CH 2000 TT - Heating EINHELL - Free user manual and instructions
Find the device manual for free CH 2000 TT EINHELL in PDF.
| Product type | Convector heater |
| Brand | Einhell |
| Model | CH 2000 TT |
| Rated voltage | 230 V ~ 50 Hz |
| Power output | 2000 W (750 W / 1250 W / 2000 W) |
| Heat settings | 3 (Low, Medium, Max) |
| Thermostat controller | Infinitely adjustable, includes anti-freeze setting |
| Timer (only CH 2000 TT) | 24-hour programmable, 15-minute segments |
| Fan (only CH 2000 TT) | Yes, with separate switch, works with or without heat |
| Dimensions (approx., without feet) | 59 x 12 x 37.5 cm |
| Weight (approx.) | 5.5 kg |
| Minimum distances | Side: 230 mm, Top: 450 mm |
| Assembly options | Freestanding (with feet) or wall-mounted |
| Protection class | I |
| Overheating guard | Automatic shut-off |
| Cleaning | Wipe with damp cloth, vacuum dust |
| Spare parts ordering | Provide model/type, article number, ID number, part number |
| Guarantee | 2 years (not for commercial use) |
Frequently Asked Questions - CH 2000 TT EINHELL
User questions about CH 2000 TT EINHELL
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Heating in PDF format for free! Find your manual CH 2000 TT - EINHELL and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. CH 2000 TT by EINHELL.
USER MANUAL CH 2000 TT EINHELL
2
4


Inhaltsverzeichnis
- Special safety instructions
- Layout
- Proper use
- Technical data
- Before starting the machine
- Operation
- Cleaning, maintenance and ordering of spare parts
- Storage
- Disposal and recycling
- Troubleshooting

Caution:
When using the equipment, a few safety precautions must be observed to avoid injuries and damage.
Please read the complete operating instructions and safety regulations with due care. Keep this manual in a safe place, so that the information is available at all times. If you give the equipment to any other person, hand over these operating instructions and safety regulations as well. We cannot accept any liability for damage or accidents which arise due to a failure to follow these instructions and the safety instructions.
1. Special safety instructions
- Read the operating instructions before using the equipment for the first time. The equipment may only be used as described therein. All other usages are not permitted.
- Keep the instructions in a safe place and give them to third parties if necessary.
- Check that the equipment has been delivered in perfect condition. If it has suffered any damage, do not connect the equipment to the power supply.
- Check the equipment, particularly the mains lead, for signs of damage every time before use. If you find signs of damage, contact ISC GmbH.
●Not suitable for commercial purposes.
●Use the equipment in enclosed, dry areas only.
●Never open the equipment or touch live parts – danger of death!
●Never use the equipment in the vicinity of wash basins, water connections, swimming pools or in the bathroom!
●Never immerse the equipment in water – danger of death! - Do not place the equipment near wet rooms or wet areas (bath, shower, swimming pool etc.) The heater should be installed so that switches and other controllers could not be touched by someone in the bath or shower.
●Never use the equipment with wet hands. - Do not cover the equipment – fire risk! (Fig. 4)
- Position the equipment in such a way that the mains plug is accessible at all times.
- If the equipment is not used for a lengthy period of time, disconnect it from the mains supply.
- Do not position the equipment directly below a socket.
- If the equipment is used for a lengthy time the housing can become very hot. Position the appliance in such a way as to prevent accidental contact.
●Never position the equipment on deep pile
carpets.
- Do not use the equipment in rooms in which inflammable materials (for example solvents, etc.) or gases are used or stored.
- Keep highly inflammable substances and gases away from the equipment.
- Do not use in areas where there is a fire risk (for example wooden sheds).
●Only use the heater with its mains lead fully extended.
●Not suitable for installation on permanently installed electrical cables. - Do not use the equipment for animal husbandry or livestock breeding.
- Do not insert any foreign objects in the equipment's openings – danger of electric shock and damage to the equipment.
- Keep children and people on medication or under the influence of alcohol away from the equipment.
●Maintenance and repair work may only be carried out by authorized trained personnel. - For electrical safety purposes we recommend that you install a residual current device circuit-breaker.
This appliance has not been designed for use by people (including children) with limited physical, sensory or mental capacities or those with no experience and/or knowledge unless they are supervised by a person who is responsible for their safety or they have received instructions from such a person in how to use the appliance safely. Children must always be supervised in order to ensure that they do not play with the equipment.

CAUTION
Read all safety regulations and instructions. Any errors made in following the safety regulations and instructions may result in an electric shock, fire and/or serious injury.
Keep all safety regulations and instructions in a safe place for future use.
2. Layout (Fig. 1)
- Feet
- Time switch (only CH 2000 TT)
- Thermostat controller
- Ventilator air outlet (only CH 2000 TT)
- Ventilator switch (only CH 2000 TT)
- Heat setting switch 1
- Heat setting switch 2
- Installation material
GB
3. Proper use
The appliance is only for use as living space heating in dry rooms.
The equipment may only be used for the tasks it is designed to handle. Any other use is deemed to be a case of misuse. The user/operator and not the manufacturer will be liable for any damage or injuries caused as a result thereof.
Please note that our equipment has not been designed for use in commercial, trade or industrial applications. Our warranty will be voided if the equipment is used in commercial, trade or industrial businesses or for equivalent purposes.
4. Technical data:
Rated voltage: 230 V \~ 50 Hz
Output: 2000 W (750 W / 1250 W / 2000 W)
Thermostat controller: Infinitely adjustable
Protection class: I
Mains lead: 3 x 1 mm
Equipment dimensions without feet approx.:
59 x 12 x 37.5 cm
5. Before starting the machine
5.1 Assembly
The equipment can be used indoors in a free standing position or mounted on a wall. Maintain all minimum distances. The equipment may only be used when completely assembled and standing vertically.
a) Free standing installation (Fig. 2)
Ensure that a minimum distance of 230 mm to the sides and 450 mm to the top of the equipment are maintained. Observe section 1 "Safety regulations". Caution: To prevent damage when attaching the feet to the heater, place the heater upside down on a soft surface (e.g. a carpet).
When attaching the feet, make sure that they are positioned on the correct sides of the equipment (notch facing inwards) and are fastened with 2 screws (A).
b) Wall mounting (Fig. 3)
Caution: Make sure that there are no electric cables or other installations (for example water pipes) near the drill holes. Ensure that the equipment is secured firmly and horizontally to the wall. Use only suitable fastening material on a suitably stable wall. The supplied dowels and screws are suitable for the following: Concrete, natural stone with a dense structure, solid brick, solid limestone bricks, solid lightweight concrete bricks and aerated concrete.
Ensure that a minimum distance of 230 mm to the sides and 450 mm to the top of the equipment are maintained. See section 1 "Safety regulations".
- Do not attach the feet if the equipment is to be mounted on the wall.
- When selecting the location for the appliance, please note that if there are skirtings on the floor, the minimum distance to the housing, or the installation height, has to be measured from the top of the skirting.
- Then drill the two fastening holes with 8 mm diameter. The centres of the holes must be marked so that they are 415 mm apart and horizontal (3) and at least 550 mm above the floor (allow for skirtings) and the holes must be drilled accordingly.
●Screw both shorter fixing brackets to the wall.
●Instead of the feet, attach both of the remaining longer fixing brackets with the shortest screws to the underside of the convector heater. These serve as separators for the wall.
●Hang the convector heater on the wall and hang the fixing brackets in the slots.
Note: The two bottom fixing brackets can also be fastened to the wall. To do so, hang the convector heater on the wall and drill holes in the wall to correspond to the holes in the bottom fixing brackets.
6. Operation
Caution: Before using the equipment for the first time, check that the voltage supply is the same as the voltage details set out on the rating plate.
Read the safety regulations in section 1.
When the equipment is used for the first time or after a long period of rest it may emit an odour for a short time. This is not a fault.
6.1 Heat output switches (Fig. 1):
●Low heat output – activate switch (Item 6)
●Medium heat output – activate switch (Item 7)
●Maximum heat output – activate switch (Item 6) and (Item 7)
6.2 Thermostat controller/Room temperature regulator (Fig. 1/Item 3):
Switch on the required heat output using the two function switches. Turn the control to "MAX" until the required room temperature has been reached. Then turn down the control until you hear a clear click. The thermostat control will switch the radiator on and off automatically to maintain the room temperature at an almost constant level. However, this presupposes that the radiator has sufficient output to cover the heating requirements for the room.
Note: "MIN" setting = antifreeze setting
6.3 Ventilator switch (only CH 2000 TT) (Fig. 1/Item 5)
●Switch ventilator ON/OFF (Fig. 1/Item 4)
Note: The ventilator only works if the thermostat controller is switched on, i.e. the temperature set on the thermostat controller is higher than the actual room temperature. The ventilator can be used with heat output (heating fan) or without heat output (cooling fan). Objects must be kept at a distance of at least 1 metre from the air outlet.
6.4 Time switch (only CH 2000 TT) (Fig. 1/Item 2) The time switch only runs as long as the convector is connected to the mains. The convector is switched on using the switch integrated in the time switch. The switch positions have the following meanings: Position "0" = OFF position.
Position "I" = Convector can only be switched ON or OFF manually. Position "Clock Symbol" = Automatic operation: Convector is switched ON or OFF automatically.
Several heating phases can be programmed with the time switch. For automatic operation, the correct time of day can be set by turning the scale in a clockwise direction. The arrow on the time switch shows the time set. The time at which the appliance switches off can be set by pulling out the segments and the time at which it switches on can be set by pushing the segments in. Every segment represents 15 minutes. The set programme repeats every 24 hours.
Note: Positions "0" and "1" override the set programme.
6.5 Overheating guard
In case of excessive heating, the equipment shuts down automatically. If this occurs, turn off the equipment, disconnect the mains plug and wait a few minutes for the appliance to cool. After eliminating the cause (e.g. a covered air grille), the equipment can be switched on again. If the overheating guard triggers repeatedly, please contact ISC GmbH.
7. Cleaning, maintenance and ordering of spare parts
7.1 Cleaning
●Before carrying out any cleaning and maintenance work the equipment must be turned off, disconnected from the power supply and cooled down.
●Maintenance and repair work may only be carried out by an authorized electrical servicing contractor or ISC GmbH.
- Check the mains lead at regular intervals for signs of defects or damage. A damaged mains lead may only be replaced by an electrician or ISC GmbH in compliance with the relevant regulations.
- Use a slightly damp cloth to clean the casing. Remove dust pollution with a vacuum cleaner.
7.2 Maintenance
There are no parts inside the equipment which require additional maintenance.
7.3 Ordering replacement parts
Please provide the following information on all orders for spare parts:
●Model/type of the equipment
●Article number of the equipment
●ID number of the equipment
●Part number of the required spare part
For our latest prices and information please go to www.isc-gmbh.info.
8. Storage
The heater has to be stored in a dry place, covered if possible.
9. Disposal and recycling
The device is supplied in packaging to prevent its being damaged in transit. This packaging is raw material and can therefore be reused or can be returned to the raw material system. The appliance and its accessories are made of various types of material, such as metal and plastic. Defective components must be disposed of as special waste. Ask your dealer or your local council.
GB
10. Troubleshooting
If the equipment is operated properly you should experience no problems with malfunctions or faults. In the event of any malfunctions or faults, please check the following before you contact your customer services.
| Fault | Possible cause | Remedy |
| Appliance does not heat up Mains pl | plug not inserted into the socket | Insert the plug into the socket |
| Appliance does not heat up The ther | mostat controller is set too low | Turn the thermostat controller to the right to raise the temperature |
| Appliance does not heat up Overhe | ating guard has been triggered | See paragraph 6.5 |
| Ventilator does not work (only CH-2000 TT) | Ventilator switch is switched OFF Switch on the ventilator switch | |
Indice
natural_image
Symbol of a trash bin crossed out by two diagonal lines (no text or labels)
©Nur für EU-Länder
For EU countries only
Never place any electric tools in your household refuse.
To comply with European Directive 2002/96/EC concerning old electric and electronic equipment and its implementation in national laws, old electric tools have to be separated from other waste and disposed of in an environment-friendly fashion, e.g. by taking to a recycling depot.
Recycling alternative to the demand to return electrical devices:
As an alternative to returning the electrical device, the owner is obliged to cooperate in ensuring that the device is properly recycled if ownership is relinquished. This can also be done by handing over the used device to a returns center, which will dispose of it in accordance with national commercial and industrial waste management legislation. This does not apply to the accessories and auxiliary equipment without any electrical components which are included with the used device.
The reprinting or reproduction by any other means, in whole or in part, of documentation and papers accompanying products is permitted only with the express consent of ISC GmbH.
①
All of our products undergo strict quality checks to ensure that they reach you in perfect condition. In the unlikely event that your device develops a fault, please contact our service department at the address shown on this guarantee card. Of course, if you would prefer to call us then we are also happy to offer our assistance under the service number printed below. Please note the following terms under which guarantee claims can be made:
- These guarantee terms cover additional guarantee rights and do not affect your statutory warranty rights. We do not charge you for this guarantee.
- Our guarantee only covers problems caused by material or manufacturing defects, and it is restricted to the rectification of these defects or replacement of the device. Please note that our devices have not been designed for use in commercial, trade or industrial applications. Consequently, the guarantee is invalidated if the equipment is used in commercial, trade or industrial applications or for other equivalent activities. The following are also excluded from our guarantee: compensation for transport damage, damage caused by failure to comply with the installation/assembly instructions or damage caused by unprofessional installation, failure to comply with the operating instructions (e.g. connection to the wrong mains voltage or current type), misuse or inappropriate use (such as overloading of the device or use of non-approved tools or accessories), failure to comply with the maintenance and safety regulations, ingress of foreign bodies into the device (e.g. sand, stones or dust), effects of force or external influences (e.g. damage caused by the device being dropped) and normal wear resulting from proper operation of the device. This applies in particular to rechargeable batteries for which we nevertheless issue a guarantee period of 12 months.
The guarantee is rendered null and void if any attempt is made to tamper with the device.
-
The guarantee is valid for a period of 2 years starting from the purchase date of the device. Guarantee claims should be submitted before the end of the guarantee period within two weeks of the defect being noticed. No guarantee claims will be accepted after the end of the guarantee period. The original guarantee period remains applicable to the device even if repairs are carried out or parts are replaced. In such cases, the work performed or parts fitted will not result in an extension of the guarantee period, and no new guarantee will become active for the work performed or parts fitted. This also applies when an on-site service is used.
-
In order to assert your guarantee claim, please send your defective device postage-free to the address shown below. Please enclose either the original or a copy of your sales receipt or another dated proof of purchase. Please keep your sales receipt in a safe place, as it is your proof of purchase. It would help us if you could describe the nature of the problem in as much detail as possible. If the defect is covered by our guarantee then your device will either be repaired immediately and returned to you, or we will send you a new device.
Of course, we are also happy offer a chargeable repair service for any defects which are not covered by the scope of this guarantee or for units which are no longer covered. To take advantage of this service, please send the device to our service address.