Input voltage 12 V DC
Output voltage 210 – 230 V AC
Output frequency 50 Hz ± 2 Hz
Continuous power 150 W
Peak power 350 W
Dimensions (L x W x H) 167 x 129 x 71 mm
Weight 800 g
Power supply 12 V battery (cigarette lighter socket)
Fuse Internal, replaceable with fuse of same specification
Protections Thermal, overload, undervoltage (10 V), overvoltage (15.3 V)
Undervoltage alarm Activates at 10.8 V
Cooling Housing and fan
Ambient temperature 0 °C – 50 °C
Certifications CE E24
Connection 12 V socket with connection cable
Maintenance Cleaning with a damp cloth
Safety Do not cover vents, do not use near flammable gases, do not connect multiple consumers
Intended use Converts 12 V DC to 230 V AC for devices up to 150 W continuous
Warranty Legal, contact WAECO or dealer

Frequently Asked Questions - PP152 DOMETIC

What is the maximum power of the PP152 inverter?
The maximum continuous power is 150 watts and the peak power is 350 watts. Devices requiring more power must not be connected.
Can I plug a refrigerator into this inverter?
Yes, but note that devices with electric drives (such as a refrigerator) often use more power than indicated on the nameplate during startup. Check that the starting power does not exceed 350 W.
How to install and mount the inverter?
Mount the inverter using the four supplied brackets. Choose a stable, dry, well-ventilated place, protected from dust and flammable materials. Leave at least 25 cm of free space around the device. Do not install in an engine compartment or exposed to direct sunlight.
What to do if the inverter stops during use?
Several possible causes: thermal overload (let it cool down and improve ventilation), undervoltage of the battery (charge the battery or start the engine), defective fuse (replace with a fuse of the same specification), or defective device (replace it).
How to change the inverter fuse?
Remove the defective fuse from the socket located at the rear of the device (fig. 2 3, page 4). Install a new fuse of the same specifications. Do not use a fuse of a different rating.
What battery should I use with the PP152?
The PP152 operates with a 12 V DC battery. The nominal input voltage is 12 V. Make sure the battery can supply at least 15 A (permissible load of the socket, line and fuses).
Can I use the inverter with the engine off?
Yes, the inverter can be used whether the engine is running or off. However, for extended use with a high load, it is advisable to start the engine to recharge the vehicle battery.
How to clean the inverter?
Occasionally clean the device with a damp cloth. Do not use any sharp or hard objects that could damage it.
What to do in case of inverter overheating?
The inverter automatically shuts off and the red malfunction LED lights up. Turn off the inverter using the switch. After cooling down (ensure sufficient ventilation), you can turn it back on.
What is the warranty of the PP152 inverter?
The legal warranty period applies. In case of a defect, send the device to the WAECO branch in your country or to your specialist dealer, accompanied by a copy of the dated invoice and a description of the malfunction.

User questions about PP152 DOMETIC

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Power inverter in PDF format for free! Find your manual PP152 - DOMETIC and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. PP152 by DOMETIC.

USER MANUAL PP152 DOMETIC

We will be happy to provide you with further information about WAECO products. Please order our free catalogue with no obligation to buy on our homepage: www.dometic-waeco.com

DOMETIC PP152 - 1

Please read this manual carefully before installing and starting up and store it in a safe place. If the device is resold, this instruction manual must be handed over to the purchaser along with the device.

Contents

1 Notes on using the manual 18
2 General safety instructions 19
3 Device guides 21
4 Intended use 21
5 Technical description 21
6 Connecting the inverter 22
7 Using the inverter. 24
8 Replacing the fuse 25
9 Cleaning and caring for the inverter. 25
10 Rectifying faults 26
11 Guarantee 26
12 Disposal 27
13 Technical data 27

1 Notes on using the manual

DOMETIC PP152 - Notes on using the manual - 1

Caution

Safety instruction: Failure to observe this instruction can cause material damage and impair the function of the device.

DOMETIC PP152 - Caution - 1

Caution

Safety instruction relating to a danger from an electrical current or voltage. Failure to observe this instruction can cause material damage and personal injury and impair the function of the device.

DOMETIC PP152 - Caution - 1

Note

Supplementary information on operating the device.

Action: This symbol indicates that action is required on your part. The required action is described step-by-step.

This symbol describes the result of an action.

Please observe the following safety instructions.

2 General safety instructions

2.1 General safety

DOMETIC PP152 - General safety - 1

Caution

WAECO International will not be held liable for claims for damage resulting from the following:

  • Faulty assembly or connection
  • Damage to the appliance resulting from mechanical influences and excess voltage
  • Alterations to the device without express permission of WAECO International
  • Use for purposes other than those described in the operating manual

  • Use the device only as intended.

  • Do not operate the device in a damp or wet environment.
  • Maintenance and repair work may only be carried out by qualified personnel who are familiar with the risks involved and the relevant regulations.

2.2 Safety when installing the device

DOMETIC PP152 - Safety when installing the device - 1

Caution - danger of electrocution

Never connect more than one consumer device to the inverter. If you connect more than one device, a short circuit may occur.

  • Ensure the device is standing firmly.

The device must be set up and fastened in such a way that it cannot tip over or fall down.

  • Take the precautions necessary to ensure that children cannot interfere with operation.

Dangerous situations may occur which cannot be recognised by children!

  • Do not expose the device to a heat source (such as direct sunlight or heating). Avoid additional heating of the device in this way.

For installation on boats

  • If electrical devices are incorrectly installed on boats, corrosion damage might occur. Have the inverter installed by a specialist (marine) electrician.

Electrical cables

  • If cables have to be fed through metal walls or other walls with sharp edges, use ducts or wire bushings to prevent damage.
  • Do not lay cables which are loose or bent next to electrically conductive material (metal).
  • Do not pull on the cables.
  • Do not lay the 230V mains cable and the 12/24V DC cable in the same duct.
  • Fasten the cables securely.
  • Lay the cables so that they cannot be tripped over or damaged.

2.3 Operating the appliance safely

DOMETIC PP152 - Operating the appliance safely - 1

Caution

Note the following basic safety information when using electrical devices to protect against:

Electric shock
- Fire hazards
- Injury

  • Do not operate the device near gas or flammable material; the surface temperature can reach up to 60^ .
  • Operate the device only if you are certain that the housing and the cables are undamaged.
  • Make sure the air inlets and outlets of the device are not covered.
  • Ensure good ventilation.
  • Do not connect the 230V output of the inverter (fig. 1, page 3) to a different 230V source.
  • Even after the fuse triggers, parts of the inverter remain live.
  • Always disconnect the power supply when working on the device.

3 Device guides

Description

Item no.

PerfectPower PP152: inverter with cable for a 12 V or socket and four holders

PerfectPower PP154: inverter with cable for a 24 V socket PP154 and four holders

PerfectPower PP402: inverter with terminals for a 12 V battery and four holders

PerfectPower PP404: inverter with terminals for a 24 V bat- PP404 tery and four holders

PerfectPower PP602: inverter with terminals for a 12 V battery and four holders

PerfectPower PP604: inverter with terminals for a 24 V bat- PP604 tery and four holders

4 Intended use

The inverters are used to convert a direct current of 12V or 24V into a 230V AC supply of 50Hz .

12 V: PerfectPower PP152, PP402 and PP602
24 V: PerfectPower PP154, PP404 and PP604

5 Technical description

The PerfectPower inverters can be operated wherever there is a 12 V DC supply (for PP152, PP402, PP602) or a 24 V DC supply (for PP154, PP404, PP604). The devices are additionally cooled with a load and temperature-dependent fan.

The maximum constant output for the devices is as follows:

  • For PP152 and PP154 inverters 150 W
  • For PP402 and PP404 inverters 350 W
  • For PP602 and PP604 inverters 550 W

Never connect devices that have a higher power requirement.

The inverter is equipped with protection against thermal and electrical overloading, as well as excess and insufficient voltage. The inverter switches off:

  • If its internal temperature is too high
  • If the load exceeds the values stated above
  • If the input voltage is too high or too low

The inverter can be switched on and off using the switch directly on the device or using an external switch.

DOMETIC PP152 - Technical description - 1

Note

Note when connecting devices with an electrical drive (such as power drills and refrigerators), that they often need more power than is stated on the type plate.

6 Connecting the inverter

6.1 Fastening the inverter

You can fasten the inverter using the four holders supplied.

When selecting the installation location, observe the following instructions:

  • The inverter can be mounted horizontally or vertically.
  • The inverter must be installed in a place that is protected from moisture.
  • The inverter may not be installed in the presence of flammable materials.
  • The inverter may not be installed in a dusty environment.
  • The place of installation must be well-ventilated. A ventilation system must be present for installations in small, enclosed spaces. The clearance around the inverter must be at least 25~cm (fig. 4, page 5).
  • The air intake on the underside or the air outlet on the back of the inverter must remain clear.
  • For ambient temperatures higher than 40^ (such as in engine or heating compartments, or direct sunlight), the heat from the inverter under load can lead to the automatic shut-off of the inverter.
  • The installation surface must be level and sufficiently sturdy.

DOMETIC PP152 - Fastening the inverter - 1

Caution!

Before drilling any holes, ensure that no electrical cables or other parts of the vehicle can be damaged by drilling, sawing and filing.

Fasten the inverter as follows (fig. 5, page 5):

Clip two holders on the lower left bar and two on the right. You can move the holders as required.

Fasten the inverter by screwing one screw through each hole in the holders.

6.2 Connecting the PP152 and PP154

The inverter is connected via a plug connected to a 12 V socket (PP152) or a 24 V supply (PP154). The middle pin of the plug (fig. 1 4, page 3) must be connected to the positive wire and the two side brackets of the plug (fig. 1 5, page 3) must be connected to the negative wire.

DOMETIC PP152 - Connecting the PP152 and PP154 - 1

Caution

Make sure the plug is firmly connected in the socket. If the connection is loose, the plug may heat up.

DOMETIC PP152 - Caution - 1

Caution

The rating of the socket, the supply cable and the fuse must be at least 15 amps. Do not put in a fuse with a higher rating.

6.3 Connecting the PP402, PP404, PP602 and PP604

DOMETIC PP152 - Connecting the PP402, PP404, PP602 and PP604 - 1

Caution

To set up the inverter, connect the red cable (fig. 1 4, page 3) to the positive pole (+) of the battery and the black cable (fig. 1 5, page 3) to the negative pole (-) of the battery. Make sure the battery poles are clean when connecting the terminals.

DOMETIC PP152 - Caution - 1

Caution

Only extend the connection line with cables with an equal or greater cross section.

DOMETIC PP152 - Caution - 1

Caution

Do not reverse the polarity. Reversing the polarity of the connections will cause a great spark and the internal fuses will melt.

7 Using the inverter

The main switch (fig. 2 1, page 4) on the back of the device has three positions:

  • ON: the inverter is switched on.
    OFF: the inverter is switched off.
  • REMOTE: the inverter is switched on and off by an external switch.
    Connect your power consuming device, to the socket (fig. 1 1, page 3) of the inverter.

Switching on at the device

Set the main switch (fig. 2 1, page 4) to "ON".
The green LED (fig. 13, page 3) lights up.

Switching off the device

Set the main switch (fig. 2 1, page 4) to "OFF".
The green LED (fig. 1 3, page 3) goes out.

Switching on with an external device

You can also switch the inverter on and off with an external switch.

Set the main switch (fig. 2 1, page 4) to "REMOTE".
Connect the external switch to the remote port (fig. 2 4, page 4) in accordance with the following circuit diagrams:

  • External switch, voltage supply from the inverter: fig. 3, page 5

If the inverter is switched on via an external switch, the green LED (fig. 1 3, page 3) lights up.

Observe the following when using the device

If the battery voltage falls below 10.8 V (PP152/PP402/PP602) or 21.5 V (PP154/PP404/PP604) during operation, a warning tone sounds. If the battery voltage falls further, the inverter switches off and the red error LED (fig. 1 2, page 3) lights up.

If the inverter overheats, it switches off – the red error LED (fig. 1 2, page 3) lights up.

If this happens, switch the inverter off with the switch.

When it cools down, you can use the inverter again.

When operating the inverter at a high load for lengthy periods, it is advisable to start the engine in order to recharge the vehicle battery.

You can operate the inverter with the engine running or switched off. However, do not start the engine while the inverter is switched on, since the power supply to the cigarette lighter is disconnected during ignition.

8 Replacing the fuse

This is how to change the fuse of the inverter:

Take the defective fuse (fig. 2 3, page 4) out of the holder on the back.
Put in a new fuse of the same rating.

9 Cleaning and caring for the inverter

DOMETIC PP152 - Cleaning and caring for the inverter - 1

Caution

Do not use any sharp or hard objects for cleaning since they may damage the device.

Occasionally clean the device with a damp cloth.

10 Rectifying faults

FaultCauseRemedy
No output voltageNo contact to the batteryCheck contact and cable. Switch on the ignition if necessary. PP152/PP154: Check the 12/24 V socket and replace it if necessary.
No output voltageOverheatingSwitch off power consuming devices. Let the inverter cool down and ensure better ventilation.
No output voltageDefective fuse (in the inverter or the vehicle)Replace the fuse with one of the same specifications.
No output voltageDevice defectiveReplace the device.
The device switches on and off repeatedlyExcessive constant loadReduce the load.
The inverter switches off when the consumer is switched onStarting current too highCompare the device power with the maximum power of the inverter.
The output voltage is too low.Batter voltage below 10.8 V (PP152/PP402/PP602) or 21,5 V (PP154/PP404/PP604)Charge the battery (start the engine).

11 Guarantee

The statutory warranty period applies. If the product is defective, please return it to the WAECO location in your country (see the back of the instruction manual for the address) or to your dealer. For repair and guarantee processing, please include the following documents when you send in the device:

A copy of the receipt with purchasing date
- Reason for the claim or a description of the fault

12 Disposal

If possible, always take the packaging material for recycling.

DOMETIC PP152 - Disposal - 1

If you wish to finally dispose of the device, ask your local recycling centre or specialist dealer for details about how to do this in accordance with the applicable disposal regulations.

13 Technical data

The following technical data applies to all inverters:

PP152, PP402, PP602PP154, PP404, PP604
Output voltage210 – 230 V AC √n
Output frequency50 Hz ± 2 Hz
Idle current consumption< 0.25 A< 0.25 A
Rated input voltage12 V DC ***24 V DC ***
Low voltage alarm10.8 V21.5 V
Low voltage cut-off10 V20 V
Overvoltage circuit breaker15.3 V30.5 V
Heat dissipationHousing/fan
Maximum ambient temperature0 °C – 50 °C
Testing/certificationCE E24

Technical data for specific devices:

PP152PP154
Item numberPP152PP154
Constant output power150 W
Peak output power350 W
Dimensions167 x 129 x 71 mm
Weight800 g
PP402PP404
Item numberPP402PP404
Constant output power350 W
Peak output power700 W
Dimensions177 x 129 x 71 mm
Weight950 g
PP602PP604
Item numberPP602PP604
Constant output power550 W
Peak output power1100 W
Dimensions222 x 129 x 71 mm
Weight1350 g

Variations, technical improvements and delivery options reserved.

PerfectPower

5 Description technique

Dometic Italy S.p.A.

Via Virgilio, 3

I-47100 Forli

+390543754901

+390543756631

Mail: info@dometicwta.com

Overseas + Middle East

DOMETIC PP152 - Overseas + Middle East - 1

WAECO Pacific Pty. Ltd.

1 John Duncan Court

Varsity Lakes QLD 4227

+61755076000

+61755076001

Mail: sales@waeco.com.au

DOMETIC PP152 - WAECO Pacific Pty. Ltd. - 1

Dometic Switzerland AG

Riedackerstrasse 7a

CH-8153 Rümlang (Zürich)

+41448187171

+41448187191

Mail: info@waeco.ch

DOMETIC PP152 - Dometic Switzerland AG - 1

Dometic Norway AS

Skolmar 24

N-3232 Sandefjord

+4733428450

+47 33428459

Mail: firmpost@waeco.no

DOMETIC PP152 - Dometic Norway AS - 1

WAECO Impex Ltd.

Suites 2207-2211 · 22/F · Tower 1

The Gateway · 25 Canton Road

Tsim Sha Tsui · Kowloon

Hong Kong

+852 24632750

+852 24639067

Mail: info@waeco.com.hk

DOMETIC PP152 - WAECO Impex Ltd. - 1

Dometic Denmark A/S

Nordensvej 15, Taulov

DK-7000 Fredericia

+4575585966

+4575586307

Mail: info@waeco.dk

DOMETIC PP152 - Dometic Denmark A/S - 1

Domatic Benelux B.V.

Ecustraat 3

NL-4879 NP Etten-Leur

+31765029000

+31765029090

Mail: info@dometic.nl

DOMETIC PP152 - Domatic Benelux B.V. - 1

WAECO Impex Ltd.

Taipei Office

2 FL-3 · No. 56 Tunhua South Rd, Sec 2

Taipei 106, Taiwan

+886227014090

+886227060119

Mail: marketing@waeco.com.tw

DOMETIC PP152 - WAECO Impex Ltd. - 1

Dometic Spain S.L.

Avda. Sierra del Guadarrama, 16

E-28691 Villanueva de la Canada

Madrid

+34 902 111 042

+34900100245

Mail: info@dometic.es

DOMETIC PP152 - Dometic Spain S.L. - 1

Dometic Scandinavia AB

Gustaf Melins gata 7

Regional Office Middle East

PO Box 74775

Dubai, United Arab Emirates

+97143212160

+97143212170

Mail: info@dometic.ae

DOMETIC PP152 - Dometic Scandinavia AB - 1

Domatic S.N.C.

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : DOMETIC

Model : PP152

Category : Power inverter