HUM 770 - Humidifier HYUNDAI - Free user manual and instructions
Find the device manual for free HUM 770 HYUNDAI in PDF.
| Product Type | Ultrasonic Humidifier |
| Brand | Hyundai |
| Model | HUM 770 |
| Dimensions (W x H x D) | 24.5 x 33 x 17 cm |
| Weight | 1.6 kg |
| Power Consumption | 30 W (max) |
| Standby Power Consumption | < 0.50 W |
| Water Tank Capacity | 5.2 L |
| Operating Time per Fill | 17 - 52 hours |
| Noise Level | < 35 dB |
| Color | White-Purple |
| Mist Output Levels | 4 levels: Low, Middle, Senior, High |
| Humidistat Range | 40 - 99% RH (in 5% steps) |
| Timer | 1 - 24 hours |
| Ionizer | Built-in (can be turned on/off) |
| Automatic Shut-Off | Yes, when water tank is empty (with indicator) |
| Transducer Cleaning | Clean weekly with abluent; never scrape |
| Water Basin Cleaning | Clean weekly with soft cloth and abluent |
| Safety Features | Do not immerse base; disconnect power before cleaning; automatic waterless protection |
| Included Accessories | Cleaning brush, nozzle, mist baffle, tank cover |
| Repairability | Consumer-replaceable parts: none; contact authorized service for repairs |
Frequently Asked Questions - HUM 770 HYUNDAI
User questions about HUM 770 HYUNDAI
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Humidifier in PDF format for free! Find your manual HUM 770 - HYUNDAI and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. HUM 770 by HYUNDAI.
USER MANUAL HUM 770 HYUNDAI
POKYNY K POUŽITÍ
PRINCIP FUNGOVÁNÍ
Caution: DISCONNECT POWER SUPPLY BEFORE CLEANING OR SERVING UNIT.
DO NOT IMMERSE THE BASE OF UNIT IN WATER.
DO NOT OPERATE WITH DAMAGED CORD OR PLUG.
CAUTION: SEDIMENT ON THE TRANSDUCER WILL CAUSE THE UNIT TO WORK IMPROPERLY. CLEAN THE TRANSDUCER AND WATER BASIN FREQUENTLY. NOTE: NEVER SCRAPE THE TRANSDUCER.
POKYNY NA POUŽITIE
PRINCÍP FUNGOVANIA
Caution: DISCONNECT POWER SUPPLY BEFORE CLEANING OR SERVING UNIT.
DO NOT IMMERSE THE BASE OF UNIT IN WATER.
DO NOT OPERATE WITH DAMAGED CORD OR PLUG.
CAUTION: SEDIMENT ON THE TRANSDUCER WILL CAUSE THE UNIT TO WORK IMPROPERLY. CLEAN THE TRANSDUCER AND WATER BASIN FREQUENTLY. NOTE: NEVER SCRAPE THE TRANSDUCER.
INSTRUKCJE UŻYTKOWANIA
ZASADY DZIAŁANIA
WŁAŚCIWOŚCI I FUNKCJE
OPTYMALNY POZIOM WILGOTNOŚCI
CAUTION: SEDIMENT ON THE TRANSDUCER WILL CAUSE THE UNIT TO WORK IMPROPERLY. CLEAN THE TRANSDUCER AND WATER BASIN FREQUENTLY. NOTE: NEVER SCRAPE THE TRANSDUCER.
Dear customer, thank you for purchasing our product. Please read the operating instructions carefully before putting the appliance into operation and keep these instructions including the warranty, the receipt and, if possible, the box with the internal packing.
GENERAL SAFETY INSTRUCTIONS

- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
- Before replacing accessories or accessible parts, which move during operation, before assembly and disassembly, before cleaning or maintenance, turn off the appliance and disconnect it from the mains by pulling the power cord from the power socket!
- Do not leave the appliance plugged in power supply without supervision!
- If the power cord of the appliance is corrupted, it has to be replaced by the manufacturer, its service technician or a similarly qualified person so as to prevent dangerous situations.
- Never use the appliance if its power cord or plug is damaged, if it does not work properly, if it fell down and was damaged and it is leaking. In this case take the appliance to a special service to check its safety and proper function.
- The appliance is designed exclusively for private use and for the envisaged purpose. This appliance is not fit for commercial use.
- Keep it away from sources of heat, direct sunlight, humidity (never dip it into any liquid) and sharp edges. Do not use the appliance with wet hands. If the appliance is humid or wet, unplug it immediately. Do not put it in water.
- When cleaning or putting it away, switch off the appliance and always pull out the plug from the socket (pull on the plug, not the cable) if the appliance is not being used and remove the attached accessories.
- Do not operate the machine without supervision. If you should leave the workplace, always switch the machine off or remove the plug from the socket (pull the plug itself, not the lead).
- Check the appliance and the cable for damage on a regular basis. Do not use the appliance if it is damaged.
- Pay careful attention to the following "Special Safety Instructions for this unit".
SPECIAL SAFETY INSTRUCTIONS FOR THIS UNIT
- Operate the appliance only in accordance with the specifications on the rating plate.
- Do not attempt to refill humidifier without first unplugging the unit from it's electrical outlet. Be sure to pull by the plug and not the cord.
- NEVER drop or insert any object into any openings. DO NOT place hands, face, or body directly over or near Moisture Outlet while unit is in operation. DO NOT cover Moisture Outlet or place anything over it while the unit is operating.
-
Always place humidifier on a firm, flat, level surface. A waterproof mat or pad is recommended for under the humidifier. NEVER place it on a surface that may become damaged by exposure to water and moisture (i.e. finished floor).
-
DO NOT allow the Moisture Outlet to directly face the wall. Moisture could cause damage, particularly to wallpaper.
- NEVER tilt, move, or attempt to empty unit while it is operating. Shut off and unplug before removing the water tank and moving the unit.
- NEVER use detergents, petrol, glass cleaner, furniture polish, paint thinner, or other household solvents to clean any part of the humidifier.
- Excessive humidity in a room can cause water condensation on windows and some furniture. If this happens, turn the humidifier OFF
- Don't add into the water any additive that are not produced or supervised by the supplier.
- Keep the cleaning agents away from children.
- Any alternations or refit of the humidifier without specific authorization of the supplier may cause inconveniences or harms to users.
- Turn off the humidifier and pull out the power plug in case of any abnormal sounds or smells during the operation.
- Keep cleaning agents away your mouth and eyes. If your mouth and eyes come into contact with the cleaning agents by accident, please wash with tap water immediately, or an immediate medical check-up is required in case the circumstance is serious.
• Turn off the machine and pull out the power plug before cleaning, refilling or moving the machine. - Don't touch the water in the water basin or any components in the water with any parts of your body when the humidifier is working.
- Don't turn on the humidifier when there is no water in the water basin.
- Don't scrape the transducer with hard objects.
- Prevent the water from flowing or spilling into the interiors of the base to avoid any damages to the components.
- Don't use the humidifier in high-humidity environment such as bathroom etc.
- Don't put the humidifier on the floor being made of wood or bamboo and also the similar materials.
- Do not add any Additives such as bath salt or bath oil into the water.
- Place the unit on the flat surface and keep the machine at lease 2 meters far away from the furniture and the other electrical appliances.
DESCRIPTION OF THE CONTROLS
1 Nozzle
2 Handle
3 Mist baffle
4 Watter tank
5 Panel of tank
6 Tank cover
7 Handle of tank cover
8 Valve cap
9 Water inlet
10 Wind exit
11 Fixer of floater
12 Floater
13 Cleaning brush
14 Base
15 Control panel
16 Power cord

ENG - 24
INSTRUCTIONS FOR USE
OPERATION PRINCIPLE
Ultrasonic humidifiers atomize the water into ultramarine of about 1-5um using the ultrasonic high frequency oscillation principle and diffuse the water mist into the air by means of the pneumatic device to uniformly humidify the air. As a proven technology, the ultrasonic technology has been widely used in various fields.
FEATURES AND FUNCTION
- Automatic lack-water security protection: Water level protection switch will stop the transducer from atomizing when the water level in the water basin is below the pre-calculated level to protect the transducer from being burned down, while the power light is still on, with the blower fan keeping working.
- Mist volume adjustable to make you comfortable.
- Transparent water tank to ensure water level visible.
• High efficient in humidification with large output. - Low energy consumption, save 85-90 percent of electricity of normal stream humidifier.
- Long lifetime
• Automatic control to humidity level, lack-water security protection.
Relative humidity refers to the ratio of the water content to the saturated vapor content in the air under a specific temperature and in a specific space. It is generally marked as %RH, such as 45%RH. Air always contains water vapor and its percentage varies with the temperature. The higher the temperature is, the more water vapor is absorbed by the air. That is why we use the concept relative humidity. In winter, when the outdoor cold air enters into the room, it will be heated up to a temperature adaptable to the indoor air, and the relative humidity will drop at the same time. In order to maintain a healthy interior ambient humidity, adding the water or water vapor into the air artificially is required---that is air humidification.
Ideal Relative Humidity Levels under Various Conditions (for reference only):
-Ideal ambient humidity for people: 45% RH—65% RH
- Ambient humidity most favorable for disease prevention and treatment: 40% RH—55% RH
-Computer and communication appliances: 45% RH—60% RH
-Furniture and musical instruments: 40% RH—60% RH
-Libraries, art galleries and museums: 40% RH—60 RH
Function of Ultrasonic Humidifier:
- To increase and to regulate relative humidity of the room air
• To eliminate electrostatic charges
• To prevent different diseases
• To keep your appearance fit and protect your skin
• To adjust room temperature
- This humidifier should be placed under ambient temperature for half an hour before it is put into use for the first time.
- The desired operating environment for this humidifier is: temperature: 5 - 40 °C and relative humidity 80%RH max.
- Use clean water with temperature below 40^ , purified water is recommended.
- Check the water basin, make sure it is clear.
CONTROL
Operation steps:
1) Take the water tank (4) out of the base (14), revolve the Valve-cup by the directions of LOOSEN and FASTEN (8), and fill the water tank (4) with clear water. Close the Valve-cup (8), and put the water tank (4) onto the base (14) carefully.
2) Put the Nozzle (1) into the socket on top of the water tank (4).
3) Connect the main supply (17), switch on the unit (15) (NEVER RUN THE UNIT WHEN THERE IS NO WATER IN WATER BASIN), the LED display will on for 2 seconds then be off. The unit stands by.
4) ON/OFF: It takes charge the electric supply of the whole unit. When press ON, the display is on, the machine operates with the lowest mist output, at the same time the fan motor works. When it is OFF, all the functions are invalid, and the display is off.
5) PRESET: When the unit stands by, press this button. The preset time can be chosen from 1 hour to 24 hours. The preset time will be counted down to work with the highest mist output. At the same time, Ionizer works, the humidity level is 99RH%.
6) MIST: 4 levels from Low, Middle, Senior to High for different mist output. And the corresponding power is from 17-19W (L), 19-23W (M), 23-27W (S) to 27-30W (H).
7) TIMER: Settings from 1-24 hours. Timer can turn off the appliance when set time expires. 0:00 means cancelling the settings. 3 seconds after your settings, the timer function will be counted down to work by minutes and will display with current humidity by turns for 5 seconds if having set the humidity level.
8) HUMIDISTAT: Function for automatic humidity control by setting value. You cen set from 40 -95RH% by 5RH%. When symbol „Humistat“ turn out means cancelling this settings. 3 seconds after your settings, the humidistat works. It stops when the current humidity is more than the setting level, but the fan motor will keep working for 5 minutes. And continue operate when the current humidity is 2RH% less than the setting level.
9) ANION: When the machine stands ON, press the ANION button, it works whatever it is humidifying. The fan motor works at the same time. If it is not humidifying, when the ANION is off, the fan motor stops. But if it is humidifying, when the ANION is off, the fan motor still works.
10) Protection when waterless: When the tank is out of water, the Waterless lamp is on. And the machine stops. Then the settings of TIMER and HUMIDISTAT will be cancelled. When filling the water, it should be reset for the functions.
TROUBLE SHOOTING GUIDE
In case your humidifier does not work properly, please examine your machine before asking for maintenance service.
| Trouble | Possible reasons Shooting Way | |
| LED display is off No power su | pply Connect power supply | |
| Not press ON Switch on | ||
| LED display is on, no mist no wind | No water in water tank Fill water into water tank | |
| Too much water in the water basin | Pull out some water from the water basin, closed the cover of water tank tightly. | |
| LED display is on, no mist but with wind | Mist output is set on the lowest level | Adjust the mist output |
| LED display is on, with water but shows waterless | Floater is interrupted Waver the floater, keep it free | |
| Abnormal smell mist New unit | Take out water tank, open | cover, let it stays 12 hours in cool position |
| Dirty water or long time stay-ing water | Cleaning water tank, fill in clear water | |
| Mist fog is too small Too much | scale in the water basin | Clean transducer |
| Water is too dirty or water kept too long time in the tank | Clean water tank, change to fresh clear water | |
| Water is too cold Add some warm water inside | ||
| Abnormal noise Resonant in w | water tank when water is too lower | Fill water tank with water |
| Unit is on a unstable surface Move the unit to a stable flat surface | ||
| Mist coming out around the nozzle | There are apertures between the nozzle and water tank | Dip the nozzle in water for a while and then fix it to the socket on water tank |
| Water doesn't come down to basin | Backup by filter Rinse the filter by tap water | |
| Display shows blinking digital 30%RH | Current humidity level is lower than 30% | Just keep it working |
| Display shows Sd (Sensor defect) | Poor contact for humidity sen-sing element | Reinstall it |
| Open or Short for Temperature Resistance | Replace it | |
CLEANING AND MAINTENANCE
In case when the water is hard which means water contains too much calcium and magnesium, they can cause “white powder” problem and give heavy scales on the surface of water basin, transducer and inner surface of the water tank. Scales on the surface of transducer will unable the unit work properly.
We recommend:
1) Use cold boiled water or distilled water.
2) Clean the transducer, water tank and basin unit every week.
3) Change the water in water tank more often to keep it fresh.
4) Make sure to pull out the water from the water tank and dry the water basin before you store the unit unused for a long period of time.
5) Clean the whole unit, and make sure that all parts of the unit are dried completely before unused for longer period of time.
6) Do not use the chemical for cleaning.
How to clean the transducer:
1) Put 5-10 drops of cleaning abluent on the surface of the transducer, wait for 2-5 minutes;
2) Brush out the scale on the surface.
3) Rinse the transducer with clean water.
How to clean the basin unit:
1) Cleaning the water basin with soft cloth and the cleaning abluent if there is scale in it.
2) If the scale is covered on the security switch, drop the cleaning abluent on the scale and clean it out with the brush.
3) Rinsing the water basin with clean water.
Technical specifications
- Operating time for 17 - 52 hours without filling watter
- Container volume 5,2 l
• Automatic switch-off with indicator when lack off water - Mist adjustment with illumination
- Presetting for humidifying and anion function
- Timer from 1 to 24 hours
-
Humidistat from 40 RH% to 99 RH% by increased 5 RH% per choice
-
Instaled ionizer for fresh air
- Elegant look
- Very silent
- Low consumption
• Color: white-purple - Noise level: < 35 dB
• Power drain: 30W - Size: 24,5 x 33 x 17 cm, weight: 1,6 kg Input in standby mode is < 0,50 W.
We reserve the right to change technical specifications. We reserve the right to change technical specifications. Replacement of parts that require intervention in the electric part of the appliance must be carried out by a specialized service! Failure to comply with the instructions of the manufacturer will lead to expiration of the right to guarantee repair!

WARNING: Do not use this product near water, in wet areas to avoid fire or injury of electric current. Always turn off the product when you don't use it or before a revision. There aren't any parts in this appliance which are reparable by consumer. Always appeal to a qualified authorized service. The product is under a dangerous tension.
Old electrical appliances, used batteries and accumulators disposal

This symbol on the product or on its packaging indicates that this product (or battery/accumulator) shall not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. The recycling of materials will help to conserve natural resources. For
more detailed information about recycling of this product, please contact your local Civic Office, your household waste disposal service or the shop where you purchased the product.
WARNINGS AND SYMBOLS USED ON THE APPLIANCE, PACKAGING OR IN THE INSTRUCTIONS MANUAL:
HOUSEHOLD USE ONLY; DO NOT IMMERSE IN WATER OR OTHER LIQUIDS;


TO AVOID DANGER OF SUFFOCATION, KEEP THIS PLASTIC BAG AWAY FROM BABIES AND CHILDREN. DO NOT USE THIS BAG IN CRIBS, BEDS, CARRIAGES OR PLAYPENS. THIS BAG IS NOT A TOY.
The symbol indicates a WARNING.
HASZNÁLATI TUDNIVALÓK
MÜKÖDÉSI ELV
CAUTION: SEDIMENT ON THE TRANSDUCER WILL CAUSE THE UNIT TO WORK IMPROPERLY. CLEAN THE TRANSDUCER AND WATER BASIN FREQUENTLY. NOTE: NEVER SCRAPE THE TRANSDUCER.