USER MANUAL WPB 18 LT BL 11150 Quick DS METABO

Operating Instructions Chargers are only suitable for charging original Metabo and CAS (Cordless Alliance System) battery packs. This device is not designed for use by persons (including children) with physical, sensory or mental disabilities, or with insufficient experience and/or knowledge, unless they are supervised by a person responsible for their safety, or have received instructions on how to use the device by this person. ASC 290 is suitable for charging Li-Ion battery packs (12 V - 36 V, 1.3 Ah - 10 Ah, 3-10 cells). The device is suitable for charging electronic devices with a USB-C interface (like smartphones, MP3 players, tablets, etc.) - no data exchange ASC 145 is suitable for charging Li-Ion battery packs (12 V - 36 V, 1.3 Ah - 10 Ah,

ASC 55 is suitable for charging Li-Ion battery packs (12 V - 36 V, 1.3 Ah - 10 Ah,

ASC 55 is suitable for charging NiCd battery packs (12 V, 1.7 Ah, 10 cells). SC 30 is suitable for charging Li-Ion battery packs (12 V - 18 V, 1.3 Ah - 10 Ah,

Never attempt to charge batteries that are not rechargeable. Danger of explosion! The user bears sole responsibility for any damage caused by inappropriate use. Generally accepted accident-prevention regulations and accompanying safety instructions should be observed. IMPORTANT SAFETY INSTRUCTIONS

1.READ AND FOLLOW ALL SAFETY

INSTRUCTIONS - This manual contains important safety and operating instructions for battery charger model ASC55_627046000 / ASC145_627380000 / ASC290_

2. Before using battery charger, read all instructions

and cautionary markings on battery charger, battery, and product using battery.

3. CAUTION - To reduce risk of injury, charge only

Metabo and CAS (Cordless Alliance System) rechargeable batteries. Other types of batteries may burst causing personal injury and damage. Repairs to electrical tools must be carried out by a qualified electrician ONLY. Please accompany the tool for repair with a description of the fault. We reserve the right to make alterations in line with advances in technology. SAVE THESE INSTRUCTIONS Read the Operating Instructions. For your own protection and for the protection of your charger pay attention to all parts of the text that are marked with this symbol! Danger - electrical voltage! Only use the charger indoors. WARNING Unplug immediately if the cable is damaged! Unplug immediately if any sign of smoke or flames! Do not submit the casing to impact! Do not drill into the casing! Keep away from children! Do not use in a bathroom. Keep away from moisture! Do not use an extension cord. Chargers should only be operated between 32°F and 103°F (0 - 40°C). Batteries should only be charged when batterytemp is between 32°F and 120°F (0 - 50°C). Do not throw battery packs in a fire or immerse in water! Return faulty or used Metabo battery packs to your dealer! Do not dispose of battery packs along with domestic refuse. Please recycle! The charger is not suitable for charging non- rechargeable batteries. Use indoors only. Do not expose to rain. All ventilation slots must be kept free at alltimes! To reduce the risk of electric shock -Disconnect power to the receptacle before installing or removing the unit.

Slightly acidic, flammable fluid may leak from defective Li-ion battery packs! If battery fluid leaks out and comes into contact with your skin, rinse immediately with plenty of water. If battery fluid leaks out and comes into contact with your eyes, wash them with clean water and seek medical treatment immediately. Do not recharge a fully charged battery pack! Protect the charger from moisture. Children should be supervised to ensure that they do not play with the tool. Keep children away from the battery charger and the working area! Keep your battery charger out of reach of children! Do not insert objects into the ventilation slots on the battery charger – there is a danger of electric shocks and short circuits! Do not use faulty battery packs. In areas with high metal dust exposure do not load any battery packs with AIR COOLED chargers. ASC 290: Only use the original Metabo network connection line. SYMBOLS: ................ Class II Construction V .................. Volts Hz ................ Hertz A .................. Amperes ~................. Alternating Current See page 2. The illustrations are regarded as exemplary for all devices. 1 Sliding seat 2 Operation display 3 Warning display 4 Charge status indicator * 5 USB cover * 6 USB-C port * 7 LED indicator (USB-C port supplied with voltage) *

  • depending on the model

efore plugging in, check to see that the rated mains voltage and mains frequency, as specified on the rating label, match your power supply. Devices such as this one, which generate direct current, may have an effect on basic residual- current circuit breakers. Use type F or better, with a release current of max. 30 mA.

efore commissioning the charger, ensure that the air slots are free. Minimum distance to other objects is 5 cm.

Insert mains supply plug. The warning display (3) and the operating indicator (2) light up one after the other for approx. 1 second and the installed fan runs for approx. 5 seconds.

6.1 Charging battery pack

Push the battery pack completely to the stop on the sliding seat (1). The operating indicator (2) flashes. Note: To have the charge level displayed on Li-ion battery packs, first take the battery pack out of the charger and then press the button on the battery pack.

6.2 Conservation charge

Once the charging process has finished, the battery charger automatically switches to conservation mode. The battery pack can remain in the battery charger and is therefore always ready for use. The operating display (2) lights up continuously.

6.3 ASC 290 only: Charge USB device

Only connect USB devices which are compatible with the USB standard. Using incompatible devices can lead to malfunctions, damage or injuries. Open the cover (5) and plug a USB device with a suitable cable into the USB-C port (6). The device is charged. The USB-C port (6) is only supplied with voltage (LED indicator (7) illuminated) if no battery pack is charged. If a battery pack and USB device are connected at the same time, the USB charging process will start automatically after the end of the battery pack charging process.

7.1 Warning display (3) lights up

continuously Battery pack is not charged. Temperature too high/ too low. When the temperature of the battery pack

3. Special Safety Instructions

is between 0 °C and 50 °C, the charging process begins automatically. ASC 290: Warning display (3) lights up continuously and charge status indicator (4) flashes: Charger is hot, or battery pack is cold or hot, battery pack is charged with reduced charging capacity.

7.2 Warning display (3) flashes

  • Battery pack is defective. Remove the battery pack immediately from the charger.
  • The battery pack was not pushed correctly onto the sliding seat (1). See section 6.1.
  • ASC 290: Warning display (3) lights up and charge status indicator (4) is off: battery pack is not charged. charger too hot. Repairs to the charger must only be carried out by qualified electricians. If the mains connection cable of this tool is damaged, in order to prevent endangering personnel and property it must be replaced by the manufacturer, or the Customer Service of the manufacturer, or a similarly qualified person. Contact your local Metabo representative if you have Metabo chargers requiring repairs. For addresses see www.metabo.com. Observe national regulations on environmentally compatible disposal and on the recycling of disused machines, packaging and accessories. See page 3. U = Voltage ranges of the battery packs C = Battery pack capacity

= Charging current t = Charging time

USB = Voltage and max. charging current of the USB-C port

Example charging times for selected battery packs. Real charging times may deviate from the specifications depending on the residual capacity and the temperature of the battery pack. Recommended ambient temperature when charging: 32°F (0°C) to 104°F (40 °C) Changes due to technological progress reserved.

9. Environmental Protection