P95 - Respiratory mask 3M - Free user manual and instructions
Find the device manual for free P95 3M in PDF.
| Product Type | Disposable respiratory protective mask |
| Brand | 3M |
| Model | P95 |
| Filter Type | N95 (minimum 95% efficiency against solid and liquid aerosols free of oil) |
| Protection Against | Solid and liquid particles (including oil-based) and acid gases (sulfur dioxide, chlorine) at concentrations below the permissible exposure limit |
| Do Not Use For | Gases, asbestos, sandblasting, concentrations >10× the exposure limit, organic vapors, atmospheres with O2 <19.5% |
| Storage Conditions | Temperature: -20°C to +30°C, relative humidity <80% |
| Shelf Life | Until the expiration date indicated on the packaging (if stored properly) |
| Maximum Use Duration | Up to 40 hours or 30 days for oil-based aerosols (whichever comes first) |
| Inspection Before Use | Check mask integrity, headbands, staples, nose clip; replace if damaged |
| Fit | Perform a seal check before each use (cover the mask and exhale) |
| Limitations of Use | Do not use with beard or facial hair; consult a physician if you have respiratory problems |
| Material | Free of natural rubber latex |
| Certification | NIOSH TC-84A-1166 |
| Intended Use | Industrial/professional by trained adults |
| Product References | 8576, 8271, 8577 |
| Country of Origin | United States (St. Paul, Minnesota) |
| Customer Service | 1-800-243-4630 (USA) / 1-800-267-4414 (Canada) |
Frequently Asked Questions - P95 3M
User questions about P95 3M
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Respiratory mask in PDF format for free! Find your manual P95 - 3M and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. P95 by 3M.
USER MANUAL P95 3M
EN Particulate Respirator P95
Nuisance Level Acid Gas Relief*
User Instructions
IMPORTANT: Keep these User Instructions for reference.

* 3M recommended for relief against nuisance levels of acid gas such as sulfur dioxide, hydrogen fluoride and/or chlorine. (Nuisance level acid gas refers to concentrations not exceeding OSHA PEL or applicable government occupational exposure limits, whichever is lower.)
This respirator helps protect against certain particles. Misuse may result in sickness or death. For correct use, consult supervisor and these User Instructions, or call 3M in U.S.A., 1-800-247-3941. In Canada, call Technical Service at 1-800-267-4414. In Mexico, call 01-800-712-0646.
IMPORTANT
Before use, wearer must read and understand these User Instructions. Keep insert for reference.
Use For
Particles such as those from processing minerals, coal, iron ore, cotton, flour, and certain other substances. Liquid- or oil-based particles from sprays that do not also emit harmful vapors. Nuisance-level acid gases such as sulfur dioxide, hydrogen fluoride and/or chlorine. (Nuisance-level acid gas refers to concentrations not exceeding OSHA PEL or applicable government occupational exposure limits, whichever is lower.) Follow all applicable local regulations. For additional information on 3M use recommendations for this class of respirator please consult the 3M Respirator Selection Guide found on the 3M Personal Safety Division (PSD) website at www.3M.com/respiratorselector or call 1-800-243-4630 in U.S.A. In Canada, call 1-800 267-4414.
Do Not Use For
Do not use for gases, asbestos or sandblasting; particulate concentrations that exceed either 10 times the occupational exposure limit or applicable government regulations, whichever is lower. Do not use for organic vapors, including those present in paint spraying operations, when concentrations exceed the US OSHA PEL or applicable government occupational exposure limits, whichever is lower. In the U.S., do not use when OSHA substance specific standards, such as those for arsenic, cadmium, lead in the construction industry, or 4,4'-methylene dianiline (MDA), specify other types of respiratory protection. This respirator does not supply oxygen.
Biological Particles
This respirator can help reduce inhalation exposures to certain airborne biological particles (e.g. mold, Bacillus anthracis, Mycobacterium tuberculosis, etc.) but cannot eliminate the risk of contracting infection, illness or disease. OSHA and other government agencies have not established safe exposure limits for these contaminants.
Use Instructions
- Failure to follow all instructions and limitations on the use of this respirator and/or failure to wear this respirator during all times of exposure can reduce respirator effectiveness and may result in sickness or death.
- Before occupational use of this respirator, a written respiratory protection program must be implemented meeting all the requirements of OSHA 29 CFR 1910.134 such as training and fit testing and applicable OSHA substance specific standards. In Canada, CSA standard Z94.4-93 requirements must be met and/or requirements of the applicable jurisdiction, as appropriate.
- The particles which can be dangerous to your health include those so small that you cannot see them.
- Leave the contaminated area immediately and contact supervisor if dizziness, irritation, or other distress occurs.
- Store the respirator away from contaminated areas when not in use.
- Inspect each respirator before each use to ensure that it is in good operating condition. Examine all the respirator parts for signs of damage including the two headbands, attachment points and noseclip. The respirator should be disposed of immediately upon observation of damaged or missing parts. Filtering facepieces are to be inspected prior to each use to assure there are no holes in the breathing zone other than the punctures around staples and no damage has occurred. Enlarged holes resulting from ripped or torn filter material around staple punctures are considered damage. Immediately replace respirator if damaged. Staple perforations do not affect NIOSH approval.
- Dispose of used product in accordance with applicable regulations.
Use Limitations
- This respirator does not supply oxygen. Do not use in atmospheres containing less than 19.5% oxygen.
- Do not use when concentrations of contaminants are immediately dangerous to life and health, are unknown or when concentrations exceed 10 times the permissible exposure limit (PEL) or according to specific OSHA standards or applicable government regulations, whichever is lower. Do not use when acid gas concentrations exceed the OSHA PEL or other applicable government occupational exposure limits, whichever is lower.
- Do not alter, abuse or misuse this respirator.
- Do not use with beards or other facial hair or other conditions that prevent a good seal between the face and the edge of the respirator.
- Respirators can help protect your lungs against certain airborne contaminants, however, they will not prevent entry through other routes such as the skin, which would require additional personal protective equipment (PPE).
- This respirator is designed for occupational/professional use by adults who are properly trained in their use and limitations. This respirator is not designed to be used by children.
-
Individuals with a compromised respiratory system, such as asthma or emphysema, should consult a physician and complete a medical evaluation prior to use.
-
When stored in accordance with temperature and humidity conditions specified below, the product may be used until the "use by" date specified on the packaging.
Storage Conditions and Shelf Life
Before use, store respirators in the original packaging, away from contaminated areas, dust, sunlight, extreme temperatures, excessive moisture and damaging chemicals. When stored in accordance with temperature and humidity conditions specified below, the product may be used until the "use by" date specified on packaging. Always inspect product and conduct a user seal check before use as specified in these User Instructions. If you cannot achieve a proper seal, do not enter the contaminated area. See your supervisor.

End of Shelf Life
Use respirators before the "use by" date specified on packaging

Storage Temperature Range
-20°C (-4°F) to +30°C (+86°F)

Storage Maximum Relative Humidity
<80% RH
Time Use Limitation
- If respirator becomes damaged, soiled, or breathing becomes difficult, leave the contaminated area and dispose of the respirator.
- If used in environments containing only oil aerosols, dispose of respirator after 40 hours of use or 30 days, whichever is first.
FOR MORE INFORMATION
In United States, contact:
Website: www.3m.com/workersafety
Technical Assistance: 1-800-243-4630
For other 3M products:
1-800-3M-HELPS or 1-651-737-6501
RENSEIGNEMENTS SUPPLÉMENTAIRES
Aux États-Unis :
Internet: www.3m.com/workersafety
Assistance technique:1 800 243-4630
natural_image
Line drawing of a hand holding a coiled spring or wire, labeled Fig. 1 (no text or symbols on the diagram itself)
natural_image
Illustration of a person applying oral care to their face with a tool, labeled Fig. 2 (no text or symbols on the diagram itself)
natural_image
Illustration of a person applying nasal or oral care to their face, labeled as Fig. 3 (no text or symbols on the diagram itself)
natural_image
Illustration of a person applying facial care to their face, labeled as Fig. 4 (no text or symbols on the diagram itself)Fitting Instructions
Must be followed each time respirator is worn.
- Cup the respirator in your hand, with the nosepiece at your fingertips, allowing the headbands to hang freely below your hand (Fig. 1).
- Position the respirator under your chin with the nosepiece up. Pull the top strap over your head resting it high at the top back of your head. Pull the bottom strap over your head and position it around the neck below the ears (Fig. 2).
-
Place your fingertips from both hands at the top of the metal nosepiece. Using two hands, mold the nose area to the shape of your nose by pushing inward while moving your fingertips down both sides of the nosepiece (Fig. 3).
▲ Pinching the nosepiece using one hand may result in improper fit and less effective respirator performance. Use two hands. -
Perform a User Seal Check prior to each wearing. To check fit, place both hands completely over the respirator and inhale sharply (Fig. 4). Be careful not to disturb the position of the respirator. A negative pressure should be felt inside the respirator. If air leaks around nose, readjust the nosepiece as described in step 3. If air leaks at the respirator edges, work the straps back along the sides of your head. If you CANNOT achieve a proper fit, DO NOT enter the contaminated area. See your supervisor.
Removal Instructions
See step 2 of Fitting Instructions and cup respirator in hand to maintain position on face. Pull bottom strap over head. Still holding respirator in position, pull top strap over head and remove respirator.
This respirator contains no components made from natural rubber latex.
NIOSH Approved: N95
At least 95% filtration efficiency against solid and liquid aerosols that do not contain oil.

3M St. Paul, Minnesota, USA 1-800-243-4630

THIS RESPIRATOR IS APPROVED ONLY IN THE FOLLOWING CONFIGURATIONS:
| RESPIRATOR COMPONENTS | |||||
| FILTERING FACEPIECE | |||||
| TC- PROTECTION | 1 | 8271 | 8576 | 8577 | CAUTIONS AND LIMITATIONS2 |
| 84A-1166 | P95 X X X ABC | JMNOP | |||
1. PROTECTION
P95 - Particulate Filter (95% filter efficiency level) effective against all particulate aerosols.
2. CAUTIONS AND LIMITATIONS
A - Not for use in atmospheres containing less than 19.5 percent oxygen.
B - Not for use in atmospheres immediately dangerous to life or health.
C - Do not exceed maximum use concentrations established by regulatory standards.
J - Failure to properly use and maintain this product could result in injury or death.
M - All approved respirators shall be selected, fitted, used, and maintained in accordance with MSHA, OSHA, and other applicable regulations.
N - Never substitute, modify, add, or omit parts. Use only exact replacement parts in the configuration as specified by the manufacturer.
O - Refer to users instructions, and/or maintenance manuals for information on use and maintenance of these respirators.
P - NIOSH does not evaluate respirators for use as surgical masks.
Rev. C: 09-10-02
3M PERSONAL SAFETY DIVISION
3M CENTER, BUILDING 0235-02-W-70
ST. PAUL, MN 55144-1000
3M is a trademark of 3M Company, used under license in Canada.
3M PSD products are occupational use only.
3M PERSONAL SAFETY DIVISION
3M CANADA
P.O. BOX 5757 LONDON, ONTARIO N6A 4T1
© 3M 2018
98-0060-0171-7_2
34-8720-1688-5

MISE EN GARDE
Internet : www.3M.ca/Safety
Assistance technique/Technical Assistance : 1 800 267-4414
Centre communication-client/Customer Care Center : 1 800 364-3577

natural_image
Line drawing of a hand holding a curved object with two vertical bars, labeled Fig. 1 (no text or symbols on the diagram itself)
natural_image
Illustration of a person applying facial hair to another person's ear, with no text or symbols present.
natural_image
Illustration of a person applying nasal or oral care to another person's face, labeled as Fig. 3 (no text or symbols on the diagram itself)
natural_image
Illustration of a person applying face-to-face pressure to their mouth, labeled as Fig. 4 (no text or symbols on the diagram itself)Directives d'ajustement
natural_image
Line drawing of a hand holding a coiled spring or wire, labeled Fig. 1 (no text or symbols on the diagram itself)
natural_image
Illustration of a person applying facial hair to another person's ear, with a tool near the ear (no text or symbols)
natural_image
Illustration of a person applying nasal or oral care to another person's face, labeled as Fig. 3 (no text on diagram)
natural_image
Illustration of a person applying facial care to their mouth, labeled as Fig. 4 (no text or symbols on the diagram itself)THIS RESPIRATOR IS APPROVED ONLY IN THE FOLLOWING CONFIGURATIONS:
| RESPIRATOR COMPONENTS | |||||
| FILTERING FACEPIECE | |||||
| TC- PROTECTION | 1 | 8271 | 8576 | 8577 | CAUTIONS AND LIMITATIONS2 |
| 84A-1166 | P95 X X X ABC | JMNOP | |||
1. PROTECTION
P95 - Particulate Filter (95% filter efficiency level) effective against all particulate aerosols.
2. CAUTIONS AND LIMITATIONS
A - Not for use in atmospheres containing less than 19.5 percent oxygen.
B - Not for use in atmospheres immediately dangerous to life or health.
C - Do not exceed maximum use concentrations established by regulatory standards.
J - Failure to properly use and maintain this product could result in injury or death.
M - All approved respirators shall be selected, fitted, used, and maintained in accordance with MSHA, OSHA, and other applicable regulations.
N - Never substitute, modify, add, or omit parts. Use only exact replacement parts in the configuration as specified by the manufacturer.
O - Refer to users instructions, and/or maintenance manuals for information on use and maintenance of these respirators.
P - NIOSH does not evaluate respirators for use as surgical masks.
Rev. C: 09-10-02
3M MÉXICO S.A. DE C.V.
AV. SANTA FE NO. 190
natural_image
Line drawing of a hand holding a coiled spring or wire, labeled 'Fig. 1' (no text or symbols on the diagram itself)
natural_image
Illustration of a person applying facial hair to another person's ear, with no text or symbols present
natural_image
Illustration of a person applying nasal or oral care to another person's face, labeled as Fig. 3 (no text on diagram)
natural_image
Illustration of a person applying face-to-face care with hands, labeled 'Fig. 4' (no text or symbols on the diagram itself)配戴說明
每次佩戴口罩時必須遵守。
THIS RESPIRATOR IS APPROVED ONLY IN THE FOLLOWING CONFIGURATIONS:
| RESPIRATOR COMPONENTS | |||||
| FILTERING FACEPIECE | |||||
| TC- PROTECTION | 1 | 8271 | 8576 | 8577 | CAUTIONS AND LIMITATIONS2 |
| 84A-1166 | P95 X X X ABC | JMNOP | |||
1. PROTECTION
P95 - Particulate Filter (95% filter efficiency level) effective against all particulate aerosols.
2. CAUTIONS AND LIMITATIONS
A - Not for use in atmospheres containing less than 19.5 percent oxygen.
B - Not for use in atmospheres immediately dangerous to life or health.
C - Do not exceed maximum use concentrations established by regulatory standards.
J - Failure to properly use and maintain this product could result in injury or death.
M - All approved respirators shall be selected, fitted, used, and maintained in accordance with MSHA, OSHA, and other applicable regulations.
N - Never substitute, modify, add, or omit parts. Use only exact replacement parts in the configuration as specified by the manufacturer.
O - Refer to users instructions, and/or maintenance manuals for information on use and maintenance of these respirators.
P - NIOSH does not evaluate respirators for use as surgical masks.