XMS-2624P - Network switch Luxul - Free user manual and instructions
Find the device manual for free XMS-2624P Luxul in PDF.
| Product Type | 26-Port/24 PoE+ Gigabit Managed Switch |
| Ports | 26 x Gigabit Ethernet RJ-45 (ports 1-24 PoE+, 25-26 non-PoE) + 2 x Gigabit SFP+ |
| PoE Standards | PoE+ (802.3at/af) |
| PoE Budget | 370W total, up to 25.5W per port |
| Management | Web-based GUI (default IP: 192.168.0.4) |
| Default Username/Password | admin / admin |
| Power Supply | Internal, 100-240VAC, 50/60Hz |
| Console Port | RJ-45 console port |
| Mounting | Rack-mountable (19-inch) with included ears; desktop with included rubber feet |
| LED Indicators | System, Link/Act per port (green=1000M, yellow=10/100M, flashing=activity), PoE per port (green=power on, yellow=fault) |
| Reset Button | Short press (3s) reboots; long press (8s) restores factory defaults |
| Cabling Recommendation | CAT5e UTP or better; CAT6 recommended for 1000Mbps |
| Included Accessories | Rack mount kit, rubber feet, power cord, console cable |
| Dimensions | Standard 1U rack-mount (exact dimensions not specified) |
| Weight | Not specified |
Frequently Asked Questions - XMS-2624P Luxul
User questions about XMS-2624P Luxul
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Network switch in PDF format for free! Find your manual XMS-2624P - Luxul and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. XMS-2624P by Luxul.
USER MANUAL XMS-2624P Luxul
natural_image
Front view of a black LUXUL network switch device with multiple Ethernet ports (no visible text or labels beyond branding)26-Port/24 PoE+ Gigabit Managed Switch
XMS-2624P
Includes:
26-Port PoE+ Switch
Rack Mount Kit
Rubber Feet
Power Cord
Console Cable
INSTALLATION AND SETUP
1 Physical Installation
The XMS-2624P can easily be installed in a standard 19" rack. Two mounting ears are included for installing and stabilizing the switch. When attaching the mounting ears and installing the switch in a rack, please refer to the following illustration:

natural_image
3D diagram of a device with labeled components and arrows indicating flow or movement (no readable text or symbols)Rack-Mounting the XMS-2624P
Using the included screws to attach the mounting ears to each side of the switch.
Mount the switch in the rack with the LEDs facing outwards. Be sure the switch is level and properly secured in the rack.
Desktop Setup
For use as a desktop device, position and apply the included rubber feet to the bottom of the XMS-2624P.

Connecting Ethernet and Power
Ethernet and Power Connections
Use any one of the 26 Ethernet ports to connect the XMS-2624P to any Ethernet-enabled device, including servers, routers or other switches. No crossover cable is necessary.
The XMS-2624P supports 10/100/1000 Mbps Ethernet; 10/100 Mbps half/full-duplex mode and 1000 Mbps full-duplex mode. Ports 1-24 are PoE+ and are enabled by default. Ports 25 and 26 are Gigabit Ethernet only (non PoE).
Use the included power cable to connect the XMS-2624P to a surge-protected outlet. The AC input socket is on the rear panel. The built-in power supply supports 100\~240VAC at 50/60Hz.
Network Cabling
Luxul recommends at least Cat-5e unshielded twisted pair (CAT5e UTP) cabling. To ensure best performance and stable data transmission at 1000 Mbps, use Category-6 unshielded twisted pair (CAT6 UTP).

CAUTION: Multiple Uplink channels can create loops, resulting in network failure. Ensure only one Uplink channel exists between switches or between the XMS-2624P and a router.

NOTE: When powering up, the port LEDs may take a moment to initialize. This is normal as the XMS-2624P initialization and startup sequence completes.

NOTE: The XMS-2624P has an internal 370W power supply. Do not exceed 25.5W each or 370W combined consumption of all external PoE devices.

Preparing for Access
IP Addressing
If the XMS-2624P is connected to a network with a 192.168.0.X address scheme, and your computer shares a similar address on the same network, you can skip to the next step, Access and Setup

Note: If another device on your network shares the 192.168.0.4 address, you'll need to temporarily reassign or remove that device while you configure the XMS-2624P.
If your network uses an address scheme other than 192.168.0.X, you'll need to set a temporary static IP address on the computer you're using for configuration. To do so, set the IP address of your computer to an address in the 192.168.0.X range, then set the Gateway/Router address to 192.168.0.4 (the default IP address of the XMS-2624P).
Once you're finished configuring the switch, you can return your computer's IP configuration to normal, typically "Obtain Automatically/DHCP."

Note: Visit http://luxul.com/ip-addressing to learn more about changing your computer's IP address and getting connected.

Access and Setup
Getting Connected
Use an Ethernet cable to connect your computer to the XMS-2624P, then power on the switch.
Logging In
To access the XMS-2624P web configuration, open your web browser and enter the switch's default 192.168.0.4 IP address in the address field. Log in to the switch using the default user name and password:
Default IP: 192.168.0.4
Username: admin
Password: admin
Select the menu items on the left to view and/or modify the configuration.
Refer to the Quick Setup Guide at Luxul.com for more detailed information on setup, IP configuration and routing, PoE, VLANs, Spanning Tree, and Stacking.

Hardware Operation
Front Panel
The front panel of the XMS-2624P includes 26 Gigabit Ethernet RJ-45 ports, two Gigabit SFP+ ports, status-, link- and PoE LEDs, a Mode/Reset button and an RJ-45 Console port.

XMS-2624P Front Panel View
Rear Panel
The rear panel of the XMS-2624P features a standard AC power input along with a power switch.
LED Indicators
The LED indicators on the XMS-2624P include System, Link/Act and PoE LEDs, and an LED for each port. These LED indicators show the operating status of the XMS-2624P and each port connection.
Mode/Reset Button to Change LED Functionality
Tapping the Mode/Reset button briefly switches the port indicator between displaying port link speed and PoE status.
The following chart shows the LED indicators of the XMS-2624P along with an explanation of the indicator's properties:
| Indicator Name | Description | |
| System | Green Flashing Indicates normal operation. | |
| Green On Indicates a malfunction. Contact support. | ||
| Red On Indicates power-on system initialization. | ||
| Off | Indicates startup/initialization process or that power is not on. | |
| Port Link/Act Status 1-26 | Green | 1000Mbps device connected to the port. |
| Yellow | 10/100Mbps device connected to the port. | |
| Flashing | Port receiving or transmitting data. | |
| Off | Nothing connected to the port. | |
| Port PoE Status 1-24 | Green | Switch is providing PoE power to a device. |
| Yellow | PoE is off due to a fault or because the connected device is exceeding power limit. | |
| Off | Port disconnected or link failed. | |
Note: At startup, the port LEDs will flash briefly during a self-test.
Mode/Reset Button to Reset/Restore
The Reset button (located at the lower-left corner of the front panel) is used to reset (reboot) the switch, or to restore the switch to factory default settings.
To Reboot/Reset the Switch: With the XMS-2624P powered on, press the Reset button for approximately three seconds until the Link/Act and PoE LEDs both light, then release the button.

CAUTION: Do not hold the button for more than four seconds. Doing so could erase all settings and restore factory defaults.
To Restore Default Settings: With the XMS-2624P powered on, press and hold the Reset button approximately eight seconds, until both the Link/Act and PoE LEDs turn off, then release the Reset button and the switch automatically restores factory default settings and reboots. Once the System LED starts flashing again, the XMS-2624P is running with factory defaults.

CAUTION: Please note that restoring Default Settings will remove any/all custom configuration.
Sales
801-822-5450
sales@luxul.com
Technical Support
801-822-5450
support@luxul.com
Copyright and Trademark Notices
No part of this document may be modified or adapted in any way, for any purposes without permission in writing from Luxul. The material in this document is subject to change without notice. Luxul reserves the right to make changes to any product to improve reliability, function, or design. No license is granted, either expressly or by implication or otherwise under any Luxul intellectual property rights. An implied license only exists for equipment, circuits and subsystems contained in this or any Luxul product.
© Copyright 2017 Luxul. All rights reserved. The name Luxul, the Luxul logo, the Luxul logo mark and Simply Connected are all trademarks and or registered trademarks of Luxul Wireless, Inc. All other trademarks and registered trademarks are property of their respective holders.
LUX-QIG-XMS-2624P-v8 02131809
A brand of legrand®