DELTA DORE

DME 180 Tyxal+ - Motion detector DELTA DORE - Free user manual and instructions

Find the device manual for free DME 180 Tyxal+ DELTA DORE in PDF.

📄 7 pages English EN Download 💬 AI Question
Notice DELTA DORE DME 180 Tyxal+ - page 1
Pick your language and provide your email: we'll send you a specifically translated version.

User questions about DME 180 Tyxal+ DELTA DORE

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Motion detector in PDF format for free! Find your manual DME 180 Tyxal+ - DELTA DORE and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. DME 180 Tyxal+ by DELTA DORE.

USER MANUAL DME 180 Tyxal+ DELTA DORE

Outdoor motion detector

DELTA DORE DME 180 Tyxal+ - 1

DELTA DORE DME 180 Tyxal+ - 2

DELTA DORE DME 180 Tyxal+ - 3

natural_image Line drawing of a rectangular cabinet or storage unit with two doors, no text or symbols present

DELTA DORE DME 180 Tyxal+ - 4

  1. Contents
    DELTA DORE DME 180 Tyxal+ - 5

DELTA DORE DME 180 Tyxal+ - 6

DELTA DORE DME 180 Tyxal+ - 7
Instructions
Important Product Informations

DELTA DORE DME 180 Tyxal+ - 8

DELTA DORE DME 180 Tyxal+ - 9

2. Presentation

TYXAL+ DME 180 is a passive infrared motion detector, designed to detect the infrared radiation emitted by human bodies.

This motion detector aims to protect the outside of a building by detecting intrusions prior to penetration into the premises. As soon as a presence is detected, it raises the alarm.

TYXAL+ DME 180 has an automatic system to protect it against being opened or ripped from its mount.

It is also equipped with anti-masking detection, to prevent attempts to mask the lens.

2 installation heights are possible:

- low position, between 0.8 and 1.2 m: 180° detection, 12 m range.

- high position, 2 m: 180° detection, 9 m range.

- Paired with a control unit:

- alarm signal.

- pre-alarm signal: as soon as a person enters the protected zone, an audible and visual signal (outdoor siren) warns you of the imminent alarm.

Note

This product detects temperature differences between moving and background targets within the detection zone.

If the target remains motionless, the motion detector cannot detect it. This may affect the detector's maximum detection range.

3. Location

For optimal operation, please comply with the following recommendations:

In the event of non-compliance, the product may present malfunctions or may not function optimally.

DELTA DORE DME 180 Tyxal+ - Location - 1

2 installation heights are possible:

- low position, between 0.8 and 1.2 m: 180° detection, 12 m range.

- high position, 2 m : 180° detection, 9 m range.

  1. Location
    DELTA DORE DME 180 Tyxal+ - Location - 2

Install the motion detector vertically, with its high detection zones parallel to the ground.

If the detector is installed at an angle, detection reliability may be compromised.

An integrated spirit level enables optimal installation.

DELTA DORE DME 180 Tyxal+ - Location - 3

DELTA DORE DME 180 Tyxal+ - Location - 4

Install the motion detector vertically, with both high and low detection zones parallel to the wall.

DELTA DORE DME 180 Tyxal+ - Location - 5

To make sure the device functions properly, attach the motion detector to the wall.

DELTA DORE DME 180 Tyxal+ - Location - 6

Do not direct the detector towards moving objects (leaves, bushes, flags, etc.).

DELTA DORE DME 180 Tyxal+ - Location - 7

Do not direct the lower detection zone towards reflecting surfaces (puddle, window, etc.).

DELTA DORE DME 180 Tyxal+ - Location - 8

Do not install close to a heat pump or heat evacuation outlet (dryer, etc.).

4. Mounting

Wall-mounted On a post
Use screws and dowels that are compatible with the mount.
DELTA DORE DME 180 Tyxal+ - Mounting - 1

natural_image Simple line drawing of a device with a vertical panel and diagonal lines (no text or symbols)

You can mount it onto a post using clamps (not provided).
DELTA DORE DME 180 Tyxal+ - Mounting - 2

DELTA DORE DME 180 Tyxal+ - Mounting - 3
① Unlatch the top cover to open it.

DELTA DORE DME 180 Tyxal+ - Mounting - 4

natural_image Illustration of a hand inserting a component into a device (no text or symbols visible)

② Press on the "Push" strip to separate the detector from its base.

DELTA DORE DME 180 Tyxal+ - Mounting - 5

text_image 0.8-12 m ③ Secure the base using suitable screws. The tamper is trigger bottom is broken and wall.

DELTA DORE DME 180 Tyxal+ - Mounting - 6
Do not touch the mirrors.

DELTA DORE DME 180 Tyxal+ - Mounting - 7
Do not touch the lenses.

DELTA DORE DME 180 Tyxal+ - Mounting - 8

natural_image Line drawing of a hand holding a device with a cable, no text or symbols present

Only the blue parts are actionable.

5. Activation

DELTA DORE DME 180 Tyxal+ - Activation - 1

natural_image Hand holding a small electronic component with a magnified inset showing internal components (no text or symbols visible)

Plug the battery cable into the card connector. Set the (Tyxal+) alarm control panel to 'pending pairing', then press the pairing button on the card. Important: only the blue/green wires must be connected to the wireless car (and not the grey/yellow wires).

DELTA DORE DME 180 Tyxal+ - Activation - 2

natural_image Hand inserting a component into a device (no text or symbols visible)

② Reposition the sensor/electronic card on the base
Attention: lock the detector part by pushing the "Push" strip until you hear a "click".

③ Close the cover
DELTA DORE DME 180 Tyxal+ - Activation - 3

DELTA DORE DME 180 Tyxal+ - Activation - 4
4 A 3-minute detection test launches automatically. Check that you are detected by moving into the detection zone.

DELTA DORE DME 180 Tyxal+ - Activation - 5
⑤ With each detection, the LED flashes for 5 seconds.
Test mode automatically stops after 3 minutes and the system returns to "Normal" mode.

6. Detection zone settings

The detection zones from a to n can be easily masked by turning the masking shutter. The masking of a zone enables the prevention of false alarms.

DELTA DORE DME 180 Tyxal+ - Detection zone settings - 1

text_image Blue

DELTA DORE DME 180 Tyxal+ - Detection zone settings - 2

text_image a b c d e f g h i j k l m n

DELTA DORE DME 180 Tyxal+ - Detection zone settings - 3

text_image Diagram of a mechanical or electrical component with labeled parts (i-j) radiating from a central body.

DELTA DORE DME 180 Tyxal+ - Detection zone settings - 4

text_image Diagram of a mechanical device with labeled parts a, b, c and internal components, showing radial arrangement of dots.

Masking plate option

You have 5 masking plates to block out specidic detection zones. Example: masking of zone h.

DELTA DORE DME 180 Tyxal+ - Masking plate option - 1

text_image Technical diagram showing mechanical assembly steps with labeled components and directional arrows

DELTA DORE DME 180 Tyxal+ - Masking plate option - 2

text_image a b c d e f g i j k l m n n Zone h masked

7. Detector range settings for each side

Principle:

The high beam always remains parallel to the ground.

The low beam can be adjusted as shown below.

The range is limited by the angle of the low beam as the high and low beams must be intercepted simultaneously in order to activate the detector.

DELTA DORE DME 180 Tyxal+ - Principle: - 1

text_image Diagram illustrating vehicle detection scenarios with a car, a person, and a human silhouette, showing light paths and distance markers.

If the high beam alone is cut through: No detection

If only the low beam is intercepted: No detection

The high and low beams are intercepted: Detection

DELTA DORE DME 180 Tyxal+ - Principle: - 2

natural_image Close-up of a medical device with blue surgical tabs and a white plastic casing (no visible text or symbols)

The detection distance can be easily independently adjusted between 2.5 m and 12 m, by sliding the control button on the PIR.

For example: you can select 12 m on the left and 6 m on the right to adjust the installation to suit environmental constraints.

DELTA DORE DME 180 Tyxal+ - Principle: - 3

DELTA DORE DME 180 Tyxal+ - Principle: - 4

8. Detector range settings

Low mounting
DELTA DORE DME 180 Tyxal+ - Detector range settings - 1

text_image Right side 2.5 m (8 ft) 3.5 m (12 ft) 6.0 m (20 ft) 8.5 m (28 ft) 12.0 m (40 ft)

DELTA DORE DME 180 Tyxal+ - Detector range settings - 2

text_image Left side 2.5 m (8 ft.) 1.0 (3) 12.0 10.0 5.0 (42) (33) (17) 3.5 m (12 ft.) 12.6 10.6 5.0 6.0 m (20 ft.) 12.6 10.6 5.0 8.5 m (28 ft.) 12.6 10.6 5.0 12.9 m (40 ft.) 12.6 10.6 5.0 (1) (2) (3) (4) (5)

-8--9-
High mounting

If the detector is installed at a height of 2 m.

In this case, the detection distance is limited to max. 9 m.

DELTA DORE DME 180 Tyxal+ - Detector range settings - 3

text_image max. 9 m. 2.0 m (6°7') 3.0°7'1 10°25'1

You must perform the following steps:

① Position the cursor at L12/H9 (left side) and L40/H30 (right side).

② Reassembly the entire assembly to make the "HIGH MNT" marking appear.

DELTA DORE DME 180 Tyxal+ - Detector range settings - 4

text_image Diagram illustrating a step-by-step installation or assembly process with labeled components and directional arrows

9. Function settings

Detection sensitivity settings

DELTA DORE DME 180 Tyxal+ - Detection sensitivity settings - 1

text_image (L) (R) H M L

The sensitivity can be independently adjusted for each side, (L) left and (r) right, to 3 positions:

• L (low),
• M (medium),
• H (high).

The chosen position will depend on environmental conditions.

We recommend that you set the sensitivity level to H (high):

- When the detection beams were tilted horizontally.

- When higher sensitivity is required towards the end of the detection zone (12 m).

to L (low):

  • When the device is installed in a mediocre location (bad conditions).
  • When there is a high risk of faulty detection.

Switch settings

DELTA DORE DME 180 Tyxal+ - Switch settings - 1

text_image ON 1 2 3 4 5 6 7 8

The switches must be positioned towards the bottom during normal operation.

Switch 8: anti-masking function

  • OFF position: Function inactive
    • ON position: Function active
    The masking of the lens is indicated by an Auto-Protection fault.

10. Operation with an alarm system

• Association with an alarm system
- Pre-alarm
- Selection of triggering method
- Test

Read system installation guide

DELTA DORE DME 180 Tyxal+ - Operation with an alarm system - 1

II. Battery replacement

The LED flashes continuously, the battery is dead.
IMPORTANT: Before opening the unit, the alarm control unit must be in Maintenance mode (refer to system installation guide).

DELTA DORE DME 180 Tyxal+ - Battery replacement - 1

① Unlock the cover to open it.

DELTA DORE DME 180 Tyxal+ - Battery replacement - 2

natural_image Hand inserting a component into a device (no text or symbols visible)

② Press on the "Push" strip to separate the detector from its base.

  1. Troubleshooting
Problem Probab e causeSolution
The LED flashes continuously.Incorrect power supply.Change the battery.
Triggered detection without any objects movingThe motion detector was not installed perpendicularly to the ground.Install the motion detector correctly.
A reflecting object is located within the detection zone.Eliminate all reflecting surfaces from the detection zone.
The lower beam is longer than expected.Check and readjust the detection beam.
The lower detection beam is exposed to direct sun rays or to car headlights.Readjust the detection beam so it is no longer exposed to direct light sources.
Presence of a heat source (healing device, etc.) in the detection zone that may cause the temperature to change.Readjust the detection beam or eliminate the heat source in the detection zone.
An object is moving (washing hung up on a line, plants, etc.).Readjust the detection beam or remove moving objects.
In the event of heavy rain, water may pour through the detection zone (overflowing gutter, roof/terrace/balcony drainage, etc.)Readjust the detection beam so it is no longer directly exposed to the flowing water.
Occasionally no detection.Occasionally no detection.Readjust the detection beam correctly.
Sensitivity is set to L (low).Readjust the sensitivity level to M (medium) or H (high).

Caractéristiques techniques / Technical characteristics / Technische Daten Caratteristiche tecniche / Características técnicas / Technische kenmerken

DELTA DORE DME 180 Tyxal+ - Caractéristiques techniques / Technical characteristics / Technische Daten Caratteristiche tecniche / Características técnicas / Technische kenmerken - 12xLS 14500 - 3.6 V / 5.2 Ah - Lithium
DELTA DORE DME 180 Tyxal+ - Caractéristiques techniques / Technical characteristics / Technische Daten Caratteristiche tecniche / Características técnicas / Technische kenmerken - 2
Consumption stand-by : 19 μAConsumption : 4 mA max / 3,6 Vcc
DELTA DORE DME 180 Tyxal+ - Caractéristiques techniques / Technical characteristics / Technische Daten Caratteristiche tecniche / Características técnicas / Technische kenmerken - 3[868 - 868.6] MHz and [868.7 - 869.2] MHz100 m -> 300m
Maximum power radio < 10 mW,receiver category: 2
DELTA DORE DME 180 Tyxal+ - Caractéristiques techniques / Technical characteristics / Technische Daten Caratteristiche tecniche / Características técnicas / Technische kenmerken - 4-10°C / +70°C
[0.5±4]-30°C / +60°C
IPIP 55
[0.5±4]95%
[0.5±4]91,7 x 201,5 x 124,3 mmDELTA DORE DME 180 Tyxal+ - Caractéristiques techniques / Technical characteristics / Technische Daten Caratteristiche tecniche / Características técnicas / Technische kenmerken - 5 730 gr.