Airforce F30 60 S4 - Basket

F30 60 S4 - Basket Airforce - Free user manual and instructions

Find the device manual for free F30 60 S4 Airforce in PDF.

📄 52 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Airforce F30 60 S4 - page 8
Pick your language and provide your email: we'll send you a specifically translated version.
Product type Decorative hood
Brand Airforce
Model F30 60 S4
Installation type External evacuation or recirculation (charcoal filter)
Number of speeds 4 suction speeds
Lighting LED (on/off switch)
Control type Mechanical buttons
Grease filter Metallic, dishwasher safe (short cycle, low temperature)
Charcoal filter Active, replace every 6 months (recirculation version only)
Minimum installation distance 50 cm (electric cooking) / 65 cm (mixed or gas cooking)
Power supply voltage 220-240 V (according to label)
Power cable length 1250 mm
Required electrical protection 30 mA residual current device
Material Stainless steel
Width 60 cm (model 60)
Use For adults and children over 8 years old under supervision
Exterior cleaning Soft cloth and neutral liquid detergent
Grease filter cleaning Monthly, by hand or dishwasher
Bulb replacement Contact customer service for the LED unit
Standard Conforms to IEC 61591, WEEE Directive 2002/96/EC

Frequently Asked Questions - F30 60 S4 Airforce

What is the difference between ducted and recirculation versions?
The ducted version expels air outside via a duct (not supplied). The recirculation version recycles air through a charcoal filter (not supplied) and releases it through the top grille.
How to install the hood above an electric hob?
The minimum distance between the hood and the cooking surface must be 50 cm for electric cooking. For gas or mixed cooking, the distance is 65 cm.
How to clean the grease filter?
The metallic grease filter must be cleaned once a month. Use a non-aggressive detergent by hand or in a dishwasher at low temperature, short cycle. Any discoloration does not affect its efficiency.
When should the charcoal filter be replaced?
The active charcoal filter must be replaced every 6 months under normal use. It is neither washable nor recyclable.
What to do if the LED lighting no longer works?
The LED lamps must be replaced by the technical support service as replacement of the complete unit is necessary.
How to completely switch off the motor?
To turn off the motor, press the active speed button (1, 2, 3 or 4) again until it returns to its initial position.
Can I use the hood with gas cooking?
Yes, but ensure a minimum distance of 65 cm and provide adequate room ventilation. Never flambé food under the hood.
Can the hood be installed on a plasterboard wall?
No, fixing on a wall that cannot support the weight (e.g. plasterboard) is not recommended. The wall must be solid.
How to reduce the energy consumption of the hood?
Use the lowest speed suitable for cooking, do not let the hood run for more than 15 minutes after cooking, and turn off the lights when leaving the area.
What to do if the power cable is damaged?
The damaged cable must be replaced by the manufacturer, its technical service, or a qualified person to avoid any hazard.

User questions about F30 60 S4 Airforce

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Basket in PDF format for free! Find your manual F30 60 S4 - Airforce and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. F30 60 S4 by Airforce.

USER MANUAL F30 60 S4 Airforce

EN INSTRUCTIONS ON MOUNTING AND USE

Key 1: activates the motor at level-one suction power
Key 2: activates the motor at level-two suction power
Key 3: activates the motor at level-three suction power
Key 4: activates the motor at level-four suction power

F

The appliance should not be used by children under 8 years of age and by persons with reduced physical, sensory and mental capabilities, or lack of experience and knowledge, unless they are supervised or have received instructions regarding the safe use of the appliance and are aware of the possible risks. Children must not play with the appliance. Any intended cleaning and maintenance by the user should not be carried out by children unless supervised. The hood should never be used without without the grid properly fitted! Never use the hood without the grill properly fitted!

The accessible components can overheat when the cooktop is in use.

The hood must not be connected to the flues of other appliances that run on gas or other fuels. When the hood is used at the same time as other appliances that run on gas or other fuels, provision must be made for an adequate supply of air. No food must be cooked flambe underneath the hood. The use of an unprotected flame could cause damage to the filters and could cause fires, so should be avoided. When frying food, never leave the pan unattended because the cooking oil could flare up. Please comply with the technical and safety provisions set forth by your local competent authorities regarding the ventilation of hoods.

This appliance conforms to European Directive 2002/96/EC, Waste Electrical and Electronic Equipment (WEEE). Please dispose of this product correctly in the interest of health and the environment.

The symbol on the product, or on the documents accompanying the product, indicates that this appliance may not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. Disposal must be carried out in accordance with local environmental regulations for waste disposal. For more detailed information about treatment, recovery and recycling of this product, please contact your local city office, your household waste disposal service or the shop where you purchased the product. If the power cable is damaged you should, in the interest of safety, contact the manufacturer or the manufacturer's technical assistance service to request a replacement, or ask someone who is similarly qualified.

Check also the drawings on the initial pages with the alphabetical and numerical references in the explanatory text. Closely follow the instructions in this manual. We cannot accept liability for any faults, detriment or fire damage to the appliance due to non-compliance with the manual's instructions.

You should affix the hood to a wall of sufficient weight-bearing capacity, so not to one made of plasterboard.

The cooker hood must be placed at a minimum distance of 50~cm from the cooking plane for electric cookers and 65~cm for gas or mixed cookers. If the instructions for installation for the gas hob specify a greater distance, this has to be taken into account. Do not tile, grout or silicone this appliance to the wall. Surface mounting only. Do not fix chimney flue to furniture or fly over shelves unless the chimney flue can be easily removed, in case maintenance is ever required.

The cooker hood is provided with an upper air exit B for discharging fumes externally for models including chimney flue C (Suction Version A- exhaust pipe not supplied). If cooking fumes and vapours cannot be externally discharged, the cooker hood can be used in the recirculating version F: the installation of 1 active charcoal filter F allows the recirculation of fumes and vapours through the upper grid G.

Make sure that there is a power socket near the hood and that the system has a 30mA differential. The mains voltage must be the same as that on the label inside the hood. The hood has a 1250mm power cable with or without plug: if it does have a plug, connect the hood to an accessible approved socket; or if it does not (connection direct to the mains), fit an approved bipolar switch with a minimum contact opening of no less than 3mm (accessible). This installation and electrical connection must be executed by a qualified technician.

If the cooking top is in use, the cooker hood must always operate.

Product performance test carried out in accordance with standard (EU) No 65/2014-Ref: IEC 61591

Maximum performance is achieved by placing the mobile panels, if any, in the open position.

T13246

Airforce F30 60 S4 - T13246 - 1

Light key: Lights ON/OFF.

Key 1: activates the motor at level-one suction power; press key 1 to turn it off.

Key 2: activates the motor at level-two suction power; press key 2 to turn it off.

Key 3: activates the motor at level-three suction power; press key 3 to turn it off.

Key 4: activates the motor at level-four suction power; press key 4 to turn it off.

To turn off the motor, the suction power keys must be in their original position.

Maintenance

Prior to any maintenance operation ensure that the cooker hood is disconnected from the electrical outlet.

Cleaning

The hood must be cleaned frequently both inside (apart from the area behind the grease filter) and outside. Use a cloth moistened with neutral liquid detergents. Never use products containing abrasives.

Warning

Failure to carry out the basic standards of the cleaning of the cooker hood and replacement of the filters may cause fire risks. Therefore we recommend observing these instructions.

Anti-grease Filter

must be cleaned once a month, with non-abrasive detergents, by hand or in dishwasher on low temperature and short cycle. When washed in a dishwasher, the grease filter may discolour slightly, but this does not affect its filtering capacity.

Charcoal Filter - (only for filter version)

The active charcoal filters F are not washable nor regenerative.

It should be changed every 6 months in normal use.

The active charcoal filters capture unpleasant cooking odours.

Reducing environmental impact:

To reduce energy consumption, we recommend you always use the lowest suction speed among those suitable for the cooking mode currently active, avoid leaving the appliance running for more than 15 minutes after burner shutdown and switch off the lights if you leave the cooking area.

Replacing lightbulbs

Warning! Prior to touching the light bulbs ensure they are cooled down.

Led Light

If the lighting group LED does not work, please contact the technical service center in order to replace the whole group.

Warning

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Airforce

Model : F30 60 S4

Category : Basket