OBH NORDICA Light Line - Scale

Light Line - Scale OBH NORDICA - Free user manual and instructions

Find the device manual for free Light Line OBH NORDICA in PDF.

📄 20 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice OBH NORDICA Light Line - page 15
View the manual : Dansk DA English EN Suomi FI Norsk NO Svenska SV
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Electronic Bathroom Scale
Brand OBH Nordica
Model Light Line
Capacity 10 kg - 150 kg
Division (Interval) 100 g
Tolerance ± 1%
Display LCD
Power Supply 1 x 3V Lithium Battery CR2032
Auto Shut-off After 10 seconds of inactivity
Material Glass
Operation Tap to start (step-on activation)
Reset Procedure Tap center of scale until display shows "0.0"
Overload Indication Display shows "Err"
Low Battery Indication Display shows "Lo"
Cleaning Wipe with damp cloth; do not immerse
Use Place on even, flat, dry surface; stand still
Safety Not for use by persons with reduced capabilities without supervision
Environmental Disposal Dispose as electronic waste; remove battery
Warranty According to valid law; return to store of purchase

Frequently Asked Questions - Light Line OBH NORDICA

How do I reset the scale before first use?
Tap the center of the scale. The display will show four lines for about 3 seconds, then '0.0'. Let it automatically turn off. This ensures accurate weighing.
Why does the scale show 'Err'?
'Err' indicates the scale is overloaded. The maximum capacity is 150 kg. Remove weight immediately to avoid damage.
How do I change the battery?
When 'Lo' appears on the display, remove the battery compartment lid. Pull the black knob outward to release the old battery (see picture A). Insert a new CR2032 lithium battery by placing one edge under the electrode, then press the other edge down (pictures B and C). Replace the lid.
What should I do if the scale gives inconsistent readings?
Ensure the scale is on an even, flat, dry surface. Stand still with feet placed evenly. Avoid weighing after meals or with clothing. If moved, reset the scale before use.
Can I use the scale on carpet?
No, for accurate results always place the scale on a hard, flat, and dry surface.
How do I clean the scale?
Wipe with a slightly damp cloth and then dry with a soft cloth. Never immerse the scale in water or other liquids.
What is the tolerance of the scale?
The tolerance is ±1%. For example, if you weigh 70 kg, the display may show between 69.3 and 70.7 kg.
How long does the battery last?
Battery life depends on usage. The scale has an auto shut-off after 10 seconds to prolong battery life. Replace with a CR2032 battery when 'Lo' appears.
Is the scale suitable for children?
Children should be supervised to ensure they do not play with the appliance. The scale is not intended for use by persons with reduced capabilities without supervision.
What is the warranty on the OBH Nordica Light Line scale?
The warranty is according to valid law. Keep the machine-stamped receipt. For complaints, return to the store where purchased.

User questions about Light Line OBH NORDICA

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Scale in PDF format for free! Find your manual Light Line - OBH NORDICA and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. Light Line by OBH NORDICA.

USER MANUAL Light Line OBH NORDICA

light line // electronic glass scale //

OBH NORDICA Light Line - 1

Nice design //

OBH NORDICA Light Line - 2

Easy to read LCD display //

OBH NORDICA Light Line - 3

Capacity 150 kgs //

OBH NORDICA Light Line - 4

Automatic switch off after use //

Woman sitting on a large round exercise ball, wearing athletic wear (no text or symbols visible)

Type

CAUTION: Slippery when wet !

Billede A

Diagram of a cylindrical device with a battery and internal components, mounted on a base plate (no text or symbols)

Billede B

Simple line drawing of a circular device with a plus sign and connected tubing, mounted on a base (no text or symbols)

Billede C

OBH Nordica Denmark A/S

Ole Lippmanns Vej 1

2630 Taastrup

Tlf. 43 350 350

www.obhnordica.dk

Tekniske data

OBH Nordica 6251

CAUTION: Slippery when wet !

Bild A

Diagram of a cylindrical device mounted on a base with wires and a battery (no text or symbols)

Bild B

Simple line drawing of a circular object with a plus sign and a mechanical component attached (no text or symbols)

Bild C

Rengöring

OBH Nordica Sweden AB

Box 58

163 91 Spånga

Tfn 08-445 79 00

www.obhnordica.se

Tekniska data

OBH Nordica 6251

Apparaten ska kasseras som elektronikavfall

CAUTION: Slippery when wet !

Tips ved veiing

Bilde A

3D diagram of a cylindrical device with a base and top plate, no visible text or symbols

Bilde B

Technical line drawing of a mechanical assembly with a cylindrical component and mounting base (no text or symbols)

Bilde C

OBH Nordica Norway AS

Postboks 5443, Majorstuen

0304 Oslo

Tlf: 22 96 39 30

www.obhnordica.no

Tekniske data

OBH Nordica 6251

Apparatet skal avleveres som elektronisk avfall.

Min 10 kg / maks 150 kg med 100 g intervall.

VAROITUS! Liukas mä

Punnituksesta

Kuva A

Diagram of a cylindrical device with a battery and screw, mounted on a base plate (no text or symbols)

Kuva B

Simple line drawing of a circular object mounted on a base with a battery and a plus sign, no text or symbols present.

Kuva C

Puhdistus

Before you use the scale for the first time you should read the instructions carefully and save them for future use.

Since the scale is electronic you should be aware that the function can be affected by changes in temperature or if you move the scale. The function can also be affected by other electronic appliances as cell phones, heating coils, microwaves etc. Place the scale in a room with normal temperature and let it acclimatize for 24 hours before you use it for the first time.

Before the first use or if the scale has been moved always do this procedure, otherwise it may lead to wrongfull weighing. Start to reset the scale by tapping in the middle of the scale, the display flicker 4 lines for about 3 seconds, after that it shows "0.0", let it automatically turn off.

TAP TO START

CAUTION: Slippery when wet!

The tolerance of the scale is 1%, it means that if you weigh 70 kg it may vary between 69,3 and 70,7 kg. The scale has an interval of 100 g, so if you weigh 70,75 the display will show either 70,7 or 70,8 kg (with 1% tolerance).

Helpful hints

To ensure reliable readings, always stand completely still on the scale, otherwise the result may be misleading. Clothing or just eaten meals can have effect on the readings. If you want to monitor your weight during a long period of time you should consider weighing your self approximately the same time of the day each time, preferable without clothes and without moving the scales in between.

Use

  1. Place the scale on an even flat surface and reset it as described before. Activate the scale by lightly tapping the centre of the scale. When the display shows "0.0" it is ready to be used.
  2. Step on the scale, place your feet at the same position each time and divide the weight between both legs and between toe and heel. Remember to stand completely still. The display fl inker“---” for 3 seconds and your measurement will appear on the display.
  3. When you have stepped off the scale your weight can be seen for a few seconds and after that the display will show "0.0". The display will automatically shut off after 5 seconds which prolongs the lifetime of the battery.

If you overload the scale (max 150 kg) the display will show "Err".

Important!

To achieve a correct result you ought to follow these guidelines:

  • Place the scale on an even, fl at and dry surface.
  • Place the feet on the same place on the scale every time.
  • Divide your weight evenly between toe and heel.
  • Stand still.

If the scale is overloaded the display will show "Err".

Battery

When the batteries need to be changed, the display will show “Lo”. Remove the battery compartment lid, remove the old battery by pull outwards the little black knob which is on the side of the battery slot and coax out the battery (pic A). Place a new lithium battery type CR2032 by putting one edge under the electrode, then press down the other edge inside the slot from the knob side (pic B and C), then put the battery compartment lid back on.

the knob electrode picture A

Diagram of a cylindrical device with a base, labeled 'picture B' below (no other text or symbols)

Diagram of a circular device mounted on a base with a plus symbol, labeled 'picture C' below (no readable text or symbols on the device itself)

Cleaning

  1. Read the instruction manual carefully before use, and save it for future use.
  2. The appliance must not be immersed into water or other liquids. Should it get wet, it must be wiped off immediately, as liquids contain minerals which may result in rust in the electronic parts or which may totally destroy the electronic parts.
  3. If the appliance gets dirty, the dirt can be wiped off with a slightly humid cloth, and then wiped with a dry cloth.
  4. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
  5. Children should be supervised to ensure that they do not play with the appliance. Children are not always able to understand potential risks. Teach children a responsible handling of electrical appliances.
  6. The appliance must not be used if it has been dropped on the floor, or if it is clear that the appliance is damaged. In such cases the appliance should be handed in for repair at the distributor where it was bought.
  7. Use only new batteries of the correct size. Used batteries should always be removed, as they may leak chemicals which may damage the circuitry of the appliance.
  8. The appliance is for domestic use only.
  9. If the appliance is used for other purposes than intended, or is it not handled in accordance with the instruction manual, the full responsibility for any consequences will rest with the user. Any damages to the product or other things are not covered by the warranty.

Environmental considerations and disposal of batteries

OBH NORDICA Light Line - Environmental considerations and disposal of batteries - 1

When substituting batteries it is essential to take the environment into consideration. Used batteries must never be disposed of with domestic garbage. Batteries marked with the symbol indicating separate waste collection must be returned to one of the authorized collection points. Batteries must be removed from the appliance before it is disposed of. Also take care that the batteries are not expired or become worn-out since there may then be a risk that the batteries will leak acid. Check the validity date printed on the batteries.

Disposal of the appliance

OBH NORDICA Light Line - Disposal of the appliance - 1

Legislation requires that all electrical and electronic equipment must be collected for reuse and recycling. Electrical and electronic equipment marked with the symbol indicating separate collection of such equipment must be returned to a municipal waste collection point.

Warranty

Claim according to valid law. Machine stamped receipt shall be enclosed if you wish to make a complaint. The appliance shall be returned to the store where it's purchased.

OBH Nordica Sweden AB

Box 58

163 91 Spånga

Tfn 08-445 79 00

www.obhnordica.se

Technical data

OBH Nordica 6251

Must be discarded as electronic waste

Min 10 kg, max 150 kg with 100 g interval.

Tolerance ± 1%

LCD display.

3V lithium battery type CR2032

Auto shut off after 10 seconds.

OBH NORDICA Light Line - Technical data - 1

With reservation for running changes.

Digital kitchen stainless steel digital counter with 'OBH NORDICA' label and 0.0 kg mark (no additional text or symbols)

Woman sitting on a fitness ball, wearing athletic wear (no text or symbols visible)

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : OBH NORDICA

Model : Light Line

Category : Scale