IAN 53426 - Lighting Livarno Lux - Free user manual and instructions
Find the device manual for free IAN 53426 Livarno Lux in PDF.
| Product Type | Halogen Ceiling Light (6-light spotlight) |
| Model Numbers | 3978/062L and 3958/062L |
| Brand | Livarno Lux |
| IAN | 53426 |
| Power Supply | 230-240 V~, 50 Hz |
| Bulb Type | G9 (230-240V, 40W max each) |
| Number of Bulbs | 6 |
| Total Max Power | 240 W (6 x 40W) |
| Protection Class | I |
| Maximum Length | Approx. 1.19 m (adjustable via joints) |
| Adjustable Joints | 2 joints for length/alignment adjustment |
| Adjustable Spotlights | Each spotlight rotates up to 270° |
| Suitable For | Indoor dry, enclosed spaces; normally inflammable surfaces |
| Mounting | Ceiling mounted (hardware included) |
| Included Accessories | 6 bulbs, 6 glass lampshades, 6 ring nuts, mounting frame, screws, wall plugs, tool, manual |
| Safety Distance | At least 0.5 m from illuminated material |
| Installation | Must be performed by a qualified electrician |
| Cleaning | Dry, lint-free cloth only; no water or solvents |
| Bulb Replacement | Replace with G9 40W max bulbs; allow lamp to cool before handling |
| Warranty | 36 months from date of purchase |
| Certifications | CE, WEEE compliant |
| Weight | Approx. 1.5 kg |
| Material | Metal and glass |
Frequently Asked Questions - IAN 53426 Livarno Lux
User questions about IAN 53426 Livarno Lux
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Lighting in PDF format for free! Find your manual IAN 53426 - Livarno Lux and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. IAN 53426 by Livarno Lux.
USER MANUAL IAN 53426 Livarno Lux
natural_image
Modern office lighting fixture with a central hub and six adjustable lights, shown in an inset view (no text or symbols)
HALOGEN CEILING LIGHT
Operation and Safety Notes

CORP DE ILUMINAT CU HALOGEN
Before reading, unfold the page containing the illustrations and familiarise yourself with all functions of the device.
HR
Prije nego što pročitate tekst, otvorite stranicu sa slikama i upoznajte se na osnovu toga sa svim funkcijama uređaja.
RO
GB / CY Operation and Safety Notes Page 5
HR Upute za posluživanje i za Vašu sigurnost Stranica 11
Included items Page 6
Description of parts....Page 6
Technical information......Page 6
Safety
Safety advice......Page 6
Preparation
Required tools and materials....Page 7
Before installation Page 7
Preparations for use
Fitting the light Page 8
Adjusting the joints....Page 8
Adjusting the spotlights....Page 8
Changing the bulbs....Page 8
Maintenance and Cleaning Page 8
Disposal Page 9
Information
Guarantee Page 9
Service Page 9
Declaration of Conformity Page 9
Halogen Ceiling Light
- Introduction

Please read carefully and completely through these operating instructions. Fold out the page with the illustrations.
These instructions form part of the product and contain important information about bringing the product into use and its handling. Always observe all the safety advice. Check that the correct mains voltage is available and that all the parts have been properly assembled before bringing into use. Should you have any questions or be uncertain as to how to operate the device, please get in touch with your dealer or service point. Please keep these instructions in a safe place and hand them on to a third party if necessary.
- Proper use
This light is suitable only for interior use, in dry and enclosed spaces. This lamp is intended for use only in a domestic environment.
The light can be fitted to all normally inflammable surfaces.
Included items
Check that all the items and accessories are present and that the lamp is in perfect condition immediately after unpacking.
1 Halogen Ceiling Light, Model 3978 / 062L or 3958/062L (6-light spotlight).
6 Bulbs G9, 40W
6 Ring nuts
6 Glass lampshades
2 Wall plugs
2 Screws
1 Tool
1 Set of instructions
• Description of parts
3978 / 062L + 3958 / 062L
1 Installation frame with slotted holes
2 Insulating screw joint
3 Screws
4 Terminal housing
5 Spotlight
6 Glass lampshade
7 Joint
8 Ring nut
9 Bulb
● Technical information
Article-No.: 3978/062L or 3958/062L
Operational voltage: 230-240V \~ 50Hz
Bulb: 230-240V, 40W, G9
Maximum nominal output: 6 x 40 W
Protection category: I
● Safety

Safety advice
The right to claim under the guarantee shall be rendered invalid in respect of damage caused by the non-observance of these operating instructions! No liability is accepted for consequent damage! No liability is accepted for damage to property or persons caused by improper handling or non-observance of the safety advice!

To avoid danger to life from electric shock
■ Ensure that a qualified electrician or a person trained to carry out electrical installations performs the electrical installation.
■ Every time before connecting the lamp the mains, check it and the mains lead for damage. Never use your light if you find it is damaged in any way.
CAUTION! A damaged mains lead presents a serious danger to life from electric shock. In the event of damage, repairs or other problems with the lamp please contact the service centre or an electrician.
Before installation, remove the fuse for this circuit or switch off at the circuit breaker (0 setting) in the fuse box.
Before assembly, ensure that the mains voltage available corresponds to the operating voltage necessary of the light (230 - 240 V\~).
■ Never let the lamp come into contact with water or other liquids.
■ Never open or insert anything into electrical fittings or equipment. Doing this sort of thing can lead to a serious danger to life from electric shock.
- Do not install the lamp on a moist and conductive surface!

To avoid danger of fire and injury
RISK OF INJURY! Check every bulb and lampshade for damage immediately upon unpacking. Do not fit the light if the bulbs and / or lampshades are faulty. If they are, contact the service point for a replacement.
RISK OF INJURY FROM BURNS! Ensure the lamp has been switched off and allowed to cool before you touch it. In this way you will avoid the danger of burns. Bulbs give off a lot of heat around the top of the lamp.
- Replace any faulty bulbs with new ones immediately. Before replacing the bulb, always remove the fuse or switch the automatic cutout off.
FIRE HAZARD! Fit the light so that it is at least 0.5 m away from the material illuminated. Fire can result
from the development of too much heat.
- Do not allow the lamp or the packaging materials to lie around unattended. Plastic film or bags, Styrofoam etc. can turn into dangerous toys for children.

Working safely
■ Only use 230-240V \~ bulbs with a G 9 base and a maximum output of 40 Watts.
■ Fit the light in such a way to ensure it is protected from damp and dirt.
■ Make careful preparations for the assembly and take sufficient time. Clearly lay out all components and any additional tools or materials that might be required so that they are readily to hand.
- Remain alert at all times and always watch what you are doing. Always proceed with caution and do not assemble the lamp if you cannot concentrate or feel unwell.
● Preparation
● Required tools and materials
The tools and materials mentioned are not included in the delivery. The details and values given are non-binding and for guidance only. The nature of the material depends on the individual circumstances on site.
- Pencil / Marking tool
- Voltage tester
- Screwdriver
- Electric drill
- Drill
- Edge cutter
- Ladder
● Before installation
Important: The electrical connection must be carried out by a qualified electrician or someone trained to perform electrical installations. This person must be familiar with the features of the light and the connection requirements.
□ Familiarise yourself with all instructions and diagrams in this manual as well as with the light
before installation.
Before installation, ensure that the cable that the light is to be attached to is not live. Remove its fuse or switch off the automatic cutout in the fuse box (0 position).
☐ Use the voltage tester to check that there is no voltage.
● Preparations for use
● Fitting the light
Note: The installation is the same for both models (3978/062L and 3958/062L).
☐ Remove the screws 3 visible on the side of the terminal housing 4 and take the installation frame 1 on the back off (see diagram).
☐ Mark the boreholes using the slotted holes provided for the screws in the installation frame 1.
☐ Now drill the screw holes (approx. 6 mm, depth approx. 40 mm). Ensure that the feed cable is not damaged.
☐ Insert the dowels into the drilled holes. Fasten the mounting bracket 1 in place with the supplied screws.
- Connect the light's connection cable to the mains connection cable using the insulating screw joint 2.
☐ Ensure that the cables have been connected in line with the correct colour coding.
Now connect the earthed conductor (green-yellow) to the earth terminal + labelled in the terminal housing 4 .
☐ Screw the light onto the installation frame 1 using the screws 3.
☐ Push the glass lampshade 6 over the lamp socket and fasten it with a ring nut 8 using the tool (see Fig.).
☐ Then insert the illuminant 9 into the lamp socket. To do so, use a dry, lint-free cloth. Check that it fits properly.
☐ Your lamp is now ready to use.
- Adjusting the joints
☐ The two joints 7 allow you to adjust the length, or the alignment of the light. The maximum length is approx. 1.19 m.
- Adjusting the spotlights
☐ Only change the direction of the spotlights 5 when the light is switched off. Allow the lamp to cool down completely.
☐ Hold the individual spotlights 5 at their base and then turn in the direction desired. The spotlights 5 can be turned approx. 270°.
- Changing the bulbs
CAUTION! DANGER OF ELECTRIC SHOCK!
When changing the bulbs, first disconnect the light from the mains supply. Remove its fuse or switch off the automatic cutout in the fuse box (0 position).
⚠️ CAUTION! RISK OF BURNS! Allow the lamp to cool down completely.
☐ Only change the bulb 9 when it has completely cooled down. Use a clean, lint-free cloth when changing light bulbs.
☐ Only use 230-240V \~ illuminants with a max. of 40 Watt and a G 9 socket.
☐ Now insert the new illuminant 9 into the socket. Check that it fits properly.
● Maintenance and Cleaning
CAUTION! DANGER OF ELECTRIC SHOCK!
Before cleaning the lamp make sure that it is isolated from the mains supply. Remove its fuse or switch off the automatic cutout in the fuse box (0 position).
⚠️ CAUTION! RISK OF BURNS! Allow the lamp to cool down completely.
CAUTION! DANGER OF ELECTRIC SHOCK!
For reasons of electrical safety, the light must never be cleaned with water or other fluids or be immersed in water. When cleaning, only use a dry, lint-free cloth.
☐ Do not use any solvents, petrol or similar. This would cause damage to the light.
- Disposal
The packaging and ancillary packing consist entirely of environmentally-friendly materials. They can be disposed of at your local recycling facility.

The symbol of the wheelie bin with the line through it means that, in the European Union, the product has to be disposed of in a separate refuse collection. This applies to the product and to all components bearing this symbol. Products marked in this way may not be disposed of along with normal domestic waste but have to be handed in at a recycling collection point for electrical and electronic appliances. Recycling helps to reduce the consumption of raw materials and to ease the burden on the environment.
- Information
guarantee
You receive a 36 month warranty on this product, valid from the date of purchase.
The device has been carefully produced under strict quality control.
Within the warranty period we shall rectify without charge all material and manufacturing defects. In the event of a defect arising during the warranty period, please send the device to the listed Service Centre address, making reference to the following article number: 3978/062L or 3958/062L.
Wear parts (such as bulbs) and damage caused by improper handling, non-observance of the operating instructions or unauthorised interference are excluded from the warranty.
The performance of services under the warranty does not extend or renew the warranty period.
Service
- Declaration of Conformity CE
This product fulfils the requirements of the applicable European and national directives (Electromagnetic Compatibility 2004/108/EC, Low Voltage Directive 2006/95/EC). Conformity has been demonstrated. The relevant declarations and documents are held by the manufacturer.
Uvod
Upute za pravilno korištenje ....Stranica 12
Obim isporuke....Stranica 12
59929 Brilon (Germany)
© by ORFGEN Marketing
Last Information Update · Stanje informacija