| Product Type | Ventilation Fan with Heater and Light |
| Brand | Broan |
| Model | 765H110LB |
| Power Supply | 120 VAC, 20 Amp dedicated circuit |
| Wiring | 12 AWG, 90°C rated supply cable |
| Bulb Type | E26 base, 100-Watt max (bulb not included) |
| Duct Size | 4-inch round ductwork |
| Mounting | Flat ceiling only, at least 6 inches from any wall |
| Function Control | 3-function control (heater, fan, light separate) |
| Heater Direction | Adjustable heater grille (rotate with screwdriver) |
| Lubrication | Permanently lubricated, no oiling required |
| Cleaning | Monthly vacuum with soft brush; do not immerse electrical parts |
| Safety | Grounding required; keep combustibles 3 ft away; do not use with dimmer |
| Warranty | Visit NuTone.com or call 888-336-6151 |
Frequently Asked Questions - 765H110LB BROAN
User questions about 765H110LB BROAN
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Home Fan in PDF format for free! Find your manual 765H110LB - BROAN and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. 765H110LB by BROAN.
USER MANUAL 765H110LB BROAN
VENTILATION FAN WITH HEATER & LIGHT
For Warranty Statement, Service Parts, Technical Support, or to Register your product, please visit our website or call: NuTone.com 888-336-6151.

natural_image
Technical line drawing of a mechanical component with no visible text or symbolsPage 1
READ AND SAVE THESE INSTRUCTIONS
IMPORTANT INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE INSTALLING OR USING THIS HEATER.
To reduce the risk of fire, electric shock, or injury to persons, observe the following:
-
Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
-
Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
-
Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
-
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
-
This heater is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes, etc. and curtains at least 3 feet (0.9 m) from the front of the heater.
-
Extreme caution is necessary when any heater is used by or near children or invalids and whenever the heater is left operating and unattended.
-
Do not operate any heater after it malfunctions. Disconnect power at service panel and have heater inspected by a reputable electrician before reusing.
-
Do not use outdoors.
-
To disconnect heater, turn controls to off, and turn off power to heater circuit at main disconnect panel (or operate internal disconnect switch, if provided).
-
Do not insert or allow foreign objects to enter any ventilation or exhaust opening, as this may cause an electric shock or fire, or damage the heater.
-
To prevent a possible fire, do not block air intakes or exhaust in any manner.
-
A heater has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint, or flammable vapors or liquids are used or stored.
-
Use this heater only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons.
-
This product must be grounded.
-
Do not install heater in a tub or shower enclosure.
-
THIS PRODUCT MUST BE MOUNTED IN A FLAT CEILING ONLY. Installations in ceilings 9-feet high or less will provide maximum comfort. DO NOT MOUNT THIS PRODUCT IN A WALL.
-
Install heater in ceiling only - at least 6 inches from any wall.
-
Do not connect heater to dimmer switch or speed control.
-
Provide a separate 20 AMP circuit. Use 12 GA. power cable of type which meets code. Use supply wiring rated for at least 90°C.
-
For greatest efficiency, install heater so heat is directed toward tub or shower area. Avoid directing toward walls or windows.
SAVE THESE INSTRUCTIONS
TYPICAL INSTALLATION

Housing mounted to joists, trusses, or I-joists. Up to 24-inches on-center.
PLAN THE INSTALLATION

The unit will operate most quietly and efficiently when located where the shortest possible duct run and minimum number of elbows will be needed.
Use a roof cap or wall cap that has a built-in damper to reduce backdrafts.
Plan to supply the unit with proper line voltage and appropriate power cable.
INSTALLATION
WARNING: To reduce the risk of fire, do not store or use gasoline or other flammable vapors and liquids in the vicinity of the heater.
CAUTION: High temperature, risk of fire, keep electrical cords, drapery, furnishings, and other combustibles at least 3 feet (0.9 m) from the front of the heater and away from the side and rear.

1. Insert hanger bars.
Four (4) sliding hanger bars are provided to allow for accurate positioning of housing anywhere between framing. They can be used on all types of framing (I-joist, standard joist, and truss construction) and span up to 24".
Slide hanger bars into channels on housing. Make sure hanger bar tabs face "up" as shown.

2. Mount housing.
Extend hanger bars to the width of the framing. Hold fan in place with the hanger bar tabs wrapping around the bottom edge of the framing.
Nail fan to framing or fasten with screws (not provided) through holes near nails.
* To ensure a noise-free mount: Secure hanger bars together with screws or use a pliers to crimp mounting channels tightly around hanger bars.
3. Attach damper / duct connector to housing.
Snap damper / duct connector onto housing. Make sure connector is flush with top of housing and damper flap falls closed.

natural_image
Hand holding a cylindrical object inside a wooden cabinet or enclosure, with no visible text or symbols.4. Install 4-inch round ductwork.
Connect 4-inch round ductwork to damper / duct connector. Run ductwork to a roof cap or wall cap. Tape all ductwork connections to make them secure and air tight.

natural_image
Technical line drawing of a mechanical assembly with no visible text or symbolsCONNECT WIRING
Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.


flowchart
graph TD
subgraph SWITCH_BOX
direction TB
A["LINE IN"] --> B["WHT"]
B --> C["GRID"]
C --> D["GRID"]
D --> E["BRK"]
E --> F["BLK"]
F --> G["BRK"]
G --> H["BRK"]
H --> I["BRK"]
end
subgraph UNIT
direction TB
J["RED"] --> K["WHT"]
L["RED"] --> M["WHT"]
N["RED"] --> O["WHT"]
P["RED"] --> Q["WHT"]
R["RED"] --> S["WHT"]
T["RED"] --> U["WHT"]
V["RED"] --> W["WHT"]
X["RED"] --> Y["WHT"]
end
style SWITCH_BOX fill:#f9f,stroke:#333
style UNIT fill:#ccf,stroke:#333
5. Connect electrical wiring.
Run 120 VAC house wiring to installation location. Use proper UL approved connectors to secure house wiring to wiring plate. Connect wires as shown in wiring diagram(s).
INSTALL GRILLE & BULB
6. Finish ceiling.
Install ceiling material. Cut out ceiling material closely around housing.
7. Remove light lens from grille.
Insert a small flat-bladed screwdriver into the slot at one end of the light lens. Carefully pry the lens out.

8. Plug-in light.
Hold grille assembly up near housing. Connect light plug from grille assembly to receptacle inside of housing.

natural_image
Line drawing of a hand using a tool to adjust or install electronic components on a device (no text or symbols visible)9. Attach grille.
Place grille/ reflector combination over protruding screw and fasten in place using acorn nut provided. HAND TIGHTEN acorn nut 1/4 turn after it is snug.

10. Install bulb.
The unit accepts a 100-Watt (maximum) E26 base bulb. (Bulb not included.)

natural_image
Line drawing of a hand holding a car interior panel (no text or symbols)11. Attach light lens.
Hook the tabs on one end of the lens into the slot in the grille. Lift other end of lens up and snap into place.

natural_image
Line drawing of a hand holding a small object, possibly a device or tool, with no visible text or symbols.12. Rotate heater grille.
Use a flat-bladed screwdriver to rotate the round heater grille to provide heat in the desired direction.

natural_image
Illustration of a hand using a tool to apply a circular component to a car hood (no text or symbols visible)OPERATION
Before using heater, make sure heater has been properly installed according to installation steps beginning with the "TYPICAL INSTALLATION" section on page 1.
Use a 3-Function Control to operate the heater, fan, and light separately. See "Connect Wiring" for details.
MAINTENANCE
The following maintenance and cleaning tasks can be performed by the user. All other servicing must be performed by an authorized technician. If you have any questions, please consult with our customer service department at: 800-558-1711.
TO REPLACE BULB
Remove lens by gently depressing sides and pull down. Use a maximum 100-Watt E26 base bulb.
LUBRICATION
The heater is permanently lubricated and never needs oiling or disassembly.
CLEANING
Clean heater once a month as follows:
- Turn off power at service panel.
- Make sure heating element is cool.
- Use a soft brush attachment to gently vacuum grille openings or wipe grille clean with a soft cloth.
- Restore power.
CAUTION: METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER.
This page intentionally left blank.
VENTILADOR CON CALEFACTOR Y LUZ
natural_image
Technical line drawing of a mechanical component with no visible text or symbolsPágina 7