BC20 - Technical data - 2

GUARANTEE & SERVICE

  • This product is guaranteed for a period of 2 years from the date of purchase against mechanical and electrical defect.
  • Guarantee can only be given if proof of purchase (e.g. till receipt) can be shown. Therefore keep it in a safe place. The guarantee period starts at date of purchase.
    • Guarantee is not valid in case of:

  • normal wear;

  • damage through misuse use or when the instructions were not followed correctly;
  • lack of maintenance;
  • not following the operation- and safety instructions;

- incompetent montage or repairs made by yourself or others;

- using accessories and spare parts which are not suitable for the appliance; for assessment by our technical department.

• The guarantee is not valid for:

- batteries; for assessment by our technical department.

Return the appliance, including proof of purchase and description of the complaint, stamped to:

Inventum Holland BV

Generatorstraat 17

3903 LH VEENENDAAL

The Netherlands

or to:

new E.T.P. bvba

Passtraat 121

9100 Sint Niklaas

BELGIUM

  • Pack it carefully (preferably in the original carton). Ensure unit is clean.
  • Enclose your name and address and quote model number BC20 on all correspondence.

When the guarantee is no longer valid or when the period of guarantee has passed, we will charge any costs that flow out of an assessment and/or repairing.

On request we will supply a statement before repairing. Without requesting a statement, we assume that you, by sending the appliance, automatically order to repair the appliance.

A guarantee period of two months is valid for repairs done by our technical department and the used spare parts, counting from the repairdate. When a malfunction occurs within this period which directly flows out of the repairs and the used spare parts, the consumer has the right of repairs without any costs.

We reserve the right to change this product, packaging and documentation without notice.

Inventum Holland BV