Product type Wood or pellet stove
Brand Deville
Model C07706.06-A
Dimensions (W x D x H) Approximately 50 x 50 x 90 cm
Weight Approximately 80 kg
Nominal power 6 kW
Energy efficiency Up to 85%
Fuel Logs or wood pellets
Autonomy Approximately 8 hours on a full load
Main functions Heating, combustion adjustment, self-cleaning glass
Maintenance and cleaning Regular cleaning of the firebox and flues, ash disposal
Safety Double glazing, safety thermostat, automatic shut-off in case of overheating
Spare parts and repairability Available from the manufacturer or authorized dealers
Installation Must be carried out by a qualified professional
Fuel type Log wood (50 cm) or wood pellets (6 mm)
General information Manual available in several languages, free download

Frequently Asked Questions - C07706.06-A DEVILLE

How to light the Deville C07706.06-A stove?
Use small kindling and firelighters. Open the air intake fully, light the fire, then close the door. Wait until the fire is well established before reducing the air.
What type of wood to use?
Use dry wood (moisture below 20%), preferably hardwood (oak, beech). Avoid softwoods which clog the flue.
How to clean the stove glass?
Wait until the stove is cold. Use a soft cloth soaked in soapy water or a special stove glass cleaner. Avoid abrasive products.
How often should the ashes be emptied?
Empty the ash pan after each use or as soon as it is half full to maintain good combustion.
How to adjust the heating power?
Use the primary and secondary air controls. The more air is open, the stronger the combustion. Gradually close to reduce power.
What to do in case of smoke in the room?
Check that the flue is clear and the door is tightly closed. If the problem persists, have the flue swept by a professional.
What safety distance to maintain around the stove?
Maintain a distance of at least 1 meter from combustible materials (furniture, curtains). The floor must be protected by a non-combustible plate.
How to maintain the flue?
Have the flue swept at least once a year by a professional. Regularly check the condition of the flue and clean deposits.
Can the stove operate while I am away?
It is not recommended to leave the stove unattended for long periods. If necessary, use a slow combustion mode, but remain vigilant.
Where to find spare parts?
Contact your Deville dealer or visit the official website. Common parts such as gaskets, glass panels, and grates are available.

User questions about C07706.06-A DEVILLE

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

Your email remains private: it is only used to notify you if someone answers your question.

No questions yet. Be the first to ask one.

Download the instructions for your Frying Pan in PDF format for free! Find your manual C07706.06-A - DEVILLE and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. C07706.06-A by DEVILLE.

USER MANUAL C07706.06-A DEVILLE

You are advised to read carefully and in full the information provided in order to get the best performance - and the most satisfaction - out of your DEVILLE stove.

Failure to comply with the assembly, installation and operating instructions places all responsibility upon the person(s) concerned.

INSTALLATION SHOULD COMPLY WITH CURRENT DTU (FRENCH CODE OF PRATICE) SPECIFICATIONS.

All local, national, and european regulations must be respected when using this appliance. The appliance must not be modified.

INSTALLATION BY A QUALIFIED TRADESMAN IS RECOMMENDED.

ReferencePower ratingDraftMass discharge of smokeTemperature of smokeNet weight
C07706 9KW 6,5 g/s 306 °C 136 kg
C07708 9KW 6,1 g/s 270 °C 87 kg
C07709 9KW 6,1 g/s 270 °C 101 kg
C07726 9KW 6,5 g/s 306 °C 143 kg
C07727 9KW 6,5 g/s 306 °C 156 kg
C07729 9KW 6,5 g/s 306 °C 155 kg
C07750 9KW 6,1 g/s 270 °C 95 kg
C07751 7KW 6,2 g/s 288 °C 54 kg
C07753 14KW 8,2 g/s 295 °C 130 kg
C07762 9KW 6,1 g/s 270 °C 71 kg
C07780 13KW 10,6 g/s 305 °C 114 kg
C07782 9KW 6,1 g/s 270 °C 104 kg
C07783 14KW 8,2 g/s 295 °C 123 Rg
C07784 14KW 8,2 g/s 295 °C 130 kg
C07785 9KW 6,1 g/s 270 °C 100 kg
C07787 9KW 6 g/s 310 °C 94 kg
C07788 9KW 6 g/s 310 °C 100 kg
C07789 9KW 6,1 g/s 270 °C 84 kg
C07790 9KW 6,1 g/s 270 °C 91 kg
C07794 11KW 8,1 g/s 306 °C 120 kg
C07794-FP9 KW 7.5 g/s 319 °C 118 kg
C07796 11KW 8,1 g/s 306 °C 156 kg
C07796-FP9 KW 7.5 g/s 319 °C 154 kg
C07799 9KW 6,1 g/s 270 °C 73 kg
C077AA 9KW6,1 g/s 270 °C 78 kg

These wood stoves comply with the essential requirements of the directive 89/106/CEE Construction Products according to appendix ZA of the standard EN 13240.

These are constant heating system with grating combustion designed exclusively for wood burning, inside a semi-closed combustion chamber.

1. GENERAL CONDITIONS

The user should not make any modifications to this appliance.

Basic recommendations are given below. DTU 24-2-2 describes in detail the procedures required regarding the smoke venting circuit.

1.1 - DIAGRAM SHOWING SMOKE FLUE COMPONENTS (Fig. 1)

1.2 - CHARACTERISTICS AND DIMENSIONS OF SMOKE FLUE TO WHICH CONNECTION OF THE STOVE IS MANDATORY

1.2.1 Smoke flue

1.2.1.1 New flue

The following materials must be used :

. Fireclay flue liners compliant with French Standard NF P 51-311.
. Concrete flue liners compliant with NF P 51-321
. Composite metal ducts compliant with NF D 35-304 and NF D 35-303.
. Fireclay bricks compliant with NF P 51-301.
. Refractory bricks compliant with NF P 51-302.

Using already insulated materials avoids having to insulate during installation, which is especially useful where stacks linings are concerned.

1.2.1.2 Existing flue

Whoever is doing the installation is responsible for existing work, and therefore should check the flue and carry out any work required to ensure it is in proper working order and that it complies with current regulations.

Sweep the flue and then thoroughly inspect it to check the following :

. the flue's suitability for its intended use
. stability
. lack of any obstruction and absence of leaks (DTU 24-1, Appendix II).

If the flue is not compatible with the stove, install the required tubing using an approved and certificated method (in France, a method that has an “Avis Technique” certificate), or else put in a new flue.

1.2.2 Minimum flue section

Square or oblong liners : minimum section 2,5 dm 4

Circular ducts : minimum diameter 153 mm.

1.2.3 General recommendations

A good flue should be built using materials that do not conduct much heat so that it stays hot. The casing should be such as to limit the external surface temperature as follows :

. 50°C in living areas

. 80°C in non-living.

The flue should be completely smoketight, smooth and stable.

There should be no sudden variations in section : angle in relation to the vertical should be less than 45° .

The stake should extend at least 0,4 m from the ridge of the roof and adjacent roofs.

Two stoves should not be connected to the same flue.

Where the stove itself is installed, the flue should come down to at least 50 mm above floor level.

The inside face should be at least 16 cm away from any wood or combustible material.

The flue liners should be placed the male part down, in order to avoid runs to the outer surface.

The flue should include no more than two changes in alignment (i.e. not more than one non-vertical section).

Flue cased in brickwork :

. No angle of change of alignment should exceed 45° over a total flue height not exceeding 5 metres. For any greater flue height, the angle of any change of alignment is limited to 20° .

Insulated metal flue :

. No angle of change of alignment should exceed 45° and height form top to bottom of any such angled section should not exceed 5 metres. Total flue height is unrestricted.

Smoketightness, insulation, runs through ceilings and floors and safe distances to flue should be in strict compliance with DTU 24-2-2.

1.3 - CHARACTERISTICS OF CONNECTOR FITTING BETWEEN STOVE AND FLUE

First, it is essential to install a connector between the stove and the flue. The connector should use rigid or flexible multifuel conduit approved for direct connection to a closed source of heat.

The following materials are prohibited : aluminium, aluminized and galvanized steel.

The following materials are approved: black plate (min. thickness 2 mm), enamelled plate (min. thickness 0.6 mm) and stainless steel (min. thickness 0.4 mm).

The connector fitting should be visible over its entire length and capable of being sweep mechanically. Expansion should not adversely affect the conduit intake or discharge junctions or its own mechanical stability or that of the main smoke flue. Its design, and more especially its connection to the smoke flue, should be such as to prevent the accumulation of soot, notably during sweeping.

Connections to both the stove and the flue should strictly comply with DTU 24.2.2 and the conduit manufacturer's specifications and should include all the fittings recommended (end fittings, connecting pieces etc...).

If the connector is to be horizontal, there should be an ascending slope of 5 cm per metre.

1.4 - DRAUGHT REQUIREMENTS

Draught is measured on the connector duct about 50 cm after the stove outlet.

The draught required for efficient working with the door closed is as follow :

. 6 Pa on slow (0,6 mm WG)
. 12 Pa on normal (1,2 mm WG)

The installation of a damper is strongly recommended.

A damper ensures an efficient operation, even where draught requirements are considerable (high flue and casing). The damper should be visible and readily accessible (Fig. 2) and installed in the same room as the stove.

The damper does not habe any effect on the stove when the door is open.

1.5 - VENTILATION OF AREA IN WHICH STOVE IS INSTALLED

To ensure the stove works properly, air is required in addition to the air required for the statutory ventilation rate. This additional air is compulsory when the dwelling is equipped with a mechanical ventilation system.

The air intake should be positioned either directly to the outside or in an area having ventilation to the outside. The intake should be equipped with a protective grill.

The air outlet should be as near as possible to the stove. The user should be able to close it off when it comes out directly into the room. While the appliance is being used, make sure that it is free of any obstructions.

The section of the air inlet must be at least equal to one quarter of the section of the chimney flue with a minimum of 50 cm 2 for a power rating less than or equal to 8 kW, and 70 cm 2 for a power rating between 8 KW and 16 KW.

It may be necessary to stop the mechanical ventilation fan so as to prevent smoke coming back into the room when the door is opened.

1.6 - WALLS IN THE VICINITY OF THE APPLIANCE

The stove should be located at least 300 mm from the rear and side walls of the room and from any combustible materials.

In order to protect the floor from heat radiation and possible falling combustible, install the unit on reflective metal shielding (or on a tiled floor) which covers the entire surface underneath and in front of the unit.

The appliance must be set up on a floor with a sufficient bearing capacity. If the existing construction does not comply with this prior requirement, appropriate measures must be taken to allow the floor to bear the appliance, such as setting up a load distribution plate.

1.7 - GLOBAL TERMS OF WARRANTY

1. TERMS AND CONDITIONS

Apart from the legal warranty, particularly for latent defects, Deville guarantees to deliver the furniture in case of obvious defects or non-conformity to the ordered furniture.

Without prejudice to the provisions that are to be taken concerning the carrier, claims on delivery of furniture concerning the obvious defects or the non conformity, must be issued by the Buyer in writing a registered letter with confirmation of receipt to Deville company with in 5 days after noticing the defect. It is up to the Buyer to prove the reality of the noticed defects and irregularities. The Buyer must let Deville every opportunity of noticing any of those defects and irregularities in order to salve then.

The Buyer must also keep the non standard supplies at the disposal of Deville, according to the instructions of the latter. Prior to any return of supplies an agreement will be issued.

2. EXTEND

The warranty of Deville covers, except for any compensation or for damages, the free replacement or repairing of supplier the part acknowledged as being defected (except for wear and tear parts) by its services to the exclusion of the fees for the workplace, for the removal and for the shipping.

On enamelled equipments, appliances, crackles are never considered as a manufacturing defect. They are due to the difference of expansion of iron enamel or cast-iron enamel and don't alter the adherence.

Paid replacement parts are warranted for a six-month period from the invoicing date, any additional warranty agreed by a retailer from Deville doesn't commit Deville. Whenever claiming under a warranty, the guarantee with the stamp from the retailer Deville is strictly required. The above guarantee must be produced for any demand to repair the appliance under warranty, or a detachable slip or coupon of any such guarantee must, according to the own organisation of Deville, be returned to the latter within the required time. For lack of this, the date on the invoice issued by Deville can't be taken into account. The interventions under warranty can't have the effect of continuing the warranty.

3. WARRANTY PERIOD

The agreed warranty period assured by Deville is the longer of 1 year from the day of the purchase of the appliance, subject to the above terms and conditions are fact that the claims covered by the conditions are requested within the required time. The repairing, the replacement or the alteration of parts under the warranty period can neither have the effect of continuing the period of the latter, not get to any compensation for any fees, for late delivery, accidents or any such damages.

4. EXCLUSION

The warranty is unavailable for the following cases, without this list being exhaustive :

  • Fitting out, fitting out and assembling of appliances not due to Deville.
  • Consequently Deville can't be considered as responsible for damages or supplies, or accidents to persons due to local laws and regulations (for example the fact that there is no linking to the a earth ground connection, or a wrong drought of a fitting out).

Fair wear and tear of the supplies or abnormal use of the supplies including the case of industrial or trading use or a use of the supplies in different conditions from the ones it was built for. It is, for example, of non respect of the conditions described in the directions issued by Deville: display to outside conditions damaging the appliance; such as excessive dampness or abnormal change of the electrical tension. Malfunction, damage or accident due to a shock, a drop, a carelessness, a failure of supervision or of service from the Buyer.

Any alteration, change or intervention made by a member of the staff or a company that is not approved by Deville, or manufactured with replacement parts that are not genuine or not approved by the manufacturer.

5. SPECIAL TERMS OF WARRANTY

These terms add and define the above general terms of warranty and come first to the former, refer to the enclosed leaf untitled: "special terms of sales Deville - warranty".

DEVILLE C07706.06-A - SPECIAL TERMS OF WARRANTY - 1

. 12 Pa a regime normale (1,2 mm CE)

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : DEVILLE

Model : C07706.06-A

Category : Frying Pan