IFM OW5006 - Infrared detector

OW5006 - Infrared detector IFM - Free user manual and instructions

Find the device manual for free OW5006 IFM in PDF.

📄 10 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice IFM OW5006 - page 5
View the manual : Français FR Deutsch DE English EN
Pick your language and provide your email: we'll send you a specifically translated version.
Title Description
Product type Pressure sensor
Measurement range 0 to 10 bar
Output Analog signal 4-20 mA
Power supply 24 V DC
Housing material Stainless steel
Operating temperature -25 to 85 °C
Usage Industrial applications for pressure measurement
Maintenance Regular calibration check recommended
Safety Compliant with CE safety standards
General information Compatible with various fluids, easy installation

Frequently Asked Questions - OW5006 IFM

What is the product type of the IFM OW5006?
The IFM OW5006 is a liquid level sensor.
How to install the IFM OW5006?
Ensure the sensor is mounted vertically in the tank at an appropriate distance from the liquid level.
What is the operating temperature range of the IFM OW5006?
The IFM OW5006 operates within a temperature range of -25 °C to 70 °C.
How to calibrate the IFM OW5006?
To calibrate the sensor, follow the instructions provided in the user manual to adjust the settings according to your application.
What to do if the IFM OW5006 does not detect the liquid level?
Check if the sensor is properly installed and clean. Also ensure the liquid level is within the detection range.
Is the IFM OW5006 waterproof?
Yes, the IFM OW5006 is designed to be waterproof and can be used in humid environments.
What power supply voltage is required for the IFM OW5006?
The IFM OW5006 requires a power supply voltage of 10 to 30 VDC.
How to clean the IFM OW5006?
Use a soft, damp cloth to clean the sensor. Avoid harsh chemicals.
Where can I find the user manual for the IFM OW5006?
The user manual can be downloaded from the IFM website or obtained from your dealer.
Can the IFM OW5006 be used with corrosive liquids?
It is recommended to check the sensor compatibility with the type of liquid before use.

User questions about OW5006 IFM

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Infrared detector in PDF format for free! Find your manual OW5006 - IFM and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. OW5006 by IFM.

USER MANUAL OW5006 IFM

Function and features

Infrared heat sensors absorb the heat radiation of objects and convert it into a switching signal.

They are used for object detection or temperature monitoring.

Switching temperature 350^ / 750^ (depending on the type of unit).

Installation

Align the sensor towards the object to be detected and mount it. A special mounting base is available as accessory (order no. E20426) for simple mounting.

The object must at least have the switching temperature of the sensor and must cover the visible area which depends on the chosen angle of aperture and sensing distance.

IFM OW5006 - Installation - 1

Calculation of diameter of visible area/sensing distance/angle of aperture

$$ \begin{array}{l} d = 2 \times I \times \tan \frac {\alpha}{2} + \varnothing \ I = 0. 5 \times \frac {d - \varnothing}{\tan \frac {\alpha}{2}} \ \end{array} $$

$$ \alpha = 2 \times \tan^ {- 1} \left(\frac {d - \varnothing}{2 \times I}\right) $$

$$ \begin{array}{l} \alpha = \text {a n g l e o f a p e r t u r e} \ l = \text {s e n s i n g d i s t a n c e} \ d = d i a m e t e r o f v i s i b l e a r e a \ \varnothing = \text {l e n s d i a m e t e r} \ \end{array} $$

Sensing range diagram:

IFM OW5006 - Installation - 2

In the event of ranges of >5m radiation losses must be taken into account. The temperature of the object should therefore be much higher than the switching temperature of the sensor.

Electrical connection

IFM OW5006 - Electrical connection - 1

Disconnect power, then connect the unit according to the wiring diagram.

IFM OW5006 - Electrical connection - 2
DC PNP

IFM OW5006 - Electrical connection - 3
DC NPN

IFM OW5006 - Electrical connection - 4
AC/DC*

Note: insert a miniature fuse according to the technical data sheet, if specified.

Recommendation: check the unit for reliable function after a short cirucit.

Core colours of ifm sockets: BN = brown, BU = blue, BK = black,

GN/YE = green/yellow.

*Output not short-circuit protected.

Short circuit can lead to immediate destruction of the unit.

Operation

Check the safe functioning of the sensor.

If in the application wrong switching occurs due to background radiation (e.g. ovens), use units with higher switching temperatures.

For applications in difficult environments (e.g. dust, vapour) or in the event of heat reflections of the environment use infrared heat sensors with a protective tube (order no. E20427).

If necessary, keep the optics clean by means of passing compressed air into the connection piece of the protective tube.