Product type Extractor hood
Brand FRANKE
Model SIRIO FDS 954 XS
Installation Telescopic chimney, wall mounting
Minimum safety distance 650 mm above the cooking surface
Air outlet diameter 120 mm or 150 mm (with reducer supplied)
Functions 3 suction speeds (V1 silent, V2 medium, V3 maximum), lighting
Lighting Incandescent lamp 40 W
Grease filters Metal, dishwasher-safe (every 2 months)
Odor filters Activated carbon, replacement every 4 months (recirculation mode)
Electrical supply Mains with bipolar switch (contact opening ≥ 3 mm)
Use Domestic, removal of cooking odors
Surface maintenance Damp cloth and neutral liquid detergent
Included spare parts Reducing flange Ø 150-120 mm, air outlet connector, clamps, screws, wall plugs

Frequently Asked Questions - SIRIO FDS 954 XS FRANKE

What is the minimum distance between the hood and the hob?
The minimum safety distance is 650 mm between the hob and the hood.
How to clean the metal grease filters?
The metal grease filters are dishwasher-safe. It is recommended to wash them approximately every 2 months of use, or more frequently with heavy use. After washing, let them dry before reinstalling, ensuring the handle remains visible.
How to replace the activated carbon filters?
First remove the metal grease filters. Then remove the saturated charcoal filters (A) and mount the new ones (B). Reassemble the metal filters. The charcoal filters must be replaced at least every 4 months, or more frequently with heavy use.
How to install the hood in extraction mode?
Connect the hood to the outlet ducting using a rigid or flexible pipe of diameter 150 mm or 120 mm. If using a 120 mm pipe, insert the supplied reducing flange onto the hood outlet. Secure the pipe with clamps (not supplied). Remove any charcoal filters.
How to install the hood in recirculation mode?
Press the supplied air outlet connector onto the hood body outlet. Ensure the activated carbon odor filters are in place.
What to do if the hood does not work?
First check that the hood is properly plugged in and that the bipolar switch is activated. Ensure the power cable connector is well plugged into the diffuser socket. If the problem persists, contact a professional.
How to change the hood bulb?
Remove the metal grease filters. Unscrew the incandescent bulbs of 40 W and replace them with new ones of the same specifications. Reassemble the metal filters.
Can I use the hood with gas appliances?
Yes, but you must provide sufficient room ventilation. If the kitchen has no external opening, create an opening communicating with the outside to ensure fresh air inflow. Never connect the hood to combustion fume exhaust ducts (boiler, chimney, etc.).
What is the replacement period for charcoal filters?
The charcoal filters must be replaced at least every 4 months of use, or more frequently with heavy use. They are neither washable nor reusable.
How to electrically connect the hood?
Connect the hood to the mains by inserting a bipolar switch with contact opening of at least 3 mm. Before any maintenance operation, disconnect the hood or activate the main switch.

User questions about SIRIO FDS 954 XS FRANKE

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Home Appliances in PDF format for free! Find your manual SIRIO FDS 954 XS - FRANKE and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. SIRIO FDS 954 XS by FRANKE.

USER MANUAL SIRIO FDS 954 XS FRANKE

Instructions Manual INDEX

RECOMMENDATIONS AND SUGGESTIONS 14
CHARACTERISTICS 15
INSTALLATION 16
USE 19
MAINTENANCE 20

  • The manufacturer will not be held liable for any damages resulting from incorrect or improper installation.
  • The minimum safety distance between the cooker top and the extractor hood is 650~mm .
  • Check that the mains voltage corresponds to that indicated on the rating plate fixed to the inside of the hood.
  • For Class I appliances, check that the domestic power supply guarantees adequate earthing.

Connect the extractor to the exhaust flue through a pipe of minimum diameter 120 ~mm . The route of the flue must be as short as possible.

  • Do not connect the extractor hood to exhaust ducts carrying combustion fumes (boilers, fireplaces, etc.).
  • If the extractor is used in conjunction with non-electrical appliances (e.g. gas burning appliances), a sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas. The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air.

USE

  • The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells.
  • Never use the hood for purposes other than for which it has been designed.
  • Never leave high naked flames under the hood when it is in operation.
  • Adjust the flame intensity to direct it onto the bottom of the pan only, making sure that it does not engulf the sides.
  • Deep fat fryers must be continuously monitored during use: overheated oil can burst into flames.
  • Do not flambe under the range hood; risk of fire
  • The hood should not be used by children or persons not instructed in its correct use.

MAINTENANCE

  • Switch off or unplug the appliance from the mains supply before carrying out any maintenance work.
  • Clean and/or replace the Filters after the specified time period.
  • Clean the hood using a damp cloth and a neutral liquid detergent.

FRANKE SIRIO FDS 954 XS - MAINTENANCE - 1

FRANKE SIRIO FDS 954 XS - MAINTENANCE - 2

FRANKE SIRIO FDS 954 XS - MAINTENANCE - 3

Dimensions

FRANKE SIRIO FDS 954 XS - Dimensions - 1

Components

Ref.Q.tyProduct Components
11Hood Body, complete with: Controls, Light, Blower, Filters
21Telescopic Chimney comprising:
2.11Upper Section
2.21Lower Section
91Reducer Flange ø 150-120 mm
151Air Outlet Connection
Ref.Q.tyInstallation Components
7.12Hood Body Fixing Brackets
7.2.12Upper Chimney Section Fixing Brackets
118Wall Plugs
12a8Screws 4.2 x 44,4
12c6Screws 2.9 x 9.5
12d2Screws M4 x 25

Q.ty Documentation

1 Instruction Manual

FRANKE SIRIO FDS 954 XS - Dimensions - 2

Wall drilling and bracket fixing

FRANKE SIRIO FDS 954 XS - Wall drilling and bracket fixing - 1

Wall marking:

  • Draw a vertical line on the supporting wall up to the ceiling, or as high as practical, at the centre of the area in which the hood will be installed.
  • Draw a horizontal line at 650mm above the hob for installation without the back panel, or at height H (H=height of the visible part of the panel) for installation with the back panel.
  • Place bracket 7.2.1 on the wall as shown about 1 - 2mm from the ceiling or upper limit aligning the centre (notch) with the vertical reference line.
  • Mark the wall at the centres of the holes in the bracket.
  • Place bracket 7.2.1 on the wall as shown at X mm below the first bracket ( X = height of the upper chimney section supplied), aligning the centre (notch) with the vertical line.
  • Mark the wall at the centres of the holes in the bracket.
  • Place bracket 7.1 as shown 95mm from the vertical reference line and 210mm above the horizontal reference line.
  • Mark the centres of the holes in the bracket.
  • Repeat this operation on the other side.

REAR PANEL (OPTIONAL)

The Rear Panel must be fitted before fixing the hood body and, if it is to be fixed at both top and bottom, must be fitted at the correct height prior to installing the bases. As this operation is rather complex, it should be carried out either by the kitchen installer or a qualified person who knows the final dimensions of the units.

For fixing at the top only, proceed as follows:

  • Rest the back panel on the base, inserting the lower plate between the upper surface and the wall, centring it on the vertical reference line.
  • Mark the centres of the two holes in the upper plate.
  • Drill 8mm holes at all the centre points marked.
  • Insert the wall plugs 11 in the holes.
    Fix the brackets using the 12a screws (4,2 x 44,4) supplied.
    Fix the back panel (where present) using the 12a (4,2× 44,4) screws supplied.

Mounting the hood body

  • Screw the two screws 12d supplied onto the brackets 7.1.
  • Hook the hood body onto the bracket 7.1, centring it around the vertical line.
  • Use the adjusting screws 12d underneath the hood to level the hood body.

FRANKE SIRIO FDS 954 XS - Mounting the hood body - 1

Connections

DUCTED VERSION AIR EXHAUST SYSTEM

When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe 150 or 120~mm , the choice of which is left to the installer.

  • To install a 120mm air exhaust connection, insert the reducer flange 9 on the hood body outlet.
    Fix the pipe in position using sufficient pipe clamps (not supplied).
  • Remove any activated charcoal filters.

FRANKE SIRIO FDS 954 XS - DUCTED VERSION AIR EXHAUST SYSTEM - 1

RECIRCULATION VERSION AIR OUTLET

  • Push fit the air outlet fitting 15 onto the air outlet of the hood body.
  • Ensure that the activated charcoal filters have been inserted.

FRANKE SIRIO FDS 954 XS - RECIRCULATION VERSION AIR OUTLET - 1

ELECTRICAL CONNECTION

  • Connect the hood to the mains through a two-pole switch having a contact gap of at least 3mm .
  • Remove the grease filters (see paragraph Maintenance) being sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan.

FRANKE SIRIO FDS 954 XS - ELECTRICAL CONNECTION - 1

Flue assembly

Upper exhaust flue

  • Slightly widen the two sides of the upper flue and hook them behind the brackets 7.2.1, making sure that they are well seated.
  • Secure the sides to the brackets using the 4 screws 12c( 2,9 × 9,5) supplied.

Lower exhaust flue

  • Slightly widen the two sides of the flue and hook them between the upper flue and the wall, making sure that they are well seated.
    Fix the lower part laterally to the hood body using the 2 screws 12c (2,9 x 9,5) supplied.
  • Make sure that the air outlet connection is aligned with the chimney outlets.

FRANKE SIRIO FDS 954 XS - Lower exhaust flue - 1

FRANKE SIRIO FDS 954 XS - Lower exhaust flue - 2

LLightSwitches the lighting system on and off.
SLedMotor running led.
V1MotorSwitches the extractor motor on and off at low speed. Used to provide a contin-uos and silent air change in the presence of light cooking vapours.
V2SpeedMedium speed, suitable for most operating conditions given the optimum treated air floss/noise level ratio.
V3IntensiveMaximum speed, used for eliminating the highest cooking vapour emission, including long periods.

Grease filters

CLEANING METAL SELF- SUPPORTING GREASE FILTERS

  • The filters must be cleaned every 2 months of operation, or more frequently for particularly heavy usage, and can be washed in a dishwasher.
  • Remove the filters one at a time by pushing them towards the back of the group and pulling down at the same time.
  • Wash the filters, taking care not to bend them. Allow them to dry before refitting.
  • When refitting the filters, make sure that the handle is visible on the outside.

FRANKE SIRIO FDS 954 XS - CLEANING METAL SELF- SUPPORTING GREASE FILTERS - 1

Activated charcoal filter (Recirculation version)

These filters are not washable and cannot be regenerated, and must be replaced approximately every 4 months of operation, or more frequently with heavy usage.

REPLACING THE ACTIVATED CHARCOAL FILTER

  • Remove the metal grease filters
  • Remove the saturated activated charcoal filter as shown (A).
  • Fit the new filters (B).
  • Replace the metal grease filters.

FRANKE SIRIO FDS 954 XS - REPLACING THE ACTIVATED CHARCOAL FILTER - 1

Lighting

LIGHT REPLACEMENT

40 W incandescent light.

  • Remove the metal grease filters.
  • Unscrew the bulbs and replace them with new ones having the same characteristics.
  • Replace the metal grease filters.

FRANKE SIRIO FDS 954 XS - W incandescent light. - 1

INSTALLATION

FIXATION EMBASE (SI FOURNIE)

REEMPLACEMENT LAMPES

RÜCKWANDPANEL (OPTION)

The symbol on the product or on its packaging indicates that this product may not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. For more detailed information about recycling of this product, please contact your local city office, your household waste disposal service or the shop where you purchased the product.