| Product Type | Electric Storage Water Heater |
| Model | TGR100NGC6 |
| Brand | Gorenje |
| Capacity | 100 L |
| Dimensions (HxWxD) | 800 x 500 x 500 mm |
| Weight (empty) | 30 kg |
| Power Supply | 230 V / 50 Hz |
| Nominal Power | 2.4 kW |
| Temperature Range | 30 °C – 80 °C |
| Heating Element | Copper immersion heater with thermostat |
| Safety Features | Thermal cut-off, pressure relief valve, overheating protection |
| Insulation | Polyurethane foam, 50 mm thickness |
| Mains Connection | Hardwired or via plug (depending on model) |
| Water Connection | G 1/2" inlet and outlet |
| Maximum Pressure | 0.6 MPa (6 bar) |
| Material | Enameled steel tank |
| Energy Efficiency Class | C (typical) |
| Standby Consumption | 1.2 kWh/24h |
| Installation Type | Vertical wall-mounted |
| Protection Class | IPX4 |
| Maintenance | Annual check of anode rod and pressure relief valve |
| Spare Parts | Thermostat, heating element, anode rod, gaskets |
Frequently Asked Questions - TGR100NGC6 GORENJE
How do I install the Gorenje TGR100NGC6 boiler?
Installation should be performed by a qualified professional. Ensure the wall can support the weight, connect to cold water supply and outlet, and wire to a 230V circuit with proper grounding. Follow the detailed steps in the manual.
What is the maximum temperature setting?
The thermostat can be adjusted up to 80 °C. For energy savings and safety, a setting of 55-60 °C is recommended.
Why is the water not heating?
Check if the power supply is on and the thermostat is not tripped. If the heating element has failed, it may need replacement. Also verify that the overheat protection has not activated.
How often should I replace the anode rod?
Inspect the magnesium anode rod annually and replace every 2-3 years, or sooner if heavily corroded. This prevents tank rust.
What does the pressure relief valve do?
It releases excess pressure if the water temperature rises too high or pressure exceeds 0.6 MPa (6 bar). Test it regularly by lifting the lever.
Can I install the boiler outdoors?
No, this boiler is designed for indoor installation in a frost-free environment. Exposure to weather can damage electrical components.
How do I descale the boiler?
Descaling should be done by a professional using appropriate descaler. For minor scale, you can flush the tank with vinegar solution, but follow manual instructions.
What does the error code E1 mean?
E1 typically indicates a sensor fault or overheat. Try resetting the boiler by turning power off for 10 seconds. If persists, contact service.
How long does it take to heat 100 litres?
With a 2.4 kW element, heating from 15 °C to 60 °C takes approximately 2 hours 15 minutes, depending on insulation.
Where can I find spare parts?
Authorized Gorenje service centers carry genuine parts such as thermostats, heating elements, and anode rods. Use only original parts for safety.
User questions about TGR100NGC6 GORENJE
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
No questions yet. Be the first to ask one.
Download the instructions for your Boiler in PDF format for free! Find your manual TGR100NGC6 - GORENJE and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. TGR100NGC6 by GORENJE.