MT50 - Thermometer INVENTUM - Free user manual and instructions
Find the device manual for free MT50 INVENTUM in PDF.
User questions about MT50 INVENTUM
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Thermometer in PDF format for free! Find your manual MT50 - INVENTUM and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. MT50 by INVENTUM.
USER MANUAL MT50 INVENTUM
FOREHEAD THERMOMETER
NEDERLANDS
Instruction Manual Inventum forhead thermometer, MT50 Read the instruction manual carefully before use and keep the instructions in a safe place for future reference.
EXPLANATION SYMBOLS

Small household appliances don't belong in the garbage. Deliver them to your local authority service.

Device classification type BF

Please read the instructions for use!
INTRODUCTION
With this thermometer you will be able to carry out measurements exactly and in the shortest time.
A. IMMEDIATE: Measurement in a matter of seconds
B. COMFORTABLE: Ergonomic shape permits "temperature measurement in comfort". The infrared sensor in a completely new design with water-tight lens can be thoroughly cleaned with alcohol.
C. ENERGY SAVING: Automatic cut-off switch after one minute when not being used ensures a long battery service life for at least 5000 measurements.
D. DURABLE: The latest infra-red measuring technology provides long durability.
E. EXACT: 512 scanning sequences per second ensure highest reliability and accuracy, with a deviation of ±0.3^ .
F. COMPACTNESS: The body of the thermometer is extremely light, so that the device is ideal for use at home and when travelling.
G. USER FRIENDLY: Simple operations with two buttons, 10 memories and an easy to read LCD-display provides at the touch of a finger.
H. FLEXIBILITY: Temperature can be displayed alternatively in Celsius or in Fahrenheit.
SAFETY INSTRUCTIONS
- Read the instruction manual carefully and completely before using the appliance and keep them for later use.
- The Forehead Thermometer is a sensitive electronic device. Please handle carefully and avoid exposure to mechanical shocks.
- Except for the sensor, the thermometer is NOT water-tight. For this reason, avoid direct contact with water or other liquids.
- Do not expose the thermometer to direct sunlight.
- Store the thermometer in its case out of the reach of children.
- The Forehead Thermometer has been designed for practical use, but is not meant to replace a visit to the doctor.
- The forehead thermometer is designed to measure human forehead temperatures only. DO NOT USE IT to measure the body temperature in the rectal region, under the arms, in the mouth or other areas.
- The following may affect the accuracy of measurements: increased sweat production on the forehead; medications which cause constriction of the blood vessels; irritation of the skin.
- Avoid touching the sensor tip of the device so that the accuracy of measurements is not affected by warming of the sensor casing.
- Clean the water-tight sensor with its unique construction every time after use with a soft cotton cloth which has been moistened with disinfectant.
- The device should at least remain in the same room for 30 minutes prior to the measurement.
- Check before each use that the lens is intact. If it is damaged, please contact the dealer or service address.
- This instrument is not intended for commercial or clinical use.
- The device is intended only for the purpose given in these directions for use.
-
Repairs must be carried out only by authorised service agents. Otherwise the guarantee becomes void.
-
Never immerse the thermometer in water or any other liquid.
• This device complies with EU Directive 93/42 EEC. - This device complies with standard EN 12470-5 Medical Thermometers, Requirements for Infrared Ear Thermometers (with maximum device) and also ASTM E 1965-98.
- If you have further questions about using our devices, please contact your dealer.
INSTRUCTIONS FOR USE
What you need to know about using the Inventum forehead thermometer
Before using a forehead thermometer the following should be noted:
- This thermometer is suitable for measuring the temperature of the body only on the forehead.
The physiological temperature ranges are:
- the forehead temperature, measured with a forehead thermometer: 35.8 to 37.6°C
Tip: Temperatures measured with different thermometers cannot be compared with one another. Tell your doctor or take into account when diagnosing yourself what thermometer you used in what part of the body to measure the temperature.
- The temperature of a healthy person is also affected by the following factors:
- The person's individual level (individual metabolism)
- Age (body temperature is higher in babies and small children and falls with increasing age. Greater temperature fluctuations occur in children faster and more often.)
- Clothing
- The outside temperature
- The time of day (Body temperature is lower in the morning and rises as the day goes on.)
Tip: Measuring the temperature gives a figure that provides information about a person's current temperature. If you are unsure about interpreting the results or if the result is abnormal (e.g. fever), you should consult your family doctor. This also applies to small changes in temperature, if there are other symptoms of illness, such as agitation, severe sweating, flushed skin, high pulse rate, tendency to collapse etc.
Outside view and functions

text_image
Water-tight sensor button to turnor/off and for taking readings (Scan) LCD display battery cover Button to recall saved values (memory button M)Changing the battery
Remove the screw from the battery compartment with a small screwdriver and open the lid. Remove the battery. Take a new CR-2032 lithium battery and align it with the positive terminal (anode) facing upwards. Place the battery into the battery compartment. Place the lid back and screw it tightly.
When the battery gets weak, the battery warning symbol appears (figure A). It is still possible to measure the temperature. Battery must be replaced.

If the battery is nearly flat, "Lo" and the battery warning symbol are displayed (figure B). The thermometer switches off. Replace battery promptly.

Use of the thermometer
- Keep the De SCAN-button (fully pressed down for one second) (special design to avoid accidental contact). The system begins with a self-test after 1 second; see Figure 1. When switching on, never press the SCAN-button for more than 5 seconds, as otherwise you will get a special measurement mode in which the device will not make a correct measurement. Let the device switch off automatically and then switch it on again correctly.

-
As soon as the self-test is complete, will appear the last measured temperature on the display (Figure 2). This is a sign that the thermometer is ready to make a measurement.
-
Place the measuring head on the temple, keep the SCAN-button held down and then pull evenly across the forehead to the other temple (Figure 3).
-
Let go of the SCAN-button and read the measured value. At the end of the measurement an audible signal will sound. The measured temperature appears on the display together with a face symbol (see Figure 4).
-
A laughing face means a temperature below 38^ C , whereas a sad face, accompanied by one long and then two short signals indicates a temperature above 38^ C (see Figure 5 and 6).
-
The temperature display can be switched from Celsius to Fahrenheit (and vice versa). To do this, keep the SCAN-button pressed down and press briefly on the memory button (Fig. 7 and 8).

- If the words "Lo" or "Hi" appear, the measured temperature lies outside the measurement range (details can be found under Technical Specifications); see Figure 9 and 10.
- The remark "Err" appears if the operating temperature is NOT within the ambient operating conditions (details can be found under Technical Specifications); see Figure 11.
- This thermometer has 10 memory spaces. The last temperature to be measured will be saved in memory "0", whereby previous values will be relocated by one memory space (see Figure 12). In order to recall saved values press repeatedly on the memory button. The memory space will be displayed on the upper left.
- The interval between individual measurements should be at least 10 seconds. This ensures exact determination of temperature.
- After completion of measurements the forehead thermometer switches itself off automatically after 1 minute.
Readings
| Degrees: | 36.8 |
| Celsius : | °C |
| Fahrenheit: | °F |
| Registration sequence runnings: | |
| Weak battery warning: | |
| Smiling face to show that the measured temperature is below 38°C: | |
| Sad face to show that the measured temperature is above 38 °C: |

Clean the water-tight sensor every time after use with a soft cotton which has been moistened with disinfectant. Clean the thermometer casing with a soft, dry cloth.
The thermometer should not be washed off in water. On no account should abrasive cleaners be used or the casing of the forehead thermometer be immersed in water or other liquids.
Protection
Do not expose the forehead thermometer to extreme temperatures, high air humidity or direct sunlight. Avoid strong knocks or vibrations and do not drop the thermometer. Do not touch the tip of the sensor with the fingers. Do not take the forehead thermometer apart.
Fault finding and elimination
-
Temperature reading is always too low:
-
The sensor was not drawn correctly over the forehead.
- The tip must be placed properly on the temple. If the sensor is not properly positioned, this can cause temperature readings to be too low.
• The water-tight lens is dirty.
- Clean the lens properly with a soft cotton cloth, which has been moistened with some disinfectant.
• The lens is damaged.
- Consult your dealer or our customer service department.
- The measured temperature is outside the measuring range.
- The scanning sequences were not carried out on the temple/forehead.
- This may happen when the scanning sequence is started before the forehead thermometer is placed correctly on
the temple and the ambient temperature is not within the measuring range (see "Technical Specifications"). Ensure that the SCAN-button is not released before the thermometer has been drawn completely across the forehead.
3. Warning "weak battery"
- The battery is too weak for a measurement to be made. - replace battery (see "Replacing the battery").
Technical Specifications
Measurement range 10 °C to 50 °C
Laboratory accuracy ±0,3 °C The measuring accuracy of a contact thermometer in the range 37 °C to 39 °C is ±0,1 °C
Smallest measurement interval 0,1 °C
Memory function The device has 10 memory spaces! When turned on the thermometer displays the last temperature measured. When changing the battery, all saved values will be lost!
Operating mode The thermometer works in a regulated mode.
Raised temperature alarm Sad face, accompanied by one long and then two short sounding signals.
Easy to clean, non-polluting construction
The tip of the probe is equipped with a water-tight lens, which can be washed-off with water.
Conserves energy Switches of automatically after one minute when not in use.
Warning remarks Symbol for "weak battery". Symbol "Lo" + "Hi" / "Err" as an indication that the device is operating outside the measuring range/ambient operating conditions.
Service life of the battery The battery supplied is sufficient for at least 5000 measurements.
Battery disposal Used batteries do not belong in the household waste. You are legally obliged to dispose of the batteries. Dispose of them via your specialist electrical supplier or local collecting point for recyclable waste. Note: Batteries containing pollutant substances are marked as follows: Pb = battery contains lead, Cd = battery contains cadmium, Hg = battery contains mercury.
The battery in this instrument is pollutant-free.
Ambient operating conditions 16 °C to 40 °C at a relative air humidity (not condensing) of up to 95%.
Storage conditions -20 °C to +50 °C at a relative air humidity (not condensing) of up to 95%.
Tip: Correct functioning cannot be guaranteed, if the device is used outside the specification range!
GUARANTEE & SERVICE
- The guarantee generally runs for a period of 24 months from the date of purchase.
- The guarantee period comes into force only, if date of purchase can be confirmed by submission of the corresponding proof of purchase/receipt.
- Within the guarantee period we will eliminate any defects which are existing already from the time of buying in the appliance resulting from faults which be proved against us in material and/or workmanship either by repairing or exchanging defective parts or exchanging the whole appliance.
- The guarantee period for the appliance will not be extended by the submission of the claim under guarantee. Exchanged parts will become property of the manufacturer.
- Damages which are not under responsibility of the manufacturer are not covered by the guarantee. This is valid especially for claims from improper use (e.g. operation with the wrong type of current or voltage) or maintenance as well as from normal wear and tear. Moreover the guarantee does not cover claims resulting from calcification, glass breakages or faults which have only a negligible effect on the value or operation of the appliance.
- The guarantee becomes void if repairs are carried out by third parties which are not authorized by the manufacturer to do so and/or if spare parts are used other than the original ones.
We give a guarantee of 2 months on the repairs made by our technical department.
Return the appliance, with receipt and a short description of the fault, to your supplier.