Product typePortable dehumidifier
BrandDanby
ModelDDR050EAWDB
Power supply120 V ~ 60 Hz, 15 A circuit, grounded
Adjustable humidity range35% RH to 80% RH in 5% increments
Continuous modeYes (bypasses humidity sensor)
Timer0.5 to 24 hours (auto on/off)
Fan speed2 speeds: low and high
DisplayCurrent ambient humidity (±5%)
Full bucket indicatorYes, with automatic compressor shut-off
Auto defrostYes
Auto restart after power failureYes
Settings memoryYes
Air filterWashable, cleaning recommended every 250 hours
Water tankWith safety float
Continuous drainYes, by gravity (garden hose not included)
Operating temperature5°C to 32°C
Casters4 casters included for mobility
Warranty24 months for functional parts
Customer service1-800-26-Danby (1-800-263-2629)

Frequently Asked Questions - DDR050EAWDB DANBY

How to set the desired humidity?
Use the and buttons to set the humidity between 35% and 80% RH in 5% increments. For drier air, press (lower percentage), for more humid air, press (higher percentage).
What to do if the "full bucket" light turns on?
The light indicates that the tank is full or incorrectly positioned. Empty the bucket and replace it correctly. The unit will automatically resume operation after 2-3 minutes. Never tamper with the safety float.
How to use continuous mode?
Press the key until CO displays on the screen. This mode bypasses the humidity sensor and runs the compressor continuously to achieve the driest possible conditions.
How to set the timer?
For auto shut-off: while the unit is running, press Timer, then set the duration from 0.5 to 24 hours using the and buttons. For auto start: with the unit off, press Timer and set the start time.
How to clean the air filter?
The filter light turns on after 250 hours. Remove the filter from the back of the unit, vacuum the dust or wash it with warm water and mild detergent. Make sure it is completely dry before putting it back. Press the filter button to reset the indicator.
What do error codes EH, E1, E2 or P1 mean?
EH: humidity sensor fault. E1 or E2: temperature sensor fault. P1: water bucket not installed correctly. To clear, turn off and unplug the unit for 2 minutes, then turn on again. If the code persists, contact customer service.
Can I use a hose for continuous drainage?
Yes, remove the plug at the back and connect a standard garden hose (GHT thread). The hose should not exceed 1.8 meters and must be without kinks or knots. Note that drainage is by gravity, there is no pump.
Why won't my unit start?
Check that the plug is properly inserted, that the fuse or circuit breaker is not tripped, that the tank is in place, and that the ambient humidity is not lower than the setting. After a power failure, a 3-minute protection delay may delay startup.
How to install the casters?
The casters and power cord are inside the bucket. Remove the bucket, take off the cover, take out the casters, put the cover back, and replace the bucket. Tilt the unit at 45° and push each caster into the base until you hear a click.
How often should I clean the tank?
Clean the tank every few weeks to prevent mold. Use warm water and mild detergent. Do not wash in dishwasher and do not use bleach or harsh chemicals.

User questions about DDR050EAWDB DANBY

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Humidifier in PDF format for free! Find your manual DDR050EAWDB - DANBY and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. DDR050EAWDB by DANBY.

USER MANUAL DDR050EAWDB DANBY

This product is factory equipped with a power supply cord that has a three-pronged grounded plug. It must be plugged into a mating grounding type receptacle in accordance with the National Electrical Code and applicable local codes and ordinances. If the circuit does not have a grounding type receptacle, it is the responsibility and obligation of the customer to exchange the existing receptacle in accordance with the National Electrical Code and applicable local codes and ordinances. The third ground prong should not, under any circumstances, be cut or removed. Never use the cord, the plug or the appliance when they show any sign of damage. Do not use your appliance with an extension cord. Improper connection of the grounding plug can result in risk of fire, electric shock and/or injury to persons associated with the appliance. Check with a qualified service representative if in doubt that the appliance is properly grounded.

DANBY DDR050EAWDB - 1

IMPORTANT - MÉTHODE POUR LA MISE À LA TERRE

Owner's Use and Care Guide 1 - 12

  • Welcome
  • Important Safety Information
    • Installation Instructions
    • Operation Instructions
    • Care and Maintenance
  • Troubleshooting
  • Warranty

DÉSHUMIDIFICATEUR PORTATIF

Read and follow all safety rules and operating instructions before first use of this product.

Welcome to the Danby family. We are proud of our quality products, and we believe in dependable service. We suggest that you read this Owner's Manual before plugging in your new appliance as it contains important operational information, safety information, troubleshooting and maintenance tips to ensure the reliability and longevity of your appliance. Visit www.Danby.com to access self-service tools, FAQs and much more. For additional assistance call 1-800-263-2629.

Note the information below; you will need this information to obtain service under warranty. To receive service, you must provide the original receipt.

Model Number:

Serial Number:

Date of Purchase:

NEED HELP?

Before you call for service, here are a few things you can do to help us serve you better:

Read this Owner's Use and Care Guide:

It contains instructions to help you use and maintain your appliance properly.

If you received a damaged appliance:

Immediately contact the retailer (or builder) that sold you the appliance.

Save time and money:

Check the Troubleshooting section at the end of the guide before calling. This section helps you solve common problems that may occur.

If you do need service, you can relax, knowing help is only a phone call away.

DANBY DDR050EAWDB - Save time and money: - 1

natural_image Simple black-and-white icon of a telephone handset inside a circle (no text or symbols)

1-800-26- Danby

(1-800-263-2629)

DANBY DDR050EAWDB - Save time and money: - 2

Important Safety Information READ AND FOLLOW ALL SAFETY INSTRUCTIONS

NOTE

The instructions issued in this manual are not meant to cover all possible conditions and situations that may occur. Person(s) installing, maintaining, or operating the appliance must exercise caution and care. Failure to install, maintain, and/or operate the equipment according to the manufacturer's instructions may result in conditions which can produce personal injury and damage to your unit and/or property damage. Contact your dealer, service agent, and/or the manufacturer about any problems or conditions you do not fully understand.

For Danby Consumer Service call (1-800-263-2629).

ELECTRICAL REQUIREMENTS

To reduce the risk of fire, electric shock, or personal injury, all wiring and grounding must conform with the latest edition of Local and National Electrical codes.

  • It is the customer's responsibility to have the wiring and fuses checked by a qualified electrician to make sure adequate electrical power is available.
  • This appliance is designed to operate on an effectively grounded, separately branched, polarized, 3-wire, 120 Volt 60 Hertz (alternating current) circuit protected by a 15 ampere fuse, equivalent fuse or circuit breaker. The three-prong grounding plug on the power cord should be plugged directly into the aforementioned receptacle rated 110/120 V.A.C.
  • Do not connect the dehumidifier to a multiple socket outlet that is also being used for other electrical appliances.

FOR YOUR SAFETY: To reduce the risk of fire or explosion, do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.

GROUNDING INSTRUCTIONS

Improper connection of the equipment-grounding conductor can result in a risk of electrical shock. Check with a qualified electrician or serviceperson if you are in doubt as to whether your appliance outlets are properly grounded.

  • This appliance must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electrical shock by providing a path of least resistance for electrical current. This appliance is equipped with a cord that has an equipment-grounding conductor and 3 prong grounding plug. The plug must be connected into an outlet that is properly installed and grounded in accordance with all local codes and ordinances.
  • Do not modify the plug provided with this appliance. If it will not fit the outlet, have a proper outlet installed by a qualified electrician.
  • If the household electrical supply does not meet the above specifications, or if you are not sure your home has an effective ground, have a qualified electrician or your local electrical utility company check it and correct any problems.

SAVE THESE INSTRUCTIONS

SAFETY PRECAUTIONS

When using this dehumidifier, always follow basic safety precautions, including the following:

  • Use this appliance only for its intended purpose as described in this Owner's Manual.
  • This dehumidifier must be properly installed and grounded as described in this manual before it is used.
  • Never operate this dehumidifier in an area that is likely to accumulate standing water. If this condition develops, disconnect the power supply before stepping into the water.
  • Never unplug your dehumidifier by pulling on the power cord. Always grip the plug firmly and pull straight out from the receptacle.
  • Immediately replace all electric service cords that have become frayed or damaged. A damaged power supply cord must be replaced with a new power supply cord obtained from the manufacturer and not repaired. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end.
  • If the receptacle does not match the plug, the receptacle must be changed out by a qualified electrician.
  • Turn the dehumidifi er OFF and unplug it before cleaning.
  • All dehumidifiers contain refrigerants, which under federal law must be removed prior to product disposal. If you are disposing of a product with refrigerants, check with the company handling disposal about what to do. Check for local regulatory compliance regarding the approved and safe disposal of this appliance.
  • This dehumidifier is intended for indoor residential applications only. This dehumidifier should not be used for commercial or industrial applications. Do not use outdoors.
    • Children must be supervised to ensure that they do not play with the appliance.
  • Do not store or use combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
  • Do not remove the Styrofoam in the float which is located in the bucket.
  • Do not use an extension cord, this unit must be plugged directly into the receptacle.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience or knowledge unless they have been given supervision or instruction concerning the unit of the appliance by a person responsible for their safety.

SAVE THESE INSTRUCTIONS

DANBY DDR050EAWDB - SAVE THESE INSTRUCTIONS - 1

Installation Instructions

LOCATION

  • Select a suitable location, ensuring there is easy access to an electrical outlet.
  • Make sure there are no obstructions restricting airflow through the front air intake grill.
  • Maintain a minimum clearance of at least 30 - 45 cm (12 - 18") on all sides of the unit to allow for proper air circulation.

- The unit should be operated in an enclosed area; keep all nearby doors and windows closed.

- Place the unit on a smooth, level floor that is strong enough to support the unit with a full bucket of water.

- The unit has four rolling castor feet. Use care when moving the unit on carpet as the castors may not be able to roll correctly.

- Do not move the unit with water in the bucket; the unit may tip over and spill water.

- Protect wood and carpet floors from spillage or scratches when moving unit.

• The recommended operating ambient room temperature is between 5°C (41°F) and 32°C (90°F).

Above 5°C (41°F) Below 5°C (41°F) 18" 18" 12"

CASTOR INSTALLATION

The castors and power cord can be found inside the water bucket.

Fig. 1

  • Remove the bucket from the unit.
  • Remove the bucket cover.
  • Remove the castors and power cord.
  • Replace the bucket cover.
  • Replace the bucket in the unit.

Fig 2.

• Tilt the dehumidifi er 45°.
- Push the castors into the bottom of the unit until they click.
- Ensure the ring around the castor is fl ush against the bottom of the unit.

Note: if the unit is placed on its side or back, ensure that the unit is allowed to stand upright and undisturbed for a minimum of 4 hours before turning it on to allow the coolant to settle.

Note: castors may already be installed on some models.

Four castors in plastic bag Fig.1 45° ≤a Ring around caster Fig.2

DANBY DDR050EAWDB - Fig 2. - 2

Operating Instructions

CONTROL PANEL INSTRUCTIONS

Diagram showing numbered UI icons with labels 1 through 8, likely representing a system or control panel layout.

When you push the button to change operation modes, the unit will make a beeping sound to indicate that it is changing modes.

  1. Filter Button and Indicator Light: The check filter light will illuminate after 250 hours of operation. After cleaning the filter, press the filter button to reset this function and the light will go off.
  2. Fan button and Indicator Light: Controls the fan speed. Press to select either low or high fan speed. The indicator light will illuminate on high fan speed and will turn off on low fan speed.
  3. (V / ∧) Buttons: The humidity level can be set within a range of 35% RH (Relative Humidity) to 80% RH in 5% increments using these buttons. For drier air, press the (√) button and set to a lower percentage value (%). For more damp air, press the (∧) button and set a higher percentage value (%).
  4. Timer Button and Indicator Lights: Press to initiate the auto-start and auto-stop feature. Set a start or stop time from 0.0 to 24 hours using the ( ) and ( ) buttons.
  5. Power Button: Press to turn the dehumidifier on or off.
  6. Bucket Full Indicator Light: When the bucket is full or incorrectly positioned inside the unit, the bucket full light will turn on and remain on until the bucket is emptied or correctly re-positioned. The compressor and fan motor operation will stop. When the bucket is emptied or correctly repositioned, the dehumidifi er will resume operation automatically. Note: It may take 2-3 minutes before operating conditions resume.
  7. Continuous Mode: To reach continuous mode, press the (V) button until CO shows on the display. This setting will disregard the ambient humidity and will run the compressor continuously to reach the driest conditions possible.
  8. Display: Shows the actual (± 5% accuracy) room humidity level in a range of 35% RH to 80% RH. Otherwise, displays selection when programming humidity or timer.

Note: The fan does not shut off the moment you remove the bucket, the fan will shut off after 2-3 minutes.

DANBY DDR050EAWDB - CONTROL PANEL INSTRUCTIONS - 2

Operating Instructions

DEHUMIDIFYING MODE INSTRUCTIONS

When the power button is pressed, the power light turns on and the dehumidifier automatically defaults to:

Display: Current ambient room humidity (RH%)

Humidity Setting: 50% RH

Fan Speed: Low

Note: Depending on humidity conditions of the surrounding environment, the dehumidifier may not start automatically under the default setting. This indicates that the humidity level of the surrounding environment is lower than the default setting of 50% RH.

Press the down button to lower the set humidity until the humidity sensor recognizes conditions that will allow the unit to operate. When the set humidity reaches a point lower than the surrounding environment, the compressor will turn on and the unit will begin collecting water from the air.

Dehumidifying Mode Selection:

The unit enters dehumidify mode when the power button is pressed.

Press the up and down buttons to select a desired RH operating value (35%-80%). Each press will change the set humidity by 5%.

OR

Press the (√)button until CO shows on the display to reach continuous mode. When continuous mode is selected, the humidity sensor will be by-passed and the compressor will operate non-stop regardless of humidity conditions.

Fan Speed Selection:

You can choose a fan speed (low or high) using the keypad. The indicator light will illuminate on high fan speed and will turn off on low fan speed.

For optimal performance, ensure that the unit is set at least 10% lower than the relative humidity level in the surrounding environment. It is normal for the humidity to vary by 5% above or below the set humidity.

It is recommended that in normal conditions the humidity be set at 40-45%.

During operation, it is normal for the dehumidifier to exhaust warm air from the top of the unit.

DANBY DDR050EAWDB - Fan Speed Selection: - 1

Operating Instructions

TIMER FUNCTIONS

Follow these steps to program the Auto-on or Auto-off feature using the control panel:

Auto-off:

  1. When the unit is on, press the Timer button to activate the Auto-off timer. The Auto-off indicator light will illuminate.
  2. Press or hold the ( ) and ( ) buttons to change the 'Auto' time by 0.5 hour increments, up to 10 hours, then at 1 hour increments up to 24 hours. The unit display will count down the time remaining until start.
  3. Within 5 seconds of setting auto-off time, press the Timer button again to complete the auto-off program.

Auto-on:

  1. When the unit is off, press the Timer button to activate the auto-on program. Set the auto-on time as in step 2 above. Within 5 seconds of setting auto-on time, press the Timer button again to complete the auto-on program.

Note: Turning the unit on or off at any time or changing the on/off timer setting to 0.0 will cancel the timer settings.

MEMORY SETTING

Each time the unit is disconnected / re-connected and/or in the event of a power failure, the electronic circuit board automatically defaults to the last program setting that was used. After the unit has stopped, it may take several minutes before operating conditions resume.

AUTO-RESTART

If the unit shuts off unexpectedly due to a power outage, it will restart with the previous function settings automatically when the power resumes.

AUTOMATIC DEFROST

If the unit is operating in an environment where the ambient temperature is very cold, frost may form on the evaporator coils. The compressor will cycle off but the fan will continue to run until the frost melts. An error code may show on the control panel display.

When the frost has melted, the compressor function will resume and the unit will return to regular operation.

To ensure frost does not form on the evaporator coils, ensure the ambient temperature around the unit is at a comfortable level. Higher ambient temperature will also help to remove humidity from the air.

DANBY DDR050EAWDB - AUTOMATIC DEFROST - 1

Operating Instructions

WATER BUCKET OPERATION

The water bucket holds accumulated condensed water and by means of a safety switch, controls both the water level and operation of the dehumidifi cation process.

When the water bucket is full or displaced inside the unit, the float switch actuator (inside the bucket) breaks contact with the safety switch. This results in the immediate shut down of the compressor, preventing moisture from being condensed. The fan will continue to run for approximately 2-3 minutes. Water may drip from the tray onto the base of the unit, and then onto the floor. Ensure that you protect your wood and carpet flooring when emptying the water bucket.

Never tamper with or attempt to defeat the water level safety float switch system. Proper installation of the water bucket is crucial in maintaining reliable dehumidifier operation.

Never place a full bucket of water on the floor. The bottom of the bucket is uneven and it will tip over and spill water onto the floor.

The bucket should be cleaned every few weeks to prevent mold growth. Only use mild detergent to clean the bucket; do not use harsh chemicals or bleach.

DANBY DDR050EAWDB - WATER BUCKET OPERATION - 1

natural_image Illustration of a hand inserting a device into a box, showing internal components and a scroll (no text or symbols)

NOTE: Hold bucket with both hands when emptying.

DANBY DDR050EAWDB - WATER BUCKET OPERATION - 2

natural_image Illustration of two hands exchanging a rectangular object, possibly a device or folder (no text or symbols visible)

*There is no handle on the bucket

AIR FILTER

The fi Iter indicator will illuminate after 250 hours of use, indicating that the fi Iter should be cleaned.

  • Remove the fi iter from the back of the unit.
  • Use a vacuum to remove dust from the filter or wash with warm water and mild detergent.
  • Ensure the filter is completely dry before replacing it in the unit.
  • Press the filter button to reset the filter indicator.

CAUTION: Do not operate the unit without the filter.

DANBY DDR050EAWDB - AIR FILTER - 1

natural_image Line drawing of a portable air conditioner unit with cooling fan and control panel (no text or symbols)

DANBY DDR050EAWDB - AIR FILTER - 2

Operating Instructions

CONTINUOUS DRAIN

Water can be automatically drained from the unit by attaching a standard garden hose to the continuous drainage port on the back of the unit. When the drain hose is connected, water collected by the unit will bypass the water bucket and will drain directly through the hose.

  • Ensure the unit is on a level surface. If the unit is not level, water may bypass the drain hose and collect in the water bucket.
  • Unscrew the cap on the back of the unit to access the garden hose nozzle.
  • Attach a garden hose onto the nozzle and lead it to a floor drain.
  • Cut the garden hose to ensure it is no longer than 1.8 m (6 feet).

Note: The thread standard for garden hoses is known as GHT or "garden hose thread" which has an outer diameter of 27 mm (1 1/16 inches) and a pitch of 11.5 TPI or "threads per inch".

DANBY DDR050EAWDB - CONTINUOUS DRAIN - 1

natural_image Line drawing of a portable air conditioner unit with ventilation grilles and wheels (no text or symbols)

Drain hose

Ensure that there are no bends or knots in the drain hose as this can cause water to back up into the water bucket.

Note: there is no drain pump in this unit, the drain is activated by gravity alone.

Note: the drain hose is not provided, it must be purchased separately.

Drain Hose Installation Reference Guide
Diagram showing four stages of a device with checkmark and cross symbols indicating status or failure, likely for assembly or testing instructions.

CLEANING

1. Clean the grill and case

Use water and a mild detergent. Do not use bleach or abrasives. Do not splash water directly onto the main unit; doing so may cause an electric shock, cause the insulation to deteriorate, or cause the unit to rust. Use a vacuum attachment or brush to clean the air intake and outlet grills.

2. Clean the bucket

Clean the water bucket every few weeks to prevent growth of mold, mildew and bacteria. Partially fill the bucket with clean water and add a small amount of mild detergent. Swish it around in the bucket, empty and rinse.

Note: Do not use a dishwasher to clean the bucket. After cleaning, the bucket must be placed and properly positioned for the dehumidifier to operate.

3. Clean the air fi Iter

Remove and clean the filter every few weeks based on normal operating conditions.

  • Be sure to unplug the unit before cleaning or servicing.
  • Do not use gasoline, paint thinner or other chemicals to clean the unit.
  • Do not wash the unit directly under a tap or using a hose; it may cause electrical damage.

LONG TERM STORAGE

Before placing the unit in storage, allow the unit to stand undisturbed and turned off for at least 24 hours to ensure the inside of the unit is completely dry. Clean the unit and ensure all parts are completely dry before storage. Secure the power cord with the power cord strap as per the below and then cover the unit with a plastic bag to protect it from dust. Make sure to store the unit upright in a dry, well ventilated place.

Technical diagram showing two views of an air conditioner unit with labeled components and a schematic illustrating the assembly process.

ERROR CODES

EH - humidity sensor fault

E1 or E2 - temperature sensor fault

P1 - water bucket is not installed correctly

To clear error codes, turn off and unplug the unit, wait 2 minutes, plug back in and power on. If error code persists, call for service.

PROBLEM POSSIBLE CAUSE SOLUTION

Dehumidifi er does not startThe dehumidifi er is unpluggedThe fuse is blown/circuit breaker is trippedDehumidifi er has reached its preset level or bucket is fullBucket is not in the proper positionPower failureMake sure the plug is pushed completely into the outletCheck the house fuse/circuit breaker box and replace the fuse or reset the breakerThe unit turns off automatically when either condition occurs. Change to a lower setting or empty the bucket and replace properlyThe bucket must be in place and securely seated for the unit to operate.There is a protective time delay (up to 3 minutes) to prevent tripping of the compressor overload. For this reason, the unit may not start normally for 3 minutes after it is turned back on.
Dehumidifi er does not dry the air as it shouldDid not allow enough time to remove the moistureAirfl ow is restrictedDirty fi lterThe humidity control may not be set low enoughDoors and windows may not be closed tightlyClothes dryer may be blowing moisture-laden air into the roomRoom temperature is too lowWhen fi rst installed, allow at least 24 hours to maintain the desired drynessMake sure there are no curtains, blinds or furniture blocking the front or back of the dehumidifi er. See the “Location” section.See the “Air fi lter” sectionFor drier air, press the down button and set to a lower percent value (%)Check that all doors, windows and other openings are securely closedInstall the dehumidifi er away from the dryer. The dryer should be vented to the outside.Moisture removal is best at higher room temperatures. Lower room temperatures will reduce the moisture removal rate. Modes are designed to be operated at temperatures above 5°C (41°F)
Dehumidifi er runs too much but does not collect waterNeed to reset controllerSet to lowest humidity setting. Allow bucket to fill and then empty bucket. Adjust controller to desired % RH.
Dehumidifer runs too much collects waterArea to be dehumidifed is too largeDoors and windows are openThe capacity of your dehumidifi er may not be adequateClose all doors and windows
Frost appears on the coilsUnit has been recently turned on, or room temperature is too coldThis is normal. Frost will usually disappear within 60 minutes. See the “Defrost” section
Controls cannot be setThe compressor will turn off and the fan will automatically continue to run for approx. 3 minutes at a fi xed settingThis is normal. Wait approximately 3 minutes and set the fan as desired.
Fan noise• Air is moving through the dehumidifi erThis is normal
Water on floorHose connection may be looseBucket used to collect water, but the hose is attachedCheck the hose connection. See “Continuous Drain” sectionDisconnect the hose if using the bucket to collect water, see “Continuous Drain” section.

LIMITED CARRY-IN APPLIANCE WARRANTY

This quality product is warranted to be free from manufacturer's defects in material and workmanship, provided that the unit is used under the normal operating conditions intended by the manufacturer.

This warranty is available only to the person to whom the unit was originally sold by Danby Products Limited (Canada) or Danby Products Inc. (U.S.A.) (hereafter "Danby") or by an authorized distributor of Danby, and is non-transferable.

TERMS OF WARRANTY

Plastic parts, are warranted for thirty (30) days only from purchase date, with no extensions provided.

First 24 months

During the first twenty four (24) months, any functional parts of this product found to be defective, will be repaired or replaced, at warrantor's option, at no charge to the ORIGINAL purchaser.

To obtain service

Danby reserves the right to limit the boundaries of "In Home Service" to the proximity of an Authorized Service Depot. Any appliance requiring service outside the limited boundaries of "In Home Service", it will be the consumer's responsibility to transport the appliance (at their own expense) to the original retailer (point of purchase) or a service depot for repair. See "Boundaries of In Home Service" below. Contact your dealer from whom your unit was purchased, or contact your nearest authorized Danby service depot, where service must be performed by a qualified service technician. If service is performed on the units by anyone other than an authorized service depot, or the unit is used for commercial application, all obligations of Danby under this warranty shall be void.

Boundaries of in-home service

If the appliance is installed in a location that is 100 kilometers (62 miles) or more from the nearest service center your unit must be delivered to the nearest authorized Danby Service Depot, as service must only be performed by a technician qualified and certified for warranty service by Danby. Transportation charges to and from the service location are not protected by this warranty and are the responsibility of the purchaser.

Nothing within this warranty shall imply that Danby will be responsible or liable for any spoilage or damage to food or other contents of this appliance, whether due to any defect of the appliance, or its use, whether proper or improper.

EXCLUSIONS

Save as herein provided, by Danby, there are no other warranties, conditions, representations or guarantees, express or implied, made or intended by Danby or its authorized distributors and all other warranties, conditions, representations or guarantees, including any warranties, conditions, representations or guarantees under any Sale of Goods Act or like legislation or statute is hereby expressly excluded. Save as herein provided, Danby shall not be responsible for any damages to persons or property, including the unit itself, howsoever caused or any consequential damages arising from the malfunction of the unit and by the purchase of the unit, the purchaser does hereby agree to indemnify and hold harmless Danby from any claim for damages to persons or property caused by the unit.

GENERAL PROVISIONS

No warranty or insurance herein contained or set out shall apply when damage or repair is caused by any of the following:

1) Power failure.
2) Damage in transit or when moving the appliance.
3) Improper power supply such as low voltage, defective house wiring or inadequate fuses.
4) Accident, alteration, abuse or misuse of the appliance such as inadequate air circulation in the room or abnormal operating conditions (extremely high or low room temperature).
5) Use for commercial or industrial purposes (ie. If the appliance is not installed in a domestic residence).
6) Fire, water damage, theft, war, riot, hostility, acts of God such as hurricanes, floods etc.
7) Service calls resulting in customer education.
8) Improper Installation (ie. Building-in of a free standing appliance or using an appliance outdoors that is not approved for outdoor application). Proof of purchase date will be required for warranty claims; so, please retain bills of sale. In the event warranty service is required, present this document to our AUTHORIZED SERVICE DEPOT.

Warranty Service

Carry-In

Danby Products Limited

PO Box 1778, Guelph, Ontario, Canada N1H 6Z9

Telephone: (519) 837-0920 FAX: (519) 837-0449

1-800-263-2629

07/14

Danby Products Inc.

PO Box 669, Findlay, Ohio, U.S.A. 45840

Telephone: (419) 425-8627 FAX: (419) 425-8629

natural_image Illustration of a hand inserting a device into a container, showing internal components and a scroll (no text or symbols)
natural_image Illustration of two hands holding a rectangular object, one open and one closed, with no visible text or symbols.
natural_image Line drawing of a portable air conditioner unit with ventilation grilles and wheels (no text or symbols)

DANBY DDR050EAWDB - Carry-In - 1

natural_image Line drawing of a portable air conditioner unit with ventilation grilles and control buttons (no text or symbols)

DANBY DDR050EAWDB - Carry-In - 2

natural_image Line drawing of a portable air conditioner unit with ventilation grille and coiled cable (no text or symbols)

tuyau de drainage

Technical diagram showing a device with ventilation system and its internal connection, including a close-up of the component.

CODES D'ERREUR

PROBLÈME CAUSE POSSIBLE SOLUTION

natural_image Simple black-and-white icon of a telephone handset inside a circle (no text or symbols)

1-800-26-Danby

(1-800-263-2629)

DANBY DDR050EAWDB - CODES D'ERREUR - 1

natural_image Line drawing of a refrigerant air conditioner unit (no text or symbols)

45° ≤ a

DANBY DDR050EAWDB - CODES D'ERREUR - 3

natural_image Line drawing of a portable air conditioner unit with control panel and side arm (no text or symbols)

DANBY DDR050EAWDB - CODES D'ERREUR - 4
Fig.2

Diagram showing numbered UI icons with labels 1 through 8, including symbols like refresh, rotate, and power button.

natural_image Illustration of a hand inserting a device into a file folder, showing internal components and a scroll (no text or symbols)
natural_image Illustration of two hands holding open or folded documents, no text or symbols present
natural_image Line drawing of a portable air conditioner unit with cooling fins and wheels (no text or symbols)

DANBY DDR050EAWDB - CODES D'ERREUR - 6

natural_image Line drawing of a portable air conditioner unit with ventilation grilles and control buttons (no text or symbols)

DANBY DDR050EAWDB - CODES D'ERREUR - 7

natural_image Line drawing of a portable air conditioner unit with ventilation grille and coiled cable (no text or symbols)

Manguera de drenaje

LIMPIEZA

natural_image Technical line drawing of an air conditioner unit with attached hoses and a close-up inset showing cable connection (no text or symbols)

CÓDIGOS DE ERROR

Danby Products Limited

PO Box 1778, Guelph, Ontario, Canada N1H 6Z9

Telephone: (519) 837-0920 FAX: (519) 837-0449

1-800-263-2629

07/14

Danby Products Inc.

PO Box 669, Findlay, Ohio, U.S.A. 45840

Telephone: (419) 425-8627 FAX: (419) 425-8629

PORTABLE DEHUMIDIFIER

All repair parts are available for purchase or special order when you visit your nearest service depot. To request service and/or the location of the service depot nearest you, call the TOLL FREE number.

When requesting service or ordering parts, always provide the following information:

  • Product Type
  • Model Number
  • Part Number
  • Part Description

DESHUMIDIFICADOR PORTÁTIL

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : DANBY

Model : DDR050EAWDB

Category : Humidifier