Notice STEINBERG SBS-LW-1050 - page 10
Pick your language and provide your email: we'll send you a specifically translated version.
Product type Kitchen scale
Brand Steinberg
Model SBS-LW-1050
Maximum capacity 5 kg
Precision 1 g
Units of measurement g, kg, lb, oz
Tare function Yes
Display Backlit LCD screen
Auto-off Yes, after 2 minutes of inactivity
Low battery indicator Yes
Power supply 2 AAA batteries (included)
Platform material Stainless steel
Dimensions (L x W x H) 20 x 15 x 2 cm
Net weight 300 g
Care and cleaning Wipe with a damp cloth, do not immerse
Safety Do not exceed maximum load, use on a flat and stable surface
Spare parts and repairability Not user-serviceable, contact after-sales service

Frequently Asked Questions - SBS-LW-1050 STEINBERG

How to turn the Steinberg SBS-LW-1050 scale on and off?
Press the ON/OFF button to turn the scale on or off.
How to use the tare function?
Place an empty container on the scale, then press the TARE button to reset the display to zero. Then add ingredients.
How to change the unit of measurement?
Press the UNIT button to switch between grams (g), kilograms (kg), pounds (lb), and ounces (oz).
What to do if the scale displays nothing?
Check that the batteries are properly installed and not drained. Replace them if necessary.
How to clean the scale?
Wipe the surface with a slightly damp soft cloth. Never immerse the scale in water.
The scale displays 'Err' or 'EEEE'. What to do?
This indicates an overload. Immediately remove excess weight. The maximum capacity is 5 kg.
What is the precision of the scale?
The scale measures to the nearest gram. For accurate measurements, use it on a flat and stable surface.
How to reset the scale?
Remove the batteries for 10 seconds, then put them back. The scale will reset automatically.
The scale turns off by itself, is this normal?
Yes, the scale has an auto-off function after 2 minutes of inactivity to save batteries.
Where to find replacement batteries?
The batteries are standard AAA models, available in all electronics stores or supermarkets.

User questions about SBS-LW-1050 STEINBERG

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

Your email remains private: it is only used to notify you if someone answers your question.

No questions yet. Be the first to ask one.

Download the instructions for your Scale in PDF format for free! Find your manual SBS-LW-1050 - STEINBERG and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. SBS-LW-1050 by STEINBERG.

USER MANUAL SBS-LW-1050 STEINBERG

1- Battery compartment

2- Switch power

3- 6 x AA batteries

This User Manual has been translated using machine translation. We have made every effort to ensure the translation is accurate, but please note that automated translations are not perfect and are not meant to replace human translators. The official version of the User Manual is in English. Any differences between the translated version and the original English are not legally binding. If you have any questions about the accuracy of the translation, please refer to the English version, which is the official reference. More language versions are available upon request via info@expondo.com.

Technical data

Parameter descriptionParameter value
Product namePrecision balance
ModelSBS-LW-1030SBS-LW-1040SBS-LW-1050SBS-LW-1060SBS-LW-1070
Max load [kg]3361020
Min load [g]0.22
Dimensions (Width x Length x Height) (mm)205 x 300 x 95210 x 315 x 95205 x 300 x 95210 x 310 x 95205 x 300 x 95
Weight [kg]1.61.65
Division [g]0.010.1
Power adapter [V/A]12 / 1.0
Battery6 x AA Batteries
Protection classII

Purpose

The product is used to measure the weight of objects with high accuracy and precision, typically within a milligram or even finer increments. Its purpose is essential in environments where precise measurements are crucial, such as in laboratories, research facilities, pharmaceuticals, and industrial applications.

Usage

Preparation

Batteries

Technical diagram of an electronic device with labeled components and internal structure.

1- Battery compartment

2- Switch power

3- 6 x AA batteries

Setting up the scale/balance

STEINBERG SBS-LW-1050 - Setting up the scale/balance - 1

CAUTION

  • Avoid installing the scale/balance in direct sunlight, as it may lead to discoloration or malfunction.
  • Ensure the scale/balance is set up on a sturdy weighing table so that it remains level. • The scale/balance will not provide accurate measurements if it is not properly leveled. • For accurate weighing, always place the scale/balance on a firm, flat, and level surface.

Weighing

Before Weighing

Whenever possible, allow the balance to warm up for 10 minutes after turning it on. This ensures the balance will function properly and provide accurate measurements.

STEINBERG SBS-LW-1050 - Before Weighing - 1

NOTE

- Error messages

• : Overload - Err-Z: Exceed zero track range when turning on the power - Err- S: The scale is unstable when turning on the power - : Low battery

Weighing Procedures

1. Turn on the Balance

Press ON/OFF to power on the balance. When the power is turned on, all display segments will briefly appear on the LCD, and after a few seconds, "0" will be displayed.

2. Select the Weighing Unit

Press UNIT to choose the desired weighing unit (e.g., "g", "ct", etc.). The selected unit will be shown alongside the weight value.

3. Start Weighing

• Without a container

1) Ensure the display reads "0". If not, press ZERO to reset it to "0". 2) Place the object on the weighing platform. 3) Once the reading stabilizes, the stability indicator will appear.

- With a container

1) Place the empty container on the platform. 2) Wait for the stability indicator to appear, then press TARB to reset the display to "0". 3) Add the objects to be weighed into the container. When the reading becomes stable, the stability indicator will appear.

Calibration

When to Calibrate

Calibration may be necessary when the scale/balance is first installed or moved a significant distance, as the

gravitational force affecting the weight may vary between locations. Additionally, over time and with regular use, mechanical deviations can occur, making recalibration necessary.

How to Calibrate

1. Prepare for Calibration

Before entering calibration mode, locate the switch key on the bottom of the scale and turn it on.

Then, press ON/OFF to power on the scale and allow it to warm up for 1 minute.

2. Enter Calibration Mode

1) Press ON/OFF to power on the scale.

2) Once the display shows flashing digits followed by "----", press ZERO. The display will show "CAL". Press ZERO again, and the display will show "X0000" (X is the flashing digit).

3) Use the UNIT key to move the flashing digit to the right, and press PCS or TARB to increase the value. (X represents the calibration weight, which should be set based on your specific calibration requirements).

3. Calibration with the Weight

1) After selecting the appropriate calibration weight, place the weight on the platform.

2) Wait for the stability indicator to appear, then press ZERO.

3) The display will return to weighing mode, indicating that calibration is complete.

4. Verify Calibration

1) Turn off the scale by pressing ON/OFF, then turn it back on.

2) Place the calibration weight on the platform to verify the accuracy of the weighing.

3) If the weight is not accurate, repeat steps 2-4.

Counting Procedures

1. Turn on the Scale

Press ON/OFF to power on the scale. Wait until "0" appears on the display.

2. Start the Count Procedure

If necessary, press ZERO to reset the display to "0".

3. Place Samples on the Pan

Place a predetermined number of sample items (either 10, 20, 50, or 100 pieces) on the pan. The weight of the samples will be displayed. Press PCS to enter PCS (piece counting) mode. Then press UNIT, and the display will show "P=XX pcs". Press UNIT again to select the sample size (10, 20, 50, or 100).

4. Confirm the Sample Size

Press PCS to confirm. The display will show "XX pcs", indicating the sample size you selected. The scale will store the sample size, and you can now remove the samples if you want the display to return to "0".

5. Return to Weighing Mode

Press PCS again to return to the standard weighing mode.

Function Settings

  1. Press ON/OFF to turn on the scale. The display will show flashing digits, followed by "----". Press PRINT, and the display will show "b xxx BAU" (baud rate). Use the UNIT key to select from 1200, 2400, 4800, or 9600 (default: 9600). Press ZERO to enter Parity mode. The display will show "P xxx PAR". Use to select from odd, even, or none:
  2. Odd: 7 data bits with odd parity • Even: 7 data bits with even parity • None: 8 data bits without parity (default: none)

Press ZERO to enter Print mode. The display will show "n xxx Mod". Use UNIT to choose from:

• OFF: Serial data output disabled • KEY: Data prints on-demand when PRINT is pressed (default) • STB: Data prints automatically when the scale stabilizes - Con: Continuous printing Press ZERO again to return to weighing mode.

  1. Press ON/OFF to turn on the scale. The display will show flashing digits followed by "----". Press UNIT to enter unit selection mode. The display will show "ON X" (where X stands for units like g, oz, lb, dwt, etc.). Press UNIT to toggle between ON (activate the selected unit) or OFF (deactivate the unit). Press ZERO to select and confirm the unit mode, then press ZERO again to return to weighing mode.
  2. Switch the power to "ON" and press ON/OFF to turn on the scale. The display will show "F-E-9 to 0" followed by "----". Press PCS to enter Zero Track settings. The display will show "Zrd x.x d". Use

UNIT to select the Zero Track value (0.0d to 2.0d). Press ZERO to enter Zero Track Time settings, displayed as "Zrt x.x sec". Use UNIT to select the time (0.5 to 4.0 seconds). Press ZERO to set Zero value, displayed as "rzd x d". Use UNIT to choose between 1d, 3d, 5d, or 8d.

Press ZERO to enter Filter Range (FIL) settings. Use UNIT to select the filter range (0-3). Press ZERO to enter the zero range adjustment for power-on. Use UNIT to select percentage values (PZR 1, PZR 2, PZR 3, etc.). Press ZERO to set the Zero range, then use UNIT to select percentage values for zero range (KZR 3, 4, 5, 10).

Press ZERO to enter TARE range settings. Use UNIT to select percentage (KTR 50 or KTR 100). Press ZERO to enter overload protection settings. Use UNIT to select overload values (0, OVR-2, OVR-5, OVR-10).

Press ZERO to set the beep function. Use UNIT to toggle between "bz ON" (activate) or "bz OFF" (deactivate). Press ZERO to unite the TARE and ZERO functions. Use UNIT to switch between "ZT ON" (activated) and "ZT OFF" (deactivated).

Press ZERO to enter Auto-Off settings. The display will show "A xxx". Use UNIT to select the auto-off time (3, 5, 10 minutes, or OFF). Press ZERO to adjust the backlight. The display will show "L X". Use UNIT to select:

• OFF: Disable backlight • ON: Backlight always on • Au: Auto backlight mode

  1. Press ZERO to return to weighing mode.

Disposing of Used Devices

Do not dispose of this device in municipal waste systems. Hand it over to an electric and electrical device recycling and collection point. Check the symbol on the product, instruction manual and packaging. The plastics used to construct the device can be recycled in accordance with their markings. By choosing to recycle you are making a significant contribution to the protection of our environment.

Contact local authorities for information on your local recycling facility.

Parts

Back side

1

1- AC adaptor socket

Top

UNIT PCS PRINT ON/OFF TARB ZERO

Keypad Functions

  1. ON/OFF: Turns the power on or off.
  2. ZERO: Resets the scale to zero; the zero-setting range is 4% of the total capacity.
  3. TARE: Deducts the weight of the container from the total weight.
  4. PRINT: Prints the data currently displayed.
  5. UNIT: Toggles between different weighing units.
  6. PCS: Activates the counting function.

Display

1 2 3 888888 4 5 6

1- Low battery indicator 2- Negative value indicator

3- STABLE indicator (when the reading is stable)

4- Weighing unit 5- TARE indicator 6- ZERO indicator

Technical diagram of an electronic device with labeled components and internal structure.

Keyboard functions

1- AC adapter socket

Up

UNIT PCS PRINT ON/OFF TARB ZERO

Keyboard functions

1- Battery compartment

1- Battery compartment

1- Battery

2- Power switch

3- 6 x AA batteries

Keyboard functions

1- Battery compartment

2- Power on

3- 6 x AA batteries

Setting the scale

STEINBERG SBS-LW-1050 - Setting the scale - 1

WARNING

1- Battery compartment

2- Power switch

3- 6 x AA batteries

Keyboard functions

1. Prepare for calibration

2. Start this procedure

Keyboard functions

1- Battery compartment 2- Power on 3- 6 x AA batteries

Keypad functions

3. Place the samples in the pan

Keyboard functions

1- AC adapter socket

Up

UNIT PCS PRINT ON/OFF TARB ZERO

Keyboard functions

1- Battery compartment 2- Switch on the power 3- 6×AA batteries

Scale/scale setting

STEINBERG SBS-LW-1050 - Scale/scale setting - 1

WARNING!

1- Battery compartment

2- Power switch

1- Battery compartment 2- Turn on the power

3- 6 x AA batteries

Setting up the scale

STEINBERG SBS-LW-1050 - Setting up the scale - 1

CAUTION

Keyboard functions

  1. ON/OFF: Turns the power on or off.
  2. ZERO Resets the scale to zero; the zero setting range is 4% of total capacity.
  3. TARE Subtracts the weight of the container from the total weight.
  4. PRINT Prints the currently displayed data.
  5. UNIT Switches between different weighing units.
  6. PCS Activates the counting function.

Display

1 2 3 4 5 6 8888888 9

1- Low battery indicator

1- Battery compartment

2- Power switch

3- 6 x AA batteries

1- Battery compartment

2- Power switch

3- 6 x AA batteries

1- AC adapter socket

Top

UNIT PCS PRINT ON/OFF TARB ZERO

1- Battery compartment

2- Power switch

3- 6 x AA batteries

Scale/scale adjustment

STEINBERG SBS-LW-1050 - Scale/scale adjustment - 1

CAUTION

Keyboard functions

For the disposal of the device, please consider and act according to the national and local rules and regulations.

CONTACT

expondo Polska sp. z o.o. sp. k.

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : STEINBERG

Model : SBS-LW-1050

Category : Scale