GermGuardian GG1000 - Air purifier

GG1000 - Air purifier GermGuardian - Free user manual and instructions

Find the device manual for free GG1000 GermGuardian in PDF.

📄 12 pages English EN Download 💬 AI Question
Notice GermGuardian GG1000 - page 1
View the manual : Français FR English EN Español ES

User questions about GG1000 GermGuardian

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

L'email reste privé : il sert seulement à vous prévenir si quelqu'un répond à votre question.

No questions yet. Be the first to ask one.

Download the instructions for your Air purifier in PDF format for free! Find your manual GG1000 - GermGuardian and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. GG1000 by GermGuardian.

USER MANUAL GG1000 GermGuardian

REV0318IMPORTANT SAFETY INSTRUCTION:READ AND SAVE THESE INSTRUCTIONS BEFORE USING THE PRODUCT WARNINGS When using this product basic precautions should be followed to reduce the risk of fire, electric shock and injury. 3.5 Watt Light Bulb Replacement Part No. LB1000• Do not operate this product in any area where there is a risk of the unitfalling into or being exposed to water.• Opening windows or doors while operating this device may affect performance. • This device should not be used in the presence of oxygen or anyflammable materials or gases.

DANGER: Electrical Shock

  • Use this product only as described in this manual.• Operate this product on 120 V AC, 60 HZ only.• Do not operate without cover in place.• Do not defeat the interlock switch.• Do not operate with an extension cord.• To reduce the risk of electrical shock, this equipment has a polarizedplug (one blade is wider that the other). This plug will fit in a polarizedoutlet only one way. If the plug does not fit fully in the outlet, reversethe plug. If it still does not fit, contact qualified personnel to install theproper outlet. DO NOT alter the plug in any way. • Do not operate this product if there is any physical damage to the unit. • This product is for indoor use only.TO REDUCE THE RISK OF INJURY:• Always unplug the unit before servicing.• Close supervision is necessary when operated by children and pets.• Do not handle the unit or plug with wet hands.• Keep the product away from heated surfaces.• Do not put any object into the opening or block airflow to the unit. USE & CARE INSTRUCTIONS Pluggable UV-C Air Sanitizer Model No. GG1000 1-Year Limited Warranty Customer Service

www.guardiantechnologies.com Date Purchased month ________ year _________ English E - 1 French F - 1 Spanish S - 1 Note: Use GENUINE GuardianTechnologies replacement parts only. E-1UNDER NO CIRCUMSTANCES SHOULD YOU CLEAN THE BULB, BULB HOLDER OR CYLINDER WITH WATER OR WET SOLUTIONS. THIS COULD CAUSE ELECTRICAL SHOCK.

ALWAYS UNPLUG THE UNIT FROM ELECTRICAL

OUTLET WHEN SERVICING

LAMP CONTAINS MERCURY

Manage in accordance with Spills, Disposal and Site Cleanup Requirements. In case of breakage, follow clean-up procedures provided by contacts below. www.epa.gov/cflcleanup 1-866-284-4010 MISAPPLYING OR MISUSING THE UV-C BULB COULD CAUSE INJURY TO THE EYES OR SKIN. NEVER USE THE BULB WITHOUT INSTALLING IT IN THE UNIT AS INSTRUCTED. NEVER OPERATE THE UNIT WITHOUT THE TOP CAP IN PLACE. WARNING This product can be serviced or maintained only by changing the UV-C bulb. The unit contains no serviceable parts. All parts, except the UV-C bulb, are warranted for 1-year from date of purchase. See the Limited Warranty. Use of any bulb other than the appropriate Pluggable UV-C Air Sanitizer bulb will void warranty. You may purchase bulbs (LB1000) directly from Guardian Technologies LLC, or we can provide you with the names of retailers who stock our products in your area.The health aspects associated with this product and its ability to aid in the disinfection of environmental air have not been investigated by the CSA. The purchase of the Pluggable UV-C Air Sanitizer unit does not prevent illness. The 8 hour TWA Ozone for this product is 0.001 ppmv when tested in a 30 m3 chamber. The product complies with the maximum allowable concentration of ozone of 0.050 parts per million by volume (ppmv) in a 24-hour period. The Health Canada Guideline 2010 recommends that the maximum exposure limit, based on averaging time of 8 hours, is 0.020 ppmv or less when tested in a sealed, controlled room approximately 30 m3.

WARNING: THIS PRODUCT CAN EXPOSE YOU TO CHEMICALS INCLUDING LEAD OR LEAD COMPOUNDS, WHICH ARE

Purified air is released into the room. UV-C light kills or inactivates airborne bacteria. Fan draws in air. Plugs into outlet 3 ways. *It is recommended to run the GG1000 continuously. Opening doors and/or windows in the room may affect the performance of the device. WARNING ULTRAVIOLET-C LIGHT IS EMITTED FROM THE BULB WHEN THE UNIT IS ELECTRIFIED, EYE INJURY OR IRRITATION COULD RESULT. UNPLUG THE UNIT WHEN SERVICING THE BULB TO AVOID OVER- EXPOSURE OF EYES AND SKIN TO THE ULTRAVIOLET-C (UV-C) LIGHT. WARNING The bulb should only be used in the Pluggable (GG1000) and all instructions for use must be folllowed. Discard the used bulb by following the recommended disposal procedure for a used fluorescent bulb E-21. Plug the unit into a 120V AC electrical outlet.

2. For best results continuous operation is recommended.

NOTE: THE PLUGGABLE UV-C AIR SANITIZER UNIT

CONTAINS NOSERVICEABLE PARTS EXCEPT ITS UV-C

BULB. THE BULB MAY BE REMOVED FOR REPLACEMENT.

A replaceable 3.5 watt UV-C light bulb will last approximately 5000 hours. Over time with use the UV-C bulb will lose some intensity approximately 15% at 4000 hours. Therefore it is suggested to replace the UV-C light bulb approximately every 6 months (depending on use). You will know to change the bulb when the light flickers continuously or changes colors. Replacement bulb no. LB1000.

1. Unplug the unit from

the electrical outlet.

REPLACING THE UV-C BULB

2. Using a small Phillips

head screwdriver, loosen and remove the Phillips screw located at the top backside of the unit.

3. Remove the top cap by

lifting it off of the top of the unit.

4. Place the unit on a table

or level surface in the upright position.

5. Hold the unit in place

with one hand. Locate the bulb and reach into the cylinder.

6. With your opposite

hand, turn the bulb in a counter-clockwise direction (left) to loosen from the socket.

7. Take new bulb and screw into unit using a clockwise motion.

8. Wipe off fingerprints wirh a dry cloth after

9. Reassemble by reversing steps 1-6.

the consumer, Guardian Technologies LLC warrants this product to be free of defects in materials or workmanship commencing upon the date of the original purchase. In order to be eligible for this Limited Warranty, an original sales receipt or comparable substitute proof of purchase bearing the date of original purchase is required. Refer to the original product carton or specific product/model page on the Guardian Technologies website for warranty length for your particular model. This warranty applies only to the original purchaser of this product from the original date of purchase. This warranty covers product purchased from authorized distributors only. This warranty applies to repair or replacement of product found to be defective in materials or workmanship. This warranty does not apply to damage resulting from unusual wear, commercial, abusive, unreasonable use or supplemental damage. This warranty does not cover damage from unauthorized repairs or from any use not in accordance with the instruction manual. Defects that are the result of normal wear and tear will not be considered manufacturing defects under this warranty. If this product should become defective within the warranty period, we will repair or replace any defective parts free of charge. All warranty repairs must be completed by Guardian Technologies LLC. This warranty gives you specific legal rights and you may also have other rights (other rights may vary from state to state in the U.S.A.) To submit product under warranty the complete machine must be delivered pre-paid to Guardian Technologies LLC. Please include complete information including: the problem, the model number of the product, the day of purchase, and a copy of the original sales receipt along with your name, address, and telephone (email optional). Address returns to the attention of: Customer Service, at the address below. Additional questions or comments can be made toll free to the number listed below. USA and Canada Guardian Technologies LLC 26251 Bluestone Blvd. Euclid, Ohio 44132

WARNING: THIS PRODUCT CAN EXPOSE YOU TO CHEMICALS INCLUDING LEAD OR LEAD COMPOUNDS, WHICH ARE

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : GermGuardian

Model : GG1000

Category : Air purifier