DKF 11R - Basket MIELE - Free user manual and instructions
Find the device manual for free DKF 11R MIELE in PDF.
Download the instructions for your Basket in PDF format for free! Find your manual DKF 11R - MIELE and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. DKF 11R by MIELE.
USER MANUAL DKF 11R MIELE
Read these instructions carefully and keep them in a safe place for future reference. Incorrect use could lead to injury or damage. Miele can not be held liable for any injury or damage caused by non-compliance with these instructions. Keep these instructions in a safe place and ensure that all users are familiar with the contents. Pass them on to any future owner of the appliance. These filters may only be used cooker hoods that they are designed for use with or in a Miele recirculation box. The cooker hood/recirculation box must only be used for the purpose it is designed for. Please observe the instructions given in the Operating instruction manual supplied with the cooker hood/recirculation box. Please observe the instructions given in this manual with regards to cleaning and reactivating these filters. These charcoal filters must not be cleaned in a dishwasher! Residual detergent can get into the filters if cleaned in a dishwasher. High oven temperatures used in subsequent reactivation in an oven can lead to these detergent residues self- igniting.en - Operating instructions
Function Charcoal filters are required for reducing odours with recirculation mode cooker hoods. They are fitted in the cooker hood above the grease filters or in a separate recirculation box. These charcoal filters can be reused several times by reactivating them in an oven or in a steam combination oven. Please observe the instructions regarding recirculation mode in the operating instruction manual supplied with your cooker hood. Installation Fitting charcoal filters DKF 12-R: Remove the grease filters from the cooker hood. Please follow the illustrations shown at the end of this instruction manual: the charcoal filter cassette is fitted into the vapour extraction frame in the cooker hood. It hooks into the grille at the back and is then secured by the catch at the front of the grille. The position of the catch will vary depending on the style of grille. DKF 11-R, 21-R*, 25-R, 1000-R: Please follow the illustrations shown at the end of this instruction manual. *Cooker hood DA 6700/6708 D: please read the instructions in the cooker hood manual before opening the recess for the charcoal filters.en - Operating instructions
Cleaning and care When should the charcoal filter be reactivated? Reactivation should be carried out when the charcoal filter is no longer effective at neutralising odours. It should be reactivated at least every 6months. Using for the first time: if your cooker hood has a charcoal filter operating hours counter please activate it. Instructions on how to do so are given in the operating instruction manual for the cooker hood. Removing charcoal filters DKF 12-R: This charcoal filter consists of two parts. The charcoal filter cassette a is fitted in a frame b. The charcoal filter cassette has to be taken out of this frame for reactivation. Use a pointed instrument, e.g. a small screwdriver to release the catch c. Carefully take the charcoal filter cassette out of the frame. Reactivate the charcoal filter cassette as described below. Only the frame can be cleaned in a dishwasher. After reactivation replace the charcoal filter cassette in the frame. Secure the catch c. DKF 11-R, 21-R*, 25-R, 1000-R: Please follow the illustrations shown at the end of this instruction manual. *Cooker hood DA 6700/6708 D: please read the instructions in the cooker hood manual before opening the recess for the charcoal filters.en - Operating instructions
Reactivating charcoal filter These charcoal filters must not be cleaned in a dishwasher! They must be reactivated in an oven or in a steam combination oven using the oven function only. Do not wash the charcoal filters by hand. These charcoal filters are breakable. When handling them be careful not to drop them. Do not press against the webbing either. Wipe the charcoal filters with a damp cloth before reactivating them. Do not use any cleaning agents. If your oven has a removable grease filter in the back of the oven compartment please remove it. See the instruction manual supplied with the oven for instructions on how to do this. Do not pre-heat the oven. Place the charcoal filters on the rack in the centre of the oven. Switch the oven on, or the oven function of your steam combination oven on, and select: Fan plus 200°C. During the reactivation process odours may be given off. During the reactivation process make sure that the room is well ventilated. Open a window if necessary. Reactivation duration: 60minutes. Switch the oven off, or the oven function on your steam combination oven off, once this process has finished. Do not take the charcoal filters out of the oven whilst still hot and do not place them on heat-sensitive surfaces whilst hot. Do not refit them in your cooker hood whilst still hot. Leave them in the oven compartment until they have cooled down. Refit the charcoal filters once they have been reactivated. If your cooker hood has a charcoal filter operating hours counter , it must be reset after reactivating the filter. Please observe the operating instruction manual for your cooker hood for instructions on how to do this. Service life The charcoal filters should be replaced every 3 years. Disposing of charcoal filters Used charcoal filters can be disposed of with the normal household waste.es - Advertencias e indicaciones de seguridad