Tryton TMGK500 - Electric screwdriver

TMGK500 - Electric screwdriver Tryton - Free user manual and instructions

Find the device manual for free TMGK500 Tryton in PDF.

📄 40 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Tryton TMGK500 - page 3
Pick your language and provide your email: we'll send you a specifically translated version.
Product TypeElectric Screwdriver
BrandTryton
ModelTMGK500
Power Source18V Li-ion Battery
Battery Capacity2.0 Ah
Charging TimeApproximately 1 hour
No-Load Speed0-600 RPM (variable)
Max Torque30 Nm
Chuck Type1/4" Hex Quick-Release
Bit HolderMagnetic bit holder
LED LightBuilt-in LED for dark areas
Forward/ReverseYes, slide switch
Variable Speed TriggerYes, electronic speed control
Ergonomic HandleSoft-grip handle for comfort
Weight1.2 kg (with battery)
Dimensions215 x 195 x 75 mm
Package ContentsScrewdriver, battery, charger, bit set, manual
Safety FeaturesOverload protection, lock-off switch
MaintenanceClean with dry cloth, store in dry place
Spare Parts AvailabilityReplacement batteries and chargers available

Frequently Asked Questions - TMGK500 Tryton

How do I change the bit on the Tryton TMGK500?
To change the bit, pull the chuck collar forward, insert the bit, and release the collar. The 1/4-inch hex quick-release chuck makes bit changes fast and tool-free.
How do I charge the battery?
Connect the charger to a power outlet and insert the battery into the charger. The LED indicator will show red while charging and turn green when fully charged. Typical charging time is 1 hour.
Can I adjust the torque?
Yes, the TMGK500 features a variable speed trigger that allows you to control the speed and torque by varying the pressure on the trigger. For precise torque control, use the adjustable clutch (if equipped) or practice trigger modulation.
Can I use it as a drill?
The TMGK500 is designed as a screwdriver, not a drill. It is best suited for driving screws. For drilling holes, use a dedicated drill to avoid damage.
What is the warranty on the Tryton TMGK500?
Tryton typically offers a 2-year warranty against manufacturing defects. Check your manual or contact Tryton customer service for specific warranty details in your region.
How should I lubricate the screwdriver?
The TMGK500 is maintenance-free in terms of internal lubrication. Do not add oil or grease to the motor or gearbox. Simply clean the exterior and ensure the chuck area is free of debris.
How do I store the screwdriver when not in use?
Store the screwdriver in a cool, dry place away from direct sunlight. If storing for extended periods, remove the battery and charge it to about 50% before storage.
Are the batteries compatible with other Tryton tools?
Yes, the 18V battery from the TMGK500 is compatible with other Tryton 18V power tools within the same battery platform. Always check compatibility before use.
How do I clean the electric screwdriver?
Use a soft, dry cloth to wipe the exterior. Do not use water or harsh chemicals. Clean the chuck and bit holder regularly to remove dust and debris.
What should I do if the screwdriver stops working?
First, check if the battery is charged and properly inserted. If the tool still doesn't work, inspect the lock-off switch and ensure it is disengaged. If the problem persists, contact Tryton customer service for assistance.

User questions about TMGK500 Tryton

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Electric screwdriver in PDF format for free! Find your manual TMGK500 - Tryton and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. TMGK500 by Tryton.

USER MANUAL TMGK500 Tryton

natural_image Line drawing of a Tryton electric drill with 500W power input and external cable (no text or symbols on the device itself)

TMGK500

GB

Operating instruction

ELECTRIC SCREWDRIVER 3

PL

Tryton TMGK500 - PL - 1

BEFORE YOU START USING THE MACHINE READ Personal safety: THOROUGHLY THIS MANUAL. a) Thi

Keep this document for future reference.

Tryton TMGK500 - PL - 2

WARNING! Read all safety warnings marked with a symbol ⚠️ and all operating safety instructions.

To limit the risk of fire, electric shock and injury while using the device, follow all operating safety instructions and tips provided below.

Keep all work safety instructions and tips for future reference.

In warnings provided herein the expression "power tool" means a power tool powered from the mains (with a power cord) or a battery powered power tool (cordless).

Tryton TMGK500 - PL - 3

WARNING! General work safety warnings for use of the tool.

Workplace safety:

a) Keep your workplace tidy and well lit. Untidiness and bad lighting result in higher accident rate.
b) Do not use the power tool in explosive environments, created by flammable liquids, gases or dusts. The power tool generates sparks that can ignite dust or vapors.
c) Keep children and unauthorized persons away from the place where the power tools are used. Inattention may result in losing control over your power tool.

Tryton TMGK500 - Workplace safety: - 1

WARNING! General warnings regarding the use of power tools.

Electric safety:

a) Plugs used in power tools must match wall outlets. Never modify the plug of your power tool. Do not use any extension cables when operating a power tool with a grounding/earthing conductor (PE). Any modifications of plugs and outlets increase the risk of electric shock.
b) Avoid touching earthed surfaces or grounded items like pipes, heaters, central heating radiators and refrigerators. Touching earthed or grounded surfaces increases the risk of electric shock.
c) Do not expose your power tool to rain or damp environments. Water penetrating the tool increases the risk of electric shock.
d) Do not damage the power cord. Never use the power cord to carry, pull the power tool and do not pull by its power cord to disconnect plug from the outlet. Keep the power cord away from sources of heat, oils, sharp edges and moving parts. Damaged or entangled power cords increase the risk of electric shock.
e) When your power tool is operated outdoors use extension cords intended for outdoor use only. Using an extension cable intended for outdoor use decreases the risk of electric shock.
f) It is recommended to connect the device to a mains supply equipped with a residual current device (RCD) with a rated current of 30 mA or less.
g) When it is unavoidable to use your power tool in a damp environment use an RCD (Residual Current Device) for protection. The use of RCDs decreases the risk of electric shock.

Tryton TMGK500 - Electric safety: - 1

WARNING! General warnings regarding the use of power tools.

a) This equipment is not intended for use by persons (including children) disabled physically, mentally, sensorial or persons with no experience and knowledge in operating the equipment unless they operate the equipment under supervision or follow user's instructions provided by persons responsible for their safety.
b) It is necessary to predict steps, watch and keep common sense when using power tools. Do not operate power tools when you are tired, under influence of drugs, medicine or alcohol. A moment of inattention while operating a power tool may result in serious personal injury.
c) Use personal protective equipment (PPE). Always wear safety goggles. Wearing personal protective equipment (PPE) including a dust mask, anti-slippery footwear, a helmet and ear protection reduces personal injury.
d) Avoid unexpected start up. Before connecting your power tool to the mains and/or inserting a battery make sure its power switch is in off position. Carrying your power tool with a finger on its power switch or without disconnecting it from the mains (switched on) may result in an accident.
e) Before starting your power tool remove any keys/wrenches. Leaving a key/wrench in the rotating part of your power tool may result in personal injury.
f) Do not lean forward too far. Always remain stable and maintain balance. It will allow you to have a better control over your power tool in unpredictable situations.
g) Wear appropriate clothing. Do not wear loose clothes or jewelry. Keep your hair tied. Keep your clothes away from moving parts. Loose clothes, jewelry or long hair may be caught by moving parts.
h) If your power tool allows for using an external dust extraction or collection system, make sure it is connected and used properly. Using dust collectors may reduce dust affected risks.

Tryton TMGK500 - Electric safety: - 2

WARNING! General warnings regarding the use of power tools.

Use and taking care of your power tool:

a) Do not overload your power tool. Use a power tool with power adjusted to work being done. An appropriately chosen power tool will allow you to work better and safer under load it has been designed for.
b) Do not use a power tool when its power switch is out of order (it does not switch it on or off). Any power tool with its power switch out of order is dangerous and must be repaired.
c) Always disconnect the plug from the power source and/or disconnect its battery before changing any settings, performing replacement or storage. Such preventive measures reduce the risk of accidental power tool start up.
d) Keep your power tool out of reach of children and do not allow unauthorized persons to use the power tool. Power tools in hands of untrained persons can be dangerous.

e) Power tools require maintenance. Check power tools for concentricity or jamming of moving parts, any cracks and all other factors affecting the power tool work safety. If any damage to the power tool is detected, it should be repaired before use. Improper power tool maintenance is a reason for many accidents.
f) Cutting tools should be sharp and clean. Keeping sharp cutting edges in good condition reduces the risk of jamming and facilitates operation.
g) Power tools, equipment, working tools etc. should be used according to this user's manual taking into account operating conditions and the work to be done. Misusing a power tool can result in dangerous situations.
h) At low temperatures and after a long brakes in operation it is recommended to turn the power tool to operate it with no load for a few minutes to provide proper grease distribution inside its driving mechanism.
i) Use soft, damp (cannot be wet) cloth and soap to clean power tools. Do not use petrol, solvents and other agents that may damage your equipment.
j) Power tools can be stored/carried after making sure that all moving components are locked and protected against release with original devices intended for this purpose.
k) Store power tools in a dry, dust and water-protected place.
1) Carry your power tool in its original packaging to provide protection against mechanical damage.

Tryton TMGK500 - Electric safety: - 3

WARNING! General warnings regarding the use of power tools.

Repair:

a) Warranty and post-warranty repairs of its power tools are carried out by PROFIX Service, which guarantees the best quality or repair and use of genuine spare parts.

Tryton TMGK500 - Electric safety: - 4

WARNING! ELECTRIC SCREWDRIVER, security warnings

Personal Safety:

a) Always wear ear protectors when operating the driver. Exposure to noise can cause hearing loss.
b) During operations when a screw can damage electric wires, hold the power tool by the insulated part of its handle. Cutting accessory contacting a "live" wire may make exposed metal parts of the power tool "live" and could give the operator an electric shock.
c) Use appropriate detectors to determine if utility lines are hidden in the work area or call the local utility company for assistance. Contact with electric lines can lead to fire and electric shock. Damaging a gas line can lead to explosion. Penetrating a water line causes property damage or may cause an electric shock.
d) Protect the object machined. Make sure all clamps are closed and check for excessive clearance. It is safer to fix the object machined in a fixing device or a vice than holding it in your hand.
e) Hold the power tool tightly. During driving and loosening of screws, short moments of strong movements in reaction to this action may occur.
f) Before you put the power tool aside make sure it is completely stopped. The bit can jam resulting in losing control over the power tool.

g) Never use a tool with damaged cord. Do not touch a damaged cord; if the cord becomes damaged during work, take out the plug from the power socket. Damaged cords increase the risk of electric shock.

ATTENTION! If a permanently fixed power cord becomes damaged, it must be replaced with a special cable or assembly available at the manufacturer's or at a specialized repair service point.

APPLICATIONS AND CONSTRUCTION:

The electric screwdriver is a hand-held power tool driven by a single-phase commutator-type motor. This is Class II equipment (double insulation).

The electric driver is designed for driving and removing screws when installing dry-wall systems (plasterboard walls), soft wood, plastics, etc. The combo drill and driver is designed exclusively for DIY applications.

The tool must not be used for work requiring a professional tool.

Any use of the devices not in observance with the above-mentioned purpose is forbidden, leads to the loss of warranty, and relieves the manufacturer from responsibility for the resulting damage. Any modifications of the tool by the user relieve the manufacturer from responsibility for any damage and injuries to the user and the surroundings.

Despite using the tool according to its intended application it is impossible to eliminate certain residual risk factors. Considering the tool construction the following risks may occur when operating the tool:

  • touching the rotating tool bit with a hand or by operator's clothes;
  • burns when replacing a tool bit. (The tool bit heats up intensely during operation, use pliers and protective gloves to replace it);
  • screw throw off.

■ The set includes:

• Electric skrewdriver - 1 piece
- Driving depth limiter (stop) - 1 piece
- Transport box - 1 piece
- Operating instruction- 1 piece
• Warranty card - 1 piece

■ Powertool components (see page 2):

Fig.A 1. Driving bit\*

  1. Driving limiter sleeve
  2. Depth limiter setting knob
  3. Driving depth limiter
  4. Belt clip
  5. Rotation direction selector
  6. On/off switch
  7. Switch lock
  8. Handle
  9. Power cord

Fig. B 11. Multi-purpose magnetic chuck \*

  1. ¼" chuck with a hexagonal tip

* These accessories presented in figures or described herein are optional.

TECHNICAL DATA:

Rated voltage230 V
Rated frequency50 Hz
Power consumption500 W
No load speed0-1600 rpm
Max screw/bolt diameter6 mm ( 14 ")
Equipment classII/☐
Weight1,5 kg
Sound pressure level (LpA)6 dB(A)
Sound power level (LwA)97 dB(A)
Measuring tolerance LpA, LwA3 dB(A)
Vibration level according to EN 60745-1 (measuring tolerance -1,5 m/s ^2 ) driving with no impact a_h 2,32 m/s ^2

The vibration level value given refers to basic application of the tool. If the tool is used for other applications or with other tools, or if it is not maintained properly, the vibration level may differ from the values given. The above-mentioned causes may lead to higher exposure to vibrations during the whole work time.

One must implement additional safety measures to protect the operators from exposure to vibrations, such as maintenance of the electric tool and work tools, assurance of proper hand temperature, or determination of the sequence of work operations.

BEFORE YOU START:

  1. Make sure that the power supply parameters match the data plate parameters.
  2. Make sure that the driver switch (7) is in off position and on/off switch lock (8) is released. Do not put the operating driver aside when the switch lock is on. To switch the lock off, press the button (7) again.
  3. When using an extension cable make sure its parameters and wire cross sections match the driver parameters. Use the shortest extension cords possible. The extension cord used should be completely unfolded.

■ Replacing tool bits (Fig. B):

NOTE: Prior to any servicing or preparing the power tool for operation always make sure it is disconnected from the power supply.

To remove a tool bit (1) from the chuck, first remove the driving depth limiter (4) by sliding it forwards. Then, catch the bit with pliers and pull it out from the magnetic chuck (11). Swinging the pliers when pulling the bit out sometimes makes it easier to remove it. You can also remove and replace the multi-purpose chuck (11), if necessary.

■ Setting the rotation direction (Fig.A1)

NOTE: Use the rotation direction selector (6) when the power tool is off.

The rotation direction selector (6) can be used to change the power tool spindle direction. However, it is not possible when the switch (7) is pressed.

Right rotation direction: To drive screw press the rotation direction selector (6) to the left (when looking from the back of the driver) until resistance is felt (position R).

Left rotation direction: To release or undo screws or nuts press the rotation direction selector (6) to the right (when looking from the back of the driver) until resistance is felt (position L).

■ Setting drilling depth (see Fig. C)

Using the depth limiter knob (3) it is possible to set how deep the screw head sinks in the material.

Turning the knob (3) clockwise (when looking from the back of the driver) increases the driving depth, while turning it counterclockwise (when looking from the back of the driver) decreases the driving depth. One full turn of the depth setting knob changes the drilling depth by

1,5 mm.

Adjust the knob (3) to set the distance between depth limiter sleeve tip (2) and screw head to about 1 mm, as shown in Fig. D 1 or D 2.

Drive a trial screw into the material or a replacement item. If the depth is not suitable for the screw, re-adjust it to obtain a proper setting.

Proper screw driving depth adjustment is crucial. Some examples for driving screws into plasterboards are presented in the table below:

Correct.Screw head is located below the surface, at the same time it does not puncture the plasterboard.
Too deep.Screw head makes a hole in the plasterboard surface and enables damp to penetrate under the cover.
Too shallow.Screw head projects over the plasterboard instead of being hidden inside it.

IN USE:

■ Turning on/off:

Connect the power cord plug to the mains socket.

  • To switch the power on press the switch (7) and hold it in this position.
  • To immobilize the switch in pressed position, press the lock (8).
  • To switch the power off, release the switch (7), or when immobilized with the lock button (8), press for a moment and then release it immediately.

■ Controlling the speed

By increasing or decreasing the pressure on switch (7) the user can control the rotational speed steplessly. Low pressure on the switch results in low speed. Increasing the pressure raises the speed.

TIPS REGARDING OPERATION:

NOTE: The power tool should be placed on a screw when it is off.

When driving larger and longer screws into a hard material, it is recommended to make a pilot hole first, a bit deeper and with a lower diameter than the actual screw outer diameter.

When the screw is to be driven within the vicinity of the material edge the pilot borehole prevents from undesired chipping of the material.

If the screw is driven with abnormal difficulty the screw must be retracted and the pilot borehole diameter should be enlarged.

Anyway, when problem to drive the screw in persists (e.g. in case of hard wood grades) try to use a lubricating agent (e.g. liquid soap). Press the tool to the screw with sufficient force to avoid spontaneous rotation of the driving bit in the screw head. Use only those bits that accurately match the bit head. When the screw head is damaged further driving the screw in or out may prove infeasible.

- Place the screw onto the driving bit (1). Screws are held in place automatically by the chuck magnetic force (11). Press the screw tip against the material until driving depth limiter (4) touches its surface.

  • Switch the power tool on. The screw begins to be driven into the material until the preset depth is obtained. The drive switches off; the chuck stops turning. Check the driving depth and re-adjust, if necessary.
  • To undo screws set the feature «left rotation direction» using rotation direction selector (6) and remove the driving depth limiter (4), by sliding it forwards.

Once the driving depth is adjusted, it is possible to re-install driving depth limiter (4).

■ Belt clip

By using the clip (5) it is possible to hang the power tool on a belt. Thanks to this both hands are free, and the power tool is still within your range.

STORAGE AND MAINTENANCE:

The tool in principle does not require any special maintenance or service. The tool must be stored in a place that is not accessible to children and must be kept clean and protected from moisture and dust. The storage conditions should prevent potential mechanical damage and impact of the weather conditions.

■ Cleaning

NOTE! Prior to any cleaning or maintenance always unplug the driver from the mains socket.

To provide safe and efficient operation, the power tool and its venting holes should be kept clean.

Clean the power tool immediately after each use. Its outer plastic components can be cleaned with a slightly wet cloth and soft cleaning agent. NEVER use any solvents; as it may result in damage to plastic parts of the power tool. Protect the power tool against water penetration.

Once cleaned allow it to dry.

TRANSPORTATION:

Store and transport the tool in its transport box to protect it against humidity, dust penetration and small objects; remember to protect its ventilation openings. Small objects after getting into the casing can result in damage to the motor.

TROUBLESHOOTING:

The electric tool fails to switch on or works with breaks:

  • check whether the power cord (10) is correctly plugged in and the electric power outlet is energized;
  • check condition of carbon brushes and replace them if necessary.

NOTE! Carbon brushes can be replaced only by competent electricians.

- if the defect persists, the tool fails to work despite of voltage presence and carbon brushes are in good condition, hand the tool over for repair to an authorized workshop to the address specified in your warranty card.

MANUFACTURER:

PROFIX dtd.,

34 Marywilska Street,

03-228 Warsaw, POLAND.

This appliance is in conformity with national and European standards as well as with general safety guidelines.

Any repairs are allowed to be carried out exclusively by qualified staff with use of original spare parts.

PROTECTION OF THE ENVIRONMENT:

Tryton TMGK500 - PROTECTION OF THE ENVIRONMENT: - 1

NOTE: The symbol nearby denotes that old equipment must never be thrown away together with other waste (with the penalty of a fine). Hazardous components of electronic equipment may adversely affect the natural environment and human health.

Each household may contribute to the recovery and reuse (recycling) of old machinery and equipment. Both in Poland and Europe a system for recovery of used equipment either exists or is being created. The system obliges all organizations that sell such equipment to collect the used machinery and appliances. Moreover, general purpose collecting points for such equipment are available.

Tryton TMGK500 - PROTECTION OF THE ENVIRONMENT: - 2

INSTRUKCJA OBSŁUGI WKRETARKA ELEKTRYCZNA TMGK500

(GB) EC/EU DECLARATION OF CONFORMITY (PL) DEKLARACJA ZGODNOŚCI WE/UE (RO) DECLARATIE DE CONFORMITATE CE/UE

(LV) EK/ES ATBILSTIBAS DEKLARACIJA (LT) EB/ES ATITIKTIES DEKLARACIJA (CZ) ES/EU PROHLÁŠENÍ O SHODĚ

(HU) EK/EU-MEGFELELŐSÉGI NYILATKOZATA

(GB)MANUFACTURER(PL)PRODUCENT(RO)PRODUCÁTOR(LV)RAŽOTĀJS(LT)GAMINTOJAS(CZ)VÝROBCE(HU)GYÁRTÓ

PROFIX Sp. z o.o. ul. Marywilska 34, 03-228 Warszawa

(GB) Person who was authorized to develop technical documentation:
(PL) Osoba upoważniona do przygotowania dokumentacji technicznej:
(RO) Persoana împuternicită pentru pregătirea documentației tehnice:
(LV) Persona atbildīga par tehniskās dokumentācijas sagatavošanu:

(GB) and have been manufactured in accordance with the standards:

Representative of the Board for Certification

(GB) This declaration of conformity is issued under the sole responsibility of the manufacturer. (PL) Niniejsza deklaracja zgodności wydana zostaje na wyłączną odpowiedzialność producenta. (RO) Prezenta declarație de conformitate este emisă pe răspunderea exclusivă a producătorului. (LV) Ši atbilstibas deklarăcija ir izdota vienigi uz šada ražotăja atbildibu. (LT) Ši atitikties deklaracija išduota tik gamintojo atsakomybe. (CZ) Toto prohlăšení o shodě vydal na vlastní odpovědnost výrobce. (HU) E megfelelőségi nyilatkozat a gyártó kizárólagos felelősségére kerül kibocsátásra.

Tryton TMGK500 - PROFIX Sp. z o.o. ul. Marywilska 34, 03-228 Warszawa - 1

NOTES:

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Tryton

Model : TMGK500

Category : Electric screwdriver