JUKI

MP-G10-TE - Sewing machine JUKI - Free user manual and instructions

Find the device manual for free MP-G10-TE JUKI in PDF.

📄 12 pages English EN Download 💬 AI Question
Notice JUKI MP-G10-TE - page 3
Pick your language and provide your email: we'll send you a specifically translated version.

User questions about MP-G10-TE JUKI

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Sewing machine in PDF format for free! Find your manual MP-G10-TE - JUKI and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. MP-G10-TE by JUKI.

USER MANUAL MP-G10-TE JUKI

INDUSTRIAL SEWING MACHINE Attachment

MODEL

MP-G10-TE

TECHNICAL MANUAL

I/O Expansion Unit

FOR SAFE USE

Before the installation, operation, and inspection for this product, read the "FOR SAFE USE" and the technical manuals carefully. Also read the other technical manuals, "Sewing Machine Head", "Control Unit" and "Operation Panel" describing some instructions, which are not in this manual, and use the sewing machine properly.

SAFETY INDICATIONS

JUKI MP-G10-TE - SAFETY INDICATIONS - 1

CAUTION

Indicates that incorrect handling may cause hazardous conditions, resulting in medium or slight personal injury or physical damage. Note that CAUTION level may lead to a serious consequence according to the circumstances. Always follow the instructions of both levels because they are important to personal safety.

CAUTION INDICATIONS

No.Caution indicationDescription
1JUKI MP-G10-TE - CAUTION INDICATIONS - 1Precaution for sewing machine operation:Indicates that removing the safety and operating the sewing machine for some other purposes with power-on are prohibited.Please do not operate the sewing machine without protective equipment such as a needle guard, an eye guard, a belt cover or the others.Please turn off the power switch when threading, changing a needle and a bobbin, cleaning, and lubricating.
2JUKI MP-G10-TE - CAUTION INDICATIONS - 2Caution for fingers injury:Indicates a possibility of fingers (hands) injury in a certain condition.
3JUKI MP-G10-TE - CAUTION INDICATIONS - 3Caution for squeezing fingers:Indicates a possibility of squeezing fingers in a certain condition.

1. Features

This board expands the sum of the I/O ports of the PLK-G series.

12 input and 12 output ports in addition to the number of ports of Standard I/O can be expanded by installing this board.*1 *2

The setting of these expanded ports can be changed from the input/Output setting mode.

*1 It is not necessary to install the latest system software at PLK-G control unit.
*2 These outputs are for air valve only. The solenoid can not be driven.

JUKI MP-G10-TE - Features - 1

natural_image Technical line drawing of an applicable mechanical device with no visible text or symbols

2. Applicable models

PLK-G1010

3. Before use

It describes the parts structure and mounting method in this Technical Manual. Please see the Technical Manual "PLK-G2-TE" is how to set up and handling.

4. Configuration

The Fig. numbers in the drawing correspond to the part numbers given in the following explanations. When ordering service parts, please specify in the Parts No. (M*****).

4.1 I/O Expansion Unit

JUKI MP-G10-TE - I/O Expansion Unit - 1

text_image Technical diagram of an electronic device with numbered components, likely a control panel or enclosure.

4.1 I/O Expansion Unit (Parts list)

4.2 Accessories (Parts list)

5. Assembly procedures

JUKI MP-G10-TE - Assembly procedures - 1

CAUTION

★ When installing removal of parts, please go to turn off the power before. In addition, qualified personnel of electrical work, please be performed by wiring work.

5.1 Installing the I/O Expansion Unit

(1) Turn off the power.
(2) Remove the circuit board cover as shown in Figure 1.
(This cover is not used after the I/O Expansion Unit attached.)
(3) Disconnect the extension cable for the power supply of the circuit board.
(4) Remove the connector "SEN 1" from the connector mounting hole as shown in Figure 1.
(5) Fit the connector into the connector mounting hole on the I/O Expansion Unit "CON N" shown in Figure 2.
(6) Connect the extension cable and the connector "CON N".
(7) Connect the connector "SEN 2" of the I/O Expansion Unit and the connector "SEN 1" removed.
(8) Connect the connector "CON 2" of the circuit board and the signal line of the I/O Expansion Unit.
(9) Install the I/O Expansion Unit with a screw hole that had been fitted with the circuit board cover.

JUKI MP-G10-TE - Installing the I/O Expansion Unit - 1

text_image Circuit board cover SEN 1 connector mounting hole Extension cable

Fig.1

JUKI MP-G10-TE - Installing the I/O Expansion Unit - 2

flowchart
graph TD
    A["PLK-G2-SOL"] -->|CON P| B["Control unit"]
    A -->|SEN1| C["PLK-G2-TE"]
    A -->|SEN2| C
    A -->|CON N| C
    A -->|CON E| C
    A -->|CON C| C
    style A fill:#f9f,stroke:#333
    style B fill:#ccf,stroke:#333
    style C fill:#cfc,stroke:#333

Fig.2

5.2 How to set up and attached confirmation

JUKI MP-G10-TE - How to set up and attached confirmation - 1

CAUTION

Assembly of this device is completed, please check your work once again.

Because there is a case to unexpected behavior, please away from the sewing machine when the power is turned on and the air pressure.

(1) Please confirm if have finished the installation of the I/O Expansion Unit.
Please see the Technical Manual "PLK-G2-TE" is how to check this.
(2) The connection to the input and output ports, can be done by removing the Fig.No.106 cover.