Ecler MIMO7272DN - Professional audio equipment

MIMO7272DN - Professional audio equipment Ecler - Free user manual and instructions

Find the device manual for free MIMO7272DN Ecler in PDF.

📄 32 pages English EN Download 💬 AI Question
Notice Ecler MIMO7272DN - page 22
View the manual : Français FR English EN
Pick your language and provide your email: we'll send you a specifically translated version.

User questions about MIMO7272DN Ecler

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Professional audio equipment in PDF format for free! Find your manual MIMO7272DN - Ecler and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. MIMO7272DN by Ecler.

USER MANUAL MIMO7272DN Ecler

text_image GPO GF CE Secondary Primary Ethernet MONITOR 3 OUT IN

https://www.audinate.com/products/software/dante-controller?lang=fr

DSP
CPUQuad core 64bits 1GHz
Sampling rate48 kHz
Latency analog IN to analog OUT<4.3 ms.
Converters
Resolution24 bit
Dynamic rangeAD:110dB, DA: 115dB
Analogue
8 Input / OutputTerminal block (Symmetrical)
2 monitor outputTerminal block (Symmetrical)
Headphones connectorJack 1/4
Analogue input headroom+27dBV = +30dBu
Max. output level+18dBV = +21dBu
Input sensitivity @0dBV outfrom -50dBV to +10dBV in 0.5dB steps
Input impedanceBalanced, >4kΩ
Phantom power+42VDC, 5mA max. software switched
Headphones>200mW/200Ω
Frequency response (-3dB)5Hz to 24kHz
Flatnessbetter than ±0.1dB
THD+Noise @ 1kHz, 0dBV input (line)<0.004%
THD+Noise @ 1kHz, -40dBV input (mic.)<0.008%
Output Noise floor FFT (20Hz - 20kHz)better than 115dB
Interchannel crosstalk (20Hz - 20kHz)better than 90dB (100dB typ.)
Channel Leakage (20Hz - 20kHz)better than 100dB (115dB typ.)
CMRR 20Hz- 20kHz65dB typ.
DanteTM/AES67 Audio interface
DanteTM/AES67 Network Tx / Rx channels64 / 64 (Brooklyn)
Latency1 / 2 / 5 ms (selectable)
Connector1xRJ45 primary, 1xRJ45 secondary
Cable length between devices100m CAT5e/CAT6

Processing

Input level (x64)Range: from Off to 0 dB
Mute: Yes
Signal Polarity reverse: Yes
Metering: VU+clip pre & post fader
Output level (x64)Range: from Off to 0 dB
Mute: Yes
Solo: Yes
Signal Polarity reverse: Yes
Metering: VU+clip pre & post fader
Output gain (x64)Range: from 0 to +6 dB
Input delay (x64)from 0 to 1000 ms. Units: sec/ms/m/cm.
Output delay (x64)from 0 to 1000 ms. Units: sec/ms/m/cm.
Parametric EQ types (4max/input - 8max/output)Bypass / On-Off all channels
Param Eq. Freq: 20Hz-20kHz; Gain: -60/+12 dB Q: 0.3 to 200
Low & High Shelf 6/12 dB/oct
Low & High Pass 6/12 dB/oct
All Pass 1/2 order
High & Low pass output X-over filters (x64)Bypass On-Off
Butterworth in 6/12/18/24 dB/oct
Bessel in 12/18/24 dB/oct
Linkwitz-Riley in 12/24 dB/oct
Input noise gate (x64)Bypass On-Off
Threshold: from -80 dBV to +18 dBV
Depth: 0 dB to 80 dB
Attack time: from 0,1 ms. to 500 ms.
Hold time: from 10 ms. to 3000 ms.
Release time: from 10 ms. to 1000 ms.
Input compressor / limiter (x64)Bypass On-Off
Threshold: from -36 dBV to +18 dBV
Knee: hard / soft
Ratio: inf:1 (limiter)
Attack time: from 0,1 ms. to 500 ms.
Release time: from 10 ms. to 1000 ms.
Make up gain: from 0 to +10 dB
Input Frequency Shifter (x64) (Feedback Loop Reducer)Per input. ON / OFF function
Output Limiter (x64)Bypass On-Off
Threshold: from -36 dBV to +18 dBV
Attack time: from 0,1 ms. to 500 ms.
Release time: from 10 ms. to 1000 ms.
Built in Signal GeneratorSine: from 20 Hz to 20 kHz
Polarity: from 20 Hz to 20 kHz
White noise
Pink noise
Stereo LinkingAdjacent input / output channels
Linked processing
Matrix routing linked
Mix MatrixSize: 64x64Analogue in/out ports: 8x8Dante/AES67 network in/out ports: 64x64Vol: Input, Output, CrosspointMute: Set/Clear individual, row, column, allInput /output Mono/stereo selectorMeter: Input /output VU and clip
Pager (x25)Input: IN1 to IN64Priorities: 25 (1 max, 25 min)Depth: 0 dB to 80 dBAntack time: from 5 ms. to 2000 ms.Release time: from 50 ms. to 3000 ms.Chime Source: None, Melody 1, Melody 2Chime Volume: from -12dB to 0dB
Mechanical
Dimensions (WxHxD)Weight482.6 x 44 x 253 mm / 19 x 1.73 x 9.96 in.3,25kg / 7.17 lb.
Power supply
MainsPower consumption90-264VCA 47-63Hz30VA
Miscellaneous
Management ConnectivityEthernet Base-Tx 10 /100Mb, 1GB Auto X-OverCAT5e or better
GPI8, from 0 to 12VDC or TTL level
GPO8, 3 poles isolated relay; 1A, 48VDC max.
Aux. Power Supply for Remotes & GPI+12VDC, 1.2A max. (short circuit protected)
Time and date retention (battery)>3 months
Programming and control application
EclerNet ManagerFrom v6.00

TP-NET PROTOCOL

SOFTWARE

Third-Party NET

USER MANUAL

12. TP-NET PROTOCOL INTRODUCTION

The TP-NET protocol lets a client device (control device) get and/or set the values of several parameters of the EclerNet compatible devices (MIMO and MIMO SG series digital matrices, DUO-NET PLAYER, NXA digital audio manager series, NZA amplifier series, NPA amplifier series, etc.), like volumes, mutes, alarms, etc. It's as well available for eMIMO1616 digital matrix, HUB series digital zoner, MIMO7272DN and MIMO4040CDN digital matrix.

The communication with these digital audio devices can be established using Ethernet and the UDP/IP transport protocol, always by means of the 5800 UDP port.

A second option for this communication is using the RS-232 interface that some of these compatible devices do also have (MIMO series, DUO-NET PLAYER, NXA series, etc.). In this case, the serial connection must fulfil the following specifications:

  1. Baud rate: 57600 (fixed, no autonegotiation) for all the devices, except for DUO-NET PLAYER, eMIMO1616, HUB series and MIMO4040CDN, which use 115200 baud rate)
  2. Data bits: 8
  3. Parity: None
  4. Stop bits: 1
  5. Flow control: None

In case the Ecler device has an Euroblock connector for the RS-232 interface, the serial cable wiring, from the device's connector to a standard DB9 serial interface connector, must be the following:

WIRING RS232 – DB9
RS232DB9
TxPin 2 (RxD)
RxPin 3 (TxD)
GndPin 5 (Signal Gnd)

The protocol is simple and direct, making it easy to read, write and modify the generated code. It is based on messages with no begin and end delimiter: each message is self-delimited by the UDP packet size, which is defined with a maximum of 80 characters. All the messages must be written in capital letters.

To let some control systems (like CRESTRON®, EXTRON®, AMX®, RTI®, VITY®, MEDIALON®, etc.) process the messages more easily, the EclerNet device adds the character LF (0x0A) to the end of each message. This way the client can buffer the messages to process them, if it's required. The EclerNet device can also handle several messages received in a single message packet by using the LF delimiter.

The available messages are built with one or more fields separated with blank spaces ( = blank space):

<TYPE> [PARAM1] [PARAM2] [PARAM3] [PARAM4][LF] 

The first field (TYPE) defines the message type and then, the required parameters for it (each kind of message requires a given number of parameters). The field TYPE can have these values:

  1. SYSTEM
  2. GET
  3. SET
  4. INC
  5. DEC
  6. SUBSCRIBE
  7. UNSUBSCRIBE
  8. DATA
  9. ERROR

At the end of this document you'll find all the available messages and their parameters for each model of the EclerNet compatible devices.

The SYSTEM, GET, SET, INC, DEC, SUBSCRIBE & UNSUBSCRIBE messages can be sent from the client to the EclerNet device. The DATA & ERROR messages can be sent from the device to the client. The only exception is the SYSTEM PING message, that is a SYSTEM type message that is sent from the EclerNet device when the initial message from the client to the device was SYSTEM CONNECT PINGPONG.

The communication (using UDP or RS-232) starts when a client sends the message SYSTEM CONNECT to the EclerNet device. As far as the UDP communication requires no connection (unlike the TCP), the EclerNet device stores this client's IP address, and then uses it as the destination IP address for the messages that it generates (DATA & ERROR). After receiving the SYSTEM CONNECT message, the device dumps its entire configuration using several consecutive DATA messages.

Note: if the configuration data dump process (usually a huge list of parameters & values) wants to be avoided after a SYSTEM CONNECT message, a SYSTEM CONNECT ONCE message can be used instead.

The communication can be terminated by two methods:

- Manually: when the client sends the SYSTEM DISCONNECT message, cancelling all the subscriptions and stopping the DATA & ERROR messages

- Automatically: in case the initial message was SYSTEM CONNECT PINGPONG and the client didn't get any SYSTEM PONG message in a period longer than 10 seconds (presuming a communication breakdown).

The SET messages don't have an automatic acknowledgement with a DATA message sent from the EclerNet device after it has processed the SET command. The client must update the values itself and must send the needed GET message if it requires confirmation from the device.

NOTES:

  • The numerical values are always integer numbers without +, -, comma or dot symbols.
  • [PINGPONG] is an optional parameter used to configure the device-client communication with a periodical check, to see whether the client or the device have terminated it. When configured this way, the device sends a SYSTEM PING once per second, and the client must answer with a SYSTEM PONG message. If anyone doesn't get these messages along a 10 seconds period, the communication will be considered terminated.
  • [ONCE] is an optional parameter used to start the device-client communication without a full data dump process (usually a huge list of parameters & values).
  • & are numerical values that identify an input or output channel of the EclerNet device. It can be within a [1...40] range for MIMO7272DN.
  • is a numerical value that identifies one available Preset stored in the EclerNet device's memory.
  • ,
     y  are numerical values in the [0..100] range that define values in a scale equivalent to [-inf..0] dB   
  • & are numerical values within the [1..8] range for MIMO7272DN.
  • is a numerical value within the [0..100] range that indicates the value. of an analogue GPI input. For a digital input only 0 or 100 are the possible values
  • is a numerical value within the [0..1] range: it can only be 0 or 1 (opened or closed GPO).
  • is a numerical value within the [1..10] range that sets the VU-meter refresh rate, or the number of times the vumeters' values are sent per second (by default = 3).
  • "" is the device name inside double quotation marks, to allow for names with blank spaces.
  • is a numerical value for an error code.
  • "" is a text chain inside double quotation marks, containing an error description.

- is a numerical value that identifies a Virtual. It can be within a [1..160] range for MIMO7272DN model.

Ecler MIMO7272DN - NOTES: - 1

ecler

13. MIMO 7272DN DIGITAL MATRIX

IMPORTANT NOTE: The communication must be started with the client sending the first message SYSTEM CONNECT to the EclerNet device. Otherwise, the commands from the client to the EclerNet device will be ignored. See TP-NET PROTOCOL INTRODUCTION chapter for additional information.

TYPEPARAM1PARAM2PARAM3PARAM4DESCRIPTION
SYSTEMCONNECT[MASTER][PINGPONG][ONCE]MASTER: this parameter, applied in SYSTEM CONNECT, is used to disconnect all clients currently connected to the device, releasing all open and not correctly closed connections, opening a new connection. In this way we guarantee that the client that has set the MASTER option is the only one connected by TP-NET to the device.PINGPONG: this parameter can be used with the MASTER parameter, the difference is that this parameter performs a periodic check to see if the communication is still open (PING PONG) or if after 10 seconds with no response, the communication has ended (PING).ONCE: this parameter is used to prevent the device status dump.
DISCONNECTCancel subscriptions and terminates communication
SUBSCRIPTION_RATEAlive message from device
PINGAlive message from device
PONGAlive ACK message from client

Ecler MIMO7272DN - MIMO 7272DN DIGITAL MATRIX - 1

ecler

PING INTERVAL<1-1000>Ping Interval, in seconds
GETALLDumps current device status (with DATA messages)
PRESETGets the current PRESET
ILEVELGets the current LEVEL of an Input Channel
OLEVELGets the current LEVEL of an Output Channel
XLEVELGets the current LEVEL of a Matrix point
IMUTEGets the current MUTE status of an Input Channel
XMUTEGets the current MUTE status of a Matrix Point
IVUGets the VU-meter value of an Input Channel
OVUGets the VU-meter value of an Output Channel
GPIGets the current value of a General Purpose Input
GPOGets the current value of a General Purpose Output
INFO_NAMEGets the Device Name
INFO_MODELGets the Device Model
INFO_VERSIONGets the Firmware Version
INFO_MACGets the Device MAC address
VIRTUAL_CONTROLGets the Virtual Control value

Ecler MIMO7272DN - MIMO 7272DN DIGITAL MATRIX - 2

ecler

TYPEPARAM1PARAM2PARAM3PARAM4DESCRIPTION
SETPRESETSets the current PRESET
ILEVELSets the current LEVEL of an Input Channel
OLEVELSets the current LEVEL of an Output Channel
XLEVELSets the current LEVEL for a Matrix point
IMUTEYES/NOSets the current MUTE status of an Input Channel
XMUTEYES/NOSets the current MUTE status for a Matrix Point
GPOSets the current value for a General Purpose Output
VIRTUAL_CONTROLSets the Virtual Control value (Value can range from 1 to 100)
INCILEVELIncreases the current LEVEL of an Input Channel by Value (Value can range from ±1 to ±100)
OLEVELIncreases the current LEVEL of an Output Channel by Value (Value can range from ±1 to ±100)
XLEVELIncreases the current LEVEL of a Matrix point by Value (Value can range from ±1 to ±100)
DECILEVELDecreases the current LEVEL of an Input Channel by Value (Value can range from ±1 to ±100)
OLEVELDecreases the current LEVEL of an Output Channel by Value (Value can range from ±1 to ±100)
XLEVELDecreases the current LEVEL of a Matrix point by Value (Value can range from ±1 to ±100)
SUBSCRIBEALLSubscribes to all VU-meters
IVUSubscribes to an Input Channel VU-meter

Ecler MIMO7272DN - MIMO 7272DN DIGITAL MATRIX - 3

ecler

OVUSubscribes to an Output Channel VU-meter
UNSUBSCRIBEALLUnsubscribe to all VU-meters
IVUUnsubscribe to an Input Channel VU-meter
OVUUnsubscribe to an Output Channel VU-meter

Note: INC and DEC commands are replied with a DATA command from the device with the resulting LEVEL value, after it has been increased or decreased. When the INC or DEC command tries to adjust a LEVEL value beyond its minimum or maximum limits, no reply (DATA command) will be produced.

Ecler MIMO7272DN - MIMO 7272DN DIGITAL MATRIX - 4

ecler

TYPEPARAM1PARAM2PARAM3PARAM4DESCRIPTION
DATAPRESETShows the current PRESET
ILEVELShows the current LEVEL of an Input Channel
OLEVELShows the current LEVEL of an Output Channel
XLEVELShows the current LEVEL for a Matrix point
IMUTEYES/NOShows the current MUTE status of an Input Channel
XMUTEYES/NOShows the current MUTE status for a Matrix Point
VIRTUAL_CONTROLShows the Virtual Control value (Value can range from 1 to 100)
IVUShows the VU-meter value of an Input Channel
OVUShows the VU-meter value of an Output Channel
GPIShows the current value of a General Purpose Input
GPOShows the current value of a General Purpose Output.
INFO_NAMEShows the Device Name
INFO_MODELShows the Device Model
INFO_VERSIONShows the Firmware Version
INFO_MACShows the Device MAC address
INFO_IPLISTShows the list of clients connected to the Device. The message will contain a list including ClientNumber ClientIP Client Port (separated by blank characters)

14. ERROR CODES FOR ECLERNET DEVICES

14.1. COMMON ERROR CODES (to all EclerNet - TP-NET compatible devices)

ERROR IDDESCRIPTION
0TPNET_ERROR_NONE = 0,
1TPNET_ERROR_INVALID_FIELD_TYPE,
2TPNET_ERROR_INVALID_FIELD_PARAM1,
3TPNET_ERROR_INVALID_FIELD_PARAM2,
4TPNET_ERROR_INVALID_FIELD_PARAM3,
5TPNET_ERROR_INVALID_FIELD_PARAM4,

14.2. MIMO7272DN SPECIFIC ERROR CODES

ERROR IDDESCRIPTION
6UDP_ERROR_TIMEOUT_PONG,
7UDP_ERROR_CONNECT_WHILE_CONNECTED,
8UDP_ERROR_DISCONNECT_WHILE_UNCONNECTED,
9UDP_ERROR_INVALID_CLIENT_IP,
10UDP_ERROR_MESSAGE_TOO_LONG,
11UDP_ERROR_UNSUPPORTED_MESSAGE,
12UDP_ERROR_UNSUPPORTED_PRESET_NUMBER,
13UDP_ERROR_UNSUPPORTED_INPUT_CHANNEL_NUMBER,
14UDP_ERROR_UNSUPPORTED_OUTPUT_CHANNEL_NUMBER,
15UDP_ERROR_UNSUPPORTED_GPI_NUMBER,
16UDP_ERROR_UNSUPPORTED_GPO_NUMBER,
17UDP_ERROR_INVALID_LEVEL_VALUE,
18UDP_ERROR_INVALID_RATE_VALUE,
19UDP_ERROR_GPO_VALUE,

Ecler MIMO7272DN - MIMO7272DN SPECIFIC ERROR CODES - 1