PHILIPS Sonicare AirFloss HX8212 - Interdental brush

Sonicare AirFloss HX8212 - Interdental brush PHILIPS - Free user manual and instructions

Find the device manual for free Sonicare AirFloss HX8212 PHILIPS in PDF.

📄 72 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice PHILIPS Sonicare AirFloss HX8212 - page 6
Pick your language and provide your email: we'll send you a specifically translated version.
Product type Interdental brush
Brand Philips
Model Sonicare AirFloss HX8212
Power Built-in rechargeable battery, mains charger included
Initial charging time 24 hours
Battery life Approximately 2 weeks (14 uses)
Charge indicator Green light (charging), yellow light (low battery)
Reservoir capacity Approx. 5 ml (water or mouthwash)
Spray mode Air burst and microdroplets, manual or continuous activation (1 burst/s)
Automatic shut-off After 4 minutes of inactivity
Nozzle (tip) Interchangeable, replace every 6 months
Cleaning Rinse the nozzle after each use, wipe the handle with a damp cloth
Charger maintenance Unplug before cleaning, wipe with a damp cloth
Materials Plastic, stainless steel (nozzle)
Safety Do not immerse charger, do not use in dishwasher
Recommended use Adults and children from 8 years old under supervision
Compatibility Water or mouthwash (except based on isopropyl myristate)
Warranty International warranty (except nozzle)
Recycling Removable rechargeable battery, follow removal instructions
Package contents Handle, charger, nozzle, reservoir, instructions

Frequently Asked Questions - Sonicare AirFloss HX8212 PHILIPS

How long should I charge the AirFloss for the first time?
The first charge should last 24 hours. Afterwards, a full charge takes about the same time.
How do I replace the nozzle (tip)?
Align the new nozzle facing the front of the handle and push it in until you hear a click. Replace the nozzle every 6 months for optimal performance.
Can I use mouthwash in the reservoir?
Yes, you can use mouthwash or water. Avoid mouthwashes based on isopropyl myristate or with high concentration of essential oils.
How do I clean the AirFloss?
Rinse the nozzle with water after each use. Open the reservoir and rinse it. Wipe the handle with a damp cloth. Do not put in dishwasher.
What should I do if the light flashes yellow?
The yellow light indicates a low battery: fewer than 3 uses remaining. Recharge the device by placing it on the charger.
Is the AirFloss waterproof?
The handle and nozzle are water-resistant, but the charger must never be immersed. Do not submerge the handle in water.
How do I remove the battery at the end of life?
First discharge the device by pressing the activation button until empty. Open the handle with a screwdriver, cut the wires and remove the battery. This process is irreversible.
Can I use the AirFloss if I have braces?
Consult your dentist before use, especially if you have had recent dental treatment. The device may be suitable, but medical advice is recommended.
What is the battery life of the AirFloss?
A full charge provides up to 2 weeks of use (approximately 14 sessions) under normal use.
What should I do if the nozzle does not click in?
Make sure the nozzle is aligned correctly (the head facing forward). If it does not click into place, replace it with a new one.

User questions about Sonicare AirFloss HX8212 PHILIPS

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Interdental brush in PDF format for free! Find your manual Sonicare AirFloss HX8212 - PHILIPS and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. Sonicare AirFloss HX8212 by PHILIPS.

USER MANUAL Sonicare AirFloss HX8212 PHILIPS

Always here to help you

Register your product and get support at www.philips.com/welcome

Question? Contact Philips

Philips Sonicare

AirFloss

PHILIPS Sonicare AirFloss HX8212 - AirFloss - 1

natural_image Diagram of a folded paper or document with two panels, each showing an open page and a black arrow indicating direction (no text or symbols present)

Diagram of an electric toothbrush with numbered parts for identification and assembly reference.

ENGLISH 6
DEUTSCH 13
ΕΛΛΗΝΙΚΑ 21
ESPAÑOL 30
FRANÇAIS 38
ITALIANO 46
NEDERLANDS 54
PORTUGUÊS 62

Introduction

Congratulations on your purchase and welcome to Philips! To fully benefit from the support that Philips offers, register your product at

www.philips.com/welcome.

Use the AirFloss as part of your oral care routine. In addition to brushing, it helps reduce plaque.

Important

Read this user manual carefully before you use the appliance and save it for future reference.

Danger

- Keep the charger away from water. Do not place or store it over or near water contained in a bathtub, washbasin, etc. Do not immerse the charger in water or any other liquid. After cleaning, make sure the charger is completely dry before you connect it to the mains

Warning

- The mains cord cannot be replaced. If the mains cord is damaged, discard the charger. Always have the charger replaced with one of the original type in order to avoid a hazard.

- If the appliance is damaged in any way (AirFloss nozzle, handle and/or charger), stop using it.

- This appliance contains no serviceable parts. If the appliance is damaged, contact the Consumer Care Centre in your country (see chapter ‘Guarantee and support’).

- Do not use the charger outdoors or near heated surfaces.

- This appliance can be used by children aged from 8 years and above and by persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and if they understand the hazards involved.

Children shall not play with the appliance.

Cleaning and user maintenance shall not be made by children unless they are older than 8 and supervised.

Caution

- If you have had recent oral or gum surgery, suffer from an ongoing dental condition or had extensive dental work in the previous 2 months, consult your dentist before you use this appliance.

- Consult your dentist if excessive bleeding occurs after using this appliance or if bleeding continues to occur after 1 week of use.

- If you have medical concerns, consult your doctor before you use this appliance.

- This Philips appliance complies with the safety standards for electromagnetic devices. If you have a pacemaker or other implanted device, contact your physician or the appliance manufacturer of the implanted appliance prior to use.

- Do not use attachments other than the ones recommended by the manufacturer.

- Do not exert excessive pressure on the guidance tip of the nozzle.

ENGLISH8

  • To avoid physical injury, do not fill the reservoir with hot water. Do not put foreign objects in the reservoir.
  • Only use the AirFloss for its intended purpose as described in this user manual.
  • To avoid physical injury, do not direct the spray under the tongue or into the ear, nose, eye or other sensitive area.
  • Do not clean the AirFloss nozzle, the handle, the charger, the water reservoir and its cover in the dishwasher or a microwave.
  • To avoid an ingestion hazard, do not put isopropyl alcohol or other cleaning fluids in the reservoir.
  • The AirFloss is a personal care device and is not intended for use on multiple patients in a dental practice or institution.

Electromagnetic fields (EMF)

This Philips appliance complies with all applicable standards and regulations regarding exposure to electromagnetic fields.

General description (Fig. 1)

1 Guidance tip
2 AirFloss nozzle
3 Activation button
4 Reservoir and cover
5 Handle
6 Charge indicator
7 Power on/off button
8 Removable nozzle holder (specific types only)
9 Charger

Note: The contents of the box may vary based on the model purchased.

Charging

Charge the AirFloss for 24 hours before first use.

1 Put the plug of the charger in the wall socket (Fig. 2).
2 Place the handle on the charger (Fig. 3).

The charge indicator flashes green to indicate that the appliance is charging (Fig. 4).

Note: When it is fully charged, the AirFloss has an operating time of up to 2 weeks (or 14 uses).

Note: When the charge indicator flashes yellow, the battery is low and needs to be recharged (fewer than 3 uses left).

Preparing for use

1 Align the nozzle so the tip faces the front of the handle and press the nozzle down onto the handle ('click') (Fig. 5).

Note: Replace the nozzle every 6 months for optimal results. Also replace the nozzle if it becomes loose or no longer clicks onto the handle.

2 Open the cover of the reservoir ('click') (Fig. 6).
3 Fill the reservoir with mouthwash or water (Fig. 7).

Note: To operate effectively, the AirFloss has to contain either mouthwash or water.

Tip: For a fresher experience, use mouthwash instead of water.

Note: Do not use mouthwash that contains isopropyl myristate (e.g. Dentyl Active) or high concentrations of essentials oils, as it may damage the appliance. This includes all mouthwash sold in glass and ceramic packaging.

4 Close the cover of the reservoir ('click') (Fig. 8).
5 Press the on/off button (Fig. 9).

The green charge indicator lights up.

6 Press and hold the activation button until spray comes out of the tip of the nozzle (Fig. 10).

Using the appliance

1 Make sure the AirFloss is switched on (Fig. 9).
2 Place the tip between the teeth and apply gentle pressure. Slightly close your lips over the nozzle when it is in place, to avoid splashing (Fig. 11).

Tip: Use your finger to press the activation button.

Note: The AirFloss is intended to be used on the front/outside surface of the teeth only.

3 Press the activation button to deliver a single burst of air and micro-droplets of mouthwash or water between the teeth. Alternatively, hold the activation button to deliver continuous bursts of mouthwash or water approximately every 1 second (select models) (Fig. 12).

4 Slide the guidance tip along the gum line until you feel it settle between the next two teeth.

5 Continue this procedure for all spaces including behind your back teeth (Fig. 13).

6 To switch off the AirFloss, press the on/off button again.

Automatic shut-off function

The automatic shut-off function automatically switches off the AirFloss if it has not been used for 4 minutes.

Cleaning

Do not clean the nozzle, handle or charger in the dishwasher.

Do not use cleaning agents to clean the appliance.

Handle and nozzle

1 Remove the nozzle from the handle. Rinse the nozzle after each use (Fig. 14).
2 Open the reservoir and rinse it under the tap to eliminate residue (Fig. 15).
Tip: You can also use a cotton bud to wipe the reservoir.

Note: Do not immerse the handle in water.

3 Wipe the entire surface of the handle with a damp cloth (Fig. 16). Charger

1 Unplug the charger before you clean it (Fig. 17).
2 Wipe the surface of the charger with a damp cloth (Fig. 18).

Storage

If you are not going to use the AirFloss for an extended period of time, follow the steps below.

1 Open the cover of the reservoir and empty the reservoir.
2 Press the activation button until no more spray comes out of the nozzle.
3 Unplug the charger (Fig. 17).
4 Clean the AirFloss nozzle, handle and charger.
5 Store the AirFloss in a cool, dry place away from direct sunlight.

Ordering accessories

To buy accessories or spare parts, visit www.shop.philips.com/service or go to your Philips dealer. You can also contact the Philips Consumer Care Centre in your country (see the worldwide guarantee leaflet for contact details).

Recycling

  • This symbol on a product means that the product is covered by European Directive 2012/19/EU (Fig. 19).
  • This symbol means that the product contains a built-in rechargeable battery covered by European Directive 2006/66/EC which cannot be disposed of with normal household waste. Follow the instructions in section ‘Removing the rechargeable battery’ to remove the battery (Fig. 20).
  • Inform yourself about the local separate collection system for electrical and electronic products and rechargeable batteries. Follow local rules and never dispose of the product and rechargeable batteries with normal household waste. Correct disposal of old products and rechargeable batteries helps prevent negative consequences for the environment and human health.

Removing the rechargeable battery

Please note that this process is not reversible.

1 To deplete the battery, repeatedly press the activation button until the AirFloss no longer produces any bursts of air (Fig. 21).
2 Use a screwdriver to pry open the handle (Fig. 22).
3 Cut the wires and remove the battery from the appliance. Observe basic safety precautions (Fig. 23).

Guarantee and support

If you need information or support, please visit www.philips.com/sonicare or read the separate worldwide guarantee leaflet.

Guarantee restrictions

The terms of the international guarantee do not cover the following:

  • AirFloss nozzle.
  • Damage caused by misuse, abuse, neglect, alterations or unauthorised repair.
  • Normal wear and tear, including chips, scratches, abrasions, discolouration or fading.

Einführung

Encomendar acessórios

natural_image Diagram of a folded paper or document with two panels, each showing an open page and a black arrow indicating direction (no text or symbols present)

PHILIPS

www.philips.com/Sonicare

©2015 Koninklijke Philips N.V. (KPNV). All rights reserved.

Philips and the Philips shield are trademarks of KPNV.

AirFloss, Sonicare and the Sonicare logo are trademarks of Philips Oral Healthcare, Inc. and/or KPNV.

PHILIPS Sonicare AirFloss HX8212 - Encomendar acessórios - 2

100% recycled paper

100% papier recyclé

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : PHILIPS

Model : Sonicare AirFloss HX8212

Category : Interdental brush