Product type Piston air compressor
Power supply 230 V ~ 50 Hz
Motor power (S3/60%) 1.2 kW
Number of cylinders 1
Suction capacity 190 l/min
Effective output 110 l/min
Max. service pressure 8 bar
Tank volume 24 liters
Weight 15.5 kg
Protection degree IP 20
Protection class I
Sound level (L_WA) 97 dB(A)
Permissible ambient temperature +5 °C to +40 °C
Intended use Compressed air production for domestic and DIY use (inflation, pneumatic tools, painting, cleaning, stapling)
Maintenance and cleaning Clean with a damp cloth; drain condensate from tank after each use; replace brushes if necessary
Safety Use with 30 mA residual current circuit breaker; wear safety goggles; do not direct air stream at people
Spare parts and repairability Original spare parts available at www.guede.com; repairs by Güde after-sales service
Warranty 24 months for domestic use, 12 months for industrial use

Frequently Asked Questions - 1900824 Güde

How to drain the compressed air tank?
After each use, open the drain valve located under the tank to remove condensation water. This prevents tank corrosion.
What oil to use for the compressor?
Use a special compressor oil, for example a 5W30 oil in case of low temperatures. Consult the manual for exact specifications.
The compressor does not start, what to do?
First check that the pressure in the tank is not above the startup pressure. Check the power supply and the switch. If the problem persists, contact Güde service.
Can I use an extension cord?
Yes, but only an extension cord of maximum 5 meters with a cable cross-section of at least 1.5 mm². Longer cords or smaller cross-sections may cause voltage drops.
What is the maximum service pressure?
The maximum service pressure is 8 bar. Never exceed this value to avoid any risk.
How to clean the suction filter?
Unplug the device, remove the suction filter and clean it with compressed air or soapy water. Let it dry completely before reinstalling.
The compressor heats up and stops, why?
This may be due to overload, lack of ventilation, dirty cooling fins, or too high ambient temperature. Check these points and let it cool down.
Can I use the compressor outdoors?
Yes, but only in dry weather. Do not expose it to rain, snow, or humidity. Store it in a covered place after use.
How to maintain the safety valve?
The safety valve must be checked periodically. If it leaks, clean or replace it. Never modify it.
Where to find spare parts?
Original spare parts are available on the website www.guede.com. Use only original parts to guarantee safety.

User questions about 1900824 Güde

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Compressor in PDF format for free! Find your manual 1900824 - Güde and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. 1900824 by Güde.

USER MANUAL 1900824 Güde

KOMPRESSOR 190/08/24 ÖLFREI

50122

Güde 1900824 - KOMPRESSOR 190/08/24 ÖLFREI - 1

ENGLISH Please read the instructions carefully before starting the machine.

English TECHNICAL DATA | SPECIFIED CONDITIONS OF USE | SAFETY INSTRUCTIONS MAINTENANCE | GUARANTEE | EC-DECLARATION OF CONFORMITY 17

FRANÇAIS CARACTERISTIQUES TECHNIQUES | UTILISATION CONFORME À LA DESTINATION | CONSIGNES DE SECURITÉ | ENTRETIEN | GARANTIE | DÉCLARATION DE CONFORMITE CE 22

Service connection. 230 V~50 Hz

Motor output S3/ 60% 1,2 kW

Number of cylinders 1

Suction capacity. 190 l/min

Free air delivery. 110 l/min

Max. working pressure 8 bar

tank capacity 241

Weight. 15,5 kg

Degree of protection .IP 20

Protection class 1

Sound power level L_WA^* 97 db(A)

*Measured according to 2005/88/EC

Read and understand the operating instructions before using the appliance. Abide by all

the safety measures stated in the service manual. Act responsibly toward third parties.

In case of any doubts about connection and operation refer please to our customer center

Preserve all the documentation so that anyone who uses the compressor can consult this beforehand.

Specified Conditions Of Use

The compressor can only be used for the production of compressed air to be used at home and by handymen. - Respecting technical data and safety precautions.

The compressed air produced by the compressor cannot not be used for pharmaceutical, food or medical purposes or to fill the air bottles of scuba divers.

The compressor must be used in a suitable environment (well ventilated with an ambient temperature of between +5^ and +40^ ) and never in places with dust, acids, vapors, explosive or flammable gases.

Do not use this product in any other way as stated for normal use. Not observing general regulations in force and instructions from this manual does not make the manufacturer liable for damages.

Safety instructions

WARNING! Electric shock! There is a risk of an injury caused by electric shock!

Operation is only allowed with a safety switch against stray current (RCD max. stray current of 30mA ).

Check the voltage. Technical data given on the type label must correspond with electric network voltage.

Insert the plug of the electrical cable in a socket of suitable shape, voltage and frequency complying with current regulations.

Use extension cables with a maximum length of 5 meters and with a cable cross-section of not less than 1.5mm2 Use of extension cables of different length and cross-section and also of adapters and multiple sockets should be avoided.

Check the cable and/or socket for damages before the appliance putting into operation.

To avoid danger, a damaged mains supply pipe must be replaced by the manufacturer. Do not under any circumstances attempt any repair yourself.

Never let the compressor come into contact with water or other liquids and never direct the jet of liquids sprayed by tools connected to the compressor towards the compressor: as the appliance is live, this could cause electrocution or short-circuits.

Never use the appliance with bare feet or wet hands or feet.

Never yank the power cable to disconnect the plug from the power outlet or to move the compressor.

Warning: the compressor may restart when power is restored following a blackout.

Compressed air is a potentially dangerous form of energy; always take great care when using the compressor and its accessories.

This device is not intended for use by persons (including children) with limited physical, sensory or mental capabilities or without the necessary lack experience or knowledge unless they are supervised by a person who is responsible for their safety or were instructed by that person in how to use the device.

Children should be supervised to ensure that they do not play with the device. Always keep children and unauthorised persons out of reach of the appliance.

Never use the compressor without being supervised.

Never direct the jet of air towards persons, animals or your body.

Never keep the air flow in body holes as that could lead to fatal injuries!

Keep the work area free.

When operating, the compressor must be placed on a stable surface.

The compressor must be used in a vertical position only.

Caution! The compressor may only be used with appropriate wheels and rubber bumps.

Safety goggles should be worn when using the compressor in order to protect the eyes against any foreign bodies lifted by the jet of air.

If possible, when using air-powered accessories, wear safety clothing.

Always maintain a safety distance of at least 4 meters between the compressor and the work area.

Caution! The pneumatic hose may lash you when the quick-acting coupling is opened! The pneumatic hose should be held by hand.

Always use the handle to move the compressor.

When using compressed air, you must know and comply with the safety precautions to be adopted for each type of application (inflation, airpowered tools, painting, washing with water-based detergents only, clinching, etc.).

When using compressed air, you must know and comply with the safety precautions to be adopted for each type of application (inflation, airpowered tools, painting, washing with water-based detergents only, clinching, etc.).

Caution! Never switch the compressor on or off using the plug. Pressure switch to be pressed at all times.

Do not leave the compressor on over night as it could become a source of danger.

At the end of your working day, switch the appliance off, release the air jet and unplug the compressor.

Warning: if the water that condenses is not drained, it may corrode the receiver, reducing its capacity and impairing safety.

Never leave the appliance exposed to adverse weather conditions (rain, sun, fog, snow).

If this compressor is used outdoors, always remember to stow it after use in a covered or closed place.

Never use the compressor outdoors in rain or bad weather.

Do not place flammable or nylon/fabric objects close to and/or on the compressor.

Do not cover the air inlets on the compressor.

The compressor must not be fitted in a vehicle for industrial purposes without an inspection by an expert!

If the compressor is used for industrial purposes, it must be checked by an expert before putting into operation for the first time. Such check must be ordered by the operator (under BetrSichV Section 17 No.25 - operation safety regulation)

Caution! When fitted in automatic equipment, it is necessary to install appropriate alarm or warning devices in case of power outage or malfunction or compressor (e.g. feed line, etc.) failure.

Operation at lower temperatures

At lower temperatures, below 5^ , problems may be experienced when starting. They are manifested by growling of the electric motor. In such a case, the appliance must be immediately switched off and oil (5W30) changed in warmer conditions.

To guarantee perfect and reliable operation of the rotary and percussive pneumatic tools such as impact wrenches, staplers or nailers, etc., the compressed air must be supplied filtered - with oil via the lubricator or maintenance unit

A filtered water separator should be used for var- nishing in any case.

To select a suitable pneumatic tool, the tool air consumption and the compressor effective amount delivered must necessarily be considered.

(Pneumatic tools and accessory equipment can be

found at www.guede.com)

Requirements for operating staff

The operating staff must carefully read the Operating Instructions before using the appliance.

Qualification: Apart from the detailed instructions by a professional, no special qualification is necessary for appliance using.

Minimum age: Persons over 16 years of age can only work on the appliance. An exception includes youngsters trained in order to reach knowledge under supervision of the trainer during occupational education.

Training: Using the appliance only requires corresponding training by a professional or the Operating Instructions. No special training is necessary.

Emergency procedure

Conduct a first-aid procedure adequate to the injury and summon qualified medical attendance as quickly as possible. Protect the injured person from further harm and calm them down. For the sake of eventual accident, in accordance with DIN 13164, a workplace has to be fitted with a first-aid kit. It is essential to replace any used material in the first-aid kit immediately after it has been used.

If you seek help, state the following pieces of information:

  1. Accident site
  2. Accident type
  3. Number of injured persons
  4. Injury type(s)

Maintenance

Before carrying out any work on the machine, disconnect the plug from the socket.

Run the accessory connected dry until there is no more air in the receiver.

Prior to every use, visually check the machine to rule out any defects, in particular on the power cable and the plug.

Safety valve Functional check

The machine must not be used under any circumstances if the machine or the safety devices are damaged.

Use only original accessories and original spare parts.

Never clean the machine and its components with solvents, flammable or toxic liquids. Us only a damp

cloth making.

Only a regularly maintained and treated appliance can serve as a satisfactory aid. Insufficient maintenance and care can lead to unforeseen accidents and injuries.

If necessary, a list of spare parts can be found at www.guede.com.

Guarantee

Warranty period of 12 months applies to commercial use and 24 months applies to private use and commences on the day of purchase of the device.

The guarantee solely covers inadequacies caused by material defect or manufacturing defect. Original payment voucher with the sales date needs to be submitted for any claim in the guarantee period.

The guarantee does not cover any unauthorised use such as appliance overloading, use of violence, damage as a result of any unauthorised interference or caused by foreign items. Failing to follow the operating and assembly instructions and common wear are also not included in the guarantee.

Service

Do you have any technical questions? Any claim? Do you need any spare parts or operating instructions? We will quickly help you and without needles bureaucracy at our web pages at www.guide.com in the Servicing part. Please help us be able to help you. In order to identify your device in case of claim we need the serial No., product No. and year of production. All this data can be found on the type label. Please enter it here for future reference:

Serial No.:

Art. No:

Year of production:

Symbols

Güde 1900824 - Symbols - 1

Read the Operating Instructions!

Güde 1900824 - Symbols - 2

Before carrying out any work on the machine, disconnect the plug from the socket.

Güde 1900824 - Symbols - 3

Wear eye protective goggles! Wear ear protectors!

Güde 1900824 - Symbols - 4

Protect against humidity Never expose tool to rain.

Güde 1900824 - Symbols - 5

Cable pulling / transport prohibited

Güde 1900824 - Symbols - 6

Warning/caution!

Güde 1900824 - Symbols - 7

Dangerous voltage

Güde 1900824 - Symbols - 8

Caution - hot surface! Warning, hot surfaces!

Güde 1900824 - Symbols - 9

Danger - automatic control (closed loop)

Güde 1900824 - Symbols - 10

Warning against thrown-off items

Güde 1900824 - Symbols - 11

Keep distance of persons! Observe to keep out of dangerous zone

Güde 1900824 - Symbols - 12

Any damaged or disposed electric or electronic devices must be delivered to appropriate collection centres.

Güde 1900824 - Symbols - 13

Protect against humidity

Güde 1900824 - Symbols - 14

This side up

Failure removal

Defect Causes Measure
Compressor not starting after being switched onPressure in the air jet exceeds the closing pressureRelease the pressure in the air jet so that the pressure switch gets automatically switched on
Defective supply Have the current supply checked by an authorised person
Defective pressure switch Have the pressure switch replaced by an authorised person (Güde service centre)
Worn carbons Replace the carbons
After reaching the closed pressure, the compressor runs or buzzes for a short time and then switches off automaticallyElectric cable is too long or its cross section is too smallCheck the length and cross section of the electric cable
Compressor running constantly Suction filter is very dirty Clean or replace the suction filter
Pneumatic tools have high air consumptionCheck the pneumatic tool air consumption; seek an authorised compressed air dealer
Leaking on the compressor Localise the leaking, contact the Güde service centre
Compressed-air pipeline leaking Contact the Güde service centre
Drain valve is open or missing Close or insert the drain valve
Compressed air is released from the discharge valve under the pressure switch when the appliance is being operatedDischarge valve is leaking Clean or replace the discharge valve
After reaching the cut-off pressure, air is released from the discharge valve under the pressure switch until the closing pressure is reachedCheck valve insert is leaking or defectiveClean or replace the check valve insert →14
Check valve is damaged Replace the check valve
Compressor gets started too often Too much condensate in the air jet Drain the condensate
Compressor is overloaded
Safety valve blowing offPressure in the air jet exceeds the set cut-off pressureHave the pressure switch adjusted/replaced by an authorised person (Güde service centre)
Safety valve is defectiveReplace the safety valve or contact the Güde service centre
Compressor getting warm too muchAir supply is not sufficientMake sure sufficient air supply and outlet (minimum distance from wall is 40 cm) is provided
Cooling fins on the cylinder (cylinder head) are dirtyClean the cooling fins on the cylinder (cylinder head)
Too long time of appliance operationSwitch the compressor off
Compressor being overheated and keeps switching offCompressor is overloadedContact the Güde service centre
Compressor is defectiveContact the Güde service centre
Compressor under undervoltage Contact the Güde service centre
Outdoor temperature of 35°C

\section*{Caracteristiques Techniques}

  • Misurato conf. 2005/88/EC

Güde 1900824 - \section*{Caracteristiques Techniques} - 1

Güde 1900824 - \section*{Caracteristiques Techniques} - 2

Translation of the EC-Declaration of Conformity

We, hereby declare the conception and construction of the below mentioned appliances correspond - at the type of construction being launched - to appropriate basic safety and hygienic requirements of EC Directives.

In case of any change to the appliance not discussed with us the Declaration expires.

Annex IV Notified Body Name: No: Adress:

Type Ex.Cert.-No.:

97/68/EC & 2016/1628/EU Emission No.:
2000/14/EC_2005/88/EC