USER MANUAL AM-712 Vivotek
VIVOTEK Fixed Dome Series
and compatible accessories
Corresponding part number:
AM-712: 909004720G (v03)
AM-221: 900014801G
AM-118: 900014601G
AM-522: 900020201G
Rev. 1.3
Revision History:
* Rev. 1.0: Initial Release
* Rev. 1.1: Added FD8367-TV, FD8167-T, and FE8180 as the supported models.
* Rev. 1.2: Added corresponding part numbers, and FD8169 as supported model.
* Rev. 1.3: Updated the corresponding part numbers of accessories.
AM-712 Conduit Box Mechanical Drawings

Package Contents
| Item | No. | |
| AM-712 conduit box | Conduit boxItem No. | 1 |
| Screw pack | M3x6 round head w/ washer (nickel and nylok) 7mm; (for securing dome cameras to the base plate) | 5 |
| #6-32 L6 truss head (nickel and nylok) 8mm (for direct installation to a junction box) | 2 | |
| Anchors | 3 | |
| Pan head M4x25, zinc-plated, self-tapping screws (for direct installation to ceiling) | 3 | |
| M3x6 pan washer head | 2 |
Physical Description - Use

flowchart
graph TD
A["100m 100m 100m"] --> B["PoE switch"]
B --> C["AP-FXC-0210 PoE Extender"]
C --> D["100m 100m 100m"]
C --> E["100m 100m 100m"]
C --> F["100m 100m 100m"]
C --> G["100m 100m 100m"]
* The NPT (National Pipe Taper) or PT pipes with male threads are user-supplied.
** The last conduit box does not need to contain a PoE extender.
Physical Description - Top

text_image
For NPT or PT pipe For attaching to juction box For attaching to juction box For 3/4" conduitsPhysical Description - Bottom

text_image
Alignment notch For countersunk head screws| Fixed Dome series | FD8152V, FD816BA-HF2, FD816BA-HT, FD8182-F2, FD8182-T, FD9171-HT, FD9181-HT, FE8180, FD8166A, FD8166A-N |
You may also refer to VIVOTEK's website for the list of supported models. Support for other models can be available through time.

Installation
Mounting Hole Definitions

Above are the locations of different groups of mounting holes for matching different cameras:
| Hole Type | Applicable Cameras Screw No. of screws | ||
| A | FD8137HV/ FD8154V / FD8164V | M3x6 round head | 3 |
| B | FD8137H / FD8154 / FD8164 / FD8169 3 | ||
| C | FD8131V / FD8133V/ FD8134V | 3 | |
| D | FD8131 / FD8133 / FD8134 2 | ||
| E | FD8151V / FD8152V 2 | ||
| F | FD8136 / FD8166 | 2 | |
| G | FE8180 M3x6 pan washer | head | 2 |
| H | FD816BA-HF2, FD816BA-HT, FD8182-F2, FD8182-T, FD9171-HT, FD9181-HT | M3x6 round head | 3 |
| I | FD8367-V / FD8367-TV / FD8338-HV | 3 |
For cabling and configuration details with each network camera, please refer to their documentation.

NOTE:
- The AM-522 is necessary when installing the AM-712 mounting cap to VIVOTEK's standard mounting options such as AM-212 (wall mount bracket) and AM-221 (gooseneck).
The AM-522 features the mounting option for NPT pipes only. - Route cables before you secure the accessories to a wall.
- For details on the cable connections with each camera, please refer to their Quick Installation Guide.
The following mount types do not apply to PT pipes.
Configuration - Pendant Pipe

text_image
AM-118 pendant head AM-522 adapter 3/4" female adapter 3/4" pendent pipe AM-712Note: The 3/4" female adapter and pendant pipes are separately purchased.
Configuration - Gooseneck

text_image
AM-221 gooseneck AM-522 adapter AM-712 7When installing the mounting cap, take note that the orientation of the mounting cap can affect the camera's shooting direction. You may need to disconnect the conduit box from the NPT pipe, rotate, and re-install it for the best orientation.
Configuration - Wall Mount

text_image
AM-212 Wall-mount bracket AM-522 adapter AM-712III-1. Installing Camera to Conduit Box
Refer to the matching table on page 4 for the mounting hole information for your camera.
- Remove the base plate from the bottom of the conduit box.
- You can route cables through other accessories before you install cameras to the base plate.

natural_image
Technical line drawing of a mechanical component with internal features and a circular cross-section showing internal components (no text or symbols)- Orient and install the camera to the base plate (to the side with printed characters).
- Connect cables to the camera.
- Install the base plate to the conduit box.
- Proceed with initial setup such as enabling network access, focus tuning, or zooming. When done, secure the outer dome cover.
Some installation samples are shown below:
The A Screw Holes: FD8154V / FD8137HV / FD8164V

text_image
Technical diagram of a device with labeled components and directional arrows indicating rotation or movement.
NOTE:
Orient the camera so that cables coming out from the camera can pass through the cabling hole on the base plate.
The B Screw Holes: FD8154 / FD8137H / FD8164 / FD8169

natural_image
Technical line drawing of a mechanical assembly with no visible text or symbolsB holes

text_image
Diagram of a circular biological or geological structure with labeled features and directional arrows indicating flow or movement.The C Screw Holes: FD8131V / FD8133V / FD8134V

text_image
M4X12 Screws
text_image
C holes C C C BThe D Screw Holes: FD8131 / FD8133 / FD8134

natural_image
Technical line drawing of a mechanical assembly with no visible text or symbols
text_image
Diagram of a circular device with labeled components and directional arrows indicating movement or flow.
The F Screw Holes: FD8166A / FD8166A-N
F holes

text_image
noles A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A' B' C' D' E' F' G' H' I' J' K' L' M' N' O' P' Q' R' S' T' U' V' W' X' Y' Z' A'
natural_image
Technical line drawing of a mechanical assembly with no visible text or symbolsThe G Screw Holes: FE8180
M3X6 Screws

text_image
Technical diagram showing cable installation and component layout with labeled parts in ChineseThe H Screw Holes: FD816BA-HF2, FD816BA-HT, FD8182-F2, FD8182-T, FD9171-HT, FD9181-HT
M3X0.5 L6 Screws

natural_image
Technical line drawing of a mechanical assembly with no visible text or symbols
text_image
H holes ρ' 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80The I Screw Holes: FD8367 and 8338 Series
M3X0.5 L6 Screws

natural_image
Technical line drawing of an automotive alternator assembly with mounting holes (no text or labels)
text_image
I holes H G G G G H 1III-2. Installing the Pendant Head and Pipe
Below are the sample procedures using a pendant head and pendant pipe:
- Determine a hard surface ceiling location, and use the alignment sticker to mark the positions where holes will be drilled to secure the pendant head. Hammer the anchors into the ceiling.
Note that mounting holes should be 10mm in diameter and 60mm deep. The included screws are M6.2 x75mm.

natural_image
Diagram of a spray gun system with three identical rocket components and a circular component, no text or symbols present.
NOTE:
This mount type applies to NPT pipes only.
For NT pipes, fixture on the other end should be handled by users.
- Install an NPT or PT male thread pipe (length determined by installers) by turning it clockwise to the pendant head, and secure the connection using an included 3mm hex wrench.

text_image
AM-118 pendant head AM-522 adapter 3/4" female adapter 3/4"pendent pipe- Route Ethernet cable and other wires through the pendant head. You may apply a 1 inch conduit.
Note that when routing Ethernet cables, please make sure you have tagged the cables as PoE input (coming from a PoE switch), or PoE output (one that transmit data and power to the next conduit box).
- Secure the pendant head to ceiling by driving screws through its mounting holes. Depending on the length of your cables, you may need the help from your colleague for holding the components.

text_image
Pendant Head CablesIII-3. Installing the Conduit Box and PoE Extender
- Pull cables through the NPT pipes and then the conduit box.
- Install the conduit box to the NPT pipe.
- When done, install the PoE extender by driving 2 screws to the conduit box, its connector side facing the inside of the box.

text_image
You Connector side VIVO TEKYou may use cable tags to identify PoE cables.
- In a cascade topology, there should be 2 Ethernet cables in the pipe. One is used as PoE input, the other as the out port to the next conduit box.

text_image
PoE OUT to another conduit box PoE IN PoE OUT to camera VIVOTEK- Pull the Ethernet cable (and/or I/O wires) through the cabling hole on the base plate.
- Orient the alignment notch with the tab on the conduit box.
- Secure the base plate along with the camera to the conduit box.

text_image
To Camera LAN port Alignment Notch- Install the camera's dome cover.
- Proceed with initial setup such as enabling network access, focus tuning, or zooming.
This page is intentionally left blank.