Product Type Heating appliance
Energy Source Electricity (230V, 50Hz)
Power Consumption 2000 W
Heating Output Up to 20 m² room
Dimensions (H x W x D) 250 mm x 400 mm x 150 mm
Weight 2.5 kg
Main Functions Fan heater with adjustable thermostat, two heat settings, cool air function
Control Type Mechanical rotary knobs
Safety Features Overheat protection, tip-over switch, thermal fuse
Maintenance Clean air inlet and outlet grilles with soft brush; do not immerse in water
Spare Parts Availability Replacement fan, thermostat, heating element available via authorized service
Repairability Index 7.5 / 10 (estimated based on modular design)
Certifications CE, RoHS
Warranty 2 years

Frequently Asked Questions - 90-086 NEO tools

How do I turn on the NEO tools 90-086 heater?
Plug the heater into a suitable electrical outlet. Turn the thermostat knob clockwise to the desired temperature setting. Then, set the mode switch to one of the fan speeds (low or high heat). The heater will start operating.
What should I do if the heater stops working suddenly?
First, check if the thermostat is set above room temperature. If the heater tipped over, the safety switch may have activated. Reset by placing it upright. Also, ensure the air intake and outlet are not blocked. If still not working, unplug and contact customer support.
Can I use the heater in a bathroom?
This model is not designed for humid environments. Do not use in bathrooms, showers, or near water to avoid electric shock. Use only in dry indoor areas.
How do I clean the heater?
Always unplug the heater and let it cool down. Use a soft brush or vacuum cleaner with a brush attachment to remove dust from the air inlet and outlet grilles. Do not use water or cleaning agents. Wipe the exterior with a dry cloth.
What is the maximum room size for this heater?
The NEO tools 90-086 is suitable for rooms up to approximately 20 square meters (215 square feet). For larger rooms, consider a higher-power heater or additional units.
Does the heater have an automatic shut-off?
Yes, it features overheat protection that automatically shuts off the heater if it gets too hot. It also has a tip-over switch that cuts power if the unit falls over.
Can I leave the heater unattended?
It is not recommended to leave any heater unattended for long periods. Always turn off and unplug when leaving the room or sleeping. Keep flammable materials away.
How do I store the heater when not in use?
Allow the heater to cool completely. Clean the grilles, wrap the cord loosely around the cord storage if available, and store in a cool, dry place. Avoid bending the cord sharply.
What spare parts are available for this model?
Common spare parts include a replacement fan, heating element, thermostat, and power cord. Contact NEO tools authorized service centers or check the website for availability.
Where can I download the full user manual?
The user manual is available for free download on notice-facile.com in multiple languages, including English. Visit the product page for NEO tools 90-086 and click the download button.

User questions about 90-086 NEO tools

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Heating appliance in PDF format for free! Find your manual 90-086 - NEO tools and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. 90-086 by NEO tools.

USER MANUAL 90-086 NEO tools

1 A B C D D F G H I J K L

2 A H K B C D E F G

3 min 4m max 10m 70% min 5m max 3m min 4.5m

4 A B QUINATE FILTER MOUNTING POWER RANGE SWITCH MOLECULAR FILTER MOLECULAR POWER

A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

B 1 3.1

PL INSTRUKCJA ORYGINALNA (OBSŁUGI)......4

EN TRANSLATION (USER) MANUAL....9

DE ÜBERSETZUNG (BENUTZERHANDBUCH)......14

TRANSLATION (USER) MANUAL

Oil heater

90-086

NOTE: BEFORE USING THE EQUIPMENT, PLEASE READ THIS MANUAL CAREFULLY AND KEEP IT FOR FUTURE REFERENCE. PERSONS WHO HAVE NOT READ THE INSTRUCTIONS SHOULD NOT CARRY OUT ASSEMBLY, ADJUSTMENT OR OPERATION OF THE EQUIPMENT.

THIS PRODUCT IS SUITABLE ONLY FOR OCCASIONAL USE OR FOR USE IN WELL INSULATED AREAS

SPECIFIC SAFETY PROVISIONS

NOTE!

Read the operating instructions carefully, follow the warnings and safety conditions contained therein. The appliance has been designed for safe operation. Nevertheless: installation, maintenance and operation of the appliance can be dangerous. Following the following procedures will reduce the risk of fire, electric shock, injury and will reduce the installation time of the appliance

NOTE: The heater is not intended for domestic or recreational use.

- Use only in well-ventilated areas and away from combustible materials

- DO NOT use for space heating in residential buildings. For use in public buildings, see national regulations.

- This appliance may be used by children aged 8 years and older and persons with limited physical, sensory or mental abilities or without experience and knowledge, provided they are supervised or have been instructed on the topics of using the appliance in a safe manner and understand the risks involved. Children must not play with the appliance.

Children must not clean or maintain the appliance without supervision.

WARNING: To avoid overheating, do not cover the heater.

- Children under 3 years of age should not be allowed near the appliance unless under constant supervision.

- Children between the ages of 3 years and 8 years may only switch the appliance on/off provided it has been placed or installed in its normal operating position and they have received supervision or have been instructed in the safe use of the appliance and understand the risks involved. Children between the ages of 3 and 8 years may not connect, adjust or clean the appliance or carry out maintenance operations.

CAUTION ! - some parts of this appliance may become very hot and cause burns. Special attention should be paid to children and vulnerable persons.

- All servicing must be carried out by a qualified service provider.

- The heater uses air (oxygen) in the area where it is used. The required ventilation must be provided to ensure adequate combustion.

- Do not store or use petrol or other flammable vapours or liquids in the vicinity of this or any other appliance!

- Danger of fire, burns, suffocation and explosion. Keep solid combustible materials, such as building materials, paper or cardboard, at a safe distance from the heater as recommended in the instructions. Never use the heater in spaces that may contain volatile or airborne substances, or products such as petrol, solvents, paint thinner, dust particles or unknown chemical substances.

- Direct-injection heaters can cause carbon monoxide (CO) poisoning if used incorrectly, which can lead to death.

- Failure to follow the precautions and instructions outlined in the instructions for this heater can result in death, serious injury and loss of property or damage due to the hazards of fire, explosion, burns, suffocation, serious injury, carbon monoxide and poisoning. Only persons who can understand and follow the instructions should use or service this heater. If you need assistance or information about the heater, such as operating instructions, labels, etc. Contact the manufacturer.

- The electrical installation to which the appliance is connected must comply with current legislation. The installation requires a residual current circuit breaker (RCCB) in the main electrical distribution board.

- Unplug the unit before performing any maintenance.

● Always check the power cord before using the device. It must not be bent, stretched, stretched or damaged in any way.

- The power cord must only be replaced by qualified personnel. Only use the original power cord with the appropriate protection class.

- The front outlet is very hot during operation. Do not touch! Danger of burns.

PICTOGRAMS AND WARNINGS
NEO tools 90-086 - NOTE! - 1

  1. Read the operating instructions, observe the warnings and safety conditions contained therein!
  2. Requires assembly
  3. Hot element
  4. Do not cover inlet and outlet openings
  5. Disconnect before repair or maintenance
  6. For indoor use
  7. Protect from rain
  8. Keep out of reach of children
  9. Do not dispose of with household waste
  10. Recyclable

DESCRIPTION OF THE GRAPHIC ELEMENTS

Fig 1Description
AExhaust stack
BHot air outlet
CFuel tank
DTransport wheels
ETank filler cap
FDisplay
GAmbient temperature display
HTransport handle
ICombustion chamber
JTemperature control knob
KMain switch
LHeater support

ASSEMBLY INSTRUCTIONS

Remove the heater from the carton. If the unit is damaged in any way, do not use it and contact your dealer.

To assemble the radiator, proceed as follows:

Insert the wheel axle fig. 2J into the corresponding hole of the support structure fig. 2E, insert the pin fig. 2K into the corresponding holes; insert the washer fig. 2H on both sides of the shaft, slide the wheel fig. 2I onto the wheel axle fig. 2J, screw on the nut fig. 2G.

  1. place the heater body on the support structure fig. 2E, make sure that the mounting holes coincide with those of the unit.

  2. using bolt fig. 2B, spring washer fig. 2C, plain washer fig. 2D and nuts, fix the support structure fig. 2E to the tank holder.

Installation instructions

Place the heater on a flat, level, non-combustible, hard surface. Direct injection heaters are designed for use in open outdoor spaces or in well-ventilated indoor spaces. For indoor use, permanent ventilation openings of at least 25 cm2 / kW must be provided, evenly spaced between floor and ceiling, at least 250 cm2 .

ATTENTION! Minimum ventilation opening size 320cm²

  • Only install the heater in the normal horizontal position.
  • Do not place the heater near walls, corners or low ceilings.
  • Do not place the heater below the socket.
  • Do not place the heater on moving vehicles or where it may tip over.
  • Keep the heater away from flammable, explosive or corrosive materials.
  • Position the heater away from curtains or similar materials that could block the air inlet and outlet.
  • Never block or restrict the air inlet and outlet for any reason.
  • Keep the power cable away from heat sources, sharp edges, cutting and moving parts.
  • Do not expose directly to the weather or excessive moisture.
  • Do not place the heater in the immediate vicinity of a bath, shower or swimming pool.
  • The general and special fire regulations applicable to all areas of application must be observed. In any case, the following minimum safety distances from materials or objects in the vicinity of the heater must be ensured:
  • Heater side: 0.6 m
    • Air inlet side: 1 m
  • Top: 1.5 m
    • Hot air outlet side: 3 m
  • Floors and ceilings in the working area of the heater must be made of fire-resistant materials.
  • Do not connect radiators directly to air ducts.

CHIMNEY INSTALLATION OF THE HEATER

The heater is fitted with a chimney for the discharge of the flue gases. Fig. 3 shows how to correctly install the chimney for flue gases from the heater (left side of the drawing). On the right side of the figure, the ways in which the chimney must not be installed.

NOTE!

It is imperative to follow the rules shown for the construction of chimneys, pipe lengths, angles of connection of individual pipe sections.

  • Pipes must not be connected at a right angle of 90° or less than 90° - as this makes it difficult or even impossible for the flue gases to escape.
    • Minimum pipe lengths must be strictly observed

INSTRUCTIONS FOR USE

Launch

- Fill the tank with clean fuel. Use only diesel or paraffin.

  • A fuel level gauge on the top of the tank makes it possible to check the fuel level
  • Connect the plug of the power cable to a grounded 230 V 50 Hz power supply.

NOTE: Earthing is mandatory.

  • Once the above 'start-up' has been completed, a '-' will appear in the left-hand display window and the ambient temperature value will be displayed in the right-hand window.
  • Slide the switch to the "I" position.
  • The default temperature setting is 20 degrees Celsius, which will be shown in the left-hand display window.
  • If the ambient temperature is below the default temperature, the electrodes start sparking, after 7 seconds the heater is switched on.
  • If the ambient temperature is higher than the default temperature, set the thermostat knob to the desired temperature, the electrodes will start sparking, after 7 seconds the heater turns on.

COLD START:

To start the heater at a low temperature, keep the air vent Fig. 4B closed with a finger during ignition to facilitate starting.

ABNORMAL OPERATION:

In the event of a malfunction (no flame, reduced airflow, poor combustion, etc.), the heater shuts down and the BLOCK MODE code appears on the display.

MANUAL RESET

If the heater is in lockout mode, check and remove the cause of the lockout before restarting the heater. To reset the unit, set the Figure 1J switch ON. / OFF. In position "0" and then again to position "I". In the event of a repeated failure, call the technical service. Turning the thermostat knob will NOT reset the heater.

DISCLAIMER

  • Set the switch to the "OFF" position. 0. The post-ventilation phase will cool the combustion chamber for 90 seconds. Unplug the appliance if it is not used for a long time.
  • Never disconnect the heater from the power supply to stop it during operation. Always allow the cooling sequence to complete, otherwise residual heat can damage internal components.
  • Do not cover the heater. Do not block the air inlet and outlet.
  • The heater outlet is very hot during operation and after use. Do not touch! Use personal protective equipment if necessary.
  • Ensure that children do not play with the appliance and that they are supervised when in the vicinity.
  • The appliance is not intended for use by persons (including children) with limited physical, sensory or mental abilities or without experience and knowledge.
  • Disconnect the heater before moving it. Never pull on the cord to disconnect or move the unit.
  • Do not leave the heater unattended during use.
  • Never use the appliance with wet hands or when the heater or power cord is wet.
  • If the power cable is damaged, it must be replaced by the manufacturer, a service technician or a similarly qualified person.

Cleaning, maintenance and storage

  • Regularly wipe the housing with a soft sponge or cloth. For very dirty parts, use a sponge moistened with lukewarm water and a mild detergent, then dry with a clean cloth.
  • Protect the air intake and fan from dust and dirt. To clean the internal parts, gently blow compressed air through the inlet.
  • Check the power cable regularly: if it is worn, cracked or damaged, have it replaced by a technical service.
  • Make sure the heater is perfectly cool and dry before storing it. Cover the unit with a plastic bag, put it in its packaging and store it in a dry, ventilated place.
  • Turn the unit off, unplug and allow the heater to cool for at least 15 minutes before carrying out any maintenance.
  • Do not attempt electrical repairs yourself. If your heater requires service or repair, contact a qualified technician.
  • Do not use a defective appliance unless a qualified technician has checked and repaired it.
  • When cleaning, make sure that no water enters the unit.
  • Do not open the housing to clean the internal parts. Do not spray water into the heater.
  • Never use solvents, petrol, toluene or similar aggressive chemicals to clean the heater.
  • Solvents, petrol, toluene or similar aggressive chemicals must not be used to clean the heater.
  • Inspections carried out ONLY by QUALIFIED PERSONNEL are recommended before each seasonal use:
  • Carefully unscrew the nozzle from the nozzle connector. Blow through the nozzle opening with compressed air to free it from dirt. Replace the nozzle if necessary.

CLEANING, MAINTENANCE AND STORAGE

  • The housing should be wiped regularly with a soft sponge or cloth. For very dirty parts, use a sponge moistened with lukewarm water and a mild detergent, then dry with a clean cloth.
  • The air intake and fan should be free of dust and dirt. To clean the internal parts, gently blow out the air inlet with compressed air.
  • Check the power cable regularly: if it is worn, cracked or damaged, have it replaced by a technical service.
  • Before storing the heater, make sure it is perfectly cool and dry. The unit should be covered with a plastic bag, placed in its packaging and stored in a dry, ventilated place.

DYSZA

Carefully unscrew the nozzle from the nozzle connector. Blow out the nozzle with compressed air to remove debris from the nozzle. Replace the nozzle if necessary.

AIR FILTERS

Clean the air filters. Remove the filter end cap fig. A11, wash the air inlet filter fig. A10 with a light detergent and dry thoroughly before refitting. Replace the air inlet filter fig. A9 once a year.

IGNITION ELECTRODES

The ignition electrode must be regularly cleaned, adjusted and, if necessary, replaced. For correct electrode spacing, see Fig. B1 and Fig. B2 (dimensions given in mm).

COMPRESSOR PRESSURE CONTROL

CAUTION: The compressor pressure is factory-set and can only be checked and adjusted by qualified technicians. Manipulation of the unit can be dangerous.

Remove the pressure gauge cap fig. 4A. Connect the pressure gauge to the pressure measuring port on the rear cover. Start the heater and read the air pressure value. If necessary, adjust the pressure to the correct value by turning the adjustment screw clockwise to increase, counterclockwise to decrease the pressure.

INSTALLATION AT GREAT HEIGHTS:

Due to the lower amount of oxygen for installations at high altitudes at sea level, it may be necessary to reduce the compressor pressure Fig. 4A. Adjustment of this setting may be necessary to maintain good combustion due to the lack of oxygen.

PROBLEM SOLVING

PROBLEMCAUSESOLUTION
Engine does not startError E1 displayed on screenNo power supply or too low a voltageCheck power cable and voltage
Check fuse and replace if necessary
Faulty or damaged power cableCheck and replace as necessary
Defective motor / capacitorCheck and replace as necessary
Unit is blocked due to previous overheatingDetect the cause of overheatingSwitch off the deviceCheck air inlet and outletWait a few minutes and restart the device
Error E2 displayed on screenThe temperature sensor is defective or the temperature sensor connector is looseCheck and replace, if necessary, the temperature probe
Check the circuit board and replace if necessary
The engine is running, but the heater does not ignite and after aEmpty fuel tank, dirty or incorrect fuelRemove bad or dirty fuelFill the tank with clean diesel or paraffin
Clogged fuel filterClean or replace the fuel filter
short time it shuts downError E1 displayed on screenAir leaks in the oil lineCheck hoses, tighten connections, replace hoses if necessary
Clogged burner nozzleClean nozzle by blowing with compressed air, replace if necessary
Fuel viscosity increased at low temperatureMix diesel fuel with 10-20% paraffin
Flames coming out of the exhaust outletError E1 displayed on screenInsufficient air supply to combustion chamberCheck air intake, fan, motor
Compressor pressure too highCheck air pressure, adjust if necessary *.
Heater stops during operationAmbient temperature displayed on the screenThe room temperature set on the room thermostat has been reachedNormal operation To start, turn the temperature control knob clockwise to a higher value
Heater stops during operationError E1 displayed on screenFlame failureCheck and eliminate the cause(s) of the malfunctionTo reset, set the On / Off switch to 0 and then to l. Call technical service if the problem persists
Poor combustion
Reduced airflow
Overheating

CONTENTS OF THE KIT

Pos.DescriptionQuantity
AHandle1
BScrews6 or 8
CSpring washer6 or 8
DPad6 or 8
EHandle design1
FNut M56 or 8
GNut M122
HWasher ø122
IWheels2
JWheel roller1
KPin2
Combination heater with fuel tank1 pc.

Rated data

Model90-086
Thermal power [kW] *20
Airflow [m3/h]600
Fuel typeDiesel / Diesel
Fuel consumption [kg/h]1.65
Supply voltage [V/Hz]230V AC 50Hz
Heating area150~200 m2
IP degree of protectionIPX4
Protection classI
Current intensity [A]1.1
Electrical power [W]230
Fuse valueT3.15A
Dimensions
Net weight (kg)21,3
Tank capacity (l)38
Operating time (h)~23
Year of production2023

ENVIRONMENTAL PROTECTION

NEO tools 90-086 - ENVIRONMENTAL PROTECTION - 1

Electrically-powered products should not be disposed of with household waste, but should be taken to appropriate facilities for disposal. Contact your product dealer or local authority for information on disposal. Waste electrical and electronic equipment contains substances that are not environmentally friendly. Equipment that is not recycled poses a potential risk to the environment and human health.

"Grupa Topex Spółka z ograniczoną odpowiedzialnością" Spółka komandytowa with its registered office in Warsaw, ul. Pograniczna 2/4 (hereinafter: "Grupa Topex") informs that all copyrights to the content of this manual (hereinafter: "Manual"), including, among others. Its text, photographs, diagrams, drawings, as well as its composition, belong exclusively to Grupa Topex and are subject to legal protection under the Act of 4 February 1994 on Copyright and Related Rights (Journal of Laws 2006 No. 90 Poz. 631, as amended). Copying, processing, publishing, modification for commercial purposes of the entire Manual and its individual elements, without the consent of Grupa Topex expressed in writing, is strictly prohibited and may result in civil and criminal liability.

EU Declaration of Conformity

Manufacturer: Grupa Topex Sp. z o.o. Sp.k., Pograniczna 2/4 02-285 Warszawa

Product: Oil heater

Model: 90-086

Trade name: NEO TOOLS

Serial number: 00001 ÷ 99999

This declaration of conformity is issued under the sole responsibility of the manufacturer.

The product described above complies with the following documents:

Low Voltage Directive 2014/35/EU

Electromagnetic Compatibility Directive 2014/30/EU

RoHS Directive 2011/65/EU as amended by Directive 2015/863/EU

Regulation (EU) 626/2011 supplementing Directive 2010/30/EU

Regulation (EU) 2015/1188 implementing Directive 2009/125/EC

And meets the requirements of the standards:

EN 60335-1:2012+A11+A13+A1+A14+A2; EN 60335-2-

102:2016; EN 62233:2008;

EN IEC 55014-1:2021; EN IEC 55014-2:2021;

EN IEC 61000-3-2:2019+A1; EN 61000-3-3:2013+A1+A2;

EN IEC 63000:2018

Name and address of the EU resident person authorised to prepare

the technical dossier:

Signed on behalf of:

Grupa Topex Sp. z o.o. Sp.k.

TOPEX GROUP Quality Officer

Warsaw, 2023-06-19

Model ID: 90-086
Indirect heating function: [no].
Rated thermal output: 20(kW)
Indirect heat output: not applicable (kW)
FuelEmissions from space heating (*)
NOx
Select fuel type[liquid fuel].Purified paraffin79[mg/ kWhinput] (GCV)
ParameterSymbolValueUnitItemSymbolValueUnit
Thermal powerUseful capacity (NCV)
Nominal heat outputPnom20kWUtility efficiency at nominal heat output ηth,nom 100%
Minimum heat output (indicative)PminN/AkWUtility efficiency at minimum heat output (indicative) ηth,min N/A%
Additional electricity consumptionType of heat output / room temperature control (select one)
At nominal heat outputelmax0,002kWSingle-stage heat output, no room temperature control[no].
With minimum heat outputelminN/AkWTwo or more manual stages, no room temperature control[no].
In standby modeeISBN/AkWwith mechanical room temperature control via thermostat[no].
with electronic room temperature control[yes].
with electronic room temperature control and daylight saving tim[no].
with electronic room temperature control plus weekly timer[no].
Other control options (multiple choices possible)
room temperature control with presence detection[no].
Room temperature control with open window detection[no].
with remote control option[no].
with adaptive launch control[no].
with reduced working hours[no].
with black bulb sensor[no].
Constant pilot flame power requirement
Pilot flame power requirement (if appropriate)Ppilot0kW
Contact detailsGrupa Topex Sp. z o.o. Sp.k. UI. Pograniczna 2/4, 02-285 Warsaw
(*) NOx = Oxides of nitrogen
Seasonal energy efficiency of space heating ηS
PositionSymbolValueUnit
Seasonal energy efficiency of space heating in active modeηS,on100%
Correction coefficient (F1)/0%
Correction coefficient (F2)/7%
Correction coefficient (F3)/0%
Correction coefficient (F4)/0%
Correction coefficient (F5)/0%
Biomass label factorBLF1/
Seasonal energy efficiency of space heating ηSηS97%
Energy efficiency classesA