Product type Weather station
Brand Velleman
Model DVM8010
Dimensions (indoor station) 150 x 100 x 30 mm
Weight (indoor station) 200 g
Power supply 2 AA batteries for indoor station, 2 AA batteries for outdoor sensor
Display Backlit LCD
Main functions Indoor/outdoor temperature, indoor/outdoor humidity, barometric pressure, weather forecast, barometric trend, time/date with alarm, min/max values display
Outdoor sensor range 30 m free field
Transmission frequency 433 MHz
Indoor temperature range 0 °C to 50 °C
Outdoor temperature range -20 °C to 60 °C
Humidity range 20% to 95% RH
Pressure range 300 to 1100 hPa
Care and cleaning Clean with a soft, dry cloth. Do not use solvents or abrasive products.
Safety Do not expose to excessive moisture, extreme temperatures, or direct sunlight. Use only recommended battery type.
Spare parts and repairability Outdoor sensor available as spare part (reference DVM8010-1). The device is not user-repairable.
General information 2-year warranty. Made in China. CE marking.

Frequently Asked Questions - DVM8010 VELLEMAN

How to install the DVM8010 weather station?
Insert the batteries into the indoor station and outdoor sensor. Place the outdoor sensor in a sheltered area. The indoor station automatically searches for the signal. Wait about 5 minutes for data to display.
How to reset the weather station?
Press the RESET button on the back of the device using a pointed object (paperclip). This erases all data and restarts sensor search.
How to change the batteries?
Open the battery compartment on the back of the unit. Remove old batteries and insert new AA batteries, respecting polarity. Use alkaline batteries for better battery life.
What to do if the display shows no outdoor signal?
Check that the outdoor sensor is on (LED blinking). Move the sensor closer to the indoor station. Reset both the station and sensor by pressing RESET on both devices.
What is the outdoor sensor range?
The range is approximately 30 meters in open field. Thick walls, metal obstacles, and interference can reduce this distance.
Where to place the outdoor sensor for accurate measurements?
Place the sensor outdoors, protected from direct sunlight, rain, and wind. Ideally under an overhang about 1.5 to 2 meters above ground. Avoid metal surfaces.
How to interpret the weather forecast?
The forecast icon (sun, cloud, rain) is based on the barometric pressure trend. A rapid rise indicates good weather, a rapid drop predicts rain. It does not replace official weather bulletins.
How to set the time and date?
Press and hold the MODE button for 3 seconds. The year setting flashes. Use the UP/DOWN buttons to change, then press MODE to move to the next setting.
How to set the alarm?
Press ALARM to display the alarm time. Press and hold ALARM to enter setting mode. Use UP/DOWN to set hours and minutes. Press ALARM to confirm.
How to clean the weather station?
Clean the screen and housing with a soft, dry cloth. Never use detergents, alcohol, or abrasive products. Remove batteries before cleaning.

User questions about DVM8010 VELLEMAN

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Weather Station in PDF format for free! Find your manual DVM8010 - VELLEMAN and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. DVM8010 by VELLEMAN.

USER MANUAL DVM8010 VELLEMAN

TEMPERATURE / HUMIDITY / DEW POINT METER

DJ/M8010 -88.88 -88.88 °C Unit Mode Hand ON/OFF Light Temperature / Humidity / Hour peak Hrater

VELLEMAN DVM8010 - 2

natural_image Close-up of a black plastic electronic component with a curved base and two protruding ports (no text or symbols visible)

USER MANUAL 4

GEBRUIKERSHANDLEIDING 7

NOTICE D'EMPLOI 10

MANUAL DEL USUARIO 13

1Sensor cover
2Sensor
3LCD display
4Function keys
Ahold mode
Bbacklight indicator
C%RH & td display
Dtemperature display
Emeasuring mode
Fhumidity unit
Gtemperature unit
Hbattery indicator

To all residents of the European Union

Important environmental information about this product

VELLEMAN DVM8010 - Important environmental information about this product - 1

This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm the environment. Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken to a specialized company for recycling.

This device should be returned to your distributor or to a local recycling service. Respect the local environmental rules.

If in doubt, contact your local waste disposal authorities.

Thank you for choosing Velleman! Please read the manual thoroughly before bringing this device into service. If the device was damaged in transit, don't install or use it and contact your dealer. Damage caused by disregard of certain guidelines in this manual is not covered by the warranty and the dealer will not accept responsibility for any ensuing defects or problems.

2. Safety Instructions

VELLEMAN DVM8010 - Safety Instructions - 1Keep this device away from children and unauthorized users.
VELLEMAN DVM8010 - Safety Instructions - 2Keep this device away from rain, moisture, splashing and dripping liquids.
VELLEMAN DVM8010 - Safety Instructions - 3Protect this device from shocks and abuse. Avoid brute force when operating the device.
VELLEMAN DVM8010 - Safety Instructions - 4Protect the device against extreme heat and dust.
VELLEMAN DVM8010 - Safety Instructions - 5There are no user-serviceable parts inside the device. Refer to an authorized dealer for service and/or spare parts.

3. General Guidelines

Refer to the Velleman® Service and Quality Warranty on the last pages of this manual.

  • Famili a rise yourself with the functions of the device before actually using it.
  • All modifications of the device are forbidden.
  • Only use the device for its intended purpose. Using the device in an unauthorised way will void the warranty.

4. Features

  • 4 digits LCD
  • auto power-off
  • comes with: storage box, wristlet, batteries, user manual
  • optional telescopic tripod (not incl.): CAMB17

5. Use

Refer to the illustrations on pages 2 and 3 of this manual.

  • Remove the sensor cover [1] by releasing the screw at the back of the device and sliding the cover upwards.
  • Press the ON/OFF button to switch the device on. Press and hold ±2s to switch it off.
  • The device powers off automatically after ±20min. To disable auto-power off, press and hold the Hold/Light button while switching the device on. The display will show AP OFF. Press the Hold/Light button again to confirm. To re-enable auto-power off simply switch the device off and on again.
  • Press the Unit button multiple times to scroll through the different measuring units [F, G]:

$$ \rightarrow \% \mathrm{RH}, ^ {\circ} \mathrm{C} > \mathrm{td} ^ {\circ} \mathrm{C}, ^ {\circ} \mathrm{C} > \% \mathrm{RH}, ^ {\circ} \mathrm{F} > \mathrm{td} ^ {\circ} \mathrm{F}, ^ {\circ} \mathrm{F} $$

  • Press the Mode button to display only the highest measured values (see indicator [E]). Press a second time to display the lowest measured values. Press again to return to normal measuring mode.
  • Press the Hold/Light button shortly to go into hold-mode [A]. The current measurement remains on the display. Press again shortly to exit hold-mode and return to normal measuring mode.
  • Press and hold the Hold/Light button ±2s to switch on the backlight [B]. Press and hold again ±2s to switch the backlight off.
  • When the battery indicator [H] is shown, replace the batteries (see §8).
  • Always place the sensor cover [1] back when the device is not in use.

6. Operation tips

  • Do not touch the sensor [2] and keep the sensor away from possible interfering sources e.g. a fan, heating element, body ... Also, do not expose the sensor to direct (sun)light as this will lead to false readings.
  • Consider mounting the device on a tripod (not incl.) for longer and more stable measurements.
  • Make sure the device is at ambient temperature for accurate measurements.
  • Remove the batteries when the device is not used for a long time.

7. Ma intenance

- Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents. DO NOT submerge the device in any liquid..

8. Batteries

  • To replace the batteries, make sure the device is switched off.
  • Open the battery cover at the back by sliding it downwards (away from the sensor).
  • Take out the old batteries and replace them with 3 new and identical 1.5V AAA batteries following the polarity markings inside the battery compartment.
  • Slide the battery cover back in place.

VELLEMAN DVM8010 - Batteries - 1

Do not puncture or throw batteries in fire. Dispose of batteries in accordance with local regulations. Do not attempt to recharge non-rechargeable batteries.

Keep batteries away from children.

9. Technical specifications

LCD display4 digits
parameters°C, °F, %RH (relative humidity), ttd (dew point temperature)
measuring range-10~+50°C, +14~+122°F, 0~100%RH
resolution0.1°C, 0.1°F, 0.1%RH
accuracy±1.0°C, ±1.8°F, ±3%RH (5~95 %RH)
sample rate1x/s
operating temperature0°C ~ +50°C (32°F~122°F)
storage temperature-10°C ~ +60°C (14°F~140°F)
power supply3 x 1.5V AAA batteries (incl.)
auto power-off20 min.
dimensions121 x 60 x 30mm
weight± 180g

Use this device with original accessories only. Velleman nv cannot be held responsible in the event of damage or injury resulted from (incorrect) use of this device.

For more info concerning this product, please visit our website www.velleman.eu.

The information in this manual is subject to change without prior notice.

This manual is copyrighted. The copyright to this manual is owned by Velleman nv. All worldwide rights reserved. No part of this manual may be copied, reproduced, translated or reduced to any electronic medium o rotherwise without the prior written consent of the copyright holder.

GEBRUIKERSHANDLEIDING

1. Inl eiding

natural_image Symbol of a trash bin crossed out by a diagonal line, with no text or labels present.
natural_image Simple line drawing of a trash bin with crossed lines indicating no waste or restriction (no text or symbols)

Velleman® Service and Quality Warranty

Velleman® has over 35 years of experience in the electronics world and distributes its products in more than 85 countries. All our products fulfil strict quality requirements and legal stipulations in the EU. In order to ensure the quality, our products regularly go through an extra quality check, both by an internal quality department and by specialized external organisations. If, all precautionary measures notwithstanding, problems should occur, please make appeal to our warranty (see guarantee conditions).

General Warranty Conditions Concerning Consumer Products (for EU):

  • All consumer products are subject to a 24-month warranty on production flaws and defective material as from the original date of purchase.
  • Velleman® can decide to replace an article with an equivalent article, or to refund the retail value totally or partially when the complaint is valid and a free repair or replacement of the article is impossible, or if the expenses are out of proportion. You will be delivered a replacing article or a refund at the value of 100% of the purchase price in case of a flaw occurred in the first year after the date of purchase and delivery, or a replacing article at 50% of the purchase price or a refund at the value of 50% of the retail value in case of a flaw occurred in the second year after the date of purchase and delivery.

- Not covered by warranty:

  • all direct or indirect damage caused after delivery to the article (e.g. by oxidation, shocks, falls, dust, dirt, humidity...), and by the article, as well as its contents (e.g. data loss), compensation for loss of profits;
  • frequently replaced consumable goods, parts or accessories such as batteries, lamps, rubber parts, drive belts... (unlimited list);
  • flaws resulting from fire, water damage, lightning, accident, natural disaster, etc. ...;
  • flaws caused deliberately, negligently or resulting from improper handling, negligent maintenance, abusive use or use contrary to the manufacturer's instructions;
  • damage caused by a commercial, professional or collective use of the article (the warranty validity will be reduced to six (6) months when the article is used professionally);
  • damage resulting from an inappropriate packing and shipping of the article;
  • all damage caused by modification, repair or alteration performed by a third party without written permission by Velleman®.

  • Articles to be repaired must be delivered to your Velleman® dealer, solidly packed (preferably in the original packaging), and be completed with the original receipt of purchase and a clear flaw description.

  • Hint: In order to save on cost and time, please reread the manual and check if the flaw is caused by obvious causes prior to presenting the article for repair. Note that returning a non-defective article can also involve handling costs.
  • Repairs occurring after warranty expiration are subject to shipping costs.