Burg Wächter TRSE 6000 - Safe

TRSE 6000 - Safe Burg Wächter - Free user manual and instructions

Find the device manual for free TRSE 6000 Burg Wächter in PDF.

📄 44 pages English EN 💬 AI Question ⚙️ Specs
Notice Burg Wächter TRSE 6000 - page 12
View the manual : Français FR Deutsch DE English EN Nederlands NL
SKIP

Frequently Asked Questions - TRSE 6000 Burg Wächter

User questions about TRSE 6000 Burg Wächter

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

L'email reste privé : il sert seulement à vous prévenir si quelqu'un répond à votre question.

No questions yet. Be the first to ask one.

Download the instructions for your Safe in PDF format for free! Find your manual TRSE 6000 - Burg Wächter and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. TRSE 6000 by Burg Wächter.

USER MANUAL TRSE 6000 Burg Wächter

Low Power 2.4 GHz Transceiver

Maximum Transmit Output Power 1dBm

Frequency usage range 2,400GHz ... 2,4835 GHz ISM/SRD band system

Priorität:

Thank you for deciding for a safe with the BURG-WACHTER TRSE 6000 electronics. This electronics is VdS-certified for class B. You have acquired a product meeting extremely high security requirements and developed and manufactured using the latest technical potential.

Please read the entire User Manual before programming and store it at a safe place for future reference.

The TRSE 6000 electronics is available in a TRSE 6000 FP version with a fingerscan unit and in another version TRSE 6000 without the fingerscan unit. The present user manual applies to both versions, however, the menu structure is able to detect automatically the appropriate version and thus only the menu items intended for it are active. The items relevant only for the electronics with a fingerscan unit are marked with*.

Generally, you can open the safe in three possible ways:

with a code
with an E-Key (ident medium TSE 5103 E-Key SB and TSE 6103 E-Key not included in the delivery)
with your fingerprint*

The administrator code when delivered from the factory is 123456. This code must be changed. Additional 9 users with a code to be entered by the keyboard can be defined. Such code has always six digits, similarly to administrator's code.

Additionally, up to 300 E-Keys for contactless opening can be stored.

In case you possess a safe with a fingerscan unit, up to 10 users with fingerscan can be additionally stored. Users with fingerscan are identified in the user list of the lock as USER xxx_FP.

The TRSE 6000 FP electronics is the first safe electronics, for which the opening based on fingerscan is certified.

At least two opening codes shall be entered to open the safe using fingerprint. Another opening code must be entered in addition to fingerscan. This can be either another fingerscan, but also a pin code or an E-Key. All the fingerprints are stored in the system with a value of 12 . In order to acquire the authorization to open, a value of at least 1 must be achieved. A pin code with a value of at least 12 must be therefore entered for the opening, a value of 1 can be also achieved with an additional fingerscan.

Attention: The values can only be adjusted using TSE Light, TSE System and System + software. When a PIN code user or an E-Key user is being created for the safe, an inquiry is made on whether the opening code shall be used together with a fingerprint. Correspondingly, the value is then automatically set to 12 . Otherwise the PIN code and the E-Key are assigned values of 1, the fingerscan is always assigned a value of 12 .

Blocking times: To protect the lock against manipulation the electronics block the access to the safe for 5 minutes if 3 incorrect pincodes have been entered one after another. With every following wrong pincode for 10 minutes. During this period, the display shows the remaining countdown time. Opening the safe is also not possible with a valid user or administrator code.

In order to enhance the protection against intrusion, the following points should be observed:

For locking systems with material code carriers, e. g. an E-Key:

  • The code carrier should be consistently stored safely, so that it is accessible only to the authorized persons.
    In case of a loss of the code carrier, the lock should be immediately replaced or converted to a new combination by changing the coding, and / or the code of the lost code carrier should be blocked / deleted.

For locking systems requiring a code:

General information: please take care that the codes and the code carrier do not fall into the wrong hands. Therefore, store the codes and code carrier at a safe location so that these can only be accessed by authorised persons. In case you lose a code or code carrier, the lock must be converted to a new code / code carrier, or replaced.

  • The factory code must be changed as soon as the lock is commissioned.
  • Simple codes that are easy to guess (e.g. 1, 2, 3, 4, 5, 6) must not be used.
  • Personal data (e.g. birthday) or other data that may be concluded with knowledge of the code owner must not be used as code.
  • After changing the code, the lock must be checked several times with the safety door opened.
  • Attention: Any changes of the administrator code and of the user codes shall be made with the safe door opened!
  • When the locking system has been reset to another code, this new code should be repeatedly used with the safe door opened.

2.1 Description of basic functions

You can program your lock based on the following description.

You can see the programming instructions on the display. To program the lock (enter into the menu), please press the "Function" key, when the symbol "M" is displayed. You can move within the menu using the keys "1" scroll up (symbol on display) and "2" scroll down (symbol on display). When the symbol "<" is displayed, you can use the "Function" key to skip to the next higher menu level, and choose a particular menu item using the "Enter /

On" key. The battery symbol indicates the current battery status:

Battery full

[B] [] [B] Battery empty (please replace the batteries)

Battery replacement page 42

2.2 Description of programming and user mode

Please find the menu structure shown on the following pages. Also the navigation is indicated. Additionally, each of the menu items is clarified:

Code change menu

Change of the administrator and user codes

Language/ Sprache menu

Language setup

E-Key synchronization menu

In this program, the channel of the E-Key is adapted to the channel of the input unit.

This function is necessary when the radio channel of an input unit is modified, although other radio keys (with the old channel setup) are still logged.

Info menu

  • Indication of version and serial number
  • SNA: Lock serial number (via type in the Administration code)

Administrator menu

This includes all the menus that can be used only with the administrator authorizations. They include:

Create User:

Users can be created here. A user has either a code, or an E-Key, or both. A separate user is always created for a fingerscan.

Anatomically, there are people, the fingerprints of whom are not sufficiently articulated for the system.

Assign E-Key:

An E-Key can be additionally assigned to a selected user here.

- Delete:

Users and E-Keys can be deleted here. When a user is deleted, also the code and the E-Key belonging to the user are deleted. When an E-Key is deleted, the user is retained. To delete a fingerscan, the corresponding user has to be deleted. To delete all the fingerscans, please use the "FS-Reset" function (see below).*

Time:

Entry of the time and calibration of the clock. The clock is automatically calibrated between two specific times. Exceptions are a replacement of batteries and the switchover from summer to winter time.

Date:

Entry of date

Radio Channel:

The radio channel can be set up here (12 channels to select from). This can be required when the radio channel is already used by another application, e. g. WLAN. In case of collision with WLAN systems, a space of three channels is recommended.

Low Power 2.4 GHz Transceiver

Maximum Transmit Output Power 1dBm

Frequency usage range 2,400GHz ... 2,4835 GHz ISM/SRD band system

Priority:

In case the door cannot be opened after several attempts with the E-Key, the priority of the door can be increased by this function. Inversely, also the priority of other door within the direct environment can be reduced.

Restructure:

The use of this function is recommended when several users have been deleted.

Register:

When either the lock unit or the keyboard is replaced, the two units are newly tuned to each other.

FS-Reset*:

All the stored fingerprints are deleted, however, the corresponding users are retained. Please select this menu and follow the instructions on the display also in case of repeated error functions related to the use of fingerprints. These fingers could not be stored because of security reasons.

2.3 Menu structure

Burg Wächter TRSE 6000 - Menu structure - 1

Burg Wächter TRSE 6000 - Menu structure - 2
Display Input

Burg Wächter TRSE 6000 - Menu structure - 3
Administrator User
E=Enter

Burg Wächter TRSE 6000 - Menu structure - 4

2.4 Detailed description of selected basic functions

1. Opening the safe using the factory code

  • Press the On/Enter key
  • The Code/Fingerp indication is displayed (in case you possess electronics without fingerscan, Code is displayed instead.)
  • At this point you are asked to enter the Admin. Code (factory setting 123456)
  • The instruction Please turn knob is displayed

Attention: The message Please turn knob implies the action with the knob of the locking unit, for which the opening code has been entered.

2. Changing the Administrator Code

  • Press the On/Enter key
    The indication of Code/Fingerp is displayed
  • Press the Function key
    -TheChange code menu is displayed
    Press the On/Enter key
    The indication of Administrator is displayed
  • Press the On/Enter key
    The indication of the Old code is displayed
  • At this point you are asked to enter the Admin.

Code (factory setting 123456)

Press the On/Enter key
The indication of the New code is displayed
Enter the new code
Press the On/Enter key
The indication of Repeat code is displayed
Enter the new code
Press the On/Enter key
The indication of Code successfully changed is displayed

3. Creating a user with a code

  • Press the On/Enter key
    The indication of Code/Fingerp is displayed
  • Press the Function key
    -TheChange code menu is displayed
  • By pressing the key 2 reach the Administrator menu
  • Press the On/Enter key
  • Admin setup Create user is displayed
    Press the On/Enter key
  • Createcode is displayed
    Press the On/Enter key
  • At this point you are asked to enter the Admin. Code (factory setting 123456)
    The indication of User 00x is displayed
  • Please enter the user code and confirm it with ENTER
  • Press the On/Enter key
  • FS combination to be confirmed with ENTER is displayed
  • Press the On/Enter key and accordingly the Function key
    After confirmation, Save with the On key is displayed.

4. Creating a user with an E-Key

  • Press the On/Enter key
    The indication of Code/Fingerp is displayed
  • Press the Function key
  • The Change code menu is displayed
  • By pressing the key 2 reach the Administrator menu
  • Press the On/Enter key
    Admin setup Create user is displayed
  • Press the On/Enter key
    CreateE-Key is displayed
    Press the On/Enter key
  • At this point you are asked to enter the admin. Code (factory setting 123456)
  • FS combination to be confirmed with ENTER is displayed
    Press the On / Enter key and accordingly the Function key
    -User 00xStore E-Key using ENTER is displayed
  • Please bring the E-Key in the programming mode.
    Press the On/Enter key
  • E-Key in Prog mode, continue with Enter is displayed
    Press the On/Enter key
    After confirmation, Save with the On key is displayed

If the message FS combination to be confirmed with ENTER is displayed you have to decide whether the user should get the full opening right or half of it.

Full opening right: press Function key

Half opening right: press ENTER key

If you create a half opening right the Pin code is only to be allowed to open with another opening secret e. g. the fingerprint.

5. Storing a user with fingerprint*

  • Press the On/Enter key
    The indication of Code/Fingerp is displayed
  • Press the Function key
  • The Change code menu is displayed
  • By pressing the key 2 reach the Administrator menu
  • Press the On/Enter key
  • Admin setup Create user is displayed
  • Press the On/Enter key
  • By pressing the key 2 several times reach the Create fingerscan menu
    Press the Function key
  • At this point you are asked to enter the admin. Code (factory setting 123456)
    The indication of Create fingerscan is displayed
  • The indication of Store finger is displayed
  • Please pull your finger over the sensor for several times according to the instructions shown on the display
  • After a successful entry the indication User xxx successfully created is displayed

Attention: When saving a fingerprint it is important that the finger is laid evenly and in a straight position over the sensor. Follow the instructions on the display. The finger is saved only when it can be read in an optimum quality.

6. Opening with fingerprint*

  • Press the On/Enter key
    The indication of Code/Fingerp is displayed
  • Move the saved finger over the sensor
    Value not achieved is displayed for a short time
    TheCode/Fingerp indication is displayed
  • At this point, enter an additional opening code.
    The instruction Please turn knob is displayed

7. Deleting a finger*

  • Press the On/Enter key
    The indication of Code/Fingerp is displayed
    Press the Function key
  • The Change code menu is displayed
  • By pressing the key 2 reach the Administrator menu
  • Press the On/Enter key
  • Admin setup Create user is displayed
  • By pressing the key 2 reach the Admin. setup Delete menu
    Press the On/Enter key
  • Delete user is displayed
    Press the On/Enter key
  • At this point you are asked to enter the admin. Code (factory setting 123456)
  • Now you have to select the appropriate user by pressing the keys 1 or 2
    Press the On/Enter key
  • The indication of Delete data to be confirmed with the On key is displayed.
  • Press the On/Enter key
    The indication of Data record deleted is displayed

Additional users can be deleted using the On/Enter key. By pressing the Function key, you can reach higher menu levels up to the code entry.

2.5 Error messages*

The following error messages are indicated when a finger is being saved or the safe opened:

Error message Elimination of causes
too fast!please repeatMove the finger more slowly over the sensor
too aslant!please repeatMove the finger straight over the sensor
too short!please repeatMove the finger over the sensor in a way allowing more surface area to be rea
place to the center and repeat!Place your finger centrally over the sensor

Disposal

Dear customer,

Please help us avoid unnecessary waste.

Should you intend to dispose of this device at any time, please remember that many components of this device contain valuable materials, which can be recycled.

Burg Wächter TRSE 6000 - Dear customer, - 1

Please be aware that electrical and electronic equipment and batteries shall not be disposed of as household waste, but rather collected separately. Please obtain information on the collecting points for electrical waste from the responsible authority of you municipality.

Burg Wächter TRSE 6000 - Dear customer, - 2

BURG-WACHTER KG hereby declares that this device complies with Directive 2014/53/EU, (RED) 2014/30/EU, (EMC) and 2011/65/EU (RoHS). The full text of the EU Declaration of Conformity can be found on the following website

www.burg.biz

3 Généralités

Low Power 2.4 GHz Transceiver

Maximum Transmit Output Power 1dBm

Frequency usage range 2,400GHz ... 2,4835 GHz ISM/SRD band system

Priorite:

Low Power 2.4 GHz Transceiver

Maximum Transmit Output Power 1dBm

Frequency usage range 2,400GHz ... 2,4835 GHz ISM/SRD band system

Prioriteit:

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Burg Wächter

Model : TRSE 6000

Category : Safe