| Product Type | Dual Monitor Arm |
| Brand | Atdec |
| Model | AWMS-4640-C |
| Number of Monitors Supported | 2 |
| VESA Compatible | 75x75mm and 100x100mm |
| Maximum Weight Capacity per Monitor | 9 kg (20 lbs) |
| Mounting Options | Clamp and Grommet |
| Desk Thickness Range | 10-75 mm |
| Material | Steel and Aluminum |
| Color | Black |
| Height Adjustment Range | 0-450 mm |
| Tilt Range | -15° to +15° |
| Swivel Range | ±90° |
| Rotation | 360° |
| Cable Management | Integrated cable clips |
| Weight (approx.) | 5.2 kg (11.5 lbs) |
| Dimensions (Arm Length) | 464 mm each |
| Power Supply | None (mechanical) |
| Warranty | 10 years |
| Certifications | Complies with ANSI/BIFMA standards |
Frequently Asked Questions - AWMS-4640-C Atdec
User questions about AWMS-4640-C Atdec
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Monitor Stand in PDF format for free! Find your manual AWMS-4640-C - Atdec and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. AWMS-4640-C by Atdec.
USER MANUAL AWMS-4640-C Atdec
1 x 460 Arms on 400 Post with C-Clamp

natural_image
Technical line drawing of a mechanical clamp or bracket assembly (no text or symbols)COMPONENT CHECKLIST RANGE

natural_image
Mechanical arm component diagram showing articulated joints and a central hub (no text or symbols)A
AWM-A46
460 Arm
(x1)

B
AWM-P40
400 Post
(x1)

natural_image
Technical line drawing of a mechanical component with a central cavity and mounting base (no text or symbols)C
AWM-FC
C-Clamp
(x1)

CONTENTS
| C-Clamp | AWM-FC |
| Page 2 | Component Checklist |
| Page 3 | Clamp Installation |
| 400 Post | AWM-P40 |
| Page 6 | Component Checklist |
| Page 7 | Post Installation |
| 460 Arm | AWM-460 |
| Page 8 | Component Checklist |
| Page 9 | Arm Installation |
| Page 10 | Monitor Installation |
| Page 11 | Cable Management |

natural_image
Technical line drawing of a mechanical assembly with no visible text or symbols
natural_image
Technical line drawing of a mechanical component with a cylindrical shaft and base plate (no text or symbols)COMPONENT CHECKLIST REQUIRED TOOLS

natural_image
Technical line drawing of a 3-pin connector (no text or symbols)A
C Clamp Bracket (x1)

natural_image
Simple line drawing of a rounded rectangular object with a curved top and bottom edge (no text or symbols)C
Cover for Post (x1)

E
4mm Allen key (x1)

natural_image
Isometric line drawing of a mechanical part with four circular holes (no text or symbols)B
C Clamp Plate (x1)

natural_image
Simple line drawing of a mechanical part with a square flange and central hole (no text or symbols)D
Cover for Base (x1)

F
5mm Allen key (x1)
- All tools supplied
IMPORTANT INFORMATION
! Please ensure this product is installed as per these installation instructions.
! This product is compatible with Atdec modular (AWM) products.
! The manufacturer accepts no responsibility for incorrect installation.
1. C Clamp overview
1.1 Default - This is the "out of the box" configuration

natural_image
Technical line drawing of a mechanical component with housing and internal structure (no text or symbols)MIN THICKNESS - 25mm (1") MAX THICKNESS - 33mm (1 ^5 / _16 )
1.2 Inverted - The C Clamp can be reconfigured for thicker surfaces

natural_image
Technical line drawing of a mechanical component with mounting holes and a schematic diagram showing internal structure (no text or symbols)MIN THICKNESS - 18mm (1/8") MAX THICKNESS - 25.8mm (1")
2. Re-configure Clamp
2.1 Slide pad off

natural_image
Pure diagram of a pipe with an arrow indicating direction, no text or symbols present2.3 Invert pad

flowchart
graph TD
A["Process Step"] --> B["Output"]
style A fill:#fff,stroke:#000
style B fill:#fff,stroke:#000
2.3 Slide pad back on

natural_image
Pure diagram of a mechanical or fluidic system with arrows indicating direction, no text or symbols present3. Post mount configuration
3.1 Attach plate to post

text_image
Fasteners supplied with post Tighten Firmly3.2 Place in desired location

natural_image
Technical line drawing of a mechanical assembly with a base and mounting bracket (no text or symbols)3.3 Slide the C Clamp bracket over the plate and position screw tips in the indents on the base plate

natural_image
Mechanical assembly diagram showing a rotating component with directional arrows, no text or symbols presentNote: You may need to un-screw the set screws out of the plate using the allen key
3.4 Check the set screws are mounted in position. Also check the desk clamp bracket is positioned tight up against the mounting surface edge

text_image
M8 x 16mm Set Screw Desk Clamp Bracket Mounting surface Pad3.5 Tighten the set screws firmly and evenly on both sides of the desk clamp bracket.

natural_image
Technical line drawing of a mechanical assembly with two circular components and a rod (no text or symbols)4. Installing the clamp cover to post
4.1 Remove the cable cover by pulling it straight up and out of the post. Remove top cap if already installed

natural_image
Diagram of a device with an upward arrow and component structure, no visible text or symbols4.2 Locate the C Clamp cover over the post. Guide over the holes in the base plate and gently apply pressure on the cover until it clicks into place

text_image
Click!4.3 Re-attach the cable cover by sliding it into the post channel. Fit the pole and cover caps back on.

natural_image
Technical line drawing of a vertical mechanical device with a black arrow indicating downward motion (no text or symbols)5. Base mount installation
5.1 Attach plate to base

text_image
Fasteners supplied with base Tighten Firmly5.2 Place the base and plate in desired location

natural_image
Technical line drawing of a mechanical mounting bracket with bolted base and flange (no text or symbols)5.3 Slide the bracket onto the base plate and position screw tips in the indents on the base plate

natural_image
Mechanical assembly diagram showing a rotating component with a magnified inset (no text or symbols)Note: You may need to un-screw the set screws out of the plate using the allen key
5.4 Check the set screws are mounted in position. Also check the desk clamp bracket is positioned tight up against the mounting surface edge

text_image
M8 x 16mm Set Screw Desk Clamp Bracket Mounting surface Pad5.5 Tighten the set screws firmly and evenly on both sides of the desk clamp bracket

natural_image
Technical line drawing of a mechanical assembly with a cylindrical component and rotating parts (no text or symbols)6. Installing the clamp cover to base
6.1 Locate the Cover for Base over the base. Guide over the holes in the base plate and gently apply pressure on the cover until it clicks into place.

text_image
Click!6.2 Installation Complete
To continue with installation of your monitor arm, refer to your monitor arm's installation guide.

natural_image
Mechanical assembly diagram showing a hand pressing a cylindrical component into a base (no text or symbols)
natural_image
Line drawing of a cylindrical device with a lid and internal components, shown against a curved background (no text or symbols)COMPONENT CHECKLIST

natural_image
Technical line drawing of a symmetrical mechanical component with no text or symbolsA
Post (x1)

B
Post Cap (x1)

C
Screw M8 (x2)

D
Cable Cover Cap (x1)
(not supplied with all posts)

E
Cable Cover (x1) (not supplied with all posts)

F
Cable clips
(not supplied
with all posts)

REQUIRED TOOLS
- All tools provided
IMPORTANT INFORMATION
! Please ensure this product is installed as per these installation instructions.
! This product is compatible with Atdec AWM Series products.
! The manufacturer accepts no responsibility for incorrect installation.
1. Attach Post to fixing (fixing sold separately)
1.1 Follow the installation guide provided with your fixing to attach it to the post and fit it to the worksurface.

AWM Fixing options

Bolt Through Kit
AWM-FB

F Clamp
AWM-FF

Heavy Duty
F Clamp
AWM-FH

C Clamp
AWM-FC

Grommet Clamp AC-GC
2. Check post placement & arm positions
2.1 Do not mount a monitor arm on the rear channel of a post when the post is fixed to the desk using an F Clamp, Heavy Duty F Clamp, or C Clamp.

F Clamp
AWM-FF

Heavy Duty
F Clamp
AWM-FH

C Clamp
AWM-FC

text_image
Rear of Mounting Surface3. Cable cover position and post cap
3.1 To reposition the cable cover, pull it straight up and out of the post and insert it into any of the available channels

text_image
Cable CoverNote: The cable cover shown does not come with all posts
3.2 Optional cable cover positions

natural_image
Top-down line drawing of a symmetrical mechanical or architectural component with no text or symbols3.3 Fit post cap onto the top of the post

text_image
Technical diagram showing a mechanical assembly with labeled parts and directional arrows indicating assembly steps.Allen Key
Post Cap
Note: An allen key may be stored in the Post Cap.
Post
4. Cable clips and cover
4.1 Push the cable down into the cable clip.

natural_image
Close-up of hands connecting a cable to a connector (no text or symbols visible)Note: Cable clips do not come with all posts. Additional clips sold separately.
4.2 Insert one side of the cable clip into the channel on the post assembly, then push in the other side.

natural_image
Illustration of a hand inserting a cable into a plastic housing (no text or symbols visible)4.3 Loop cable and insert into cable cover.

natural_image
Illustration of hands tying a knot between two vertical strips (no text or symbols)4.4 Feed remaining cable into the cover.

natural_image
Diagram of a joint with a bandage and handle, no text or symbols present
natural_image
Technical line drawing of a mechanical linkage assembly (no text or symbols)COMPONENT CHECKLIST

natural_image
Technical line drawing of a mechanical bracket or clamp (no text or symbols)A
Monitor Arm (x1)

B
VESA Head (x1)

C
Post Clamp
(x1)



E
Screw
M4x16mm
(x4)
F
Screw
M4x12mm
(x4)
D
Screw
M4x25mm
(x4)



G
Spacer
(x4)
H
Security
screw
(x1)
|
4mm
allen key
(x1)

REQUIRED TOOLS
• Phillips Head Screwdriver
WEIGHT RANGE

0 - 12kg (0 - 26.5lbs)
IMPORTANT INFORMATION
! Please ensure this product is installed as per these installation instructions.
! The manufacturer accepts no responsibility for incorrect installation.
! This product is compatible with Atdec AWM Series products.
1. Fix clamp to Post or Wall Channel

text_image
1.1 Ensure knob is undone. 1.2 Slide post clamp into channel. Push knob to aid insertion 1.3 Hold clamp in desired position on channel and turn knob to lock in place.2. Set arm rotation to 180^ (optional)
Note rotation is set to 360^ by default.

text_image
2.1 Remove plastic sleeve from post clamp. 2.2 Remove rotation ring. 2.3 Place rotation ring in desired position. Default Position 360° OR 180° Flipped Position Note: rotation ring placement depends on the position of the clamp on the post. The tag on the ring should always face toward the user. 1. Press 2. Lift 1. Press3. Fit arm onto post clamp

text_image
3.1 Push arm onto shaft. 3.2 Ensure arm is fully pushed onto shaft. 3.3 Tighten joint screw. Note: Check the arm rotation is smooth after tightening.4. Attach VESA head to monitor
4.1 VESA mounting compatibility

text_image
100mm 75mm 100mm 75mmNote: For other sizes, use a suitable adaptor plate (sold separately).
4.2 Screw the VESA head onto monitor

natural_image
Pure mechanical diagram of a star-shaped component with mounting holes and internal components (no text or symbols)Note spacers may be required for curved, recessed or uneven monitor surfaces.
4.3 Ensure the correct screw length is used to attach the monitor.

text_image
5mm 12mm Flush Spacer Too long Too short5. Mount monitor
5.1 Insert VESA head into the monitor arm

text_image
Monitor arm5.2 Ensure that the VESA head sits flush within the monitor arm. There should be no gap

text_image
Gap No gap5.3 Push the lever down to secure it to the arm assembly

natural_image
Diagram of a hand pressing down on a mechanical component with a downward arrow indicating force or direction (no text or symbols present)6. Adjust tilt tension & Install security screw
6.1 Use the allen key to adjust the tilt tension until the monitor holds in a vertical position at the end of the arm.

text_image
Note: Support monitor while adjusting. Loosen Tighten6.2 OPTIONAL security screw
To install the optional security screw tilt the head upwards

natural_image
Diagram of a mechanical component with an arrow indicating rotation, no text or symbols present6. Monitor arm cable management
6.1 Plug cables into the monitor and route the cables down the arm using the cable hooks and clips

text_image
the monitor and route e arm using the cable Note Ensure enough cable slack is given to allow for movement of the monitor7. Post cable management
7.1 Push the cable down into the cable clip

text_image
Note: Cable clips do not come with all posts7.2 Push cable clip into post channel

natural_image
Illustration of a hand inserting a cable into a mechanical component (no text or symbols)7.3 Recommended post cable cover position for double or triple arm set-ups

text_image
Cable Cover Desk Clamp7.4 To reposition the cable cover, pull it straight up and out of the post and insert it into any of the available channels

text_image
Cable coverNote: The cable cover shown does not come with all posts

natural_image
Top-down line drawing of a symmetrical mechanical or architectural component with no text or symbolsAlternative cable cover positions
7.5 Loop cable and insert into cable cover

natural_image
Illustration of hands tying a knot between two vertical strips (no text or symbols)7.6 Feed remaining cable into cover