Product type Window thermometer/hygrometer
Brand TECHNOLINE
Model WS 7025
Temperature range -20 °C to 60 °C (-4 °F to 140 °F)
Temperature accuracy ±1.0 °C (±1.8 °F)
Humidity range 20% to 95%
Humidity accuracy ±5% (30% to 90%); ±7% (20% to 29% and 91% to 95%)
Unit selection Celsius or Fahrenheit (mechanical selector)
Power supply 1 button cell LR44 or AG13
Mounting Suction cup (smooth, clean surfaces)
Usage Indoor or outdoor (convertible configuration)
Configuration conversion 180° rotation of lower housing and suction cup
Usage precautions Do not expose to shocks, extreme temperatures, excessive humidity; do not immerse; do not open the housing
Cleaning Clean with a soft, dry cloth; do not use corrosive products
Recycling Do not dispose of with household waste; take to an appropriate collection point

Frequently Asked Questions - WS 7025 TECHNOLINE

How to insert batteries in the WS 7025 thermometer?
Remove the lower part of the housing and the battery holder. Insert an LR44 or AG13 battery respecting polarity. Close the housing.
How to switch from Celsius to Fahrenheit?
A mechanical selector allows choosing between Celsius and Fahrenheit. Open the housing to access it when inserting batteries.
Can the thermometer be used outdoors?
Yes, it is delivered in outdoor configuration with a suction cup. You can attach it to a window or smooth surface. For indoor use, you need to convert the housing.
How to convert the thermometer for indoor use?
Remove the lower housing, take off the suction cup, turn the lower housing and suction cup 180 degrees, then reassemble.
What are the temperature and humidity accuracies?
Temperature: ±1.0 °C. Humidity: ±5% between 30% and 90%, ±7% outside this range.
On which surfaces does the suction cup stick?
The suction cup adheres to smooth, clean surfaces like glass or mirrors. It does not stick to wood or plaster.
What to do if the display remains blank?
Check that the battery is correctly inserted and in good condition. Replace it if necessary.
How to clean the thermometer?
Use a soft, dry cloth. Avoid contact with water or corrosive chemicals.
What safety precautions should I observe?
Do not expose the device to shocks, extreme temperatures, excessive humidity. Do not immerse it and do not open the housing. Use only alkaline batteries.
How to recycle the thermometer at end of life?
Do not dispose of it with household waste. Take it to an electrical waste collection point or recycling center.

User questions about WS 7025 TECHNOLINE

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Thermometer in PDF format for free! Find your manual WS 7025 - TECHNOLINE and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. WS 7025 by TECHNOLINE.

USER MANUAL WS 7025 TECHNOLINE

Battery Installation and C/F selection

(See above illustrations 1~2)

  • Pull the bottom housing and battery holder away from the top housing.
  • Insert the battery according to the polarity markings.

  • Slide the selector switch to either Fahrenheit or Celsius.

  • Re-attach the top and bottom housings.

Convert from Outdoor to Indoor Use (See above illustrations 3~6)

Your suction cup thermometer is assembled for outdoor use. If you want to attach the thermometer to the inside of the window, follow these steps:

  • Pull the bottom housing away from the top housing.
  • Pull the suction cup away from the top housing.
  • Rotate the bottom housing and suction cup 180 degrees.
  • Push the suction cup into place.
  • Re-attach the top and bottom housings.

Install the Thermometer

The thermometer can be mounted to a window, mirror, or nay clean and smooth, non-porous surface. Suction cups will not hold on wood or plaster.

  • Clean surface of any oils or other foreign matter.
  • To attach the thermometer, press firmly the suction cup attaches to the housings, making sure the suction cup makes a tight bond with the mounting surface.

Do not use in direct rain and direct sunlight.

Specifications

  • Temperature range: -4^ to 140^ (-20°C to 60°C)
  • Temperature tolerance: +/- 1.8^ (+/- 1.0^)
  • ^ C / ^ F selectable
    Hygrometer range: 20% to 95%
    Hygrometer tolerance: + / - 5% at 30 % to 90% ; + / - 7% at 20% to 29% and 91% to 95%
  • Uses (1) LR44 or AG13 button cell battery

Precautions

  • This main unit is intended to be used only indoors.
  • Do not subject the unit to excessive force or shock.
  • Do not expose the unit to extreme temperatures, direct sunlight, dust or humidity.
  • Do not immerse in water.
  • Avoid contact with any corrosive materials.
  • Do not dispose this unit in a fire as it may explode.
  • Do not open the inner back case or tamper with any components of this unit.

Batteries safety warnings

  • Use only alkaline batteries, not rechargeable batteries.
  • Install batteries correctly by matching the polarities (+/-) .
  • Always replace a complete set of batteries.
  • Never mix used and new batteries.
  • Remove exhausted batteries immediately.
  • Remove batteries when not in use.
  • Do not recharge and do not dispose of batteries in fire as the batteries

may explode.

  • Ensure batteries are stored away from metal objects as contact may cause a short circuit.
  • Avoid exposing batteries to extreme temperature or humidity or direct sunlight.
  • Keep all batteries out of reach from children. They are a choking hazard.

Use the product only for its intended purpose!

Consideration of duty according to the battery law

TECHNOLINE WS 7025 - Consideration of duty according to the battery law - 1

Old batteries do not belong to domestic waste because they could cause damages of health and environment. You can return used batteries free of charge to your dealer and

collection points. As end-user you are committed by law to bring back needed batteries to distributors and other collecting points!

Consideration of duty according to the law of electrical devices

TECHNOLINE WS 7025 - Consideration of duty according to the law of electrical devices - 1

This symbol means that you must dispose of electrical devices separated from the General household waste when it reaches the end of its useful life. Take your unit to your local waste collection point or recycling centre. This applies to all