PG-R02 - Heating Infiniton - Free user manual and instructions
Find the device manual for free PG-R02 Infiniton in PDF.
User questions about PG-R02 Infiniton
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Heating in PDF format for free! Find your manual PG-R02 - Infiniton and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. PG-R02 by Infiniton.
USER MANUAL PG-R02 Infiniton
natural_image
Line drawing of a portable outdoor heating lamp with vertical support structure (no text or symbols)Keep the instructions for future reference
natural_image
Simple line drawing of a lamp inside a transparent cube (no text or symbols)text_image
Post bracket Bolt StandPASO 2
text_image
Post Bolt NutPASO 3
text_image
Tank housingPASO 4
text_image
STEP 7 Regulator Gas tanktext_image
QR code image containing encoded data, no visible human-readable textnatural_image
Line drawing of a portable outdoor heating unit with vertical column and circular vent (no text or symbols)Keep the instructions for future reference
- Shut off gas to the appliance.
- Extinguish any open flame.
- f odor continues, immediately call your gas supplier or your fire Department.
FOR YOUR SAFETY
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
- An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance.
WARNING
1) For use outdoors or in amply ventilated areas.
2) An amply ventilated area must have a minimum of 25 % of the surface area open.
3) The surface area is the sum of the walls surface.

natural_image
Simple line drawing of a lamp inside a transparent cube (no text or symbols)WARNING: Improper installation, adjustment, alteration, service or maintenance Can cause injury or property damage. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.
warning
Read the instructions before installation and use.
-This appliance must be installed and the gas cylinder stored in accordance with the regulations in force;
-Do not obstruct the ventilation holes of the cylinder housing;
-Do not move the appliance when in operation;
-Shut off the valve at the gas cylinder or the regulator before moving the appliance;
-The tubing or the flexible hose must be changed within the prescribed intervals;
-Use only the type of gas and the type of cylinder specified by the manufacturer;
The LP tank used with your patio heater must meet the following requirements:
Purchase LP tanks only with these required measurements:
(31.8cm) (diameter) x 58cm) (tall) with 15kg capacity maximum.
-In case of violent wind particular attention must be taken against tilting of the appliance; Keep the appliance at least 1m from the gas cylinder.
-The injector in this appliance is not removable and the injector is only assembled by manufacture. This appliance is forbidden to convert from one gas pressure to another pressure.
-Do not connect the gas cylinder directly to the appliance without regulator. Use only the type of gas and the type of cylinder specified in the instructions.
A regulator(complies with EN16129:2013 and the national regulation) of the correct pressure corresponding to the appliance category.
Use 30mbar regulator for butane/propane under the category I3B/P(30).
Use 30mbar regulator for butane under the category I3+(28-30/37).
Use 37mbar regulator for propane under the category I3+(28-30/37).
Use 50mbar regulator for butane/propane under the category I3B/P(50).
It's recommended to use flexible hose that approved by EN16436: 2014.
TABLE OF CONTENTS
Caution 1
Heater Stand and Location 2
Gas Requirements 2
Leakage Test 2
Operation and Storage 3
Cleaning and Care 4
Parts and Specifications 4
Assembly Parts and Procedures 6
Problems Check List 10
CAUTION
PLEASEREDCAREFULLYTHEFOLLOWINGSAFETYGUIDELINESBEFOREOPERATION.
- Do not use the patio heater for indoors, as it may cause personal injury or property damage.
- This outdoor heater is not intended to be installed on recreational vehicles and/or boats.
● Installation and repair should be done by a qualified service person. - Improper installation, adjustment, alteration can cause personal injury or property damage.
- Do not attempt to alter the unit in any manner.
● Never replace or substitute the regulator with any regulator other than the factory-suggested replacement. - Do not store or use gasoline or other flammable vapors or liquids in the heater unit.
- The whole gas system, hose, regulator, pilot or burner should be inspected for leaks or damage before use, and at least annually by a qualified service person.
- All leak tests should be done with a soap solution. Never use an open flame to check for leaks.
- Do not use the heater until all connections have been leak tested.
- Turn off the gas valve immediately if smell of gas is detected. Turn Cylinder Valve OFF. If leak is at Hose/Regulator connection: tighten connection and perform another leak test. If bubbles continue appearing should be returned to hose's place of purchase. If leak is at Regulator/Cylinder Valve connection: disconnect, reconnect, and perform another leak check. If you continue to see bubbles after several attempts, cylinder valve is defective and should be returned to cylinder's place of purchase.
- Do not transport heater while it's operating.
- Do not move the heater after it has been turned off until the temperature has cooled down.
- Keep the ventilation opening of the cylinder enclosure free and clear of debris.
- Do not paint the radiant screen, control panel or top canopy reflector.
- Control compartment, burner and circulation air passageways of the heater must be kept clean. Frequent cleaning may be required as necessary.
• The LP tank should be turned off when the heater is not in use.
- Check the heater immediately if any of the following occurs:
- The heater does not reach temperature.
- The burner makes popping noise during use (a slight noise is normal when the burner is extinguished).
- Smell of gas in conjunction with extreme yellow tipping of the burner flames.
- The LP regulator/hose assembly must be located out of pathways where people may trip over it or in area where the hose will not be subject to accidental damage.
● Any guard or other protective device removed for servicing the heater must be replaced before operating the heater.
• Adults and children should stay away from high temperature surface to avoid burns or clothing ignition.
• Children should be carefully supervised when they are in the area of the heater.
● Clothing or other flammable materials should not be hung on the heater or placed on or near the heater.
- To change the gas cylinder in a amply ventilated area, away from any ignition source (candle, cigarettes, other flame producing appliances, ...);
- To check that the regulator seal is correctly fitted and able to fulfill its function showed as photo right;
• To not obstruct the ventilation holes of the cylinder housing;
● To close the gas supply at the valve of the gas cylinder or the regulator after use;
- In the event of gas leakage, the appliance shall not be used or if alight, the gas supply shall be shut off and the appliance shall be investigated and rectified before it is used again;
- To check the hose at least once per month, each time the cylinder is changed, or each time before long time no use. If it shows signs of cracking, splitting or other deterioration it shall be exchanged for new hose of the same length and of the equivalent quality;
● The use of this appliance in enclosed areas can be dangerous and is PROHIBITED;
- Read the instructions before using this appliance. The appliance must be installed in accordance with the instructions and local regulations.
- For connection of hose and regulator, and connection of regulator and hose, please refer to photo showed above.

text_image
seal hose regulator cylinderHose/ Regulator connection and Regulator / Cylinder connection
HEATER STAND AND LOCATION
- The heater is primarily for outdoor use only. Always ensure that adequate fresh air ventilation is provided.
● Always maintain proper clearance to combustible materials, i.e. top 100 cm and sides 100 cm minimum.
● Heater must be placed on level firm ground.
- Never operate heater in an explosive atmosphere like in areas where gasoline or other flammable liquids or vapors are stored.
- To protect heater from strong wind, anchor the base securely to the ground with screws.

text_image
CEILING 100 cm 100 cm WALLFortification of base to the ground

GAS REQUIREMENTS
• Use propane or butane gas only.
● The pressure regulator and hose assembly to be used must conform to local standard codes.
- The installation must conform to local codes, or in the absence of local codes, with the standard for the storage and handling of liquid petroleum gases.
- A dented, rusted or damaged propane tank may be hazardous and should be checked by your tank supplier. Never use a propane tank with a damaged valve connection.
● The propane tank must be arranged to provide for vapor withdrawal from the operating cylinder.
● Never connect an unregulated propane tank to the heater.
LEAKAGE TEST
Gas connections on the heater are leak tested at the factory prior to shipment. A complete gas tightness check must be performed at the installation site due to possible mishandling in shipment or excessive pressure being applied to the heater.
● Make a soap solution of one part liquid detergent and one part water. The soap solution can be applied with a spray bottle, brush or rag. Soap bubbles will appear in case of a leak.
● The heater must be checked with a full cylinder.
● Make sure the safety control valve is in the OFF position.
- Turn the gas supply ON.
- In case of a leak, turn off the gas supply. Tighten any leaking fittings, then turn the gas supply on and re-check.
● Never leak test while smoking.
- Turn on the valve on the gas supply cylinder completely.
- Press and turn the variable control knob to PILOT position (counter-clockwise 90°).
- Press down the variable control knob and hold for 90 seconds. While holding down the variable control knob, press the igniter button several times until the pilot flame lights. Release the variable control knob after the pilot flame lights.
Note:
- If a new tank has just been connected, please allow at least one minute for the air in the gas pipeline to purge out through the pilot hole.
- When lighting the pilot flame make sure that the variable control knob is continuously pressed down while pressing the igniter button. Variable control knob can be released after the pilot flame lights.
- Pilot flame can be watched and checked from the small round window with sliding lid located at the bottom of the flame screen (to the left or right side of the controller).
-
If the pilot flame does not light or it goes out, repeat step 3.
-
After the pilot flame lights, turn the variable control knob to maximum position and leave it there for 5 minutes or more before turning the knob to desired temperature position.
TO TURN OFF THE HEATER
- Turn the variable control knob to PILOT position.
- Press and turn the variable control knob to OFF position.

text_image
Variable control knob PILOT OFF LO Igniter IGNITEROFF: the heater stop work
HI: maximum temperature position
LO: minimum temperature position
- Turn off the valve on the gas supply cylinder completely.
Storage
- Always close the gas valve of the gas cylinder after use or in case of a disturbance.
- Remove the pressure controller and the hose.
- Check the tightness of the gas valve and for damage. If you suspect a damage, have it changed by your gas dealer.
- Never store liquid gas cylinder in a sub-terrain, or at places without adequate air ventilation.
CLEANING AND CARE
- Wipe off powder coated surfaces with soft, moist rag. Do not clean heater with cleaners that are combustible or corrosive.
- Remove debris from the burner to keep it clean and safe for use.
- Cover the burner unit with the optional protective cover when the heater is not in use.
PARTS AND SPECIFICATIONS

text_image
813 mm Reflector Flame screen Burner base Air admittance fence Gas valve controller Base of control housing Post 2003 mm 2222 mm Tank housing 765 mm Post bracket Stand 460 mmA. Construction and characteristics
● Transportable terrace/garden heater with tank housing
● Casing in steel with powder-coating or stainless steel
Gas hose connections with metal clamp (screw caps for Germany)
• Heat emission from reflector
B. Specifications
- Use propane, butane or their mixtures gas only.
• Max. wattage: 13000 watts
• Min. wattage: 5000 watts
Consumption:
| APPLIANCE CATEGORY: | I_3+(28-30/37) | I_3B/P(30) | I_3B/P(50) | I_3B/P(37) | |
| TYPES OF GAS: | Butane Propane | Butane, propane or their mixtures | Butane, propane or their mixtures | Butane, propane or their mixtures | |
| GAS PRESSURE: | 28-30mbar | 37 mbar | 30 mbar 50mbar 37mbar | ||
| OUTLET PRESSURE OF REGULATOR: | 30mbar 37 mbar | 30 mbar | 50mbar 37mbar | ||
- Using the proper regulator according to outlet pressure of regulator as showed in the table above.
C.Tableofinjector
| APPLIANCE CATEGORY: | I_3+(28-30/37) | I_3B/P(30) | I_3B/P(50) | I_3B/P(37) | |
| TYPES OF GAS: | Butane Propane | Butane, propane or their mixtures | Butane, propane or their mixtures | Butane, propane or their mixtures | |
| GAS PRESSURE: | 28-30mbar | 37 mbar | 30 mbar 50mbar 37mbar | ||
| TOTAL HEAT INPUT (Hs): (Qn) | 13kW (G30:945g/h; G31:929g/h) | ||||
| INJECTOR SIZE: | 1.90 mm for main burner0.18 mm for pilot burner | 1.70 mm for main burner0.18 mm for pilot burner | 1.80 mm for main burner0.18 mm for pilot burner | ||
| The marking, for example, 1.90 on the injector, indicates that the size of injector is 1.90mm | |||||
● The hose and regulator assembly must conform to local standard codes.
● Regulator outlet pressure should meet the corresponding gas category in the table of injector.
● The appliance requires approved hose in 1.4m length.
ASSEMBLY PARTS
Tools needed:
- Open end wrench 10 & 13 mm
• Adjustable opening wrench (2) 20 cm long - Slip joint pliers 23 cm long
• Philips screwdriver w/ medium blade - Spray bottle of soap solution for leakage test

text_image
Parts List: A B FF C F D E G H IASSEMBLY PARTS
HARDWARE CONTENTS (shown actual size)

M8
Flange
nut
Qty. 2
Bolt
M8 x 16
Qty. 5
M6
Flange
nut
Qty. 6
Stainless
steel bolt
Qty. 4
Bolt
M6 × 30
Qty. 6
Reflector
spacer
Qty. 3
Washer Φ8
Qty. 9
Washer 6 Qty. 9
Screw
M6 X 10
Qty. 9
Cap nut
Qty. 9
Wing nut
Qty. 3
Wrench
Qty. 1
(not actual
size)
ASSEMBLY PROCEDURES
STEP 1
1-1. Put the 3 pcs post brackets on each position on the base as shown in the picture.
1-2. Use 3 Medium Bolts(M8x16) to join the post brackets and stand.
STEP 1

text_image
Post bracket Bolt StandSTEP 2
2-1. Put the post on the top of 3 pcs post brackets.
2-2. Use 6 Large Bolts and Flange Nuts (M6) to connect the post to the 3 pcs post brackets. Tighten the bolts and nuts.
STEP 2

text_image
Post Bolt NutSTEP 3
Place the tank housing on the stand.
STEP 3

text_image
Tank housingSTEP4
4-1. Remove the 4 bolts from the burner.
4-2. Put the gas hose through into the post.
4-3. Fix the burner unit to the post by the 4 bolts.

text_image
STEP 4 BoltSTEP5
5-1. Check whether the connection of vertical post and burner are assembled according to instructions, and all bolts and nuts are tightened.
5-2. Put 6 pcs Large Flat Washers on 3 Reflector Spacers.

text_image
STEP 5 Reflector SpacerSTEP6
Fasten the reflector with 3 pcs Large Flat Washers and 3 pcs Wing Nuts.

text_image
STEP 6 Wing nut ReflectorSTEP 7
7-1. Bring up the tank housing and rest it on the post plate.
7-2. Connect the end thread of inlet gas hose to the regulator.
7-3. Connect the regulator to the gas tank and tighten it with adjustable wrench.
7-4. Put LPG gas tank on the stand.
7-5. Fasten cylinder with propane tank strap.

text_image
STEP 7 Regulator Gas tankPROBLEMS CHECK LIST
PROBLEM PROBABLE CAUSE SOLUTION
Pilot will not light
Gas valve may be OFF
Turn the gas valve ON
Tank fuel empty Refill LPG tank
Opening blocked Clean or replace opening
Air in supply system Purge air from lines
Loose connections Check all fittings
Pilot will not stay on
Debris around pilot
Clean dirty area
Loose connections Tighten connections
Thermocouple bad Replace thermocouple
Gas leak in line Check connections
Lack of fuel pressure Tank near empty. Refill LPG tank.
Burner will not light
Pressure is low
Tank near empty. Refill LPG tank.
Opening blocked Remove and clean
Control not ON
Turn valve to ON
Thermocouple bad Replace thermocouple
Pilot light assembly bent
Place pilot properly
Not in correct location
Position properly and retry
If the appliance is in case of any defaults or problems of assembly or use, please don't try to modify it by yourself, contact your supplier or distributor to solve it.
PROCEDURE IN CASE OF FAILURE OF AN INFINITON PRODUCT
Dear customers, to request technical assistance or repair of your Infiniton product, you have our website, operating 24 hours a day and 7 days a week:

text_image
QR code image containing encoded data, no visible human-readable textAlternatively, if they wish, they can request technical assistance via email:
info@infiniton.es
rma@infiniton.es
To streamline all procedures, the following information should always be indicated:
- Name and surname
- Telephone 1
- Telephone 2
- Full address
- Postal Code
- Population
- Brand
- Product model
- Serial number
- Failure presented by the product
If they wish, they can request technical assistance through the number 958 087 169, available only for white range products (except for free-standing microwaves).
INFINITION
natural_image
Line drawing of a portable outdoor heating unit with vertical column and circular base (no text or symbols)Keep the instructions for future reference
natural_image
Simple line drawing of a lamp inside a transparent cube (no text or symbols)Fortification of base to the ground

NECESSIDADES DE GÁS
OFF: the heater stop work
HI: maximum temperature position
LO: minimum temperature position
DESLIGUE O FOGÃO
| APPLIANCE CATEGORY: | I_3+(28-30/37) | I_3B/P(30) | I_3B/P(50) | I_3B/P(37) | |
| TYPES OF GAS: | Butane Propane | Butane, propane or their mixtures | Butane, propane or their mixtures | Butane, propane or their mixtures | |
| GAS PRESSURE: | 28-30mbar | 37 mbar | 30 mbar 50mbar 37mbar | ||
| OUTLET PRESSURE OF REGULATOR: | 30mbar 37 mbar | 30 mbar 50mbar 37mbar | |||
| APPLIANCE CATEGORY: | I_3+(28-30/37) | I_3B/P(30) | I_3B/P(50) | I_3B/P(37) | |
| TYPES OF GAS: | Butane Propane | Butane, propane or their mixtures | Butane, propane or their mixtures | Butane, propane or their mixtures | |
| GAS PRESSURE: | 28-30mbar | 37 mbar | 30 mbar 50mbar 37mbar | ||
| TOTAL HEAT INPUT (Hs): (Qn) | 13kW (G30:945g/h; G31:929g/h) | ||||
| INJECTOR SIZE: | 1.90 mm for main burner0.18 mm for pilot burner | 1.70 mm for main burner0.18 mm for pilot burner | 1.80 mm for main burner0.18 mm for pilot burner | ||
| The marking, for example, 1.90 on the injector, indicates that the size of injector is 1.90mm | |||||