AMICA MD 1014 - Food processor

MD 1014 - Food processor AMICA - Free user manual and instructions

Find the device manual for free MD 1014 AMICA in PDF.

📄 19 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice AMICA MD 1014 - page 12
View the manual : English EN Polski PL
Pick your language and provide your email: we'll send you a specifically translated version.
Product TypeFood Processor (Hand Mixer)
BrandAmica
ModelMD 1014
Rated Voltage220-240V ~50 Hz
Rated Power250 W
Speed Settings5 speeds + Turbo mode
Maximum Operating Time3 minutes at speeds 1-5; 1 minute at Turbo; then 30-minute cool down
Included Accessories2 stainless steel beaters, 2 stainless steel dough hooks
Power Cord LengthApproximately 1.1 m
MaterialPlastic body with metal attachments
Safety FeaturesClass II fire protection; automatic shut-off; overload protection (cool down required)
CleaningMotor unit: wipe with damp cloth; accessories: hand wash or dishwasher up to 45°C
Intended UseHousehold only
CertificationsCE, RoHS, Low Voltage Directive 2014/35/EC, EMC 2014/30/EC, ErP 2009/125/EC
Product WeightApproximately 1.5 kg (estimated)
Dimensions (HxWxD)Approximately 20 x 15 x 25 cm (estimated)
Attachments ReleaseYes, press button to release
Turbo ButtonYes, press and hold while operating at speeds 1-5
Replacement Parts AvailabilityContact Amica service or authorized dealers

Frequently Asked Questions - MD 1014 AMICA

What is the maximum operating time for the Amica MD 1014?
You can operate the mixer for up to 3 minutes at speeds 1-5, and only 1 minute at Turbo speed. After use, let it cool down for 30 minutes before using again.
How do I attach the beaters or dough hooks?
Insert the attachment with the ring into the socket marked with a matching symbol. Push until you hear a click. If it’s difficult, twist slightly while pushing.
Can I wash the motor unit in water?
No, never immerse the motor unit in water. Wipe it with a damp cloth and dry thoroughly. Only the attachments (beaters, dough hooks) can be washed in water or dishwasher up to 45°C.
What should I do if the blades get jammed?
Immediately unplug the appliance. Then carefully remove the blockage. The blades are very sharp, so exercise caution.
Can I blend hot liquids with this food processor?
No, do not blend boiling or very hot food. Allow food to cool before mixing.
How do I use the Turbo function?
First, set the speed slider to any position 1-5. Then press and hold the Turbo button to activate maximum speed. Release to return to the selected speed.
Is the Amica MD 1014 safe for children to use?
Children aged 8 years and older can use it under supervision. The appliance must not be used by children without supervision, and children should not play with it.
What accessories come with the MD 1014?
It includes 2 stainless steel beaters and 2 stainless steel dough hooks. No additional accessories are provided.
Can I use the mixer for kneading bread dough?
Yes, use the dough hooks at speed 3 or 4 for mixing dough. Do not exceed 3 minutes of continuous operation.
What does the crossed-out wheeled bin symbol mean?
It means the appliance must not be disposed of with regular household waste. Take it to a recycling center for electrical and electronic equipment.

User questions about MD 1014 AMICA

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Food processor in PDF format for free! Find your manual MD 1014 - AMICA and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. MD 1014 by AMICA.

USER MANUAL MD 1014 AMICA

natural_image White PCO® electric mixer with a metal hand mixer and coiled cord (no text or symbols visible)

MD 1011

MD 1012

MDT 1013

MD 1014

PL INSTRUKCJA OBSŁUGI....3

EN OPERATING INSTRUCTIONS....12

Amica Food mix 1 2 3 4 5

AMICA MD 1014 - 2

natural_image Illustration of a coiled wire or cable with a numbered label (6) pointing to it, no text or symbols present.

1

AMICA MD 1014 - 3

natural_image White 3D-rendered object with two circular eyes and two coiled springs, labeled with number 2 (no text or symbols on the object itself)

AMICA MD 1014 - 4

natural_image Close-up of a white ergonomic device with orange buttons and a black arrow pointing to it, labeled '012345' (no readable text or symbols beyond basic labels)

AMICA MD 1014 - 5

natural_image Close-up of a white ergonomic device with orange buttons and a black arrow pointing to a small circular icon (no text or symbols visible)

AMICA MD 1014 - 6

natural_image Close-up of a white 3D object with orange circular and rectangular buttons, no visible text or symbols

GRATULUJEMY WYBORU SPRZĘTU MARKI AMICA

SZANOWNI PAŃSTWO!

natural_image Recycling symbol composed of three chasing arrows forming a triangle (no text or labels)
natural_image Symbol of a trash bin crossed out by two crossed lines (no text or numbers present)

Illustrated cooking process steps showing mixing, cleaning, and drying steps with checkmark and red X mark indicators

CZYSZCZENIE I KONSERWACJA

THANK YOU FOR PURCHASING AN AMICA APPLIANCE

DEAR CUSTOMER,

Your Amica appliance is exceptionally easy to use and extremely efficient. Before being packaged and leaving the manufacturer, this appliance was thoroughly checked with regard to safety and functionality.

Before using the appliance, please carefully read these Operating Instructions

Symbols appearing in these instructions have the following meaning:

AMICA MD 1014 - DEAR CUSTOMER, - 1

Important information concerning proper operation of the appliance and your personal safety.

AMICA MD 1014 - DEAR CUSTOMER, - 2

Risks resulting from improper operation of the appliance. Activities that must be performed by a qualified technician.

AMICA MD 1014 - DEAR CUSTOMER, - 3

Tips on how to use the appliance.

AMICA MD 1014 - DEAR CUSTOMER, - 4

Information on how to protect the environment.

AMICA MD 1014 - DEAR CUSTOMER, - 5

This indicates actions that must not be performed by the user.

CONTENTS

SPECIFICATION......12

SAFETY INSTRUCTIONS FOR USE....13

DISPOSING/SCRAPPING OF USED EQUIPMENT....15

OPERATION....17

CLEANING....18

SPECIFICATION / FEATURES AND COMPONENTS

Type MD 1011 / MD1012 / MDT 1013 / MD 1014

Rated voltage 220-240V \~50 Hz

Rated power 250

Speed adjustment Yes, 5 speed

Turbo speed Yes

Beaters Yes - 2 pcs Stainless Steel

Beaters Yes / 2 pcs Stainless Steel

Power cord \~1.1m

AMICA MD 1014 - SPECIFICATION / FEATURES AND COMPONENTS - 1

The appliance is designed for household use only.

AMICA MD 1014 - SPECIFICATION / FEATURES AND COMPONENTS - 2

The manufacturer reserves the right to introduce changes, which do not affect operation of the appliance.

The pictures in this operating instructions are for illustration only. Full list of the appliance accessories may be found in an appropriate section of this operating instructions.

Note! To minimize the risk of fire, electric shock or injury:

Carefully read this instruction before using the appli- ance.

Children do not realize the dangers that can arise when using electrical appliances; therefore keep the appliance out of reach of children.

Do not immerse the body of the appliance in water or other liquids. Immersing in water may cause an electric shock.

If water spills on the external components of the appliance, dry it thoroughly before switching back on. Do not touch wet surfaces in contact with the appliance connected to power supply, immediately disconnect it from the mains.

Do not use the appliance if it shows any signs of damage to the power cord, or if the appliance has been dropped on the floor.

After use, always pull out the plug from the socket, and also in case of any malfunction, before cleaning or before changing accessories.

When pulling out the plug from the wall outlet, never pull by the cord, only the plug, holding the socket with your other hand.

The appliance is Class II fire protection electrical equipment.

Do not attempt to remove any parts of the housing.

To prevent damage to the power cord, do not place it over sharp edges or close to hot surfaces.

Do not expose the appliance to rain or humidity, and do not use it outdoors. Do not operate the appliance with wet hands.

If the power cord or plug is damaged, it should be replaced by a professional repair shop in order to avoid hazard.

Using attachments that were not supplied with the product may cause damage to the appliance.

Never place the appliance on hot surfaces.

Take caution when cleaning the attachments

AMICA MD 1014 - SPECIFICATION / FEATURES AND COMPONENTS - 3

AMICA MD 1014 - SPECIFICATION / FEATURES AND COMPONENTS - 4

AMICA MD 1014 - SPECIFICATION / FEATURES AND COMPONENTS - 5

AMICA MD 1014 - SPECIFICATION / FEATURES AND COMPONENTS - 6

Never leave the appliance plugged in to power without supervision.

This appliance is not intended for use by persons (including children) with physical, mental or sensory handicaps, or by persons inexperienced or unfamiliar with the appliance, unless under supervision or in accordance with the instructions as communicated to them by persons responsible for their safety. Children shall not play with the appliance.

Pull the plug from the wall outlet before replacing accessories.

This appliance can be used by children aged 8 years and older or by persons with physical, mental or sensory handicaps, or by those who are inexperienced or unfamiliar with the appliance, provided they are supervised or have been instructed how to safely use the appliance and are familiar with risks associated with the use of the appliance. Ensure that children do not play with the appliance. Do not allow children to clean and maintain the appliance unless they are 8 years or older and are supervised by a competent person.

Ensure that the appliance is used on a clean, dry and level surface.

AMICA MD 1014 - SPECIFICATION / FEATURES AND COMPONENTS - 7

AMICA MD 1014 - SPECIFICATION / FEATURES AND COMPONENTS - 8

AMICA MD 1014 - SPECIFICATION / FEATURES AND COMPONENTS - 9

AMICA MD 1014 - SPECIFICATION / FEATURES AND COMPONENTS - 10

To turn on the appliance, move the slider (Fig. 1 pos. 9) to a position in the range 1-5, but you can also use the "TURBO" speed (Fig. 1 pos. 10). To use the "TURBO" speed you need to first set the appliance to any speed in the 1-5 range. To turn off the appliance, move the slider (Fig. 1 pos. 9) to the "0" position. You can completely shut down the appliance by disconnecting it from the power supply.

Do not blend boiling food.

If blades get jammed pull the plug out of the socket before attempting to clean the attachment. Exercise caution. Blades are very sharp.

During operation do not touch the blades and pay special attention to the long hair and garments.

Some attachments are equipped with sharp blades. Be cautious when using them.

AMICA MD 1014 - SPECIFICATION / FEATURES AND COMPONENTS - 11

Do not exceed the operating time and the quantity of blended products listed in the table.

AMICA MD 1014 - SPECIFICATION / FEATURES AND COMPONENTS - 12

Use only matching accessories and do not use different accessories at the same time.

AMICA MD 1014 - SPECIFICATION / FEATURES AND COMPONENTS - 13

Do not operate the appliance for more than 3 minutes at speeds 1-5, or for more than 1 minute at TURBO speed.

AMICA MD 1014 - SPECIFICATION / FEATURES AND COMPONENTS - 14

Allow the appliance to cool down to room temperature before using it again.

AMICA MD 1014 - SPECIFICATION / FEATURES AND COMPONENTS - 15

During operation, do not touch any components except the motor unit and/or container. Other components may cause danger to health and / or life during operation.

The appliance is designed for blending / mixing food, do not use it for other purposes.

UNPACKING

AMICA MD 1014 - UNPACKING - 1

natural_image Simple line drawing of a three chasing recycling symbol (no text or labels)

During transportation, protective packaging was used to protect the appliance against any damage. After unpacking, please dispose of all elements of packaging in a way that will not cause damage to the environment.

All materials used for packaging the appliance are environmentally friendly; they are 100% recyclable and are marked with the appropriate symbol.

Important! Packaging materials (bags, polyethylene, polystyrene, etc.) should be kept away from children during unpacking.

DISPOSAL OF OLD APPLIANCE

AMICA MD 1014 - DISPOSAL OF OLD APPLIANCE - 1

natural_image Symbol of a trash bin crossed out by two diagonal lines (no text or labels)

AMICA MD 1014 - DISPOSAL OF OLD APPLIANCE - 2

In accordance with European Directive 2012/19/EU and local legislation regarding used electrical and electronic goods, this appliance is marked with the symbol of the crossed-out waste container. This marking indicates that the appliance must not be disposed of together with other household waste after it has been used.

The user is obliged to hand it over to waste collection centre collecting used electrical and electronic goods. The collectors, including local collection points, shops and local authority departments provide recycling schemes.

Proper handling of used electrical and electronic goods helps avoid environmental and health hazards resulting from the presence of dangerous components and the inappropriate storage and processing of such goods.

OPERATION

Features and components (Figure 1).

1 - Speed control switch
2 - Attachment release button
3 - Motor unit
4 - Beaters (2 pcs.)
5 - Turbo button
6 - Dough hooks (2 pcs.)

Before first use

● After unpacking the appliance, make sure that all the attachments are included and there are no visible signs of damage.
● Before first use, wash in hot water all the attachments which come into contact with food.
● Before using the hand mixer, pre-mix all loose ingredients such as cocoa, flour.

How to use your appliance

- Depending on the ingredients to be mixed, inserts beaters or dough hooks in the appropriate sockets of the motor unit. Each of the sockets is marked to help you match an attachment to the socket (Fig. 2).

AMICA MD 1014 - How to use your appliance - 1

Insert the attachment with the ring in the socket marked and insert the other attachment in the socked marked.

Push the attachments all the way in until they are fully seated and you will hear a click. If you have difficulty inserting the attachments into the sockets turn them slightly when pressing.

  • Place the food in a suitable container.
    ● Plug the appliance into a power outlet.
  • Immerse the attachments in the container and turn on the appliance by moving the switch (Fig. 3) to the desired position 1 to 5.

AMICA MD 1014 - How to use your appliance - 2

Use lowest speed first. The appliance is equipped with a TURBO button — this mode can only be activated for a maximum of 60 seconds, as longer use risks damaging the appliance. You can use the TURBO function when the appliance operates at speed 1-5 by pressing and holding down the Turbo button (Fig. 4).

  • When you have finished, move the slider (Fig. 3) to "0" position.
  • Press the release button (Fig. 5) to remove the attachments from the appliance.
  • Unplug the appliance.

Appliance speeds explained

Speed Application
1Initial speed to evenly distribute the ingredients. Use this speed to mix ingredients such as flour, butter or potatoes.
2Use this speed mix liquids.
3Use this speed to whip or beat ingredients for dough and bread.
4Use this speed to whip ingredients for cakes and desserts.
5Use this speed to whip eggs, icing, cream or make purée.
Turbo Similar to speed 5.

AMICA MD 1014 - Appliance speeds explained - 1

Note!

Do not operate the appliance for more than 3 minutes at speeds 1-5, or for more than 1 minute at TURBO speed. Leave the appliance to cool down to room temperature for about 30 minutes after each use.

AMICA MD 1014 - Note! - 1

Note!

Be careful when adding loose ingredients, such as cocoa, flour, etc.

AMICA MD 1014 - Note! - 1

natural_image Illustration showing food preparation steps: adding granular material into a bowl, using a blender, and adding a lamp to a bowl (no text or symbols)

AMICA MD 1014 - Note! - 2

natural_image Illustration showing a blender being poured into a bowl and then being stirred with spoons (no text or symbols)

CLEANING AND CARE

● Unplug the appliance from the wall outlet.
- Remove the attachments.
- Wipe the appliance with a damp cloth and then dry thoroughly. Do not immerse the appliance motor unit in water or any other liquid.
- Wash other components in warm water with mild detergent and then dry thoroughly.
- Some parts of the appliance can be washed in the dishwasher at a maximum temperature of 45°C.

AMICA MD 1014 - CLEANING AND CARE - 1AMICA MD 1014 - CLEANING AND CARE - 2AMICA MD 1014 - CLEANING AND CARE - 3
AMICA MD 1014 - CLEANING AND CARE - 4AMICA MD 1014 - CLEANING AND CARE - 5AMICA MD 1014 - CLEANING AND CARE - 6AMICA MD 1014 - CLEANING AND CARE - 7
AMICA MD 1014 - CLEANING AND CARE - 8AMICA MD 1014 - CLEANING AND CARE - 9AMICA MD 1014 - CLEANING AND CARE - 10AMICA MD 1014 - CLEANING AND CARE - 11
AMICA MD 1014 - CLEANING AND CARE - 12AMICA MD 1014 - CLEANING AND CARE - 13AMICA MD 1014 - CLEANING AND CARE - 14AMICA MD 1014 - CLEANING AND CARE - 15

Manufacturer's Declaration

The manufacturer hereby declares that this product meets the requirements of the following European directives:

• Low Voltage Directive 2014/35/EC
• Electromagnetic Compatibility (EMC) Directive 2014/30/EC
• ErP Directive 2009/125/EC
• Directive RoHS 2011/65/EC

and has thus been marked with the symbol and been issued with a declaration of compliance made available to market regulators.

Amica S.A.

ul.Mickiewicza 52

64-510 Wronki

tel. 67 25 46 100

fax 67 25 40 320

www.amica.pl