USER MANUAL TSF 1909 Sistec
USER MANUAL BEDIENUNGSANLEITUNG2 Copyright This publication, including all photographs, and illustrations, is protected under international copyright laws, with all rights reserved. Neither this manual, nor any of the material contained herein, may be reproduced without written consent of the author. © Copyright 2019 Disclaimer The information in this document is subject to change without notice. The manufacturer makes no representations or warranties with respect to the contents hereof and specically disclaims any implied warranties of merchantability or tness for any particular purpose. The manufacturer reserves the right to revise this publication and to make changes from time to time in the content here of without obligation of the manufacturer to notify any person of such revision or changes.3 GEBRUIKERSHANDLEIDING
The electronic lock operates with a six digit code. You can programme a second opening code. Each input is confirmed by a beep and the light illuminates. After entering a valid code, a double signal sounds. If the code is an invalid code, you will hear a long beep. If you wait more than ten seconds, the entered code disappears and you have to enter it again.
1.2 Opening the safe
Enter the six digit code (factory code 123456) and unlock the door within three seconds using the handgrip or knob. If you do not open the lock within three seconds, the lock closes again automatically.
1.3 Closing the safe
Close the door and turn the handle or knob into the closed position. The lock is automatically locked. You can test whether the lock is locked by turning the handle to the open position.
If incorrect codes are entered four times in a row, the keypad blocks automatically for five minutes. The light flashes every ten seconds during this period. And if you try to use the keypad, you will hear a long signal. Entering a wrong code twice after the blocking period ends will start a new delay time of five minutes.
Once you start using the safe, change the standard factory code into your own personal access code immediately. When choosing a code, avoid obvious combinations such as numbers related to your birth date, part of your telephone number or postcode. Remember the code and keep it to yourself. If you feel the need to write it down, keep it in a safe place.
Press and hold the ‘0’ button until the light stays on
Key in the code (or factory code 123456 for the first time)
Repeat the new code, for example 567891 (the light goes out)
2. Master- or user code
2.1 Changing the master and user code
Make sure that the safe door is open when you change the code. Key in a six digit code (or factory code 123456 if you use the lock for the first time).
2.2 Setting the user code
Make sure that the safe door is open when you change the code (key in the master code). If the new code is not accepted, you hear a long signal. In that case, start again at step 1 for changing the user code. After changing the code, it is best to test the new code several times with the door open.
If the new code is not accepted, you hear a long signal. In that case, start again at step 1 for changing the code. After changing the code, it is best to test the new code several times with the door open. Step Action Key
Press and hold the ‘1’ button until the light stays on
Repeat the new user code, for example 111111 (the light goes out)
Press and hold the ‘3’ button until the light stays on
Key in the master code, for example 567891 (the light goes out)
The user code has been deleted. Only the master code remains valid. If the user code deletion is unsuccessful, you hear a long signal. In that case, start again at step 1 for deleting the user code.16
3. Opening delay and opening window
The opening delay can be 1 to 99 minutes: This the waiting time before you can open the lock. The opening window time can be 1 to 19 minutes: You have to enter the code again to open the safe during this window (the period in which you can open it). If the light goes out during programming, you have waited too long to make an entry. In that case, start again at step 1.
3.2 Opening with opening delay and opening window
Key in code - start opening delay Waiting time opening delay Opening window - re-enter your code
3.1 Programming the opening delay and opening window
Make sure that the safe door is open while you change the opening delay and window (key in seven digit code). Step Action Key
1. Press and hold the ‘9’ button until the light stays on 9
2. Key in the master code, for example 567891 567981
3. Enter the opening delay using two digits, for example 5 minutes 05
Enter the opening window using two digits, for example 1 minute
5. Repeat the opening delay time 05
Repeat the opening window time (the light goes out)
Enter the user or master code, for example 567891
The opening delay time starts, the light illuminates every few seconds
When the opening delay has elapsed, you will hear an audible signal and the opening window begins. The light illuminates every few seconds.
Open the handgrip within 3 seconds, and the safe is open17
3.3 Changing the opening delay
You can only change the opening delay during the opening window. Step Action Key
The opening delay time starts, the light illuminates every few seconds
When the opening delay has elapsed, you will hear an audible signal and the opening window begins. The light illuminates every few seconds.
4. Press and hold the ‘9’ button until the light stays on 9
Enter the opening delay time using two digits, for example 20 minutes
Enter the opening window time using two digits, for example 2 minutes
8. Repeat the new opening delay time 20
Repeat new opening window time. The opening delay has now been changed.
3.4 Deactivating the opening delay
You can only change the opening delay during the opening window. Step Action Key
The opening delay time starts, the light illuminates every few seconds
When the opening delay has elapsed, you will hear an audible signal and the opening window begins. The light illuminates every few seconds.
4. Press and hold the ‘9’ button until the light stays on 9
5. Key in the master code, for example 567891 567891
6. Key in 00 (= 0 minutes) to deactivate the opening delay 00
7. Key in 01 to deactivate opening window 01
8. Repeat 00 to deactivate the opening delay 00
Repeat 01 to deactivate opening window. The opening delay is now disabled.
4.1 Changing the battery
As soon as the battery is almost empty (and the voltage becomes too low), the light will flash and a warning signal will sound several times when you open the door. This is the warning that you need to change the battery. Do not use rechargeable batteries, only high quality 9V batteries.
BETRIEBSANLEITUNG ELEKTRONISCHES SCHLOSS BASIC
Do you have questions about your safe, the electronic lock or is there an unexpected malfunction? Please contact your local dealer. Model 1 The battery compartment is located behind the keyboard. You can open the lock at the top of the keyboard. Model 2 and 3 The integrated battery compartment in the bottom of the entry unit opens by moving a slider. Attention! You must firmly attach the battery clip to the battery. Model 2 Model 3 Model 119