| Product Type | Digital Multimeter |
| Brand | BENNING |
| Model | IT 130 |
| Dimensions (H x W x D) | 180 mm x 87 mm x 47 mm |
| Weight | Approx. 350 g (including battery) |
| Power Supply | 9 V battery (IEC 6LR61) |
| Measuring Functions | AC/DC voltage, AC/DC current, resistance, continuity, diode test, capacitance, frequency |
| Voltage Range (DC) | 0 to 600 V |
| Voltage Range (AC) | 0 to 600 V True RMS |
| Current Range (DC) | 0 to 10 A |
| Resistance Range | 0 to 40 MΩ |
| Safety Rating | CAT III 600 V |
| Display | LCD, 4000 counts |
| Auto-Ranging | Yes |
| Data Hold | Yes |
| Backlight | Yes |
| Low Battery Indication | Yes |
| Overload Protection | Yes |
| Maintenance | Clean with a dry cloth; do not use solvents |
| Spare Parts | Test leads, 9 V battery |
| Repairability | Device is not user-serviceable; contact BENNING service |
| Included Accessories | Test leads, battery, user manual |
Frequently Asked Questions - IT 130 BENNING
How do I measure AC voltage with the BENNING IT 130?
Turn the rotary switch to the V~ position. Connect the black test lead to COM and red to VΩ. Touch the probes to the circuit. The display shows the True RMS value.
What should I do if the multimeter displays 'OL'?
'OL' means overload. The measured value exceeds the selected range. Switch to a higher range or use auto-range if available.
How to replace the battery in the IT 130?
Turn off the meter and remove the test leads. Unscrew the battery compartment cover on the back. Replace the 9V battery with a new one. Reattach the cover.
Is the IT 130 safe for measuring mains voltage?
Yes, it is rated CAT III 600V, suitable for measuring mains voltage in household and industrial installations. Always observe safety precautions.
How to test continuity with this multimeter?
Set the rotary switch to the continuity/diode position (usually a diode symbol). Connect the probes as for resistance. If the circuit is intact (<50Ω), a beep will sound.
What does 'Auto Power Off' feature do?
The meter automatically turns off after about 15 minutes of inactivity to save battery. Press any button to wake it up.
Can I measure capacitance with the IT 130?
Yes, select the capacitance range (usually marked with a capacitor symbol). Discharge the capacitor first. Connect the probes and read the value.
How do I perform a diode test?
Turn the dial to the diode test position. Connect the red probe to the anode and black to cathode. A good Si diode shows about 0.6-0.7V; a short shows 0V; open shows OL.
Why is the display showing a low battery symbol?
The battery voltage is low. Replace the 9V battery as soon as possible to avoid inaccurate readings.
How to clean the BENNING IT 130?
Wipe the housing with a damp, lint-free cloth and mild detergent. Do not use abrasives or solvents. Keep the input jacks clean and dry.