QPX600DP - Power Supply Aim TTi - Free user manual and instructions
Find the device manual for free QPX600DP Aim TTi in PDF.
| Product Type | PowerFlex+ Dual DC Power Supply |
| Output Channels | 2 independent outputs |
| Voltage Range (per output) | 0V to 60V or 0V to 80V (two ranges) |
| Current Range (per output) | 0.01A to 50A |
| Power Range (per output) | Up to 600W (within PowerFlex envelope) |
| Voltage Setting Resolution | 1mV (60V range), 2mV (80V range) |
| Voltage Setting Accuracy | 0.1% ± 2mV (60V range), ±4mV (80V range) |
| Current Setting Resolution | 10mA |
| Current Setting Accuracy | 0.3% ± 20mA |
| Ripple & Noise (20MHz BW) | <3mVrms, <20mV pk-pk at max load, CV mode |
| Over-Voltage Protection (OVP) | Range 2V to 90V, resolution 0.1V, accuracy 0.2% ± 0.2V |
| Over-Current Protection (OCP) | Range 2A to 55A, resolution 0.1A, accuracy 0.5% ± 0.2A |
| Display Type | 5-digit (V), 4-digit (A) backlit LCD per output |
| Remote Interfaces (QPX600DP only) | RS232, USB, LAN, GPIB |
| AC Input | 115V – 240V AC ±10%, 50/60Hz |
| Power Consumption | 1600VA max |
| Operating Temperature Range | +5°C to +40°C |
| Storage Temperature Range | -40°C to +70°C |
| Dimensions (H x W x D) | 130mm x 356mm x 413mm (3U) |
| Weight | 9.2kg |
| Safety & EMC Compliance | EN61010-1 & EN61326-1 |
Frequently Asked Questions - QPX600DP Aim TTi
User questions about QPX600DP Aim TTi
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Power Supply in PDF format for free! Find your manual QPX600DP - Aim TTi and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. QPX600DP by Aim TTi.
USER MANUAL QPX600DP Aim TTi
AIM & THURLBY THANDAR INSTRUMENTS
QPX600D & DP
PowerFlex+ Dual DC Power Supplies
General specifications apply for the temperature range 5° C to 40° C. Accuracy specifications apply for the temperature range 18° C to 28° C after 1 hour warm-up with no load and calibration at 23° C. Typical specifications are determined by design and are not guaranteed.
OUTPUT SPECIFICATIONS (Each Output)
Voltage Range: Two ranges: 0V to 60V or 0V to 80V
Current Range: 0.01A to 50A
Power Range: Up to 600W
Voltage Setting: Resolution: 1mV (60V Range),
2mV (80V Range)
Accuracy: 0.1% of setting ± 2mV,
(± 4mV on 80V range)
Current Setting: Resolution 10mA
Accuracy: 0.3% of setting ± 20mA
Operating Mode: Constant voltage or constant current
with automatic cross-over provided that the power demanded stays within the power envelope, see graph.
Outside of this envelope the output becomes unregulated. CV, CC or UNREG mode indication in display.

Output Switch:
Independent electronic switching, with ON indication. In addition, BOTH ON and BOTH OFF keys permit both outputs to be switched on/off synchronously ( ±10µs ). Preset voltage and current displayed when off.
Output Terminals:
Rear panel safety terminals accepting 6mm wire diameter, 6mm plugs or 8mm spades at 50 Amps max, or 4mm plugs at 30 Amps max.
Sensing:
Switchable between local and remote. Screwless remote sense terminals on rear panel. Sense miswiring trip and indication.
Ripple & Noise
(20MHz bandwidth):
Typically <3mVrms, <20mV pk-pk at maximum load, CV mode
Load Regulation: Change
in output for any load change within PowerFlex envelope, using remote sense:
Constant voltage: <0.01% ± 5mV
Line Regulation:
Change in output for a 10% line change:
Constant voltage: <0.01% ± 5mV
Transient Response:
<2ms to within 100mV of set level for a 5% to 95% load change.
Output Protection:
Output will withstand an applied forward voltage of up to 90V.
Reverse protection by diode clamp for reverse currents up to 3A.
Over-voltage Protection (OVP):
Range 2V to 90V. Resolution 0.1V; accuracy: 0.2% ± 0.2V.
Response time typically 100µs .
Over-current Protection (OCP):
Range 2A to 55A. Resolution 0.1A; accuracy: 0.5% ± 0.2A.
Response time typically 100ms.
Over-temperature Protection:
The output will be tripped off if a fault causes the internal temperature to rise excessively.
Temperature Coefficient:
Typically <100ppm/°C
METER SPECIFICATIONS (Each Output)
| Display Type: | 5-digit (Volts), 4-digit (Amps), black-on-white backlit LCD. |
| Voltage(CC Mode and Unreg): | Resolution 1mVAccuracy: 0.1% of reading ± 2 digits |
| Current(CV Mode and Unreg): | Resolution 10mAAccuracy: 0.3% of reading ± 2 digits |
| V x A: Resolution 0·1W | Accuracy: 0·5% ± 0·1W |
| V/A: | Meter shows calculated nominal V/A value, together with uncertainty range; 5 digit resolution. |
LOGIC CONTROL INPUT and OUTPUT (Each Output)
LOGIC IN is a rear-panel opto-isolated input with an 820Ω resistor in series that is activated at an input voltage greater than approximately 3.3V. The maximum voltage that can be applied without damaging the unit is 20V and the input should not be taken negative by more than 3V. User can set LOGIC IN (via the keyboard) to enable the output, disable the output, or be ignored when it is activated.
LOGIC OUT is an isolated rear-panel open-collector output that will sink up to 2mA when activated ('switch closure'); the maximum voltage that can be applied to LOGIC OUT is 30VDC. User can set LOGIC OUT to be 'closed' or 'open' for output enabled or disabled, current limit (CC mode), power limit (UNREG mode), or for any fault trip.
ANALOG REMOTE CONTROL and MONITORING (Each Output)
Quasi-analogue inputs and outputs to set voltage and current limit and to monitor actual output voltage and current. The control inputs are read four times per second by the A-D converter and the output is set according to the selected input scaling; similarly the monitor outputs are updated four times per second with values representing the actual output voltage and current. These signals each have a range of 0 to 10V or 0 to 5V with respect to the shared COM return signal; the set range applies to all inputs and outputs.
Analogue Control Voltage Range: Keyboard selectable to be 0 to 10Vdc or 0 to 5Vdc for range maximum output. Absolute maximum input 20Vdc.
Analogue Control Accuracy: Voltage: 0.3% ± 4mV; Current: 0.5% ± 40mA.
Analogue Control Common Mode Range: ± 2.5Vdc max to negative output.
Analogue Control Input Impedance: Nominally 40kΩ.
Analogue Monitor Voltage Range: Same as set for Analogue Control Voltage Range.
Analogue Monitor Accuracy: Voltage: 0.3% ± 4mV; Current: 0.5% ± 40mA.
Analogue Monitor Output: Connect to isolated measuring system with >10kΩ input impedance. Will withstand a short-circuit.
LINK MODES
In addition to independent output operation, the instrument is capable of operating in a number of different voltage tracking modes which can be activated from the LINK MENU. These modes include Output 2 voltage (V2) tracking Output 1 voltage (V1) by any ratio in the range 5% to 2000%, V2 and I2 set to track V1 and I1 (1:1) with total V1 + V2 displayed (useful when Output 1 and Output 2 are series connected), V2 and I2 set to track V1 and I1 (1:1) with total I1 + I2 displayed (useful when Output 1 and Output 2 are parallel connected).
KEYBOARD & ROTARY CONTROL
All functions, including the selection and set-up of the remote control interfaces, can be set from the keyboard. The rotary Jog control can be used to adjust output voltage and current settings in a quasi-analogue mode. The output to be controlled is first selected with the appropriate Control key.
DISPLAY FEATURES
The displays (one for each output) are graphic LCDs, backlit by white LEDs; contrast is software-controlled and can be adjusted from the keyboard.
The default status displays show the VOLTS (5 digits) and AMPS (4 digits) in 12mm high characters, plus output range and status. At other times, for example during store or recall of instrument set-ups, the displays show up to 7 lines of information, instructions, or prompts.
INTERFACES (QPX600DP only)
Full digital remote control facilities are available through the RS232, LAN, USB and GPIB interfaces. Setting and readback resolutions are the same as for the Output and Meter specifications respectively.
RS232: Standard 9-pin D-connector. Baud rate 9600.
USB: Standard USB 2.0 hardware connection.
LAN: Ethernet 100/10base-T hardware connection. 1.4 LXI Core 2011 compliant.
GPIB: Conforms with IEEE488.1 and IEEE488.2.
Remote Command Processing Time: Typically <100ms between receiving the command terminator for a step voltage change at the instrument and the output voltage beginning to change.
GENERAL
AC Input: 115V – 240V AC ± 10%, 50/60Hz. Installation Category II.
Power Consumption: 1600VA max.
Operating Range: +5°C to +40°C, 20% to 80% RH.
Storage Range: -40°C to +70°C .
Environmental: Indoor use at altitudes up to 2000m, Pollution Degree 2.
Store/Recall: Up to 10 set-ups can be saved and recalled via the keyboard or remote interfaces.
Safety & EMC: Complies with EN61010-1 & EN61326-1.
For details, request the EU Declaration of Conformity for this instrument via http://www.aimtti.com/support (serial no. needed).
Size: 130mm H (3U) x 356mm W x 413mm D
Weight: 9.2kg
Options: 19-inch rack kit.
Sicherheit
| bit 7 = | X | Unbeachtet lassen |
| bit 6 = | 1 | Aktivierung der Parallelabfrage |
| bit 5 = | 1 | |
| bit 4 = | 0 | |
| bit 3 = | Sense | Wert des Antwortbits; 0 = low, 1 = high |
| bit 2 = | ? | Bitposition der Antwort |
| bit 1 = | ? | |
| bit 0 = | ? |
Status Byte Register = 0
Service Request Enable Register † = 0
4Standard Event Status Register = 128 (nach Setzen des Bits)
Standard Event Status Enable Register † = 0
Execution Error Register = 0
Query Error Register = 0
Parallel Poll Enable Register = 0
Thurlby Thandar Instruments Ltd.
Glebe Road • Huntingdon • Cambridgeshire • PE29 7DR • England (United Kingdom)
Telephone: +44 (0)1480 412451 • Fax: +44 (0)1480 450409
International web site: www.aimtti.com • UK web site: www.aimtti.co.uk
Email: info@aimtti.com