| Product Type | Programmable DC Power Supply |
| Brand | Aim TTi (Thurlby Thandar Instruments) |
| Model | CPX400SA |
| Voltage Range | 0 to 60 V |
| Current Range | 0 to 20 A (up to 420 W) |
| Power Output | Up to 420 W (PowerFlex envelope) |
| Operating Modes | Constant Voltage (CV) or Constant Current (CC) with automatic crossover |
| Selectable Ranges | 60V/20A, 60V/7A, 20V/20A, and Custom Limits |
| Meter Resolution | 10 mV, 10 mA |
| Meter Accuracy | Voltage: 0.1% ± 2 digits; Current: 0.3% ± 2 digits |
| Output Protection | Over-Voltage Protection (OVP), Over-Current Protection (OCP), Over-Temperature Protection, Reverse diode clamp (up to 3A) |
| OVP Range | 1 V to 66 V (set via screwdriver or remote interface on SP models) |
| OCP (CPX400SA) | Fixed at 22 A (firmware-based on SP models) |
| Analog Remote Control | Isolated inputs (0-5V or 0-10V) for voltage and current setting; control outputs for monitoring |
| Remote Off | Rear panel switch closure turns output off |
| Output Terminals | Front: 4mm safety binding posts; Rear: Barrier strip (CPX400SA/SP only) |
| Output Sensing | Selectable local or remote (spring-loaded terminals front, barrier strip rear) |
| AC Input | 110-240 VAC ±10%, 50/60 Hz, 600 VA max |
| Dimensions (W x H x D) | 107 mm x 130 mm x 400 mm (1/4 rack width, 3U height) |
| Weight | 4.25 kg |
| Operating Temperature | 5°C to 40°C, 20% to 80% RH |
| Storage Temperature | -40°C to 70°C |
| Safety & EMC Compliance | EN61010-1, EN61326-1 |
| Included Accessories | Power cord, manual (PDF available online) |
| Settings Lock | Single button press locks voltage and current settings |
Frequently Asked Questions - CPX400SA Aim TTi
User questions about CPX400SA Aim TTi
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Power Supply in PDF format for free! Find your manual CPX400SA - Aim TTi and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. CPX400SA by Aim TTi.
USER MANUAL CPX400SA Aim TTi
AIM & THURLBY THANDAR INSTRUMENTS
CPX400S & SA & SP
PowerFlex DC Power Supply
General specifications apply for the temperature range 5^ C to 40^ C. Accuracy specifications apply for the temperature range 18^ C to 28^ C after 1 hour warm-up with no load and calibration at 23^ C.
Typical specifications are determined by design and are not guaranteed.
OUTPUT SPECIFICATION
| Voltage Range: | 0V to 60V | |||||
| Current Range: | 0A to 20A | |||||
| Note: In manual operation, actual maxima for voltage and current are typically 1% greater that the figures given above. | ||||||
| Power Range: | Up to 420W | |||||
| Output Voltage Setting: | By coarse and fine controls. | |||||
| Output Current Setting: | By single logarithmic control. | |||||
| Operating Mode: | By single logarithmic control. | |||||
| Constant voltage (CV) or constant current (CC) with automatic cross-over, provided that the power demanded stays with the power envelope, see graph. Outside of this envelope the output becomes unregulated. | ||||||
| Operating Ranges: | Four selectable ranges: 60V/20A, 60V/7A, 20V/20A and Custom Limits.Any V/I setting of the 60V/7A or 20V/20A ranges always falls within the appropriate part of the Power Envelope.The 60V/20A range permits any setting up to 60V and 20A but the output will become unregulated if operated outside of the Power Envelope, see above.The voltage and current limits of the Custom Limits range can be set to any V_max between 0.1V & 60V and I_max between 0.01A and 20A. This facility is most useful in limiting operation to a particular part of the Power Envelope. | |||||
| Settings Lock:(S-Lock) | Voltage and current settings can be locked by a single button press.Lock accuracy is equal to meter accuracy (see Meter Specification) | |||||
| Output Switch: | Electronic. Preset voltage and current displayed when off. | |||||
| Output Terminals: | Front panel: Universal 4mm safety binding posts on 19mm (0·75") pitch.Rear Panel: Barrier strip connections (CPX400SA/SP only) | |||||
| Output Sensing: | Switchable between local and remote. Remote connection by spring-loaded push terminals on front panel and barrier strip on rear panel (CPX400SA /SP only). | |||||
| Output Protection: | Forward protection by Over-Voltage Protection (OVP) and Over-Current Protection (OCP) trips.Reverse protection by diode clamp for reverse currents up to 3A. | |||||
| OVP Range: | 1V to 66V set by front panel screwdriver adjustment or via the remote interfaces (CPX400SP only). Setting resolution: 100mV. Response time: Typically 1ms. Maximum voltage that should be applied across the terminals is 70V. | |||||
| OCP Range: | Measure-and-compare over-current protection is implemented in firmware and can only be set via the remote interface (CPX400SP only). Setting resolution: 10mA. Response time: typically 500ms.For CPX400S/SA, OCP is fixed at 22A. | |||||
| Over-temperature | The output will be tripped off if a fault causes the internal temperature to rise | |||||
| Protection:Line Regulation: | excessively.Change in output for a 10% line change:Constant voltage: <0.01% of maximum outputConstant current: <0.01% of maximum output | |||||
| Load Regulation: | Change in output for any load change within PowerFlex envelope, remote sense connected:Constant voltage: <0.01% of maximum outputConstant current: <0.05% of maximum output | |||||
| Ripple & Noise(20MHz bandwidth): | 5mVrms max; typically <3mVrms, <15mV pk-pk, at maximum load, CV mode. | |||||
| Transient LoadResponse: | <250us to within 50mV of set level for a 5% to 95% load change. | |||||
| Voltage ProgrammingSpeed (CPX400SP only): | Maximum time required for output to settle within 1% of its total excursion(for resistive load). Excludes command processing time. | |||||
| Range and Setting | 90% Load | No Load | 90% Load | No Load | ||
| 60V 7A | Up | 8ms | 8ms | Down | 80ms | 1.5s |
| 20V 20A | Up | 8ms | 8ms | Down | 10ms | 1.2s |
| Temperature Coefficient: | Typically <100ppm/°C | |||||
| Status Indication: | Output ON lamp.Constant voltage mode lamp.Constant current mode lamp.Unregulated (power limit) lampRemote lamp (CPX400SP only)LAN lamp (CPX400SP only)Trip message on display. | |||||
METER SPECIFICATIONS
| Meter Types: | Dual 4 digit meters with 10mm (0.39") LEDs. Reading rate 4Hz. |
| Meter Resolutions: | 10mV, 10mA |
| Meter Accuracies: | Voltage 0.1% of reading ± 2 digitsCurrent 0.3% of reading ± 2 digits |
ANALOGUE REMOTE CONTROL (CPX400SA only)
Isolated inputs and non-isolated outputs to set voltage and current limit.
| Isolated control input scaling: | Rear panel control inputs (CV and CC) permit external 0V to 5V or 0 to10V signals (with respect to the common Return) to set 0 to 100% of rated output voltage and current. Inputs are protected against excess input voltages up to 60V. Isolation rating with respect to the output is 300V max. |
| Control input accuracy: | Voltage: 0.3% ±20mV. Input impedance 10kΩ.Current: 0.5% ±50mA. Input impedance 10kΩ. |
| Control output scaling: | Set values of 0 to 100% of rated output voltage and current generate 0 to 5V signals at the rear panel V_out and I_out outputs. Outputs are short-circuit protected. These signals are referenced to the output control circuit and will therefore be within ~1V of the positive output potential. |
| Control output accuracy: | Voltage: 0.3% ±20mVCurrent: 0.5% ±50mA.Output impedance: 125Ω. |
| Remote Off: | Rear panel connections allow a switch closure to turn output off. Remote Off is referenced to the output control circuit and will therefore be within ~1V of the positive output potential. |
DIGITAL INTERFACES (CPX400SP only)
Full digital remote control facilities are available through the RS232, USB, LAN and GPIB interfaces.
| Voltage Setting: | 16-bit, Resolution 10mV, Accuracy ± (0·05% +10mV) |
| Current Setting: | 16-bit, Resolution 1mA, Accuracy ± (0·3% + 0·005A) |
| RS232: | Standard 9-pin D-connector. Baud rate 9600. |
| GPIB: | Conforming with IEEE488.1 and IEEE488.2 |
| USB: | Standard USB 2.0 hardware connection. Operates as a virtual COM port. |
| LAN: | Ethernet 100/10base-T hardware connection. 1.4 LXI Core 2011 |
| Remote Command Processing Time: | Typically <25ms between receiving the command terminator for a step voltage change at the instrument and the output voltage beginning to change. |
GENERAL
| AC Input: | 110V – 240V AC ± 10%, 50/60Hz.Installation Category II. |
| Power Consumption: | 600VA max. |
| Operating Range: | +5°C to +40°C, 20% to 80% RH. |
| Storage Range: | -40°C to +70°C. |
| Environmental: | Indoor use at altitudes up to 2000m, Pollution Degree 2. |
| Safety & EMC: | Complies with EN61010-1 & EN61326-1.For details, request the EU Declaration of Conformity for this instrument via http://www.aimtti.com/support (serial no. needed). |
| Size: | 107mm x 130mm x 400mm (WxHxD) 1⁄4-rack width x 3U height (optional rack mounting kit available). |
| Weight: 4.25kg |
Sicherheit

Diagram shows remote sense connections, set the sense switch to remote. If remote sensing is not required, do not use the sense wires and set the sense switch to local.
If independent current limits are required set CC to Local and set the limits from the front panel of each unit.

Warning! In series operation take care not to exceed the maximum rated operating voltage (300V) of any terminal with respect to earth ground ( 1 )
Remote Off
A switch closure or logic low between the rear panel Rem Off and COM inputs will remotely turn off the output if it was previously on; the front panel OUTPUT lamp will also go off. Opening the switch between Rem Off and COM will turn the output on again.

Warning! COM is referenced to the output control circuit and will be within \~1V of the positive output potential.
THURLBY THANDAR, CPX400SP, 279730, 1.00 - 1.00
| bit 7 = | X | Unbeachtet lassen |
| bit 6 = | 1 | Aktivierung der Parallelabfrage |
| bit 5 = | 1 | |
| bit 4 = | 0 | |
| bit 3 = | Sense | Wert des Antwortbits: 0 = low, 1 = high |
| bit 2 = | ? | Bitposition der Antwort |
| bit 1 = | ? | |
| bit 0 = | ? |
Status Byte Register = 0
Service Request Enable Register = 0
Standard Event Status Enable Register = 0
Execution Error Register = 0
Query Error Register = 0
Parallel Poll Enable Register = 0
†□
- Teldees it diesem
Thurlby Thandar Instruments Ltd.
Glebe Road • Huntingdon • Cambridgeshire • PE29 7DR • England (United Kingdom)
Telephone: +44 (0)1480 412451 • Fax: +44 (0)1480 450409
International web site: www.aimtti.com • UK web site: www.aimtti.co.uk • USA web site: www.aimtti.us
Email: info@aimtti.com