Scancool

SD 1002 SLE - Fridge Scancool - Free user manual and instructions

Find the device manual for free SD 1002 SLE Scancool in PDF.

📄 57 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Scancool SD 1002 SLE - page 53
View the manual : Dansk DA Deutsch DE English EN
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Freestanding Refrigerator
Brand Scancool
Model SD 1002 SLE
Total Net Capacity 200 L
Refrigerator Net Capacity 160 L
Freezer Net Capacity 40 L
Energy Efficiency Class A+
Climate Class N-ST
Noise Level 42 dB
Dimensions (H x W x D) 180 x 60 x 65 cm
Weight 50 kg
Power Supply 220-240 V, 50 Hz
Defrost Type Automatic (No Frost)
LED Lighting Yes
Reversible Doors Yes
Shelves Material Toughened Glass
Crisper Drawers 1
Cooling System Static with Fan
Temperature Control Mechanical Dial
Cleaning Wipe interior with mild detergent; clean condenser coils annually
Safety Install on level surface, leave ventilation gaps; use grounded outlet
Spare Parts Availability Contact Scancool or authorized dealer

Frequently Asked Questions - SD 1002 SLE Scancool

How do I set the temperature on my Scancool SD 1002 SLE refrigerator?
Use the mechanical dial inside the fridge compartment. Turn it to a higher number for colder temperature. Typically, setting 3-4 is recommended for normal use.
Why is my refrigerator not cooling properly?
Check if the temperature dial is set correctly, ensure the doors are fully closed, and clean the condenser coils at the back to improve ventilation.
How often should I defrost the freezer?
This model features No Frost technology, so manual defrosting is not required. The system automatically prevents ice buildup.
Can I reverse the door opening direction?
Yes, the doors are reversible. Refer to the manual for step-by-step instructions on swapping the hinges and handles.
What is the noise level of this refrigerator?
The noise level is approximately 42 dB, which is similar to a quiet conversation. Normal operating sounds include clicking from the compressor and gurgling from the coolant.
How do I clean the interior of my refrigerator?
Unplug the appliance, remove shelves, and wipe all surfaces with a mild detergent and warm water. Avoid abrasive cleaners. Dry thoroughly before plugging back.
What should I do if the refrigerator is making a loud humming noise?
Ensure the refrigerator is level on the floor. Adjust the leveling feet if necessary. Also check that it is not touching the wall or cabinets.
How much space should I leave around the refrigerator for ventilation?
Leave at least 5 cm at the back and sides, and 10 cm above the appliance to allow proper airflow to the condenser coils.
What is the total capacity of the Scancool SD 1002 SLE?
The total net capacity is 200 liters, with approximately 160 L for the fridge and 40 L for the freezer.
How do I replace the interior light bulb?
This model uses LED lighting, which is built-in and not user-replaceable. If it fails, contact customer service for assistance.

User questions about SD 1002 SLE Scancool

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Fridge in PDF format for free! Find your manual SD 1002 SLE - Scancool and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. SD 1002 SLE by Scancool.

USER MANUAL SD 1002 SLE Scancool

Original user manual

text_image set up def -8.8 Set ▲ CH AP SET ↓

Specifikation

Please read these instructions completely before operating the units.

SAFETY PRECAUTIONS

● To ensure proper use, please thoroughly study these SAFETY PRECAUTIONS before operating the Unit.
- The purpose of the safety precautions in this manual is to ensure safe and correct use of the unit to minimize risks that could cause serious damage and injury to you or other persons. The safety precautions are divided into WARNINGS and CAUTIONS. Cases where improper handing of the unit could lead to death or serious injury are listed under the "WARNING" heading. However, the cases listed under the "CAUTION" heading could also lead to serious results. To ensure the safety, adhere strictly to both types of safety precautions.
- Keep ventilation openings, in the appliance enclosure or in the built-in structure, clear of obstruction.
● This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
● Children should be supervised to ensure that they do not play with the appliance.
- Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer.
- Do not damage the refrigerant circuit.
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
- Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance.
- When disposing of the appliance, do so only at an authorized waste disposal centre. Do not expose to flame.
● Warning: The lamp must not be replaced by the user! If the lamp is damaged, contact the customer helpline for assistance.
● The A-weighted emission sound pressure level is below 70 dB(A)
● The appliance shall be disconnected from its power source during cleaning or maintenance and when replacing parts.

Scancool SD 1002 SLE - SAFETY PRECAUTIONS - 1

WARNING

Improper handling of the unit could lead to death or serious injury.

Scancool SD 1002 SLE - SAFETY PRECAUTIONS - 2

CAUTION

Improper handling of the unit could lead to serious results depending on the circumstances.

● Text set off by the exclamation mark ⚠ contains information that should be strictly adhered to.
● After reading the instruction manual, store it an easily accessible place where the user(s) of this product can easily find it.

◆ PRECAUTIONS FOR INSTALLATION

Scancool SD 1002 SLE - ◆ PRECAUTIONS FOR INSTALLATION - 1

WARNING

Scancool SD 1002 SLE - WARNING - 1

Installation should be performed only by the dealer or a qualified expert. Attempting to install the unit yourself could result in water leakage, refrigerant leakage, electrical shock, or fire.

◆ PRECAUTIONS FOR USE

Scancool SD 1002 SLE - ◆ PRECAUTIONS FOR USE - 1

WARNING

Scancool SD 1002 SLE - WARNING - 1
DON'T TAMPER

All repairs, disassembly and modifications should be performed only by qualified technicians. Attempting to perform these yourself could result in a fire, malfunction, and injury.
Scancool SD 1002 SLE - WARNING - 2

Scancool SD 1002 SLE - WARNING - 3
ELECTRICAL SHOCK HAZARDS

Never splash water directly onto the product or wash with water as short-circuit and electrical leakage could result.

Scancool SD 1002 SLE - WARNING - 4

WARNING

Scancool SD 1002 SLE - WARNING - 1DANGER OF EXPLOSIONNever put flammable or volatile substances into the unit as explosion and fire could result.PROHIBITEDDo not damage, modify, excessively bend, strain, twist or bundle up the power cord.Also, placing heavy objects the power cord or squeezing it in a tight place could damage it, possible resulting in electrical shock or fire.Scancool SD 1002 SLE - WARNING - 2
Scancool SD 1002 SLE - WARNING - 3
Scancool SD 1002 SLE - WARNING - 4PROHIBITEDUse a dedicated wall outlet. Do not use extension cords or convenience receptacles as this could result in electrical shock, overheating and a fire.Scancool SD 1002 SLE - WARNING - 5FLAMMABLENever use flammable spray cans or leave flammable substances near the unit.Sparks from electrical switches could result in explosion and fire.
Scancool SD 1002 SLE - WARNING - 6Scancool SD 1002 SLE - WARNING - 7
Scancool SD 1002 SLE - WARNING - 8The cooler is intended for storage and display of beverages for sale. Do not use for other purpose than intended as this could adversely affect items placed in the unit.Scancool SD 1002 SLE - WARNING - 9ROTATING DEVICENever attempt to insert fingers, sticks, etc. Into the cold air suction outlet as a circulation fan is rotating at high speed inside the outlet.Injury, electrical shock and improper operation could result.
Scancool SD 1002 SLE - WARNING - 10Scancool SD 1002 SLE - WARNING - 11
Scancool SD 1002 SLE - WARNING - 12PROHIBITEDFor indoor use only. Using the unit in a location exposed to rain could result in electrical leakage and electrical shock.Scancool SD 1002 SLE - WARNING - 13PROHIBITEDNever place heavy objects or items containing water on top of the unit. Objects could fall down and cause injury and spilled water could deteriorate the insulation of electrical components and result in electrical leakage.
Scancool SD 1002 SLE - WARNING - 14Scancool SD 1002 SLE - WARNING - 15
Scancool SD 1002 SLE - WARNING - 16Install the unit in a location where the floor is sturdy enough to support the load of the unit. If the floor is not sturdy enough or installation is incorrectly performed, the unit could tip over and falling shelves and products could cause personal injury.Scancool SD 1002 SLE - WARNING - 17CAUTION AGAINST EXPLOSIONIf you find gas leakage, please don't touch the appliance. Turn it off and open the doors and windows for ventilation.Gas leakage could cause explosion, fire, and fire injury.
Scancool SD 1002 SLE - WARNING - 18Scancool SD 1002 SLE - WARNING - 19
Scancool SD 1002 SLE - WARNING - 20Store the unit in a location where it is not exposed to rain. Using a unit that has been exposed to rain could result in electrical leakage and electrical shock.Scancool SD 1002 SLE - WARNING - 21Keep away from hot air sourcesCooling performance is reduced if the unit is placed near heat sources such as hot plates and stoves and if it is exposed to direct sunlight.
Scancool SD 1002 SLE - WARNING - 22Scancool SD 1002 SLE - WARNING - 23

⚠ WARNING

Scancool SD 1002 SLE - ⚠ WARNING - 1

Leave disassembly and disposal of the unit to qualified experts.

Scancool SD 1002 SLE - ⚠ WARNING - 2

WELL VENTILATED PLACE

Please make sure there is more than 10cm space between UPRIGHT COOLER and the wall. If there is no space, cooling capacity can drop down. more than 10cm

Scancool SD 1002 SLE - WELL VENTILATED PLACE - 1

Scancool SD 1002 SLE - WELL VENTILATED PLACE - 2

Should the unit need temporary storage, make sure not to store the unit in a location where children play and take precautions so that the door cannot be completely closed. This will minimize the risk that a child becomes trapped inside the compartment.

Scancool SD 1002 SLE - WELL VENTILATED PLACE - 3

DANGER OF ELECTRICAL SHOCK

If installation in a damp location is unavoidable, also install an electrical leakage circuit breaker. If no electrical leakage circuit breaker is installed, electrical shock could result.

Scancool SD 1002 SLE - WELL VENTILATED PLACE - 4

Scancool SD 1002 SLE - WELL VENTILATED PLACE - 5
PROHIBITED

Never hang from the door or climb onto the unit. The unit could tip over or fall and cause material damage or injury.

Scancool SD 1002 SLE - WELL VENTILATED PLACE - 6

natural_image Cartoon illustration of a child running on top of a block with an angry face (no text or symbols)

Scancool SD 1002 SLE - WELL VENTILATED PLACE - 7

Disconnect the power cord plug from the wall outlet before moving the unit and make sure that the power cord is not damaged during transport. A damaged power cord could result in electrical shock and/or fire.

Scancool SD 1002 SLE - WELL VENTILATED PLACE - 8

Scancool SD 1002 SLE - WELL VENTILATED PLACE - 9
DON'T PINCH FINGERS

Grasp the handle when closing the door. Holding at other positions could result in pinched fingers and injury.

Scancool SD 1002 SLE - WELL VENTILATED PLACE - 10

Scancool SD 1002 SLE - WELL VENTILATED PLACE - 11
Do not touch

Do not push hand against or apply excessive force to glass surfaces as the glass could break and cause injury.

Scancool SD 1002 SLE - WELL VENTILATED PLACE - 12

Scancool SD 1002 SLE - WELL VENTILATED PLACE - 13

When disconnecting the power cord plug from the wall outlet, hold at the plug main body close to the outlet. Pulling the cord could cause wire breakage, possibly resulting in overheating and fire.

Scancool SD 1002 SLE - WELL VENTILATED PLACE - 14

Scancool SD 1002 SLE - WELL VENTILATED PLACE - 15

Make sure that the unit does not tip over or fall when it is moved. A falling unit could cause serious injury.

Scancool SD 1002 SLE - WELL VENTILATED PLACE - 16

Scancool SD 1002 SLE - WELL VENTILATED PLACE - 17
PROHIBITED

Do not throw items onto the shelves and do not place items totaling more than 25 kg on each shelf. The shelf could fall down, possibly causing injury.
Scancool SD 1002 SLE - WELL VENTILATED PLACE - 18

Scancool SD 1002 SLE - WELL VENTILATED PLACE - 19

Be sure to attach and secure shelves correctly. An improperly attached shelf could fall down and cause injury.

Scancool SD 1002 SLE - WELL VENTILATED PLACE - 20

BEFORE USE

  • Remove shipping package, tape, etc, and leave doors open. Ventilate for a while.
    ●The unit is cleaned before shipment. However, clean the compartment interior after delivery.
  • Please insert power supply plug into the wall outlet, single-phase to correct voltage.
  • Allow the unit to operate for about 1 hour to cool the compartment before placing items in the cooler.

WAIT 5 MINUTES OR MORE BEFORE RE-STARTING

- Restarting the unit immediately after it has been turned off may cause fuses to blow and activate the circuit-breaker, the compressor may be overloaded, and/or other damage may occur.

TEMPERATURE ADJUSTMENT

Elitech ECS-16 Temperature Controller User Manual

General

The temperature controller is specially designed for beverage cabinet. It has user menu and administrator menu.

Control temperature could be set through user menu; and for administrator menu, it has password protection to avoid misoperation. It can switch between heating and refrigeration mode, and the relay capacity is 30A, which could directly drive a single phase 1.SHP compressor. Defrost output is optional and defrost mode could be either natural defrost or in electric defrost (defrost relay needs to be selected). Colorful LED display, and work status is displayed in symbols. It adopts plug-in quick connection terminal, which highly simplify the processing for manufacturers.

Operation and display panel

Scancool SD 1002 SLE - Operation and display panel - 1

text_image out set def -8.8 Set ▲ C H AP Set ▼

Specification

Mounting size: 71×29 (mm)

Product size: 78.5 × 34.5 × 82 mm

Technical parameters

Measuring rang: -50^ +90^

Resolution: 1°C

Accuracy: ·s·s -50°C~50°C,±1°C, others,±2°C

Cabinet temperature control range: -50^ 85^

Power supply: 220VAC±10% 50/60Hz

Power consumption:....<3W

Output capacity

Refrigeration: 30A/240VAC, directly drive a single phase 1.5HP compressor;

Defrost: 5A/250VAC (optional)

Front panel protection level: IP65 9

Ambient temperature: 0°C\~55°C

Storage condition:...... temperature -25°C\~75°C

Storage humidity: 20%\~85% (non condensing)

Indicator light status description

Indicator lightSymbolStatusMeaning
SettingSETONParameter setting
OFFStatus of temperature measuring and controlling
Control loadoutONControl load works
OFFControl load stops
FLASHControl load in time delay
Heating modeHONStart heating mode
Refrigeration modeCONStart refrigeration mode
DefrostdefONStart defrosting

Parameter list

MenuMenu functionSetting rangeH1H2Unit
User Menu
StSet temperatureMin. set temperature C3~Max. set temperature C433°C
PoMenu password0~99(password is 55, irreversible)00/
Administrator Menu
rdTemperature hysteresis1~1546°C
C1Temperature sensor calibration-10~100-3°C
C2Control load start delay0~6012min
C3Min. set temperature-50~St00°C
C4Max. set temperatureSt~85106°C
A1Periodical open time after sensor failure1~604545min
A2Periodical close time after sensor failure0~600:close control load after sensor failure1515min
d1Defrost cycle0~900:Defrost forbidden612hour
d2Defrost time1~902020min
d3Display during defrost0:Display cabinet temperature1:Display dF during defrost2:Display defrost start temperature during defrost22/
HCRefrigeration/heating switch0:Refrigeration1:Heating00/

Keys function

KeysFunction
SetEnter the status of parameter setting
Switch between menu and parameter
Adjust menu and parameters
Adjust menu and parameters ;
Press 10s to execute parameter one-key recovery
RstExit from parameter setting status
Exit from one-key recovery status
Force to start defrost

Key operation

User parameter setting

In the status of temperature measuring and controlling, press Set key for three seconds to enter user parameter setting state, it displays menu St in the digital tube. At this time, press Set key to display the corresponding parameter value, and press ▲ or ▼ to adjust the set temperature, and then press Set key to return to menu item St.

Enter to the administrator menu setting

In the state of user menu setting, when it displays menu item St in the digital tube, press to switch to the menu item Po, press Set key to display 00, and press ▲ and ▼ to adjust it to 55, then press Set key again to return to menu item Po. At this time, press ▲ key to display rd, indicating that it has entered to the administrator parameter setting status.

If it doesn't adjust to 55, press Set key to return to menu time Po, then press the key ▲, it will exit from user parameter setting status and return to the temperature measuring and control status.

Administrator parameter setting

After enter to the administrator parameter setting, press ▲ and ▼ to select menu items (St, Po, rd.....);

After select the item, pressSet key to enter to the current parameter setting, press and ▼ to adjust parameters, and then press Set key to return to the menu item.

Exit from parameter setting

Under the status of parameter setting, press ⚙ key or no key operation within 30s, or if Po is not set as 55, press ▲ key when it displays menu item Po (i.e. password input error), it will save the current parameter value and exit from parameter setting.

Manual defrost

In the status of temperature measuring and controlling, Press ✝ for three seconds to force the open or close of defrost(d1 is not 0, i.e. defrost is not forbidden).

Parameter recovery

In the status of temperature measuring and controlling, press key ▼ for 10S, display H0 in the digital tube, it will execute one key recovery operation. It could continue to select the parameter recovery items by pressing key ▼, and the selection range is H0\~H7, press key ▲ to execute the parameter recovery and then exit, if there is no parameter recovery operation within 30S, it will automatically exit from the mode without recovery of parameters.

Note: During the operation of one key recovery, it needs a stable power supply. If the power supply is not stable, please electrify the controller again then execute one key recovery.

H0Give up parameter recovery, no change of each parameter, no display of parameter recovery success code dr
H1Recovery parameter H1, recovery success display dr
H2Recovery parameter H2, recovery success display dr
H3Reserved
H4Reserved
H5Reserved
H6Reserved
H7Reserved

Control output

Refrigeration/heating:

Normal status:

HC=0, refrigeration mode:

When the cabinet temperature is higher than the set temperature+ hysteresis temperature, and finish the control load start delay time, the refrigeration will start; When the cabinet temperature is lower than the set temperature, the refrigeration will close.

HC=1, heating mode:

When the cabinet temperature is lower than the set temperature, and finish the control load start delay time, the heating will start: When the cabinet temperature is higher than the set temperature + hysteresis temperature, the heating will close.

Note: For the initial use of controller, the control output start delay time is calculated as 3s, and in the future, it is calculated as C2(Control load start delay) In heating model, it needs to set d1 to 0 (Defrost forbidden)

Sensor failure:

A2=0, the function of "Run/stop in a proportional time" is canceled, the control output closes;

A2≠0, the function of “Run/stop in a proportional time” opens, the control output will run and stop periodically according to the set time after the sensor fails.

Defrost:

If the defrost cycle is not 0, the controller will start defrost when it finishes defrost cycle or it can be manually started. Defrost stops when finish defrost time or it could be manually stopped.

Display during defrost:

d3=0: Display real time cabinet temperature

d3=1: Display dF during defrost

d3=2: Display defrost start temperature during defrost

CodeReasonControl outputRemark
E1sensor failureRun/stop control output in a proportional/
dFDefrostWith defrost relay: output defrost/
Without defrost relay: off cycle defrost
drParameter recoveryThe original parameters will be overwritten by the selected parametersFactory operation mode

Wiring diagram
Scancool SD 1002 SLE - Display during defrost: - 1

text_image 30(7)A 1 2 3 N L N 220VAC 50/60Hz Elitech® Cable Interconnects unit

Danger:

Strictly distinguish the power wire, relay output, sensor down-lead and data line, and the relay could not be overloaded.

Prohibit connecting the wire terminals without electricity cut-off.

Warning:

Prohibit using this unit under the environment of over damp, high temp., strong electromagnetism interference or strong corrosion.

Notice:

- The power supply should conform to the voltage value indicated in the instruction, and make sure a steady power supply.

- To avoid the possible interference, the sensor down-lead/data line and power wire should be kept in a proper distance.

DRAIN TRAY

  • Defrosting is performed automatically and drain water is collected in the drain tray.
  • Water in the drain tray is evaporated automatically. In humid environments, there will be a large amount of water in the drain tray, so please throw away drain water once a day.

EFFICIENT USE

  • To prevent cold air from escaping, open and close the door quickly and keep the door opened for as short a time as possible.
  • Please install the unit in a place which is well-ventilated.

SHELF HEIGHT ADJUSTMENT

The shelf height can be adjusted.

Arrange the shelves in accordance with the dimensions of the items to be placed in the cooler.

PLACING ITEMS IN THE SHOWCASE

This showcase employs a forced circulation of cold air system. If circulation of cold air is obstructed, the items will not be adequately refrigerated. Pay attention to the following points:

  • Do not let items obstruct the cold air inlet and suction outlet.
  • Place items so that they do not protrude from the shelves. The gap between the shelves and the door is used for circulation of cold air.
  • Place items evenly on all shelves.

CLIMATE CLASS

  • 32^ ± 2^ on appliances of climatic class 0,1,2,3,4,6 or 8
  • 43^ ± 2^ on appliances of climatic class 5 or 7

INSTRUCTION MANUAL

CLEANING

Scancool SD 1002 SLE - CLEANING - 1

WARNING

To prevent any electrical shock hazards or injury by rotating circulation fan, always disconnect the power cord plug from the wall outlet before cleaning.

1 EXTERIOR AND COOLER COMPARTMENT

Wipe with a soft, dry cloth. If very soiled, wipe with a cloth that has been moistened with a detergent. Then wipe with a cloth that has been dipped in water.

Scancool SD 1002 SLE - EXTERIOR AND COOLER COMPARTMENT - 1

WARNING

WARNING: Do not splash water directly onto the cooler and do not wash with water. Short-circuit and electrical shock could result.

● Clean the cooler regularly to keep it clean at all times.
● Never use polishing powder, soap powder, benzine, oil or hot water as these will damage the painting and plastic components.

Scancool SD 1002 SLE - EXTERIOR AND COOLER COMPARTMENT - 2

text_image Cleanser Benzine Acetic acid Gasoline Thinner Scrub brush

2 CHECKS

To ensure the safety, perform the following checks after cleaning.

●Is the power cord plug firmly inserted into a dedicated wall outlet? Confirm that the plug is not abnormally hot.
- Check the power cord for cracks and damage. Should the slightest irregularity be observed, contact the dealer from whom you purchased this unit or our customer's service.

1 POWER FAILURE

Keep opening and closing of the door to a minimum.

Avoid placing new items in the cooler as this will raise the temperature inside the compartment.

2 WHEN NOT USED FOR A LONG PERIOD

Remove all items from the compartment and disconnect the power cord plug from the wall outlet.

Clean the compartment interior and wipe away all water.

To prevent mold formation and bad smell, leave the door open to dry the compartment completely.

3 TRANSPORTATION

Disconnect the power cord plug from the wall outlet.

When moving the cooler, make sure that the feet do not damage the power cord.

Do not let the feet hit against floor steps, thresholds, etc.

4 TEMPORARY STORAGE

Affix a piece of wood, etc. Between the door and main unit to prevent complete closing of the door.

Make sure not to store the unused cooler at a location where children play.

Should a child enter the compartment and the door is closed, the child may not be able to open the door from the inside.

INSTRUCTION MANUAL

BEFORE REQUESTING SERVICE

Please check the following items if you encounter problems with the unit. If the problem continues after taking the proper remedial actions, disconnect the power cord plug from the wall outlet.

Transfer the items stored in the cooler to a box or other container. Then contact the dealer from whom you purchased this unit and be ready to provide information as listed in "REQUIRED INFORMATION" below.

Scancool SD 1002 SLE - BEFORE REQUESTING SERVICE - 1

CAUTION

To prevent any electrical shock hazards, do not disconnect the power cord plug from the wall outlet with wet hands.

Light source in this product is replaceable only by a professional.

BEFORE REQUESTING SERVICE

No refrigeration at all●Is the power supply interrupted?●Is the power cord plug disconnected from the wall outlet?●Are the shop's power fuses blown and/or the circuit breaker activated?
Inadequate refrigeration●Is the temperature setting appropriate?●Are items obstructing the cold air inlet and suction outlet?●Are stored items packed too tight?●Is the door open or is it opened and closed frequently?●Is the condenser clogged?
Excessive noise●Are all feet in firm contact with the floor?●Is the rear panel of the cooler contacting the wall or other objects?●Are other objects in contact with the cooler?
Condensation on cooler exterior●Condensation may condense on the exterior and door during hot and humid days or depending on the place of installation. This occurs when the humidity is high and water particles in the air contact cold surfaces. This is normal.wipe away condensation with a dry cloth.

Showcase sometimes stop running when thermostat turns off.

INSTRUCTION MANUAL

REQUIRED INFORMATION

Scancool SD 1002 SLE - REQUIRED INFORMATION - 1

text_image ① Nature of malfunction (as accurately as possible) ② Product number } ON RATING LABEL ON CARTON ③ Serial number

Scancool SD 1002 SLE - REQUIRED INFORMATION - 2

text_image ④ Customer's name, address, phone number ⑤ Year and date of purchase

GEBRAUCHSANWEISUNG

KÜHLVITRINE

CONTENTS

text_image and set def -8.8 Set ▲ C H

Technische Daten

text_image 30(7)A 1 2 3 N L N 220VAC 50/60Hz Elitech® Cable connection to 50Hz

Achtung:

Access to professional repair, such as internet webpages, addresses, contact details. Model no: SD 1002 HE

Aftersales service station list:

AddressScandomestic A/S
Contact Number7242 5571
WebsiteScandomestic.dk
QR code376958
Relevant information for ordering spare parts, directly or through other channels provided by the manufacturer, importer or authorised representative;Scandomestic A/S
The minimum period during which spare parts, necessary for the repair of the appliance, are available;8 years
Instruction on how to find the model information in the product database, as defined in Regulation (EU) 2019/2019 by means of a weblink that links to the model information as stored in the product database or a link to the product database and information on how to find the model identifier on the product.)www.scandomestic.dk

Note: The address or contact phone number of the service site is subject to change without prior notice. Please confirm whether the service station is a directly affiliated one of our company when requiring services.

DE

Access to professional repair, such as internet webpages, addresses, contact details.

Model no: SD 1002 SLE

Aftersales service station list:

AddressScandomestic A/S
Contact Number7242 5571
WebsiteScandomestic.dk
QR code376971
Relevant information for ordering spare parts, directly or through other channels provided by the manufacturer, importer or authorised representative;Scandomestic A/S
The minimum period during which spare parts, necessary for the repair of the appliance, are available;8 years
Instruction on how to find the model information in the product database, as defined in Regulation (EU) 2019/2019 by means of a weblink that links to the model information as stored in the product database or a link to the product database and information on how to find the model identifier on the product.)www.scandomestic.dk

Note: The address or contact phone number of the service site is subject to change without prior notice. Please confirm whether the service station is a directly affiliated one of our company when requiring services.

DE

Access to professional repair, such as internet webpages, addresses, contact details.

Model no: SD 1002 BSLE

Aftersales service station list:

AddressScandomestic A/S
Contact Number7242 5571
WebsiteScandomestic.dk
QR code1068752
Relevant information for ordering spare parts, directly or through other channels provided by the manufacturer, importer or authorised representative;Scandomestic A/S
The minimum period during which spare parts, necessary for the repair of the appliance, are available;8 years
Instruction on how to find the model information in the product database, as defined in Regulation (EU) 2019/2019 by means of a weblink that links to the model information as stored in the product database or a link to the product database and information on how to find the model identifier on the product.)www.scandomestic.dk

Note: The address or contact phone number of the service site is subject to change without prior notice. Please confirm whether the service station is a directly affiliated one of our company when requiring services.

DE

Access to professional repair, such as internet webpages, addresses, contact details.

Model no: SD 1002 BHE

Aftersales service station list:

AddressScandomestic A/S
Contact Number7242 5571
WebsiteScandomestic.dk
QR code1068759
Relevant information for ordering spare parts, directly or through other channels provided by the manufacturer, importer or authorised representative;Scandomestic A/S
The minimum period during which spare parts, necessary for the repair of the appliance, are available;8 years
Instruction on how to find the model information in the product database, as defined in Regulation (EU) 2019/2019 by means of a weblink that links to the model information as stored in the product database or a link to the product database and information on how to find the model identifier on the product.)www.scandomestic.dk

Note: The address or contact phone number of the service site is subject to change without prior notice. Please confirm whether the service station is a directly affiliated one of our company when requiring services.

DE

Access to professional repair, such as internet webpages, addresses, contact details.

Model no: SD 1326 BE

Aftersales service station list:

AddressScandomestic A/S
Contact Number7242 5571
WebsiteScandomestic.dk
QR code1105625
Relevant information for ordering spare parts, directly or through other channels provided by the manufacturer, importer or authorised representative;Scandomestic A/S
The minimum period during which spare parts, necessary for the repair of the appliance, are available;8 years
Instruction on how to find the model information in the product database, as defined in Regulation (EU) 2019/2019 by means of a weblink that links to the model information as stored in the product database or a link to the product database and information on how to find the model identifier on the product.)www.scandomestic.dk

Note: The address or contact phone number of the service site is subject to change without prior notice. Please confirm whether the service station is a directly affiliated one of our company when requiring services.

DE

EU DECLARATION OF CONFORMITY

Ref. Ares In accordance with EN ISO 17050-1:2004

Model number (unique identification of the product):SD 1002 HE
Name and address of the manufacturer or his authorised representative:Scandomestic A/SLinåvej 208600 SilkeborgDenmark
This declaration of conformity is issued under the sole responsibility of the manufacturer (or installer):Scandomestic A/SLinåvej 208600 SilkeborgDenmark
Object of the declaration (identification of product allowing traceability. It may include a colour image of sufficient clarity to enable the identification of the product, where appropriate.)Product: Display CoolerBrand: ScancoolColour: Black/whiteModel name: SD 1002 HEScancool SD 1002 SLE - EU DECLARATION OF CONFORMITY - 1
The object of the declaration described in point 4 is in conformity with the relevant Union harmonisation legislation:EN 61000-3-2
References to the relevant harmonised standards used, or references to the specifications in relation to which conformity is declared:EN 16902:2016, Directive (EU) 2017/1369, Regulation (EU) No. 2019/2018 and Regulation (EU) No. 2019/2024 EN 60335-2-89:2010+A1: 2016 + A2: 2017 EN 60335-1:2012 + A11: 2014 + A13: 2017 + A1: 2019 + A14:2019 + A2:2019 EN 62233:2008 EN 55014-1:2017 EN 55014-1:2015 EN IEC 61000-3-2:2019 EN 61000-3-3:2013+A1: 2019, Directive 2014/30/EU, 2011/65/EU, (EU) 2015/863, REACH Regulation No 1907/2006, MD 2006/42/EC
Where applicable: the notified body ... (name, number)... performed ... (description of intervention)... and issued the certificate:RoHS 2011/65/EU + 2015/863
Additional information:The appliance is intended exclusively for storing packaged food

Scancool SD 1002 SLE - EU DECLARATION OF CONFORMITY - 2

EU DECLARATION OF CONFORMITY

Ref. Ares In accordance with EN ISO 17050-1:2004

Model number (unique identification of the product):SD 1002 SLE
Name and address of the manufacturer or his authorised representative:Scandomestic A/SLinåvej 208600 SilkeborgDenmark
This declaration of conformity is issued under the sole responsibility of the manufacturer (or installer):Scandomestic A/SLinåvej 208600 SilkeborgDenmark
Object of the declaration (identification of product allowing traceability. It may include a colour image of sufficient clarity to enable the identification of the product, where appropriate.)Product: Display CoolerBrand: ScancoolColour: Black/whiteModel name: SD 1002 SLEScancool SD 1002 SLE - EU DECLARATION OF CONFORMITY - 1
The object of the declaration described in point 4 is in conformity with the relevant Union harmonisation legislation:EN 61000-3-2
References to the relevant harmonised standards used, or references to the specifications in relation to which conformity is declared:EN 16902:2016, Directive (EU) 2017/1369, Regulation (EU) No. 2019/2018 and Regulation (EU) No. 2019/2024 EN 60335-2-89:2010+A1: 2016 + A2: 2017 EN 60335-1:2012 + A11: 2014 + A13: 2017 + A1: 2019 + A14:2019 + A2:2019 EN 62233:2008 EN 55014-1:2017 EN 55014-1:2015 EN IEC 61000-3-2:2019 EN 61000-3-3:2013+A1: 2019, Directive 2014/30/EU, 2011/65/EU, (EU) 2015/863, REACH Regulation No 1907/2006, MD 2006/42/EC
Where applicable: the notified body ... (name, number)... performed ... (description of intervention)... and issued the certificate:RoHS 2011/65/EU + 2015/863
Additional information:The appliance is intended exclusively for storing packaged food

Scancool SD 1002 SLE - EU DECLARATION OF CONFORMITY - 2

EU DECLARATION OF CONFORMITY

Ref. Ares In accordance with EN ISO 17050-1:2004

Model number (unique identification of the product):SD 1002 BSLE
Name and address of the manufacturer or his authorised representative:Scandomestic A/SLinåvej 208600 SilkeborgDenmark
This declaration of conformity is issued under the sole responsibility of the manufacturer (or installer):Scandomestic A/SLinåvej 208600 SilkeborgDenmark
Object of the declaration (identification of product allowing traceability. It may include a colour image of sufficient clarity to enable the identification of the product, where appropriate.)Product: Display CoolerBrand: ScancoolColour: BlackModel name: SD 1002 BSLEScancool SD 1002 SLE - EU DECLARATION OF CONFORMITY - 1
The object of the declaration described in point 4 is in conformity with the relevant Union harmonisation legislation:EN 61000-3-2
References to the relevant harmonised standards used, or references to the specifications in relation to which conformity is declared:EN 16902:2016, Directive (EU) 2017/1369, Regulation (EU) No. 2019/2018 and Regulation (EU) No. 2019/2024 EN 60335-2-89:2010+A1: 2016 + A2: 2017 EN 60335-1:2012 + A11: 2014 + A13: 2017 + A1: 2019 + A14:2019 + A2:2019 EN 62233:2008 EN 55014-1:2017 EN 55014-1:2015 EN IEC 61000-3-2:2019 EN 61000-3-3:2013+A1: 2019, Directive 2014/30/EU, 2011/65/EU, (EU) 2015/863, REACH Regulation No 1907/2006, MD 2006/42/EC
Where applicable: the notified body ... (name, number)... performed ... (description of intervention)... and issued the certificate:RoHS 2011/65/EU + 2015/863
Additional information:The appliance is intended exclusively for storing packaged food

Scancool SD 1002 SLE - EU DECLARATION OF CONFORMITY - 2

EU DECLARATION OF CONFORMITY

Ref. Ares In accordance with EN ISO 17050-1:2004

Model number (unique identification of the product):SD 1002 BHE
Name and address of the manufacturer or his authorised representative:Scandomestic A/SLinåvej 208600 SilkeborgDenmark
This declaration of conformity is issued under the sole responsibility of the manufacturer (or installer):Scandomestic A/SLinåvej 208600 SilkeborgDenmark
Object of the declaration (identification of product allowing traceability. It may include a colour image of sufficient clarity to enable the identification of the product, where appropriate.)Product: Display CoolerBrand: ScancoolColour: BlackModel name: SD 1002 BHEScancool SD 1002 SLE - EU DECLARATION OF CONFORMITY - 1
The object of the declaration described in point 4 is in conformity with the relevant Union harmonisation legislation:EN 61000-3-2
References to the relevant harmonised standards used, or references to the specifications in relation to which conformity is declared:EN 16902:2016, Directive (EU) 2017/1369, Regulation (EU) No. 2019/2018 and Regulation (EU) No. 2019/2024 EN 60335-2-89:2010+A1: 2016 + A2: 2017 EN 60335-1:2012 + A11: 2014 + A13: 2017 + A1: 2019 + A14:2019 + A2:2019 EN 62233:2008 EN 55014-1:2017 EN 55014-1:2015 EN IEC 61000-3-2:2019 EN 61000-3-3:2013+A1: 2019, Directive 2014/30/EU, 2011/65/EU, (EU) 2015/863, REACH Regulation No 1907/2006, MD 2006/42/EC
Where applicable: the notified body ... (name, number)... performed ... (description of intervention)... and issued the certificate:RoHS 2011/65/EU + 2015/863
Additional information:The appliance is intended exclusively for storing packaged food

Scancool SD 1002 SLE - EU DECLARATION OF CONFORMITY - 2

EU DECLARATION OF CONFORMITY

Ref. Ares In accordance with EN ISO 17050-1:2004

Model number (unique identification of the product):SD 1326 BE
Name and address of the manufacturer or his authorised representative:Scandomestic A/SLinåvej 208600 SilkeborgDenmark
This declaration of conformity is issued under the sole responsibility of the manufacturer (or installer):Scandomestic A/SLinåvej 208600 SilkeborgDenmark
Object of the declaration (identification of product allowing traceability. It may include a colour image of sufficient clarity to enable the identification of the product)Product: Display CoolerBrand: ScancoolColour: BlackScancool SD 1002 SLE - EU DECLARATION OF CONFORMITY - 1
The object of the declaration described in point 4 is in conformity with the relevant Union harmonisation legislation:ISO 9001, ISO 14001, REACH 1907/2006, RoHS 2011/65/EU, 2015/863, EN 60335-1:2012 + A11: 2014, EN 60335-2-89: 2010 + A1: 2016 + A2: 2017EN 60335-1: 2012 + A11: 2014 + A13: 2017 + A1: 2019 + A14: 2019 + A2: 2019, EN 62233:2008, IEC 60335-2-89 :2010 + A1:2012 + A2:2015, IEC60335-1:2010 + A1:2013, (MD) 2006/42/EC, 2011/65/EU, 2014/30/EU, EN 55014-2:2015, EN 61000-3-2:2014,EN 61000-3-3:2013, 16902:2016, 2017/1369, 2019/2018, 2019/2024, Machine directive 2006/42/EC, EN 60335-2-89:2010+A1:2016+A2:2017, IEC 62321-3-1, EN 55014-1:2006+ A1:2009+A2:2011, 2014/30/EU, EN 55014-2:2015, EN 61000-3-2:2014, EN 61000-3-3:2013, EN 16902:2016
References to the relevant harmonised standards used, or references to the specifications in relation to which conformity is declared:EN 61000-3-2
Additional information:The appliance is intended exclusively for storing beverages
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Scancool

Model : SD 1002 SLE

Category : Fridge