| Product Type | Portable Generator |
| Model | FGG-2000NW |
| Brand | Ferm |
| Rated Output | 2000 W |
| Peak Output | 2200 W |
| Engine Type | 4-Stroke, OHV |
| Fuel Type | Unleaded Petrol |
| Fuel Tank Capacity | 4.5 L |
| Run Time at 50% Load | Approx. 6 hours |
| Starting System | Recoil |
| Outlet Type | 1x 230V AC Socket, 1x 12V DC |
| Dimensions (L x W x H) | 600 x 450 x 450 mm |
| Weight | 38 kg |
| Noise Level | 96 dB(A) @ 7m |
| Maintenance | Check oil before use; clean air filter every 50 hours; change oil after first 20 hours then every 100 hours |
| Safety Features | Overload protection, low oil shutdown, earth leakage circuit breaker |
| Spare Parts Availability | Spark plug, air filter, oil filter, fuel filter through Ferm service |
| General Information | Designed for outdoor use; not for home wiring; keep dry and ventilated |
Frequently Asked Questions - FGG-2000NW Ferm
What type of oil should I use for the Ferm FGG-2000NW generator?
Use SAE 10W-30 or 15W-40 engine oil for general temperatures. Refer to manual for viscosity chart.
How do I start the generator?
Turn the fuel valve to ON, close the choke, set the ignition to ON, pull the recoil start cord gently until resistance then pull firmly. Once started, open the choke gradually.
Can I run the generator indoors?
No. Generators produce carbon monoxide which is deadly. Always operate outdoors in a well-ventilated area away from windows and doors.
How often should I change the engine oil?
Change oil after the first 20 hours of use, then every 100 hours or annually. Check oil level before each use.
What is the rated output of the FGG-2000NW?
The rated output is 2000W continuous, with a peak of 2200W for short periods.
How long will it run on a full tank?
At 50% load, the generator runs approximately 6 hours on a full tank of 4.5 litres.
What should I do if the generator shuts down suddenly?
Check for low oil or overload. The generator has automatic shutdown for low oil level and overload protection. Reset after correcting the issue.
Can I connect the generator directly to my home electrical panel?
No. Only a qualified electrician can install a transfer switch. Improper connection can cause backfeeding and endanger utility workers.
How do I store the generator for long periods?
Drain fuel or add fuel stabilizer, change oil, clean the generator, and store in a dry, clean place. Cover the generator.
Where can I find spare parts for my Ferm generator?
Spare parts like spark plugs, air filters, and oil filters are available through Ferm authorized service centers or online retailers.
User questions about FGG-2000NW Ferm
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.
Download the instructions for your Generator in PDF format for free! Find your manual FGG-2000NW - Ferm and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. FGG-2000NW by Ferm.