The Round ® U.S. Registered Trademark. U.S. Patents 7,159,789; 7,159,790; 7,476,988 and other patents pending. Copyright © 2009, Honeywell International Inc. All rights reserved.

69-1919EFS-04 The Round Easy-To - See CAUTION: TURN OFF POWERTurn off power to system at the furnace, or at the fuse/circuit breaker panel before you begin.Remove cover and thermostat, but leave wallplate with wires attached.MERCURY NOTICEIf your old thermostat contains mercury, contact your local waste management authority for proper disposal instructions.Is there a sealed tube containing mercury? If so, see mercury notice below.Leave wallplate in place.Old thermostatCover Check package contents:

1. Pull wires through base.

2. Level base if desired.

3. Markpositionsofbothscrew

holes. Label wires and remove old wallplate Use a screwdriver to disconnect wires one by one. As you disconnect each wire, wrap it with the label matching the letter on your old thermostat. (Adhesivelabelsaresuppliedinyourthermostatpackage.) Remove the old wallplate only afterallwiresarelabeled.Becarefulnotto let loose wires fall into the wall opening. Wrapsuppliedlabelssecurelyaroundeachwire. Do not let wires fall into wall opening! Mount thermostat base IGNORE WIRE COLORS: Use only letter designations to identify wire types. If your old thermostat has 7 or more wires (not countingterminalsCorC1),youmay have purchased the wrong replacement thermostat. Stop now and call 1-800-468- 1502 for advice.English: Page 1 • Français: Page 6 • Español: Página 11 3 69-1919EFS—04

1. Match each labeled wire with same

2. Use a screwdriver to loosen screw

terminals, insert bare wire into slots, then tighten screws.

3. Pushanyexcesswirebackintothe

wall opening. Labels don't match? If labels do not match letters on thermostat, see table below. Existing wires Connect to: R• RH•4• V Terminal “R” [1] Rc Terminal “Rc”[1] O Terminal “O” [2]B Terminal “B” [2]G•F Terminal “G” W•W1•H Terminal “W” Y •Y1•M Terminal “Y” C•X •B Do not use [3]

1. Pull wires through wire hole.

Position coverplate on wall, level and mark hole positions.

and subbase, position over anchors, then insert and tighten mounting screws. Check level if desired.

4. Apply the large-print labels to

the coverplate, matching the labels on the subbase. Wiring [1] If wires will be connected to both R and Rc terminals, remove metal jumper. [2]DonotconnectbothO and B if you have a heat pump. Connect only the O wire.WrapB wire with electrical tape and do not use. [3]DonotuseC, X or B.Wrapbareendof wire with electrical tape. [4] If you have two wires, connect wires to R and W. Coverplate Subbase Large-print subbase switch labels Subbase and base installationCT87N Easy-To-See

1. Align the slots on the base with tabs on the

thermostat, then push gently until the thermostat snaps into place.

2. Restore electrical power at the heating/cooling

system, or at the fuse/circuit-breaker panel. Move the switch to the proper setting for your system: F: For gas or oil heating systems, leave the fan operation switch in this factory- setposition(forsystemsthatcontrolthe faninacallforheat). E: Change the switch to this setting for heat pump or electric heat systems. (Thissettingisforsystemsthatallowthe thermostat to control the fan in a call for heat, if a fan wire is connected to the G terminal.)

Fan operation settings Cycle rate settings Thermostat mounting Coverplate and subbase Heating System Switch 1 Switch 2 Steam or gravity On On High efficiency warm air Off On (90%plusefficiency), hot water, or heat pump Gas or oil warm air Off Off (factorysetting) Electric warm air On Off Move the cycle rate switches to the proper setting for your system(seetablebelow). ThermostatEnglish: Page 1 • Français: Page 6 • Español: Página 11 5 69-1919EFS—04 Fan switch

  • On: Fan runs continuously.
  • Auto: Fan runs only when heating or cooling system is on. System switch
  • Cool: Controls the cooling system.
  • Heat: Controls the heating system.
  • Off: All systems are off. Operation Honeywell warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and service, for a period of one (1) years from the date of purchase by the consumer. If at any time during the warranty period the product is determined to be defective or malfunctions, Honeywell shall repair or replace it (at Honeywell's option).If the product is defective,(i) return it, with a bill of sale or other dated proof of pur-chase, to the place from which you purchased it; or (ii) call Honeywell Customer Care at 1-800-468-1502. Cus-tomer Care will make the determination whether the prod-uct should be returned to the following address: Honeywell Return Goods, Dock 4 MN10-3860, 1885 Douglas Dr. N., Golden Valley, MN 55422, or whether a replacement prod-uct can be sent to you.This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was caused by damage which occurred while the product was in the pos-session of a consumer.Honeywell's sole responsibility shall be to repair or replace the product within the terms stated above. HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAM-AGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you.THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON THIS PRODUCT. THE DURA-TION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE ONE-YEAR DURATION OF THIS WARRANTY. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.This warranty gives you specic legal rights, and you may have other rights which vary from state to state.If you have any questions concerning this warranty, please write Honeywell Customer Relations, 1985 Douglas Dr., Golden Valley, MN 55422 or call 1-800-468-1502. In Canada, write Retail Products ON15-02H, Honeywell Lim-ited/Honeywell Limitée, 35 Dynamic Drive, Toronto, Ontario M1V 4Z9. Temperature Current indoor temperature. Temperature setting Rotate to set, a click is heard every two degrees as the tem- perature is adjusted. Markings Enlarged, raised num- bers indicate temperature range by touch or sight. The large 5, 6, 7 and 8 mean 50, 60, 70 and 80°F, respectively.