ASUS

TS100-E4/PI2 - Server ASUS - Free user manual and instructions

Find the device manual for free TS100-E4/PI2 ASUS in PDF.

📄 158 pages English EN Download 💬 AI Question
Notice ASUS TS100-E4/PI2 - page 7
Pick your language and provide your email: we'll send you a specifically translated version.

User questions about TS100-E4/PI2 ASUS

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Server in PDF format for free! Find your manual TS100-E4/PI2 - ASUS and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. TS100-E4/PI2 by ASUS.

USER MANUAL TS100-E4/PI2 ASUS

natural_image Black desktop computer tower with visible drive bays and ventilation slots (no text or labels)

E2791

First Edition V1.00

February 2007

Copyright 2007© ASUSTeK COMPUTER INC. All Rights Reserved.

No part of this manual, including the products and software described in it, may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form or by any means, except documentation kept by the purchaser for backup purposes, without the express written permission of ASUSTeK COMPUTER INC. ("ASUS").

ASUS provides this manual “as is” without warranty of any kind, either express or implied, including but not limited to the implied warranties or conditions of merchantability or fitness for a particular purpose. In no event shall ASUS, its directors, officers, employees, or agents be liable for any indirect, special, incidental, or consequential damages (including damages for loss of profits, loss of business, loss of use or data, interruption of business and the like), even if ASUS has been advised of the possibility of such damages arising from any defect or error in this manual or product.

Specifications and information contained in this manual ae furnished for informational use only, and are subject to change at any time without notice, and should not be construed as a commitment by ASUS. ASUS assumes no responsibility or liability for any errors or inaccuracies that may appear in this manual, including the products and software described in it.

Product warranty or service will not be extended if: (1) the product is repaired, modified or altered, unless such repair, modification of alteration is authorized in writing by ASUS; or (2) the serial number of the product is defaced or missing.

Products and corporate names appearing in this manual may or may not be registered trademarks or copyrights of their respective companies, and are used only for identification or explanation and to the owners' benefit, without intent to infringe.

Contents

Notices ......vii

Safety information ......viii

About this guide ix

Chapter 1: Product introduction

1.1 System package contents 1-2
1.2 System specifications 1-3
1.3 Front panel features 1-5
1.4 LED information 1-6
1.5 Rear panel features 1-6
1.6 Internal features 1-7

Chapter 2: Hardware setup

2.1 Removing the side cover 2-2
2.2 Motherboard information 2-4
2.3 Central Processing Unit (CPU) 2-5
2.3.1 Installing the CPU 2-5
2.3.2 Installing the CPU heatsink 2-7

2.4 System memory 2-9
2.4.1 Overview 2-9
2.4.2 Memory configurations 2-9
2.4.3 Installing a DIMM 2-10
2.4.4 Removing a DIMM 2-10

2.5 Installing a hard disk drive 2-11

2.6 Installing 5.25-inch drives 2-15
2.6.1 Removing the front panel cover 2-15
2.6.2 Installing additional optical drive(s) 2-17

2.7 Installing expansion cards 2-19

2.8 Removing components 2-21
2.8.1 Removing the floppy disk drive 2-21
2.8.2 Removing/Add the chassis fan (Optional) 2-22

2.9 Connecting cables 2-23

2.10 Replacing the side cover 2-24

Chapter 3: Motherboard Info

3.1 Motherboard overview 3-2

Contents

3.2 Jumpers 3-5
3.3 Connectors 3-10

3.3.1 Rear panel connectors 3-10
3.3.2 Internal connectors 3-11

Chapter 4: BIOS Setup

4.1 Managing and updating your BIOS 4-2

4.1.1 Creating a bootable floppy disk 4-2
4.1.2 AFUDOS utility.... 4-3
4.1.3 ASUS CrashFree BIOS 2 utility.... 4-6
4.1.4 ASUS Update utility 4-8

4.2 BIOS setup program 4-11

4.2.1 BIOS menu screen 4-12
4.2.2 Menu bar 4-12
4.2.3 Navigation keys 4-12
4.2.4 Menu items 4-13
4.2.5 Sub-menu items 4-13
4.2.6 Configuration fields 4-13
4.2.7 Pop-up window 4-13
4.2.8 Scroll bar 4-13
4.2.9 General help 4-13

4.3 Main menu 4-14

4.3.1 System Time [xx:xx:xx] 4-14
4.3.2 System Date [Day xx/xx/xxxx] 4-14
4.3.3 Legacy Diskette A [Enabled] 4-14
4.3.4 Primary, Third, Fourth IDE Master/Slave 4-15
4.3.5 IDE Configuration 4-16
4.3.6 System Information 4-18

4.4 Advanced menu 4-19

4.4.1 USB Configuration 4-19
4.4.2 MPS Configuration 4-20
4.4.3 Remote Access Configuration 4-21
4.4.4 Trusted Computing 4-22
4.4.5 CPU Configuration 4-23
4.4.6 Chipset 4-24

Contents

4.4.7 Onboard Devices Configuration 4-26
4.4.8 PCI PnP 4-27

4.5 Power Configuration 4-28

4.5.1 APM Configuration 4-28
4.5.2 Hardware Monitor 4-30

4.6 Boot menu 4-31

4.6.1 Boot Device Priority 4-32
4.6.2 Hard Disk Drives 4-32
4.6.3 Boot Settings Configuration 4-33
4.6.4 Security 4-34

4.7 Exit menu 4-37

Chapter 5: RAID Configuration

5.1 RAID configurations 5-2

5.1.1 RAID definitions 5-2
5.1.2 Installing Serial ATA hard disks 5-3
5.1.3 Setting the RAID item in BIOS 5-3
5.1.4 RAID configuration utility 5-3

5.2 Intel ^® Matrix Storage Manager Option ROM Utility 5-4

5.2.1 Creating a RAID 0 set (striped) 5-5
5.2.2 Creating a RAID 1 set (mirrored) 5-7
5.2.3 Deleting a RAID set 5-8
5.2.4 Resetting Disks to Non-RAID 5-9
5.2.5 Exiting the Intel ^® Matrix Storage Manager utility ..... 5-9
5.2.6 Rebuilding the RAID 5-10
5.2.7 Setting the Boot array in the BIOS Setup Utility ..... 5-11

5.3 LSI Logic Embedded SATA RAID Setup Utility ....5-12

5.3.1 Creating a RAID set 5-13
5.3.2 Adding or viewing a RAID configuration 5-19
5.3.3 Initializing the logical drives 5-22
5.3.4 Rebuilding failed drives 5-27
5.3.5 Checking the drives for data consistency 5-29
5.3.6 Deleting a RAID configuration 5-32
5.3.7 Selecting the boot drive from a RAID set 5-33
5.3.8 Enabling the WriteCache 5-34

Contents

5.4 Global Array Manager 5-34

Chapter 6: Driver installation

6.1 RAID driver installation 6-2

6.1.1 Creating a RAID driver disk.... 6-2
6.1.2 Installing the RAID controller driver 6-3

6.2 LAN driver installation 6-13

6.2.1 Windows ^® 2003 Server 6-13
6.2.2 Red Hat ^® Enterprise ver. 3.0 6-14

6.3 VGA driver installation 6-15

6.3.1 Windows ^® 2003 Server 6-15
6.3.2 Red Hat ^® Enterprise ver. 3.0 6-15

6.4 Management applications and utilities installation ......6-16

6.4.1 Running the support CD 6-16
6.4.2 Drivers menu 6-16
6.4.3 Management Software menu 6-17
6.4.4 Utilities menu 6-17
6.4.5 Contact information 6-17

Appendix: Reference information

A.1 Intel ^® EM64T ...... A-2
A.2 Enhanced Intel SpeedStep® Technology (EIST) ...... A-2

A.2.1 System requirements ...... A-2
A.2.2 Using the EIST ...... A-3

A.3 Block diagram ...... A-4

A.4 250W single power supply ...... A-5

A.4.1 General description ...... A-5
A.4.2 Specifications ...... A-6

Notices

Federal Communications Commission Statement

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  • This device may not cause harmful interference, and
  • This device must accept any interference received including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with manufacturer's instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

ASUS TS100-E4/PI2 - Federal Communications Commission Statement - 1

WARNING! The use of shielded cables for connection of the monitor to the graphics card is required to assure compliance with FCC regulations. Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.

Canadian Department of Communications Statement

This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.

This Class A digital apparatus complies with Canadian ICES-003.

Safety information

Electrical Safety

  • Before installing or removing signal cables, ensure that the power cables for the system unit and all attached devices are unplugged.
  • To prevent electrical shock hazard, disconnect the power cable from the electrical outlet before relocating the system.
  • When adding or removing any additional devices to or from the system, ensure that the power cables for the devices are unplugged before the signal cables are connected. If possible, disconnect all power cables from the existing system before you add a device.
  • If the power supply is broken, do not try to fix it by yourself. Contact a qualified service technician or your dealer.

Operation Safety

  • Any mechanical operation on this server must be conducted by certified or experienced engineers.
  • Before operating the server, carefully read all the manuals included with the server package.
  • Before using the server, make sure all cables are correctly connected and the power cables are not damaged. If any damage is detected, contact your dealer as soon as possible.
  • To avoid short circuits, keep paper clips, screws, and staples away from connectors, slots, sockets and circuitry.
  • Avoid dust, humidity, and temperature extremes. Place the server on a stable surface.

ASUS TS100-E4/PI2 - Operation Safety - 1

This product is equipped with a three-wire power cable and plug for the user's safety. Use the power cable with a properly grounded electrical outlet to avoid electrical shock.

Lithium-Ion Battery Warning

CAUTION! Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions.

CD-ROM Drive Safety Warning

CLASS 1 LASER PRODUCT

Heavy System

CAUTION! This server system is heavy. Ask for assistance when moving or carrying the system.

About this guide

Audience

This user guide is intended for system integrators, and experienced users with at least basic knowledge of configuring a server.

Contents

This guide contains the following parts:

  1. Chapter 1: Product Introduction

This chapter describes the general features of the server, including sections on front panel and rear panel specifications.

  1. Chapter 2: Hardware setup

This chapter lists the hardware setup procedures that you have to perform when installing or removing system components.

  1. Chapter 3: Motherboard information

This chapter gives information about the motherboard that comes with the server. This chapter includes the motherboard layout, jumper settings, and connector locations.

  1. Chapter 4: BIOS information

This chapter tells how to change system settings through the BIOS Setup menus and describes the BIOS parameters.

  1. Chapter 5: RAID configuration

This chapter tells how to change system settings through the BIOS Setup menus. Detailed descriptions of the BIOS parameters are also provided.

  1. Chapter 6: Driver installation

This chapter provides instructions for installing the necessary drivers for different system components.

  1. Appendix: Reference information

This appendix includes additional information that you may refer to when configuring the motherboard.

Conventions

To make sure that you perform certain tasks properly, take note of the following symbols used throughout this manual.

ASUS TS100-E4/PI2 - Conventions - 1

WARNING: Information to prevent injury to yourself when trying to complete a task.

ASUS TS100-E4/PI2 - Conventions - 2

CAUTION: Information to prevent damage to the components when trying to complete a task.

ASUS TS100-E4/PI2 - Conventions - 3

IMPORTANT: Instructions that you MUST follow to complete a task.

ASUS TS100-E4/PI2 - Conventions - 4

NOTE: Tips and information to aid in completing a task.

Typography

Bold text Indicates a menu or an item to select.

Italics Used to emphasize a word or a phrase.

Keys enclosed in the less-than and greater-than sign means that you must press the enclosed key.

Example: means that you must press the Enter or Return key.

++ If you must press two or more keys simultaneously, the key names are linked with a plus sign (+).

Example: ++

Command Means that you must type the command exactly as shown, then supply the required item or value enclosed in brackets.

Example: At the DOS prompt, type the command line:

format A:/S

References

Refer to the following sources for additional information, and for product and software updates.

  1. ASUS Server Web-based Management (ASWM) user guide

This manual tells how to set up and use the proprietary ASUS server management utility.

  1. ASUS websites

The ASUS websites worldwide provide updated information for all ASUS hardware and software products. Refer to the ASUS contact information.

Chapter 1

This chapter describes the general features of the barebone server, including sections on the front panel and rear panel specifications.

ASUS TS100-E4/PI2 - Chapter 1 - 1

natural_image Black desktop computer tower with visible drive bays and ventilation slots (no text or labels)

product integration

1.1 System package contents

Check your ASUS TS100-E4/PI2 package with the items on the following table. The package contents vary for the following configurations:

Check your system package for the following items.

Chassis ASUS T10 Non-rackable Tower chassis

Motherboard ASUS P5M2-M/C_TS100-E4 motherboard

Components 250W Single power supply (110 /230V Switching Selection)

1 x Standard 16x DVD-ROM or standard DVD-RW (Optional)

Active CPU Cooler

Cables AC power cable

SATA cables

SATA power cable

IDE cable

FDD cable

System cables

Accessories TS100-E4/PI2 user guide

TS100-E4/PI2 support CD (includes ASWM*)

CA Anti-virus software CD

Bag of screws

* ASUS System Web-based Management

ASUS TS100-E4/PI2 - System package contents - 1

Contact your dealer immediately if any of the items is damaged or missing.

1.2 System specifications

The ASUS TS100-E4/PI2 is a server system featuring the ASUS P5M2-M/C_TS100-E4 motherboard. The server supports the Intel ^ Xeon ^ 3000/3200 or Pentium ^ D (D-stepping) series Processors, and includes the latest technologies through the chipsets embedded on the motherboard.

Chassis T10 non-radkable Tower Chassis
Motherboard ASUS PP5M2-M/C_TS100-E4
Chipset NorthBridgeIntel ^ Xeon 3000 chipset (Mukilteo-2)SouthBridge: Intel ^ ICH7R
CPU LGA775 socketfor Intel ^ Xeon ^ 3000/3200 or Pentium ^ D(D-stepping) series processorsSupports Intel ^ Enhanced Memory 64 Technology (EM64T)Supports Enhanced Intel SpeedStep ^ Technology (EIST)
Memory Dual-channelmemory architecture4 x 240-pin DIMM sockets support unbufferedECC/non-ECC DDR2-533/667 memory modulesSupports up to 8 GB system memory
LAN Single embeddedBroadcom BCM5721 Gigabit LAN controllers thatcomply with PCI Express 1.0a specifications
VGA XGI Volari ^ PCI-based VGA controller with 32 MB memory
StorageIntel ^ ICH7R Southbridge supports:- 2 x SATAII 300MB/s drivers with RAID functionality using theIntel Matrix Storage Manager (IMSM)(RAID 0, RAID 1), or theLSI Logic Embedded SATA RAID controller (RAID 0, RAID 1)
Expansion slots1 x PCIe x8 Slot (x4 Link) (PCI E1 slot)1 x PCIe x8 Slot (x8 Link) (PCI E2 slot)2 x PCI 32bit/33MHz 5V Slots1 x SO-DIMM socket for ASUS Server Management Board
Front panel4 x 5.25" Space for max of 2* IDE device (Option: DVD-ROM orDVD-RW)2 x USB 2.0 ports1 x FDDPower switchReset switchLEDs: Power, HDD access
Rear panel1 x PS/2 keyboard port (purple)1 x PS/2 mouse port (green)2 x USB 2.0 ports1 x Parallel port1 x Serial port (COM1)1 x VGA port1 x LAN (RJ-45) port
Management ASUS $Server Web-based Management (ASWM 2.0)
Hardware support (optional)SM-Bus, ASMB3-SOL support IPMI 2.0 Over LAN management card
Hardware monitorsVoltage, temperature, and fan speed monitoringAutomatic System Restart (ASR) feature
Power supply 250Wsingle power supply, 100V~130Vac/200~260Vac by switching setting; 50Hz~60Hz, 24pin + 4pin power connector
Dimensions 192 mm(W) x 490 mm (D) x 426 mm (h)
Net Weight 13.5 kg

(continued on the next page)

ASUS TS100-E4/PI2 - System specifications - 1

Refer to "Chapter 3 Motherboard information" for details on the internal connectors.

1.3 Front panel features

The TS100-E4/PI2 chassis displays a black stylish front panel.

The power button, LED indicators, optical, and floppy drives are located on the front panel. Flip the front panel I/O ports cover to access the front panel USB ports.

Front panel 1/0 ports cover

ASUS TS100-E4/PI2 - Front panel features - 1

natural_image Black desktop computer tower with visible drive bays and ventilation slots (no text or labels)

ASUS TS100-E4/PI2 - Front panel features - 2

text_image Optical drive Empty 5.25-inch bays Floppy disk drive USB ports HDD LED Power button and LED Reset button

1.4 LED information

The TS100-E4/PI2 comes with two LED indicators. Refer to the picture for the LED location and the table below for LED description.

ASUS TS100-E4/PI2 - LED information - 1

natural_image Close-up of a desktop computer tower case with indicator lights and power button (no text or symbols visible)
LED Icon Display Description
Drive Activity LED Blinking Read/write data into the HDD
Power LED ON System power ONBlinking Suspend mode

1.5 Rear panel features

The rear panel includes a slot for the motherboard rear I/O ports, four full-length expansion slots, chassis cover locks, a vent for the system fan, and the power supply unit.

ASUS TS100-E4/PI2 - Rear panel features - 1

text_image Voltage selector Power connector P/S2 mouse port P/S2 keyboard port USB 2.0 ports Serial port Parallel port VGA port Gigabit LAN ports Power supply unit Power Switch Space for 9 cm system FAN if needed 4 expansion slots

1.6 Internal features

The TS100-E4/PI2 chassis includes the basic components as shown.

ASUS TS100-E4/PI2 - Internal features - 1

text_image Internal view of a computer motherboard with numbered components and labeled connectors
  1. Power supply
  2. Space for 9 cm system FAN
  3. ASUS P5M2-M/C_TS100-E4
  4. CPU socket and CPU Cooler
  5. DDR2 DIMM sockets
  6. PCI Express x8 slot (x4 Link)
  7. PCI Express x8 slot (x8 Link)
  8. 2 x PCI slots

  9. Floppy disk drive connector

  10. IDE connector
  11. Serial ATA connectors
  12. Optical drive (Standard/Optional)
  13. Empty 5.25-inch drive bays
  14. Floppy disk drive
  15. HDD bay
  16. Detachable HDD cage

ASUS TS100-E4/PI2 - Internal features - 2

The hard disk drives are purchased separately.

Chapter 2

This chapter lists the hardware setup procedures that you have to perform when installing or removing system components.

ASUS TS100-E4/PI2 - Chapter 2 - 1

natural_image Black desktop computer tower with visible drive bays and ventilation slots (no text or labels)

Hardware setup

2.1 Removing the side cover

To remove the side cover:

  1. Use a Philips screwdriver to remove the screw on the side cover.
  2. Locate the two side cover locks.

ASUS TS100-E4/PI2 - Removing the side cover - 1

text_image Diagram showing a server rack with labeled components and a magnified view of the main component being inserted into a wall.
  1. Press the side cover I outward, then pull the side cover toward the rear panel for about one-half inch.

ASUS TS100-E4/PI2 - Removing the side cover - 2

text_image ocks 3
  1. Move the side cover to the direction of the arrow.
  2. Lift the side cover, then set aside.

ASUS TS100-E4/PI2 - Removing the side cover - 3

text_image Diagram showing a hand pressing a computer tower with blue arrows indicating press direction and a numbered label '4' pointing to the tower.

ASUS TS100-E4/PI2 - Removing the side cover - 4

- Make sure that you unplug the power cord before removing the side cover.

• Take extra care when removing the side cover. Keep your fingers from components inside the chassis that can cause injury, such as the CPU fan, rear fan, and other sharp-edged parts.

Viewing the internal structure

Without the side cover, the internal structure and installed components of the barebone server appear as shown in the following picture.

Perform the procedures in the succeeding sections to install the CPU, system memory, disk drives, and expansion cards.

ASUS TS100-E4/PI2 - Viewing the internal structure - 1

natural_image Internal view of a computer tower case showing internal components like CPU, RAM slots, and motherboard (no visible text or labels)

2.2 Motherboard information

Place eight (8) screws into the holes indicated by circles to secure the motherboard to the chassis.

ASUS TS100-E4/PI2 - Motherboard information - 1

Refer to "Chapter 3 Motherboard Information" for detailed Information.

ASUS TS100-E4/PI2 - Motherboard information - 2

text_image Place this side towards the rear of the chassis P5M2-M/C_TS100-E4 ASUS

ASUS TS100-E4/PI2 - Motherboard information - 3

Make sure to unplug the power cord before installing or removing the motherboard. Failure to do so can cause you physical injury and damage motherboard components.

2.3 Central Processing Unit (CPU)

The motherboard comes with a surface mount LGA775 socket designed for the Intel® Xeon® 3000/3200 or Pentium D series processors in the 775-land package.

ASUS TS100-E4/PI2 - Central Processing Unit (CPU) - 1

  • Upon purchase of the motherboard, make sure that the PnP cap is on the socket and the socket contacts are not bent. Contact your retailer immediately if the PnP cap is missing, or if you see any damage to the PnP cap/socket contacts/motherboard components. ASUS shoulders the repair cost only if the damage is shipment/transit-related.
  • Keep the cap after installing the motherboard. ASUS will process Return Merchandise Authorization (RMA) requests only if the motherboard comes with the cap on the LGA775 socket.
  • The product warranty does not cover damage to the socket contacts resulting from incorrect CPU installation/removal, or misplacement/loss/incorrect removal of the PnP cap.

2.3.1 Installing the CPU

To install a CPU:

  1. Locate the CPU socket on the motherboard.

ASUS TS100-E4/PI2 - Installing the CPU - 1

text_image PSM2-MVC_TS100-E4 A/83.56

P5M2-M/C_TS100-E4 CPU Socket 775

ASUS TS100-E4/PI2 - Installing the CPU - 2

Before installing the CPU, make sure that the cam box is facing towards you and the load lever is on your left.

  1. Press the load lever with your thumb (A), then move it to the left (B) until it is released from the retention tab.

ASUS TS100-E4/PI2 - Installing the CPU - 3

text_image Retention tab Load lever A PnP cap B This side of the socket box should face you.

ASUS TS100-E4/PI2 - Installing the CPU - 4

To prevent damage to the socket pins, do not remove the PnP cap unless you are installing a CPU.

  1. Lift the load lever in the direction of the arrow to a 135^ angle.

ASUS TS100-E4/PI2 - Installing the CPU - 5

natural_image Close-up of a metallic electronic component with blue and black markings, no visible text or symbols
  1. Lift the load plate with your thumb and forefinger to a 100^ angle (A), then push the PnP cap from the load plate window to remove (B).

ASUS TS100-E4/PI2 - Installing the CPU - 6

text_image Load plate A B
  1. Position the CPU over the socket, making sure that the gold triangle is on the bottom-left corner of the socket. The socket alignment key should fit into the CPU notch.

ASUS TS100-E4/PI2 - Installing the CPU - 7

text_image d h e Alignment key Gold triangle mark
  1. Close the load plate (A), then push the load lever (B) until it snaps into the retention tab.

ASUS TS100-E4/PI2 - Installing the CPU - 8

natural_image Close-up of a computer processor component with blue arrows indicating rotation (no text or symbols)

ASUS TS100-E4/PI2 - Installing the CPU - 9

The CPU fits in only one correct orientation. DO NOT force the CPU into the socket to prevent bending the connectors on the socket and damaging the CPU!

2.3.2 Installing the CPU heatsink

The Intel ^® Xeon 3200/3000 or Pentium D processors require an Intel certified or ASUS qualified heatsink to ensure optimum thermal condition and performance.

When you buy a boxed Intel CPU, the package includes the heatsink, fan, retention brackets, screws, thermal grease, installation manual, and other items that are necessary for CPU installation.

ASUS TS100-E4/PI2 - Installing the CPU heatsink - 1

  • Make sure that you have applied the thermal grease to the top of the CPU before installing the heatsink and fan.
  • Refer to the installation manual that came with the CPU package for details on heatsink/fan assembly and installation.
  • For installation instruction of bundled ASUS qualified CPU heatsink and fan assembly, refer to section 3.2.

To install the CPU heatsink and fan:

  1. Place the heatsink on top of the installed CPU, making sure that the CPU fan screws match the holes on the motherboard.

ASUS TS100-E4/PI2 - Installing the CPU heatsink - 2

text_image CPU fan screw hole CPU fan screw

ASUS TS100-E4/PI2 - Installing the CPU heatsink - 3

- Orient the heatsink and fan assembly such that the CPU fan cable is closest to the CPU_FAN1 connector.

- An X-pad™ comes pre-installed under the motherboard.

  1. Fasten the screws in a diagonal sequence to secure the heatsink and fan assembly in place.

ASUS TS100-E4/PI2 - Installing the CPU heatsink - 4

flowchart
graph TD
    A1["A"] --> A2["A"]
    A2 --> A3["A"]
    A3 --> A4["B"]
    A4 --> A5["B"]
    A5 --> A6["B"]

ASUS TS100-E4/PI2 - Installing the CPU heatsink - 5

natural_image Close-up of hands installing or adjusting a computer motherboard with visible wiring and components (no text or symbols)
  1. Connect the CPU fan cable to the connectors on the motherboard labeled CPU_FAN1.

ASUS TS100-E4/PI2 - Installing the CPU heatsink - 6

text_image PSM2-MC-T5100-E4 CPU_FAN1 FAN_PWM FANPWR2 GND

P5M2-M/C_TS100-E4 CPU Fan connector

ASUS TS100-E4/PI2 - Installing the CPU heatsink - 7

Do not forget to connect the CPU fan connector to CPU_FAN1! Hardware monitoring errors can occur if you fail to plug this connector.

2.4 System memory

2.4.1 Overview

The motherboard comes with four Double Data Rate 2 (DDR2) Dual Inline Memory Modules (DIMM) sockets.

A DDR2 module has the same physical dimensions as a DDR DIMM but has a 240-pin footprint compared to the 184-pin DDR DIMM. DDR2 DIMMs are notched differently to prevent installation on a DDR DIMM socket.

The figure illustrates the location of the DDR2 DIMM sockets:

ASUS TS100-E4/PI2 - Overview - 1

text_image P5M2-MC_T8100-E4 PC24200 112 Pins128 Pins DIMM_A1 DIMM_A2 DIMM_B1 DIMM_B2

P5M2-M/C_TS100-E4 240-pin DDR2 DIMM Sockets

2.4.2 Memory configurations

You may install 512 MB, 1 GB, and 2 GB unbuffered ECC or non-ECC DDR2-533/667 DIMMs into the DIMM sockets.

ASUS TS100-E4/PI2 - Memory configurations - 1

  • Always install DIMMs with the same CAS latency. For optimum compatibility, we recommend that you obtain memory modules from the same vendor. Refer to the DDR2 Qualified Vendors List on the ASUS web site.
  • When installing one or two DIMMs, install the DIMM(s) to the blue slots (DIMM_A1/DIMM_B1).
  • Three DDR2 DIMMs intalled into any three memory sockets will function in single-channel mode.

2.4.3 Installing a DIMM

ASUS TS100-E4/PI2 - Installing a DIMM - 1

Unplug the power supply before adding or removing DIMMs or other system components. Failure to do so can cause severe damage to both the motherboard and the components.

To install a DIMM:

  1. Unlock a DIMM socket by pressing the retaining clips outward.
  2. Align a DIMM on the socket such that the notch on the DIMM matches the break on the socket.
  3. Firmly insert the DIMM into the socket until the retaining clips snap back in place and the DIMM is properly seated.

ASUS TS100-E4/PI2 - To install a DIMM: - 1

ASUS TS100-E4/PI2 - To install a DIMM: - 2

text_image t by 3 DDR2 DIMM notch 2 1

Unlocked retaining clip

  • A DDR2 DIMM is keyed with a notch so that it fits in only one direction. DO NOT force a DIMM into a socket to avoid damaging the DIMM.
  • The DDR2 DIMM sockets do not support DDR DIMMs. DO NOT install DDR DIMMs to the DDR2 DIMM sockets.

2.4.4 Removing a DIMM

Follow these steps to remove a DIMM.

  1. Simultaneously press the retaining clips outward to unlock the DIMM.

ASUS TS100-E4/PI2 - Removing a DIMM - 1

Support the DIMM lightly with your fingers when pressing the retaining clips. The DIMM might get damaged when it flips out with extra force.

ASUS TS100-E4/PI2 - Removing a DIMM - 2

text_image with the ght out 1 DDR2 DIMM notch 1 2
  1. Remove the DIMM from the socket.

2.5 Installing a hard disk drive

The server system supports one Serial ATA hard disk drive through a detachable hard disk drive cage.

ASUS TS100-E4/PI2 - Installing a hard disk drive - 1

You may purchase a second hard disk drive cage to install an additional HDD. Refer to the next chapter for details.

Hard disk drive cage

ASUS TS100-E4/PI2 - Installing a hard disk drive - 2

natural_image Interior view of an electronic device showing internal components and wiring (no readable text or symbols)

Hard disk drive installation

The detachable hard disk drive cage accommodates one Serial ATA hard disk drive.

To install the first Serial ATA hard disk drive:

ASUS TS100-E4/PI2 - Hard disk drive installation - 1

Configure your hard disk drive as Master/Slave device before installing it to the drive cage. Refer to the HDD documentation on how to set the drive as a Master/Slave device.

  1. First remove side cover.
  2. Then, press the HDD cage lock while pulling the cage out from the chassis. Place the HDD cage in a flat surface.

ASUS TS100-E4/PI2 - Hard disk drive installation - 2

natural_image Close-up of a hand inserting a component into a device casing with visible circuitry and wiring (no text or symbols)
  1. Install the SATA HDD.

ASUS TS100-E4/PI2 - Hard disk drive installation - 3

natural_image Close-up of hands installing or adjusting a device into a computer motherboard with visible wiring and components (no text or symbols)
  1. Secure the SATA HDD with three screws as show.

ASUS TS100-E4/PI2 - Hard disk drive installation - 4

natural_image Interior view of an electronic device showing a circuit board with red circles highlighting specific components (no visible text or symbols)
  1. Connect the SATA signal and power cables.

ASUS TS100-E4/PI2 - Hard disk drive installation - 5

natural_image Close-up of electronic equipment with red and yellow wires connected to a black device (no visible text or symbols)

To install the second Serial ATA hard disk drive:

  1. Press the HDD cage lock while pulling the cage out from the chassis. Place the HDD cage in a flat surface.

ASUS TS100-E4/PI2 - Hard disk drive installation - 6

natural_image Close-up of a hand inserting a card into a computer tower case, showing internal components and no visible text or symbols.
  1. Insert an HDD to the upper bay of the cage. Make sure that the HDD screw holes are aligned with the HDD cage screw holes.

ASUS TS100-E4/PI2 - Hard disk drive installation - 7

text_image Screw holes

ASUS TS100-E4/PI2 - Hard disk drive installation - 8

DO NOT install a hard disk drive to the lower bay of the cage.

  1. Secure the HDD to the cage with two screws on both sides of the cage.

ASUS TS100-E4/PI2 - Hard disk drive installation - 9

natural_image 3D mechanical component with mounting holes and a green component, no visible text or symbols
  1. Reinstall the HDD cage to the chassis. Align the HDD cage and bay assembly rails, then carefully push the HDD cage until it is flushed to the chassis.

ASUS TS100-E4/PI2 - Hard disk drive installation - 10

natural_image Interior view of an electronic device showing a CD drive with a blue arrow pointing to a component (no text or symbols visible)
  1. Connect one end of the supplied 7-pin SATA cable to the SATA connector at the back of the drive.

  2. Connect the other end to a SATA connector on the motherboard. See page 3-6 for the location of the SATA connectors.

ASUS TS100-E4/PI2 - Hard disk drive installation - 11

text_image Internal view of a computer motherboard with numbered components and wiring, highlighting a red cable connection.
  1. Connect a 4-pin power plug from the power supply unit to the power connector at the back of the drive.

ASUS TS100-E4/PI2 - Hard disk drive installation - 12

natural_image Interior view of a computer motherboard showing CPU socket, RAM slots, and wiring (no visible text or labels)

OR

Connect the 15-pin Serial ATA power plug to the Serial ATA power connector at the back of the drive.

ASUS TS100-E4/PI2 - Hard disk drive installation - 13

natural_image Close-up of electronic components with red and yellow wires, no visible text or symbols
  1. The first and second SATA HDD install finished as show.

ASUS TS100-E4/PI2 - Hard disk drive installation - 14

natural_image Close-up of an electronic device with visible circuit board, cables, and connectors (no readable text or symbols)

ASUS TS100-E4/PI2 - Hard disk drive installation - 15

Use either the SATA power connector OR the legacy 4-pin power connector. DO NOT use both to prevent damage to components and to keep the system from becoming unstable.

2.6 Installing 5.25-inch drives

ASUS TS100-E4/PI2 - Installing 5.25-inch drives - 1

Make sure to unplug the power cable before installing or removing any system components. Failure to do so may cause severe damage to the motherboard and other system components!

The system comes with four 5.25-inch drive bays located on the upper front part of the chassis. An optical drive that comes standard/optional with the system package occupies the uppermost bay (labeled 1). The lower bays (labeled 2, 3, and 4) are available for additional 5.25-inch optical, zip, or floppy disk drives.

ASUS TS100-E4/PI2 - Installing 5.25-inch drives - 2

You must remove the front panel cover before installing a 5.25-inch drive(s).

ASUS TS100-E4/PI2 - Installing 5.25-inch drives - 3

text_image Internal panel of an electrical enclosure with numbered components and wiring, highlighting safety warnings.

2.6.1 Removing the front panel cover

To remove the front panel cover:

ASUS TS100-E4/PI2 - Removing the front panel cover - 1

natural_image Computer tower internal view showing a hand inserting a component into the tower (no text or symbols visible)
  1. Locate and remove two screws that secure the left side cover to the chassis. Keep the screw for later use.

ASUS TS100-E4/PI2 - Removing the front panel cover - 2

natural_image Hand pressing down on a black rectangular object with a blue arrow indicating motion (no text or symbols)
  1. Slightly pull the cover toward the direction of the rear panel until it disengages from the chassis. Set the cover aside.

  2. Press the front panel cover hook inward until it detaches from the chassis hole.

ASUS TS100-E4/PI2 - Removing the front panel cover - 3

text_image Instructional image showing a hand inserting a device into a panel, with magnified detail and numbered annotation (3)
  1. On the other side of th

system, locate three front panel cover hooks. Press the hooks inward until the front panel cover detaches from the chassis.

ASUS TS100-E4/PI2 - Removing the front panel cover - 4

natural_image Close-up of a computer tower internal panel with a hand inserting a component, showing no text or symbols.
  1. Carefully remove the front panel cover, then set aside.

ASUS TS100-E4/PI2 - Removing the front panel cover - 5

natural_image Close-up of hands installing a computer tower panel with blue arrows indicating direction (no text or symbols visible)

2.6.2 Installing additional optical drive(s)

ASUS TS100-E4/PI2 - Installing additional optical drive(s) - 1

Configure your optical drive as Master/Slave device before installing it to the drive bay. Refer to the optical drive documentation for details.

To install an additional optical drive(s):

ASUS TS100-E4/PI2 - Installing additional optical drive(s) - 2

natural_image Close-up of hands installing or adjusting a computer tower case with blue arrows pointing to components (no visible text or symbols)
  1. Select the drive bay you intend to use. Push the knock down metal cover in and out of the chassis until it is removed.

ASUS TS100-E4/PI2 - Installing additional optical drive(s) - 3

natural_image Close-up of hands installing a CD drive into a server rack (no visible text or symbols)
  1. Carefully insert the drive to the bay, then push it inward until it is flushed to the chassis front panel.

ASUS TS100-E4/PI2 - Installing additional optical drive(s) - 4

text_image Screw holes 3
  1. Align the optical drive and bay screw holes.

ASUS TS100-E4/PI2 - Installing additional optical drive(s) - 5

natural_image Close-up of a computer tower internal panel with visible circuitry and wiring, being adjusted by a hand (no text or symbols)
  1. Secure the drive with two screws on both sides of the bay.

ASUS TS100-E4/PI2 - Installing additional optical drive(s) - 6

natural_image Close-up of a computer tower internal panel with visible CPU socket, drive bays, and a hand inserting a cable (no text or symbols)
  1. Connect a 40-pin IDE cable (from the first optical drive) to the IDE connector on the drive.

ASUS TS100-E4/PI2 - Installing additional optical drive(s) - 7

natural_image Close-up of hands installing cables into a computer case with visible wiring and components (no text or symbols)
  1. Connect a 4-pin power plug from the power supply unit to the drive power connector.

ASUS TS100-E4/PI2 - Installing additional optical drive(s) - 8

natural_image Close-up of a hand inserting into a black hard drive into a plastic case, showing internal components and blue arrows indicating movement (no text or symbols visible)
  1. Remove the front panel bay cover opposite the drive bay you used by pressing the hooks inward.

Follow the same procedures when installing additional optical drives.

ASUS TS100-E4/PI2 - Installing additional optical drive(s) - 9

natural_image Interior view of a desktop computer tower showing internal components and a blue directional arrow (no readable text or symbols)
  1. Reinstall the front panel and side covers when done.

2.7 Installing expansion cards

The system comes with two PCI slots, one PCI Express x8 (x8 link) slot, and one PCI Express x1 (x4 link) slot.

ASUS TS100-E4/PI2 - Installing expansion cards - 1

Make sure to unplug the power supply before installing or removing an expansion card(s). Failure to do so may cause severe damage to both the motherboard and the components.

To install an expansion card:

  1. Before installing the expansion card, read the documentation that came with it and make the necessary hardware settings for the card.
  2. Lay the system on its side on a flat, stable surface.

  3. Release the screw as show.

ASUS TS100-E4/PI2 - Installing expansion cards - 2

natural_image Close-up of a server rack with a screwdriver inserted, showing a highlighted component (no visible text or symbols)
  1. Then remove the hook metal bracket under all slots of metal bracket.

  2. Then remove the metal bracket opposite the slot that you intend to use. Keep the metal bracket screw for later use.

ASUS TS100-E4/PI2 - Installing expansion cards - 3

natural_image Close-up of hands installing a component on a computer motherboard, with a blue indicator light visible (no text or symbols)
  1. Align the card connector with the slot, then press firmly until the card is completely seated on the slot.

ASUS TS100-E4/PI2 - Installing expansion cards - 4

natural_image Close-up of hands installing or adjusting a computer motherboard with visible CPU socket and circuit board (no text or symbols)
  1. Then ins tall the hook metal bracket under all slots of metal bracket.

ASUS TS100-E4/PI2 - Installing expansion cards - 5

natural_image Close-up of hands installing a green component on a computer motherboard with visible circuit boards and cables (no text or symbols)
  1. Finally, use the screwdriver secure the screw that you removed earlier.

ASUS TS100-E4/PI2 - Installing expansion cards - 6

natural_image Close-up of a computer motherboard with CPU socket and RAM slots, no visible text or symbols

2.8 Removing components

You may need to remove previously installed system components when installing or removing other system components, or when replacing a defective component. This section tells how to remove the following components:

  1. Floppy disk drive (FDD)
  2. System fan (Optional)

2.8.1 Removing the floppy disk drive

To remove the FDD:

  1. Disconnect the FDD power plug and signal cable.

ASUS TS100-E4/PI2 - Removing the floppy disk drive - 1

natural_image Close-up of a hand inserting a component into an electronic device casing, showing a blue arrow and green key (no text or symbols visible)
  1. Unlock the FDD bay by moving the drive bay lock toward the direction of the front panel.

  2. Carefully pull the FDD from the chassis. Set the FDD aside.

ASUS TS100-E4/PI2 - Removing the floppy disk drive - 2

natural_image Close-up of a mechanical assembly with a red circle highlighting a component, no visible text or symbols
  1. Use the screwdriver to release the screw.

ASUS TS100-E4/PI2 - Removing the floppy disk drive - 3

natural_image Close-up of a hand inserting a USB into an internal storage unit (no visible text or symbols)

To install a floppy disk drive:

  1. Insert the drive to the bay until it is flushed to the chassis front panel.

  2. Align the FDD screw hole with the drive bay lock pin.

ASUS TS100-E4/PI2 - Removing the floppy disk drive - 4

natural_image Close-up of a hand inserting a USB into a computer case (no visible text or symbols)
  1. Use the screwdriver secure the screw that you removed earlier.
  2. Move the drive bay lock toward the rear panel to secure the lock.
  3. Attach the FDD power and signal cables to the connectors at the back of the drive.

ASUS TS100-E4/PI2 - Removing the floppy disk drive - 5

natural_image Close-up of a computer case with a hand inserting a component, showing internal components and a blue arrow indicating direction (no text or symbols visible)

ASUS TS100-E4/PI2 - Removing the floppy disk drive - 6

natural_image Close-up of a mechanical component with a numbered callout (3) and a tool inserted, no visible text or symbols.

2.8.2 Removing/Add the chassis fan (Optional)

To remove the chassis fan:

  1. Disconnect the chassis fan cable from the REAR_FAN1 connector on the motherboard.
  2. Locate and remove four chassis fan screws at the rear panel. Keep the screws for later use.

ASUS TS100-E4/PI2 - Removing/Add the chassis fan (Optional) - 1

Hold the chassis fan with one hand while removing the chassis fan screws.

ASUS TS100-E4/PI2 - Removing/Add the chassis fan (Optional) - 2

natural_image Close-up of a server rack with grid and mounting holes, no visible text or symbols
  1. Remove the chassis fan, then set aside.

ASUS TS100-E4/PI2 - Removing/Add the chassis fan (Optional) - 3

The chassis fan is purchased separately.

ASUS TS100-E4/PI2 - Removing/Add the chassis fan (Optional) - 4

natural_image Close-up of a hand inserting a CD into a computer drive socket (no visible text or symbols)

2.9 Connecting cables

The TS100-E4/PI2 chassis includes the power and signal cables that you need to connect to the motherboard, storage drives, and other devices that you intend to install.

ASUS TS100-E4/PI2 - Connecting cables - 1

Most of the cables for the chassis kit are already connected upon shipment. When installing system devices and connecting cables, make sure that all cables are routed properly for better system stability and performance. Refer to the picture below when arranging cables.

ASUS TS100-E4/PI2 - Connecting cables - 2

text_image Internal view of a computer motherboard with numbered components, showing CPU socket, RAM slots, and drive bays.

Standard cables connected to the motherboard

  1. 4-pin ATX 12V power plug
  2. 24-pin ATX power plug
  3. Floppy disk drive ribbon cable
  4. Front panel USB 2.0 cable

  5. IDE signal cable

  6. Serial ATA signal cables
  7. System panel cable
  8. System fan cables

ASUS TS100-E4/PI2 - Standard cables connected to the motherboard - 1

See “Chapter 3: Motherboard information” for detailed information on motherboard connectors.

2.10 Replacing the side cover

After installing all components and re-connecting cables, replace the side cover by following these instructions.

  1. Match the side cover hooks to the chassis rail on the side of the chassis.

  2. Fit the side cover the cover toward the chassis until it fits.

ASUS TS100-E4/PI2 - Replacing the side cover - 1

text_image Diagram showing a hand inserting a device into a server tower, labeled with components 1 and 2, indicating a loading or disassembly process.
  1. Slide the cover toward the front until it snaps in place.

ASUS TS100-E4/PI2 - Replacing the side cover - 2

natural_image Hand interacting with a black server unit panel, showing a blue arrow indicating a process or movement (no text or symbols visible)

Chapter 3

This chapter gives information about the motherboard that comes with the server. This chapter includes the motherboard layout, jumper settings, and connector locations.

ASUS TS100-E4/PI2 - Chapter 3 - 1

natural_image Black desktop computer tower with visible drive bays and ventilation slots (no text or labels)

Mothereboar info

3.1 Motherboard overview P5M2-M/C\_TS100-E4

ASUS TS100-E4/PI2 - Motherboard overview P5M2-M/C\_TS100-E4 - 1

text_image 24.5cm (9.6in) PS/2K0MS T: Mouse B: Keyboard USB12 VGA1 COM PARALLEL PORT LAN1 ATXPWR1 KBPWR USBPW12 FM_CPU2 CPU_FAN2 PSUSMB1 SUPER I/O TPM1 BUZZ1 Intel MCH Mukilteo 2 CR2032 3 Lithium Cell CMOS Power P5M2-M/C_TS100-E4 CPU FAN1 FM CPU LGAT75 DDR2 DIMM_A1 (64 bit,240-pin module) DDR2 DIMM_A2 (64 bit,240-pin module) DDR2 DIMM_B1 (64 bit,240-pin module) DDR2 DIMM_B2 (64 bit,240-pin module) ICS 9541238BFLF ASUS PCIE1 SB_FWR1 PCIE2 COM2 RAID_SEL1 PCI3 PCI4 ASMB3 XGIZ7 VGA EN1 FRNT FAN2 VLA_EN1 RLOPPY1 USB34 USBPW34 SATA1 SATA2 SATA3 SATA4 8Mbit Flash BIOS RECOVERY FXI_FIND2 FXI_IDE1 FRNT FAN2 FRNEDI HOLDEN 24.5cm (9.6in)

Layout contents

Slots/Socket PagePage
1. CPU socket 2-5
2. DDR2 DIMM slots 2-9
3. PCI/PCI Express slots 2-18
JumpersPagePage
1. Clear RTC RAM (CLRTC1) 3-5
2. CPU fan pin selection (3-pin FM_CPU1, FM_CPU2)3-6
3. USB device wake-up (3-pin USBPW12, USBPW34)3-6
4. Keyboard/Mouse power (3-pin KBPWR1)3-7
5. VGA controller setting (3-pin VGA_EN1)3-7
6. Gigabit LAN controller setting (3-pin LAN_EN1)3-8
7. RAID controller selection (3-pin RAID_SEL1)3-8
8. Force BIOS recovery setting (3-pin RECOVERY1)3-9
Rear panel connectors: PagePage
1. PS/2 mouse port (green) 3-10
2. Parallel port3-10
3. Gigabit LAN1 (RJ-45) port 3-10
4. VGA port 3-10
5. Serial (COM1) port 3-10
6. USB 2.0 ports 1 and 2 3-10
7. PS/2 keyboard port (purple) 3-10
Internal connectors of PagePage
1. Floppy disk drive connector (34-1 pin FLOPPY1) 3-11
2. ICH7R primary IDE connectors (40-1 pin PRI_IDE1) 3-12
3. Serial ATA connectors (7-pin SATA1, SATA2, SATA3, SATA4) 3-13
4. Hard disk activity LED connector (4-pin HDLED1) 3-14
5. USB connector (10-1 pin USB34) 3-14
6. Serial port connector (10-1 pin COM2) 3-15
7. CPU and system fan connectors (3-pin CPU_FAN1/2) 3-15
8. Backplane SMBus connector (6-1 pin BPSMB1) 3-16
9. Power supply SMBus connector (5-pin PSUSMB1) 3-16
10. SSI power connectors (24-pin ATXPWR1, 8-pin ATX12V2) 3-17
11. Auxiliary panel connector (20-pin AUX_PANEL1) 3-18
12. System panel connector (20-pin PANEL1)3-19

3.2 Jumpers

1. Clear RTC RAM (CLRTC1)

This jumper allows you to clear the Real Time Clock (RTC) RAM in CMOS. You can clear the CMOS memory of date, time, and system setup parameters by erasing the CMOS RTC RAM data. The onboard button cell battery powers the RAM data in CMOS, which include system setup information such as system passwords.

To erase the RTC RAM:

  1. Turn OFF the computer and unplug the power cord.
  2. Remove the onboard battery.
  3. Move the jumper cap from pins 1-2 (default) to pins 2-3. Keep the cap on pins 2-3 for about 5\~10 seconds, then move the cap back to pins 1-2.
  4. Re-install the battery.
  5. Plug the power cord and turn ON the computer.
  6. Hold down the key during the boot process and enter BIOS setup to re-enter data.

ASUS TS100-E4/PI2 - To erase the RTC RAM: - 1

Except when clearing the RTC RAM, never remove the cap on CLRTC jumper default position. Removing the cap will cause system boot failure!

ASUS TS100-E4/PI2 - To erase the RTC RAM: - 2

text_image P5M2-MC_TS100-E4 CLRTC1 1 2 2 3 Normal (Default) Clear RTC

P5M2-M/C_TS100-E4 Clear RTC RAM

2. CPU fan pin selection (3-pin FM\_CPU1, FM\_CPU2)

These jumpers allow you to connect either a 3-pin or a 4-pin fan cable plug to the CPU fan connectors (CPU_FAN1, CPU_FAN2). Set these jumpers to pins 1-2 if you are using a 3-pin fan cable plug, or to pins 2-3 if you are using a 4-pin plug.

ASUS TS100-E4/PI2 - CPU fan pin selection (3-pin FM\_CPU1, FM\_CPU2) - 1

text_image P5M2-M/C_TS100-E4 FM CPU Setting FM_CPU1 1 2 2 3 3-pin fan 4-pin fan (Default) FM_CPU2 1 2 3 3-pin fan 4-pin fan (Default)

3. USB device wake-up (3-pin USBPW12, USBPW34)

Set these jumpers to +5V to wake up the computer from S1 sleep mode (CPU stopped, DRAM refreshed, system running in low power mode) using the connected USB devices. Set to +5VSB to wake up from S4 sleep mode (no power to CPU, DRAM in slow refresh, power supply in reduced power mode).

ASUS TS100-E4/PI2 - USB device wake-up (3-pin USBPW12, USBPW34) - 1

text_image P5M2-M/C_TS100-E4 USB Device Wake-Up USBPW12 +5V +5VSB (Default) 2 31 2 USBPW34 +5V +5VSB (Default) 2 31 2

ASUS TS100-E4/PI2 - USB device wake-up (3-pin USBPW12, USBPW34) - 2

  • The USB device wake-up feature requires a power supply that can provide 500mA on the +5VSB lead for each USB port; otherwise, the system would not power up.
  • If you are using Windows 2000, you need to install Service Pack 4 to wake up the system from S4 sleep mode.
  • The total current consumed must NOT exceed the power supply capability (+5VSB) whether under normal condition or in sleep mode.

4. Keyboard/Mouse power (3-pin KBPWR1)

This jumper allows you to enable or disable the keyboard/mouse wake-up feature. Set this jumper to pins 2-3 (+5VSB) to wake up the computer when you press a key on the keyboard (the default is the Space Bar) or use the mouse. This feature requires an ATX power supply that can supply at least 1A on the +5VSB lead, and a corresponding setting in the BIOS.

ASUS TS100-E4/PI2 - Keyboard/Mouse power (3-pin KBPWR1) - 1

text_image KBPWR1 +5V +5VSB (Default) 2 31

P5M2-M/C_TS100-E4 Keyboard Power Setting

5. VGA controller setting (3-pin VGA\_EN1)

These jumpers allow you to enable or disable the onboard XGI Volari Z7® PCI VGA controller. Set to pins 1-2 to activate the VGA feature.

ASUS TS100-E4/PI2 - VGA controller setting (3-pin VGA\_EN1) - 1

text_image P5M2-M/C_TS100-E4 VGA_EN1 1 2 Enable (Default) 2 3 Disable P5M2-M/C_TS100-E4 VGA Setting
  1. Gigabit LAN controller setting [3-pin LAN_EN1)

These jumpers allow you to enable or disable the onboard Broadcom® BCM5721 Gigabit LAN1 controller. Set to pins 1-2 to activate the Gigabit LAN controller.

ASUS TS100-E4/PI2 - VGA controller setting (3-pin VGA\_EN1) - 2

text_image P5M2-M/C_TS100-E4 LAN_EN1 Setting LAN_EN1 1 2 Enable (Default) 2 3 Disable
  1. RAID controller selection (3-pin RAID_SEL1)

This jumper allows you to select the RAID configuration utility to use when you create disk arrays. Place the jumper caps over pins 1-2 if you want to use the LSI Logic Embedded SATA RAID Setup Utility (default); otherwise, place the jumper caps to pins 2-3 to use the Intel® Matrix Storage Manager.

ASUS TS100-E4/PI2 - VGA controller setting (3-pin VGA\_EN1) - 3

text_image P5M2-M/C_TS100-E4 RAID_SEL1 Setting RAID_SEL1 1 2 LSI RAID ROM (Default) 2 3 INTEL RAID ROM
  1. Force BIOS recovery setting (3-pin RECOVERY1)

This jumper allows you to quickly update or recover the BIOS when it gets corrupted.

To update the BIOS:

  1. Prepare a floppy disk that contains the latest BIOS for the mother board (xxxx-xxx.ROM) and the AFUDOS.EXE utility.
  2. Set the jumper to pins 2-3.
  3. Insert the floppy disk then turn on the system to update the BIOS.
  4. Shut down the system.
  5. Set the jumper back to pins 1-2.
  6. Turn on the system.

ASUS TS100-E4/PI2 - VGA controller setting (3-pin VGA\_EN1) - 4

text_image P5M2-MC TS100-E4 ASIM

RECOVERY1
ASUS TS100-E4/PI2 - VGA controller setting (3-pin VGA\_EN1) - 5

ASUS TS100-E4/PI2 - VGA controller setting (3-pin VGA\_EN1) - 6

1 2

2 3

Normal BIOS recovery (Default)

P5M2-M/C_TS100-E4 BIOS Recovery Setting

3.3 Connectors

3.3.1 Rear panel connectors

ASUS TS100-E4/PI2 - Rear panel connectors - 1

text_image 1 2

56 4 37

  1. PS/2 mouse port (green). This port is for a PS/2 mouse.
  2. Parallel port. This 25-pin port connects a parallel printer, a scanner, or other devices.
  3. Gigabit LAN1 (RJ-45) port. This ports allow Gigabit connection to a Local Area Network (LAN) through a network hub. Refer to the table below for the LAN port LED indications.
  4. VGA port. This port is for a VGA monitor or other VGA-compatible devices.
  5. Serial (COM1) port. This 9-pin communication port is for pointing devices or other serial devices.
  6. USB 2.0 ports 1 and 2. These two 4-pin Universal Serial Bus (USB) ports are available for connecting USB 2.0 devices.
  7. PS/2 keyboard port (purple). This port is for a PS/2 keyboard.

LAN port LED indications

ACT/LINKLED SPEED LEDSPEED LED
Status Description StatusDescriptionDescription
OFF No link OFF 10 Mbpsconnection
GREEN Linked ORANGE100 Mbps connection
BLINKING Data activityGREEN 1 Gbps connection

ASUS TS100-E4/PI2 - Rear panel connectors - 2

text_image ACT/LINK LED SPEED LED LAN port

3.3.2 Internal connectors

1. Floppy disk drive connector (34-1 pin FLOPPY1)

This connector is for the provided Floppy Disk Drive (FDD) signal cable. Insert one end of the cable to this connector, then connect the other end to the signal connector at the back of the floppy disk drive.

ASUS TS100-E4/PI2 - Floppy disk drive connector (34-1 pin FLOPPY1) - 1

Pin 5 on the connector is removed to prevent incorrect cable connection when using a FDD cable with a covered Pin 5.

ASUS TS100-E4/PI2 - Floppy disk drive connector (34-1 pin FLOPPY1) - 2

text_image P5M2.MC-TS100-E1 P5M4

ASUS TS100-E4/PI2 - Floppy disk drive connector (34-1 pin FLOPPY1) - 3

text_image FLOPPY1 PIN 1 NOTE: Orient the red markings on the floppy ribbon cable to PIN 1.

P5M2-M/C_TS100-E4 Floppy Disk Drive Connector

2. ICH7R primary IDE connector (40-1 pin PRI\_IDE1)

This connector is for an Ultra DMA 100/66 signal cable. The Ultra DMA 100/66 signal cable has three connectors: a blue connector for the primary IDE connector on the motherboard, a black connector for an Ultra DMA 100/66 IDE slave device (optical drive/hard disk drive), and a gray connector for an Ultra DMA 100/66 IDE master device (hard disk drive). If you install two hard disk drives, you must configure the second drive as a slave device by setting its jumper accordingly. Refer to the hard disk documentation for the jumper settings.

ASUS TS100-E4/PI2 - ICH7R primary IDE connector (40-1 pin PRI\_IDE1) - 1

  • Pin 20 on the IDE connector is removed to match the covered hole on the Ultra DMA cable connector. This prevents incorrect insertion when you connect the IDE cable.
  • Use the 80-conductor IDE cable for Ultra DMA 100/66 IDE devices.

ASUS TS100-E4/PI2 - ICH7R primary IDE connector (40-1 pin PRI\_IDE1) - 2

text_image P5M2-M/C_TS100-E4 IDE Connector PRI_IDE1 PIN 1 NOTE: Orient the red markings (usually zigzag) on the IDE ribbon cable to PIN 1.

3. Serial ATA connectors (7-pin SATA1, SATA2, SATA3, SATA4)

These connectors are for the Serial ATA signal cables for Serial ATA hard disk drives.

If you installed Serial ATA hard disk drives, you can create a RAID 0 and RAID 1 configuration using the Intel® Matrix Storage Technology or the LSI MegaRAID® utility embedded in the Intel® ICH7R Southbridge.

ASUS TS100-E4/PI2 - Serial ATA connectors (7-pin SATA1, SATA2, SATA3, SATA4) - 1

These connectors are setIDE mode by default. InIDE mode, you can connect Serial ATA boot/data hard disk drives to these connectors. If you intend to create a Serial ATA RAID set using these connectors, set the Configure SATA as item in the BIOS to [RAID]. See section "4.3.4 IDE Configuration" for details.

ASUS TS100-E4/PI2 - Serial ATA connectors (7-pin SATA1, SATA2, SATA3, SATA4) - 2

text_image P5M2-M/C_TS100-E4 SATA Connectors SATA1 SATA2 SATA3 SATA4

ASUS TS100-E4/PI2 - Serial ATA connectors (7-pin SATA1, SATA2, SATA3, SATA4) - 3

Important notes on Serial ATA

  • Use only two Serial ATA RAID connectors for each RAID 0 or RAID 1 set.
  • When using the connectors in IDE mode, connect the primary (boot) hard disk drive to the SATA1 or SATA2 connector. Refer to the table below for the recommended SATA hard disk drive connections.

Serial ATA hard disk drive connection

Connector Setting Use SettingUse
SATASATA2A MasterBoot diskerBoot disk
SATASATA2A Save Data disk haveHaveData disk
  1. Hard disk activity LED connector (4-pin HDLED1)

This connector supplies power to the hard disk activity LED. The read or write activities of any device connected to the SCSI connectors or the SATA connectors cause this LED to light up.

ASUS TS100-E4/PI2 - Important notes on Serial ATA - 1

text_image P5M2-M/C_TS100-E4 SCSI/SATA Card Activity LED Connecto HDLED1 NC ADD_IN_CARD_ACT# ADD_IN_CARD_ACT# NC P5M2-M/C_TS100-E4
  1. USB connector (10-1 pin USB34)

This connector is for USB 2.0 ports. This USB connector complies with USB 2.0 specification that supports up to 480 Mbps connection speed.

ASUS TS100-E4/PI2 - Important notes on Serial ATA - 2

text_image P5M2-M/C_TS100-E4 USB 2.0 Connector USB34 USB+5V USB P4- USB P4+ GND NC USB+5V USB P3- USB P3+ GND

6. Serial port connector (10-1 pin COM2)

This connector is for a serial (COM) port. Connect the serial port module cable to this connector, then install the module to a slot opening at the back of the system chassis. The serial port module is purchased separately.

ASUS TS100-E4/PI2 - Serial port connector (10-1 pin COM2) - 1

text_image P5M2-M/C TS100-E4 COM2 PIN 1

P5M2-M/C_TS100-E4 Serial Port2 (COM2) Connector

7. CPU and system fan connectors (3-pin CPU\_FAN1, CPU\_FAN2)

The fan connectors support cooling fans of 350 mA \~ 740 mA (8.88 W max.) or a total of 2.1 A \~ 4.44 A (53.28 W max.) at +12V. Connect the fan cables to the fan connectors on the motherboard, making sure that the black wire of each cable matches the ground pin of the connector.

ASUS TS100-E4/PI2 - CPU and system fan connectors (3-pin CPU\_FAN1, CPU\_FAN2) - 1

Do not forget to connect the fan cables to the fan connectors. Insufficient air flow inside the system may damage the motherboard components. These are not jumpers! Do not place jumper caps on the fan connectors!

ASUS TS100-E4/PI2 - CPU and system fan connectors (3-pin CPU\_FAN1, CPU\_FAN2) - 2

text_image CPU_FAN1 FAN_PWM FANPWR2 GND CPU_FAN2 GND FANPWR2 FAN_PWM

P5M2-M/C_TS100-E4 CPU Fan connectors

  1. Backplane SMBus connector (6-1 pin BPSMB1)

This connector allows you to connect SMBus (System Management Bus) devices. Devices communicate with an SMBus host and/or other SMBus devices using the SMBus interface.

ASUS TS100-E4/PI2 - CPU and system fan connectors (3-pin CPU\_FAN1, CPU\_FAN2) - 3

text_image P5M2-M/C_TS100-E4 SMBus Connector BPSMB1 1 FAN_DC1 I2C_CLK GND I2C_DATA +5V
  1. Power supply SMBus connector (5-pin PSUSMB1)

This connector is for the power supply SMB cable, if your power supply supports the SMBus function.

ASUS TS100-E4/PI2 - CPU and system fan connectors (3-pin CPU\_FAN1, CPU\_FAN2) - 4

text_image PSUSMB1 P5M2-M/C_TS100-E4 Power Supply SMBus Connector +3.3V Remote Sense GND NC PSU_I2CDATA PSU_I2CCLK

10. Power connectors (24-pin ATXPWR1, 4-pin ATX12V2)

These connectors are for power supply plugs. The power supply plugs are designed to fit these connectors in only one orientation. Find the proper orientation and push down firmly until the connectors completely fit.

ASUS TS100-E4/PI2 - Power connectors (24-pin ATXPWR1, 4-pin ATX12V2) - 1

  • Use of an 12 V Specification 2.0-compliant power supply unit (PSU) that provides a minimum power of 250 W is recommended for a fully-configured system.
  • Do not forget to connect the 4-pin ATX +12 V power plug; other - wise, the system will not boot up.
  • We recommend that you use a PSU with a higher power output when configuring a system with more power consuming devices. The system may become unstable or may not boot up if the power is inadequate.
  • You must install a PSU with a higher power rating if you intend to install additional devices.

ASUS TS100-E4/PI2 - Power connectors (24-pin ATXPWR1, 4-pin ATX12V2) - 2

text_image ATXPWR1 24-pin Power Connector P5M2-M/C_TS100-E4 ATX Power Connectors +3 Volts -12 Volts Ground PSON# Ground Ground Ground -5 Volts +5 Volts +5 Volts +5 Volts Ground Power OK +5V Standby +12 Volts +12 Volts +3 Volts ATX12V1 +12V DC GND +12V DC GND

11. Auxiliary panel connector (20-pin AUX\_PANEL1)

This connector is for additional front panel features including front panel SMB, locator LED and switch, chassis intrusion, and LAN LEDs.

  • Front panel SMB (6-1 pin FPSMB) These leads connect the front panel SMBus cable.
    • LAN activity LED (2-pin LAN1_LED, LAN2_LED)
    These leads are for Gigabit LAN activity LEDs on the front panel.
  • Chassis intrusion (2-pin CHASSIS)

These leads are for the intrusion detection feature for chassis with intrusion sensor or microswitch. When you remove any chassis component, the sensor triggers and sends a high-level signal to these leads to record a chassis intrusion event.

- Locator LED (6-pin LOCATOR)

These leads are for the locator switch and LED on the front panel.

ASUS TS100-E4/PI2 - Auxiliary panel connector (20-pin AUX\_PANEL1) - 1

text_image P5M2-MC-TS100-E4 ASOS

AUX_PANEL1
ASUS TS100-E4/PI2 - Auxiliary panel connector (20-pin AUX\_PANEL1) - 2

text_image PIN1 +5VSB NC I2C_4_CLK# CASEOPEN GNDGND I2C_4_DATA#LOCAT# +5VSBLOCATORLED LAN1_LINKACTLED+ LAN1_LINKACTLED- LAN2_LINKACTLED-L LAN2_LINKACTLED+

P5M2-M/C_TS100-E4 Auxiliary Panel Connector

12. System panel connector (20-pin PANEL1)

This connector supports several chassis-mounted functions.

• System power LED (Green 3-pin PLED)

This 3-pin connector is for the system power LED. Connect the chassis power LED cable to this connector. The system power LED lights up when you turn on the system power, and blinks when the system is in sleep mode.

- Message LED (Brown 2-pin MLED)

This connector is for the message LED cable that connects to the front message LED. The message LED indicates the booting status. The LED blinks when the system is in the boot process until the operating system is loaded.

- Hard disk drive activity LED (Red 2-pin IDE\_LED)

This 2-pin connector is for the HDD Activity LED. Connect the HDD Activity LED cable to this connector. The IDE LED lights up or flashes when data is read from or written to the HDD.

• System warning speaker (Orange 4-pin SPEAKER)

This 4-pin connector is for the chassis-mounted system warning speaker. The speaker allows you to hear system beeps and warnings.

- ATX power button/soft-off button (Light Green 2-pin PWRSW)

This connector is for the system power button. Pressing the power button turns the system on or puts the system in sleep or soft-off mode depending on the BIOS settings. Pressing the power switch for more than four seconds while the system is ON turns the system OFF.

- Reset button (Blue 2-pin RESET)

This 2-pin connector is for the chassis-mounted reset button for system reboot without turning off the system power.

ASUS TS100-E4/PI2 - - Reset button (Blue 2-pin RESET) - 1

text_image P5M2-M/C_TS 100-E4 ASUS PANEL1 POWERLED+HDLEI NCHDLED- POWERLED- MLED+NMIBTN# MLED-GND NCPOWERBTN# +5V GND GNDNC GNDRESETBN# SPKROUTGND

P5M2-M/C_TS100-E4 System Panel Connector

ASUS TS100-E4/PI2 - - Reset button (Blue 2-pin RESET) - 2

The system panel connector is color-coded for easy connection.

Chapter 4

This chapter tells how to change the system settings through the BIOS Setup menus. Detailed descriptions of the BIOS parameters are also provided.

ASUS TS100-E4/PI2 - Chapter 4 - 1

natural_image Black desktop computer tower with visible drive bays and ventilation slots (no text or labels)

BIOS SETUP

4.1 Managing and updating your BIOS

The following utilities allow you to manage and update the motherboard Basic Input/Output System (BIOS) setup.

  1. ASUS AFUDOS (Updates the BIOS in DOS mode using a bootable floppy disk.)
  2. ASUS CrashFree BIOS 2 (Updates the BIOS using a bootable floppy disk or the motherboard support CD when the BIOS file fails or gets corrupted.)
  3. ASUS Update (Updates the BIOS in Windows® environment.)

Refer to the corresponding sections for details on these utilities.

ASUS TS100-E4/PI2 - Managing and updating your BIOS - 1

Save a copy of the original motherboard BIOS file to a bootable floppy disk in case you need to restore the BIOS in the future. Copy the original motherboard BIOS using the ASUS Update or AFUDOS utilities.

4.1.1 Creating a bootable floppy disk

To create a bootable floppy disk in a DOS environment:

a. Insert a 1.44MB floppy disk into the drive.
b. At the DOS prompt, type format A:/S then press .

4.1.2 AFUDOS utility

The AFUDOS utility allows you to update the BIOS file in DOS environment using a bootable floppy disk with the updated BIOS file. This utility also allows you to copy the current BIOS file that you can use as backup when the BIOS fails or gets corrupted during the updating process.

Copying the current BIOS

To copy the current BIOS file using the AFUDOS utility:

ASUS TS100-E4/PI2 - Copying the current BIOS - 1

  • Make sure that the floppy disk is not write-protected and has at least 1024 KB free space to save the file.
  • The succeeding BIOS screens are for reference only. The actual BIOS screen displays may not be same as shown.

  • Copy the AFUDOS utility (afudos.exe) from the motherboard support CD to the bootable floppy disk you created earlier.

  • Boot the system in DOS mode, then at the prompt type:

afudos /o [filename]

where the [filename] is any user-assigned filename not more than eight alphanumeric characters for the main filename and three alphanumeric characters for the extension name.

ASUS TS100-E4/PI2 - Copying the current BIOS - 2

text_image A:\>afudos /oOLDBIOS1.rom Main filename Extension name
  1. Press . The utility copies the current BIOS file to the floppy disk.
A:\>afudos /oOLDBIOS1.rom
AMI Firmware Update Utility - Version 1.19(ASUS V2.07(03.11.24BB))
Copyright (C) 2002 American Megatrends, Inc. All rights reserved.
Reading flash .... done
Write to file..... ok
A:\> 

The utility returns to the DOS prompt after copying the current BIOS file.

Updating the BIOS file

To update the BIOS file using the AFUDOS utility:

  1. Visit the ASUS website (www.asus.com) and download the latest BIOS file for the motherboard. Save the BIOS file to a bootable floppy disk.

ASUS TS100-E4/PI2 - Updating the BIOS file - 1

Write the BIOS filename on a piece of paper. You need to type the exact BIOS filename at the DOS prompt.

  1. Copy the AFUDOS utility (afudos.exe) from the motherboard support CD to the bootable floppy disk you created earlier.
  2. Boot the system in DOS mode, then at the prompt type:

afudos /i [filename]

where [filename] is the latest or the original BIOS file on the bootable floppy disk.

A:\>afudos /iTS100-E4.ROM 
  1. The utility verifies the file and starts updating the BIOS.
A:\>afudos /iTS100-E4.ROM
AMI Firmware Update Utility - Version 1.19(ASUS V2.07(03.11.24BB))
Copyright (C) 2002 American Megatrends, Inc. All rights reserved.

WARNING!! Do not turn off power during flash BIOS
Reading file ....... done
Reading flash ....... done

Advance Check ......
Erasing flash ....... done
Writing flash ....... 0x0008CC00 (9%) 

ASUS TS100-E4/PI2 - Updating the BIOS file - 2

Do not shut down or reset the system while updating the BIOS to prevent system boot failure!

  1. The utility returns to the DOS prompt after the BIOS update process is completed. Reboot the system from the hard disk drive.
A:\>afudos /iTS100-E4.ROM
AMI Firmware Update Utility - Version 1.19(ASUS V2.07(03.11.24BB))
Copyright (C) 2002 American Megatrends, Inc. All rights reserved.

WARNING!! Do not turn off power during flash BIOS
Reading file ....... done
Reading flash ....... done

Advance Check ......
Erasing flash ....... done
Writing flash ....... done
Verifying flash ....... done

Please restart your computer

A:\> 

Updating the BIOS file using a USB flash drive

If you have not purchased a USB floppy disk drive, you may update the BIOS file using a USB flash drive. Format the USB flash drive to FAT16 or 32 system file before updating the BIOS.

To format the USB flash drive to a FAT32/16 system file:

  1. Insert the USB flash drive to an available USB port.
  2. From the Windows desktop, click Start, then select My computer.
  3. Right-click the USB flash drive icon, then select Format from the menu.
  4. From the File system field, select FAT32 or FAT16, then click the Start button.

To update the BIOS file:

  1. Copy the original or the latest BIOS file and the AFUDOS utility (afudos.exe) to the USB flash drive.
  2. Insert the USB flash drive to an available USB port, then place the motherboard support CD to the optical drive.
  3. Boot the system from the support CD, then select the FreeDOS command prompt.
  4. At the DOS prompt, replace the prompt with the USB flash disk drive letter, then type: afudos /i [filename]
  5. Follow the instructions in the previous section to update the BIOS file.

4.1.3 ASUS CrashFree BIOS 2 utility

The ASUS CrashFree BIOS 2 is an auto recovery tool that allows you to restore the BIOS file when it fails or gets corrupted during the updating process. You can update a corrupted BIOS file using the motherboard support CD or the floppy disk that contains the updated BIOS file.

ASUS TS100-E4/PI2 - ASUS CrashFree BIOS 2 utility - 1

  • Prepare the motherboard support CD or the floppy disk containing the updated motherboard BIOS before using this utility.
  • Make sure that you rename the original or updated BIOS file in the floppy disk to TS100-E4.ROM.

Recovering the BIOS from a floppy disk

To recover the BIOS from a floppy disk:

  1. Turn on the system.
  2. Insert the floppy disk with the original or updated BIOS file to the floppy disk drive.
  3. The utility displays the following message and automatically checks the floppy disk for the original or updated BIOS file.
Bad BIOS checksum. Starting BIOS recovery...
Checking for floppy... 

When found, the utility reads the BIOS file and starts flashing the corrupted BIOS file.

Bad BIOS checksum. Starting BIOS recovery...
Checking for floppy...
Floppy found!
Reading file "TS100-E4.ROM". Completed.
Start flashing... 

ASUS TS100-E4/PI2 - Recovering the BIOS from a floppy disk - 1

DO NOT shut down or reset the system while updating the BIOS! Doing so can cause system boot failure!

  1. Restart the system after the utility completes the updating process.

Recovering the BIOS from the support CD

To recover the BIOS from the support CD:

  1. Remove any floppy disk from the floppy disk drive, then turn on the system.
  2. Insert the support CD to the optical drive.
  3. The utility displays the following message and automatically checks the floppy disk for the original or updated BIOS file.
Bad BIOS checksum. Starting BIOS recovery...
Checking for floppy... 

When no floppy disk is found, the utility automatically checks the optical drive for the original or updated BIOS file. The utility then updates the corrupted BIOS file.

Bad BIOS checksum. Starting BIOS recovery...
Checking for floppy...
Floppy not found!
Checking for CD-ROM...
CD-ROM found!
Reading file "TS100-E4.ROM". Completed.
Start flashing... 

ASUS TS100-E4/PI2 - Recovering the BIOS from the support CD - 1

DO NOT shut down or reset the system while updating the BIOS! Doing so can cause system boot failure!

  1. Restart the system after the utility completes the updating process.

ASUS TS100-E4/PI2 - Recovering the BIOS from the support CD - 2

The recovered BIOS may not be the latest BIOS version for this motherboard. Visit the ASUS website (www.asus.com) to download the latest BIOS file.

4.1.4 ASUS Update utility

The ASUS Update is a utility that allows you to manage, save, and update the motherboard BIOS in Windows® environment. The ASUS Update utility allows you to:

  • Save the current BIOS file
    • Download the latest BIOS file from the Internet
  • Update the BIOS from an updated BIOS file
  • Update the BIOS directly from the Internet, and
    • View the BIOS version information.

This utility is available in the support CD that comes with the motherboard package.

ASUS TS100-E4/PI2 - ASUS Update utility - 1

ASUS Update requires an Internet connection either through a network or an Internet Service Provider (ISP).

Installing ASUS Update

To install ASUS Update:

  1. Place the support CD in the optical drive. The Drivers menu appears.
  2. Click the Utilities tab, then click Install ASUS Update VX.XX.XX.
  3. The ASUS Update utility is copied to your system.

ASUS TS100-E4/PI2 - Installing ASUS Update - 1

Quit all Microsoft® Windows® applications before you update the BIOS using this utility.

Updating the BIOS through the Internet

To update the BIOS through the Internet:

  1. Launch the ASUS Update utility from the Windows® desktop by clicking Start > Programs > ASUS > ASUSUpdate > ASUSUpdate. The ASUS Update main window appears.

ASUS TS100-E4/PI2 - Updating the BIOS through the Internet - 1

text_image Internet Internet Explorer E-mail OutlookExpress Paint Windows Media Play ASUSUpdate AI Booster v2.00.18 Voice Editor MSN Explorer All Programs Windows Catalog Windows Update Accessories ASUS ASUS Utility Games Marvel Startup Voice Editor Internet Explorer MSN Explorer Outlook Express Remote Assistance Windows MediaPlayer Windows Messenger Log Off Shut Down Documents AI Booster AsusUpdate ASUSUpdate MyLogo Uninstall ASUSUpdate start Select
  1. Select Update BIOS from the Internet option from the drop-down menu, then click Next.

  2. Select the ASUS FTP site nearest you to avoid network traffic, or click Auto Select. Click Next.

ASUS TS100-E4/PI2 - Updating the BIOS through the Internet - 2

text_image Select the Update Method 1. Update/Save BIOS from/to a file. 2. Update BIOS from the Internet - Update system BIOS using a specified BIOS image file on ASUS Web Site. 3. Download BIOS from the Internet - Download a specified BIOS image file via Internet for later usage. 4. Check BIOS Information Update BIOS from the Internet Save current BIOS to a file Update BIOS from a file Update BIOS from the Internet Download BIOS from the Internet Check BIOS Information Options

ASUS TS100-E4/PI2 - Updating the BIOS through the Internet - 3

text_image Select the Update Server Before Continue, please make sure that your system is connected to the Internet. You can then choose a web site by yourself or click. AutoSelect button, ASUS Update will choose the best site based on network traffic automatically for you. Passive Proxy Setting Auto Select Rp.asus.com.lw Back Cancel Next
  1. From the FTP site, select the BIOS version that you wish to download. Click Next.
  2. Follow the screen instructions to complete the update process.

ASUS TS100-E4/PI2 - Updating the BIOS through the Internet - 4

The ASUS Update utility is capable of updating itself through the Internet. Always update the utility to avail all its features.

ASUS TS100-E4/PI2 - Updating the BIOS through the Internet - 5

text_image ASUS Update V5.25.01 Select the BIOS Version Please select the version you want. Please choose BIOS file from combo box. What's New Please choose Please choose 1005 (05/17/2002) 1007 (03/12/2002) 1008 (09/13/2002)

Updating the BIOS through a BIOS file

To update the BIOS through a BIOS file:

  1. Launch the ASUS Update utility from the Windows® desktop by clicking Start > Programs > ASUS > ASUSUpdate > ASUSUpdate. The ASUS Update main window appears.
  2. Select Update BIOS from a file option from the drop-down menu, then click Next.

ASUS TS100-E4/PI2 - Updating the BIOS through a BIOS file - 1

text_image Select the Update Method 1. Update/Save BIOS from/to a file. 2. Update BIOS from the Internet - Update system BIOS using a specified BIOS image file on ASUS Web Site. 3. Download BIOS from the Internet - Download a specified BIOS image file via Internet for later usage. 4. Check BIOS Information Update BIOS from a file Save current BIOS to a file Update BIOS from a file Update BIOS from the Internet Download BIOS from the Internet Check BIOS Information Options
  1. Locate the BIOS file from the Open window, then click Save.
  2. Follow the screen instructions to complete the update process.

4.2 BIOS setup program

This motherboard supports a programmable Low-Pin Count (LPC) chip that you can update using the provided utility described in section “4.1 Managing and updating your BIOS.”

Use the BIOS Setup program when you are installing a motherboard, re-configuring your system, or prompted to "Run Setup." This section explains how to configure your system using this utility.

Even if you are not prompted to use the Setup program, you can change the configuration of your computer in the future. For example, you can enable the security password feature or change the power management settings. This requires you to reconfigure your system using the BIOS Setup program so that the computer can recognize these changes and record them in the CMOS RAM of the LPC chip.

The LPC chip on the motherboard stores the Setup utility. When you start up the computer, the system provides you with the opportunity to run this program. Press during the Power-On Self-Test (POST) to enter the Setup utility; otherwise, POST continues with its test routines.

If you wish to enter Setup after POST, reboot the system by doing any of the following procedures:

  • Restart using the OS standard shut-down procedure.
  • Press ++ simultaneously.
  • Press the reset button on the system chassis.
  • Press the power button to turn the system off then back on.

ASUS TS100-E4/PI2 - BIOS setup program - 1

Using the power button, reset button, or the ++ keys to force reset from a running operating system can cause damage to your data or system. We recommend to always shut-down the system properly from the operating system.

The Setup program is designed to make it as easy to use as possible. Being a menu-driven program, it lets you scroll through the various sub-menus and make your selections from the available options using the navigation keys.

ASUS TS100-E4/PI2 - BIOS setup program - 2

  • The default BIOS settings for this motherboard apply for most conditions to ensure optimum performance. If the system becomes unstable after changing any BIOS settings, load the default settings to ensure system compatibility and stability. Select the Load Default Settings item under the Exit Menu. See section “5.8 Exit Menu.”
  • The BIOS setup screens shown in this section are for reference purposes only, and may not exactly match what you see on your screen.
  • Visit the ASUS website (www.asus.com) to download the latest BIOS file for this motherboard.

4.2.1 BIOS menu screen

ASUS TS100-E4/PI2 - BIOS menu screen - 1

text_image Menu items Menu bar Configuration fields Main Advanced Power Boot Exit BIOS SETUP UTILITY System Time [11:10:19] System Date [Tue 01/01/2002] Legacy Diskette A [Disabled] Primary IDE Master : [Not Detected] Primary IDE Slave : [Not Detected] Third IDE Master : [Not Detected] Third IDE Slave : [Not Detected] Fourth IDE Master : [Not Detected] Fourth IDE Slave : [Not Detected] IDE Configuration System Information General help Use [ENTER]. [TAB], or [SHIFT-TAB] to select a field. Use [+] or [-] to configure system time. ←→ Select Screen ↑↓ Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit v02.58 (C) Copyright 1985-2004, American Megatrends, Inc. Navigation keysSub-menu items

4.2.2 Menu bar

The menu bar on top of the screen has the following main items:

Main For changing the basic system configuration

Advanced For changing the advanced system settings

Power For changing the Advanced Power Management (APM) configuration

Boot For changing the system boot configuration

Exit For selecting the exit options and loading default settings

To select an item on the menu bar, press the right or left arrow key on the keyboard until the desired item is highlighted.

4.2.3 Navigation keys

At the bottom right corner of a menu screen are the navigation keys for that particular menu. Use the navigation keys to select items in the menu and change the settings.

ASUS TS100-E4/PI2 - Navigation keys - 1

Some of the navigation keys differ from one screen to another.

4.2.4 Menu items

The highlighted item on the menu bar displays the specific items for that menu. For example, selecting Main shows the Main menu items.

The other items (Advanced, Power, Boot, and Exit) on the menu bar have their respective menu items.

ASUS TS100-E4/PI2 - Menu items - 1

text_image BOS SIOF OVLIMY Main Advanced Power Boot Exit System Time [11:10:19] System Date [Tue 01/01/2002] Legacy Diskette A [1.44M, 3.5 in] Primary IDE Master: [Not Detected] Primary IDE Slave : [Not Detected] Third IDE Master : [Not Detected] Third IDE Slave : [Not Detected] Fourth IDE Master : [Not Detected] Fourth IDE Slave : [Not Detected] IDE Configuration System Information Use [ENTER], [TAB], or [SHIFT TAB] to select a field. Use [+] or [-] to configure system time. Select Screen Select Item + - Change Option F1 General Help F10 Save and Exit ESC Exit Main menu items

4.2.5 Sub-menu items

A solid triangle before each item on any menu screen means that the item has a sub-menu. To display the sub-menu, select the item and press .

4.2.6 Configuration fields

These fields show the values for the menu items. If an item is user-configurable, you can change the value of the field opposite the item. You cannot select an item that is not user-configurable.

A configurable field is enclosed in brackets, and is highlighted when selected. To change the value of a field, select it then press to display a list of options. Refer to “5.2.7 Pop-up window.”

4.2.7 Pop-up window

Select a menu item then press to display a pop-up window with the configuration options for that item.

4.2.8 Scroll bar

A scroll bar appears on the right side of a menu screen when there are items that do not fit on the screen. Press the Up/Down arrow keys or / keys to display the other items on the screen.

4.2.9 General help

At the top right corner of the menu screen is a brief description of the selected item.

ASUS TS100-E4/PI2 - General help - 1

text_image AEM Configuration Power Management/APM [Enabled] Video Power Down Mode [Suspend] Hand Disk Power Down Mode [Suspend] Suspend Time Out(Minute) [Disabled] Throttle Slow Clock Ratio [30s] Power Button Function Restore on AC Power Loss Power On by PS/2 Keyboard [Disabled] Power On by PS/2 Mouse [Disabled] Power On Ring [Disabled] Power On FML [Disabled] Power On BTC Alarm [Disabled] Use [ENTER], [TAB], or [SHIFT-TAB] to select a field. Use (+) or (-) to configure system time. Select Screen Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit Pop-up window Scroll bar

4.3 Main menu

When you enter the BIOS Setup program, the Main menu screen appears, giving you an overview of the basic system information.

ASUS TS100-E4/PI2 - Main menu - 1

Refer to section “5.2.1 BIOS menu screen” for information on the menu screen items and how to navigate through them.

BIOS SETUP UTILITY Main Advanced Power Boot Exit
System Time [11:10:19] System Date [Tue 01/01/2002] Legacy Diskette A [Enabled]Use [ENTER]. [TAB], or [SHIFT-TAB] to select a field. Use [+] or [-] to configure system time. ↔ Select Screen ↑↓ Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit
Primary IDE Master : [Not Detected] Primary IDE Slave : [Not Detected] Third IDE Master : [Not Detected] Third IDE Slave : [Not Detected] Fourth IDE Master : [Not Detected] Fourth IDE Slave : [Not Detected] IDE Configuration
System Information

4.3.1 System Time [xx:xx:xx]

Allows you to set the system time.

4.3.2 System Date [Day xx/xx/xxxx]

Allows you to set the system date.

4.3.3 Legacy Diskette A [Enabled]

Sets the type of floppy drive installed. Configuration options: [Disabled] [360K, 5.25 in.] [1.2M, 5.25 in.] [720K, 3.5 in.] [1.44M, 3.5 in.] [2.88M, 3.5 in.]

4.3.4 Primary, Third, Fourth IDE Master/Slave

The BIOS automatically detects the connected IDE devices. There is a separate sub-menu for each IDE device. Select a device item, then press to display the IDE device information.

Primary IDE Master Device : Not Detected Type [Auto] LBA/Large Mode [Auto] Block (Multi-sector Transfer)M [Auto] PIO Mode [Auto] DMA Mode [Auto] SMART Monitoring [Auto] 32Bit Data Transfer [Enabled]Select the type of device connected to the system. ←→ Select Screen ↑↓ Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit

The BIOS automatically detects the values opposite the dimmed items (Device, Vendor, Size, LBA Mode, Block Mode, PIO Mode, Async DMA, Ultra DMA, and SMART monitoring). These values are not user-configurable. These items show N/A if no IDE device is installed in the system.

Type [Auto]

Selects the type of IDE drive. Setting to [Auto] allows automatic selection of the appropriate IDE device type. Select [CDROM] if you are specifically configuring a CD-ROM drive. Select [ARMD] (ATAPI Removable Media Device) if your device is either a ZIP, LS-120, or MO drive.

Configuration options: [Not Installed] [Auto] [CDROM] [ARMD]

LBA/Large Mode [Auto]

Enables or disables the LBA mode. Setting to [Auto] enables the LBA mode if the device supports this mode, and if the device was not previously formatted with LBA mode disabled. Configuration options: [Disabled] [Auto]

Block (Multi-sector Transfer) [Auto]

Enables or disables data multi-sectors transfers. When set to [Auto], the data transfer from and to the device occurs multiple sectors at a time if the device supports multi-sector transfer feature. When set to [Disabled], the data transfer from and to the device occurs one sector at a time. Configuration options: [Disabled] [Auto]

PIO Mode [Auto]

Selects the PIO mode. Configuration options: [Auto] [0] [1] [2] [3] [4]

DMA Mode [Auto]

Selects the DMA mode. Configuration options: [Auto] [SWDMA0] [SWDMA1] [SWDMA2] [MWDMA0] [MWDMA1] [MWDMA2] [UDMA0] [UDMA1] [UDMA2] [UDMA3] [UDMA4] [UDMA5]

SMART Monitoring [Auto]

Sets the Smart Monitoring, Analysis, and Reporting Technology. Configuration options: [Auto] [Disabled] [Enabled]

32Bit Data Transfer [Enabled]

Enables or disables 32-bit data transfer. Configuration options: [Disabled] [Enabled]

4.3.5 IDE Configuration

The items in this menu allow you to set or change the configurations for the IDE devices installed in the system. Select an item then press if you wish to configure the item.

Main BIOS SETUP UTILITY
IDE Configuration Configure SATA as [Standard IDE] Onboard IDE Operate Mode [Enhanced Mode] Enhanced Mode Support On [S-ATA] IDE Detect Time Out (Sec) [35]Set [Compatible Mode] when Legacy OS (i.e. WIN ME, 98, NT4.0, MS DOS) is used. Set [Enhanced Mode] when Native OS (i.e. WIN2000, WIN XP) is used. ↔ Select Screen ↑↓ Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit
v02.58 (C) Copyright 1985-2004, American Megatrends, Inc.

Configure SATA As [Standard IDE]

Sets the configuration for the Serial ATA connectors supported by the Southbridge chip.

If you want to use the Serial ATA hard disk drives as Parallel ATA physical storage devices, set this item to [Standard IDE].

Onboard IDE Operate Mode [Enhanced Mode]

Allows selection of the onboard IDE operation mode depending on the installed operating system (OS). Set to [Enhanced] if you are using native OS, e.g. Windows® 2000/XP. Set to [Compatible] if you are using legacy OS, e.g. Windows ME/98/NT, MS-DOS. Configuration options: [Disabled] [Compatible] [Enhanced]

ASUS TS100-E4/PI2 - Configure SATA As [Standard IDE] - 1

Set the item Configure SATA as to [RAID] if you want to use or configure the SATA connectors under SuSE Linux Enterprise Server 9.0 SP1 operating system environment. Due to the OS limitation, you must set a SATA RAID to use any SATA device (at least two SATA devices are needed for the RAID configuration). Refer to Chapter 5 and Chapter 6 for details on how to set a SATA RAID.

Set Configure SATA As to [RAID], if you want to create a RAID 0 or RAID1, configurations using the Intel® Matrix Storage Manager or if you want to create a RAID 0 or RAID 1 configurations using the LSI Logic Embedded SATA RAID Setup Utility.

OnBoard Serial-ATA BOOTROM [Disabled]

Allows you to enable or disable the Onboard Serial-ATA BOOTROM.

Configuration options: [Disabled] [Enabled]

The AHCI allows the onboard storage driver to enable advanced Serial ATA features that enhance storage performance on random workloads by allowing the drive to internally optimize the order of commands.

If you want the Serial ATA hard disk drives to use the Advanced Host Controller Interface (AHCI), set this item to [AHCI]. For details on AHCI, go to: www.intel.com/support/chipsets/imst/sb/CS-012304.htm

www.intel.com/support/chipsets/imst/sb/CS-012305.htm

The SATA controller is set to Native mode when this item is set to [RAID] or [AHCI].

ALPE and ASP [Disabled]

Allows you to enable or disable the Aggressive Link Power Management and Aggressive Slumber/Partial Enabled. Configuration options: [Disabled] [Enabled]

Stagger Spinup Support [Disabled]

Allows you to enable or disable the Stagger Spinup support function.

Configuration options: [Disabled] [Enabled]

AHCI Port 3 Interlock Switch [Disabled]

Allows you to enable or disable AHCI Port 3 Interlock Switch. Configuration options: [Disabled] [Enabled]

4.3.6 System Information

This menu gives you an overview of the general system specifications. The BIOS automatically detects the items in this menu.

Main BIOS SETUP UTILITY
AMIBIOS Version : 0115 Build Date : 08/14/06 Processor Type : Genuine Intel(R) CPU 2.80GHz Speed : 2800 MHz Count : 2 System Memory Usable Size : 1024MB←→ Select Screen ↑↓ Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit

AMI BIOS

Displays the auto-detected BIOS information.

Processor

Displays the auto-detected CPU specification.

System Memory

Displays the auto-detected total system memory.

4.4 Advanced menu

The Advanced menu items allow you to change the settings for the CPU and other system devices.

ASUS TS100-E4/PI2 - Advanced menu - 1

Take caution when changing the settings of the Advanced menu items. Incorrect field values can cause the system to malfunction.

Main Advanced Power BIOS SETUP UTILITY Boot Exit
USB Configuration MPS Configuration Remote Access Configuration Trusted Configuration CPU Configuration Chipset Onboard Deviced Configuration PCIPnPConfigure the Multi-Processor Table. ←→ Select Screen ↑↓ Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit

4.4.1 USB Configuration

Advanced BIOS SETUP UTILITY
USB ConfigurationEnables USB host controller.
Module Version - 2.24.0-10.4
USB Devices Enabled: None
USB Function [4 USB Ports] Legacy USB Support [Enabled] USB2.0 Controller [Enabled] USB2.0 Controller mode [HiSpeed] BIOS EHCI Hand-Off [Enabled]
←→ Select Screen ↑↓ Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit
v02.58 (C) Copyright 1985-2004, American Megatrends, Inc.

USB Function [4 USB Ports]

Allows you to enable a specific number of USB ports, or disable the USB function. Configuration options: [Disabled] [2 USB Ports] [4 USB Ports]

Legacy USB Support [Enabled]

Allows you to enable or disable support for legacy USB. The AUTO option disables legacy support if there is no USB device connected. Configuration options: [AUTO] [2 USB Ports] [4 USB Ports]

USB 2.0 Controller [Enabled]

Allows you to enable or disable the USB 2.0 controller. Configuration options: [Enabled] [Disabled]

USB2.0 Controller mode [HiSpeed]

Allows you to select the USB2.0 controller mode. Configuration options: [HiSpeed] [FullSpeed]

BIOS EHCI Hand-Off [Enabled]

Allows yout to enable or disable the BIOS EHCI Hand-Off support function. Configuration options: [Disabled] [Enabled]

4.4.2 MPS Configuration

BIOS SETUP UTILITY Advanced
MPS Configuration MPS Revision [1.4]Select MPS Revision. ↔ Select Screen ↑↓ Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit
v02.58 (C) Copyright 1985-2004, American Megatrends, Inc.

MPS Revision [1.4]

Allows you to select the multi-processor system version. Configuration options: [1.1] [1.4]

4.4.3 Remote Access Configuration

The items in this menu allows you to configure the Remote Access features. Select an item then press to display the configuration options.

BIOS SETUP UTILITY Advanced
Configure Remote Access type and parameters Remote Access [Enabled] Serial port number [COM1] Base Address, IRQ [3F8h,4] Serial Port Mode [115200 8, n,1] Flow Control [None] Redirection After BIOS POST [Always] Terminal Type [ANSI] VT-UTF8 Combo Key Support [Enabled] Media Type [Serial]Select Remote Access type. ←→ Select Screen ↑↓ Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit

Remote Access [Disabled]

Enables or disables the remote access feature.

Configuration options: [Disabled] [Enabled]

ASUS TS100-E4/PI2 - Remote Access [Disabled] - 1

The following items appear only when the Remote Access item is set to [Enabled].

Serial port number [COM1]

Allows you to select a serial port for console redirection. Configuration options: [COM1] [COM2]

Serial Port Mode [115200 8, n,1]

Allows you to select a serial port mode. Configuration options: [115200 8,n,1] [57600 8,n,1] [38400 8,n,1] [19200 8,n,1] [09600 8,n,1]

Flow Control [None]

Allows you to set the flow control for console redirection. Configuration options: [None] [Hardware] [Software]

Redirection After BIOS POST [Always]

Sets the redirection mode after the BIOS Power-On Self-Test (POST). Some operating systems may not work when this item is set to Always.

Configuration options: [Disabled] [Boot Loader] [Always]

Terminal Type [ANSI]

Allows you to select the target terminal type. Configuration options: [ANSI] [VT100] [VT-UTF8]

VT-UTF8 Combo Key Support [Enabled]

Allows you to enable or disable VT-UTF8 Combination Key Support for ANSI/VT100 terminals. Configuration options: [Enabled] [Disabled]

Media Type [Serial]

Allows you to select the media for console redirection. Configuration options: [Serial] [LAN] [Serial + LAN]

4.4.4 Trusted Computing

ASUS TS100-E4/PI2 - Trusted Computing - 1

text_image BIOS SETUP UTILITY Advanced Trusted Computing ↔ Select Screen ↑↓ Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit v02.58 (C)Copyright 1985-2004, American Megatrends, Inc.

Use this option to configure settings related to trusted computing innovations.

ASUS TS100-E4/PI2 - Trusted Computing - 2

You need to install ASUS TPM card to make this feature function.

4.4.5 CPU Configuration

The items in this menu show the CPU-related information that the BIOS automatically detects.

BIOS SETUP UTILITY Advanced
Configure Advanced CPU settings Manufacturer: Intel Brand String: Genuine Intel(R) CPU 2.80GHz Frequency : 2800 MHz FSB Speed : 800 MHz Cache L1 : 32 KB Cache L2 : 2048 KB Cache L3 : 0 KB Ratio Status: Unlocked (Max:14, Min:14) Ratio Actual Value: 14 Max CPUID Value Limit [Disabled] Execute Disabled Function [Disabled] Enhance C1 Control [Auto] Virtualization Technology [Enabled] CPU Internal Thermal Control [Auto] Intel Speedstep tech [Automatic]Sets the ratio between CPU Core Clock and the FSB Frequency. NOTE: If an invalid ratio is set in CMOS then actual and setpoint values may differ. ↔ Select Screen ↑↓ Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit

Max CPUID Value Limit [Disabled]

Setting this item to [Enabled] allows legacy operating systems to boot even without support for CPUs with extended CPUID functions.

Configuration options: [Disabled] [Enabled]

Execute Disabled Function [Disabled]

Allows you to enable or disable the Execute Disabled function. Configuration options: [Disabled] [Enabled]

Enhanced C1 Control [Auto]

Allows you to disable or set to Auto the Enhanced C1 Control. Configuration options: [Auto] [Disabled]

Virtualization Technology [Enabled]

Allows you to enable or disable the Virtualization Technology feature. Configuration options: [Disabled] [Enabled]

CPU Internal Thermal Control [Auto]

Allows you to set CPU internal thermal control. if set to Auto, BIOS automatically check CPU's capability to enable TM or TM2 support. In TM mode, CPU power consumption is reduced; in TM2 mode, CPU core ratio and VID is reduced. Configuration options: [Auto] [Disabled]

Intel Speedstep tech [Automatic]

CPU speed controlled by Operating system. Disabled: Default CPU speed. Configuration options: [Automatic] [Disabled]

4.4.6 Chipset

The Chipset Configuration menu allows you to change the advanced chipset settings. Select an item then press to display the sub-menu.

Advanced Chipset SettingsManual DRAM Frequency Setting or Auto by SPD
DRAM Frequency [Auto] Configure DRAM Timing by SPD [Enabled]
Onboard LAN Boot ROM [Enabled]
PEG Port Configuration
PEG Port [Enabled] PEG Port VC1 Map [TC7] PEG Force x1 [Disabled] Memory Remap Feature [Enabled]←→ Select Screen ↑↓ Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit

DRAM Frequency [Auto]

Allows you to set the DDR operating frequency. Configuration options: [Auto] [533 MHz] [667 MHz]

Configure DRAM Timing by SPD [Enabled]

When this item is enabled, the DRAM timing parameters are set according to the DRAM SPD (Serial Presence Detect). When disabled, you can manually set the DRAM timing parameters through the DRAM sub-items. The following sub-items appear when this item is disabled. Configuration options: [Disabled] [Enabled]

DRAM CAS# Latency [5 Clocks]

Controls the latency between the SDRAM read command and the time the data actually becomes available. Configuration options: [5 Clocks] [4 Clocks] [3 Clocks] [6 Clocks]

DRAM RAS# Precharge [4 Clocks]

Controls idle clocks after issuing a precharge command to the DDR SDRAM. Configuration options: [2 Clocks] [3 Clocks] [4 Clocks] [5 Clocks]

DRAM RAS# to CAS# Delay [4 Clocks]

Controls the latency between the DDR SDRAM active command and the read/write command. Configuration options: [2 Clocks] [3 Clocks] [4 Clocks] [5 Clocks]

DRAM RAS# Activate to Precharge Delay [15 DRAM Clocks]

Configuration options: [1 Clocks] [2 Clocks] \~ [15 Clocks]

DRAM Write Recovery Time [4 Clocks]

Configuration options: [2 Clocks] [3 Clocks] [4 Clocks] [5 Clocks]

Onboard LAN Boot ROM [Enabled]

Allows you to enable or disable the option ROM in the onboard LAN controller. Configuration options: [Disabled] [Enabled]

ASUS TS100-E4/PI2 - Onboard LAN Boot ROM [Enabled] - 1

If Onboard LAN Boot ROM item set to [Disabled], The system also undetected the LAN device while add PCI LAN card.

PEG Port Configuration

PEG Port [Enabled]

Allows you to enable or disable the PCI Express Graphic port. Configuration options: [Enabled] [Disabled]

ASUS TS100-E4/PI2 - PEG Port Configuration - 1

The PEG Force x1 item appear only when the PEG Port item is set to [Enabled].

PEG Port VC1 Map [Enabled]

Configuration options: [TC1] \~ [TC7]

PEG Force x1 [Disabled]

Configuration options: [Disabled] [Enabled]

Memory Remap Feature [Enabled]

Allows you to remap the overlap PCI memory over the total physical memory. Configuration options: [Disabled] [Enabled]

ASUS TS100-E4/PI2 - Memory Remap Feature [Enabled] - 1

Disable this item if you are using RedHat Linux Advanced Server 3.0 UP5/UP6 operating system.

4.4.7 Onboard Devices Configuration

The Onboard Devices Configuration menu allows you to change the onboard devices settings. Select an item then press to display the sub-menu.

BIOS SETUP UTILITY Advanced
Configure Win83627EHG-A Super IO Chipset Serial Port1 Address [3F8/IRQ4] Serial Port2 Address [2F8/IRQ3] Serial Port2 Mode [Normal] Parallel Port Address [378] Parallel Port Mode [ECP] ECP Mode DMA Channel [DMA3] Parallel Port IRQ [IRQ7]ENABLE: Allow remapping of overlapped PCI memory above the total physical memory. DISABLE: Do not allow remapping of memory.

Serial Port1 Address [3F8/IRQ4]

Allows you to select the Serial Port1 base address.

Configuration options: [Disabled] [3F8/IRQ4] [3E8/IRQ4] [2E8/IRQ3]

Serial Port2 Address [2F8/IRQ3]

Allows you to select the Serial Port2 base address.

Configuration options: [Disabled] [2F8/IRQ3] [3E8/IRQ4] [2E8/IRQ3]

Serial Port2 Mode [Normal]

Allows you to select the Serial Port2 mode.

Configuration options: [Normal] [IrDA] [ASK IR]

Parallel Port Address [378]

Allows you to select the Parallel Port base addresses.

Configuration options: [Disabled] [378] [278] [3BC]

Parallel Port Mode [ECP]

Allows you to select the Parallel Port mode.

Configuration options: [Normal] [Bi-directional] [ECP] [EPP]

EPP Version [1.9]

Allows selection of the Parallel Port EPP version. This item appears

when the Parallel Port Mode is set to [EPP] or [ECP & EPP].

Configuration options: [1.9] [1.7]

ECP Mode DMA Channel [DMA3]

Appears when the Parallel Port Mode is set to [ECP] or [ECP & EPP]. This

item allows you to set the Parallel Port ECP DMA.

Configuration options: [DMA0] [DMA1] [DMA3]

Parallel Port IRQ [IRQ7]

Sets the Parallel port IRQ. Configuration options: [IRQ5] [IRQ7]

4.4.8 PCI PnP

The PCI PnP menu items allow you to change the advanced settings for PCI/PnP devices. The menu includes setting IRQ and DMA channel resources for either PCI/PnP or legacy ISA devices, and setting the memory size block for legacy ISA devices.

ASUS TS100-E4/PI2 - PCI PnP - 1

Take caution when changing the settings of the PCI PnP menu items. Incorrect field values can cause the system to malfunction.

Advanced PCI/PnP SettingsNO: Lets the BIOS configure all the devices in the system. YES: Lets the operating system configure Plug and Play (PnP) devices not required for boot if your system has a Plug and Play operating system.
WARNING: Setting wrong values in below sections may cause system to malfunction.
Plug And Play O/S [No]
PCI Latency Timer [64]
Allocate IRQ to PCI VGA [Yes]
Palette Snooping [Disabled]
IRQ-3 assigned to [PCI Device]
IRQ-4 assigned to [PCI Device]
IRQ-5 assigned to [PCI Device]
IRQ-7 assigned to [PCI Device]
IRQ-9 assigned to [PCI Device]
IRQ-10 assigned to [PCI Device]
IRQ-11 assigned to [PCI Device]
IRQ-14 assigned to [PCI Device]
IRQ-15 assigned to [PCI Device]

Plug And Play O/S [No]

When set to [No], BIOS configures all the devices in the system. When set to [Yes] and if you install a Plug and Play operating system, the operating system configures the Plug and Play devices not required for boot. Configuration options: [No] [Yes]

PCI Latency Timer [64]

Allows you to select the value in units of PCI clocks for the PCI device latency timer register. Configuration options: [32] [64] [96] [128] [160] [192] [224] [248]

Allocate IRQ to PCI VGA [Yes]

When set to [Yes], BIOS assigns an IRQ to PCI VGA card if the card requests for an IRQ. When set to [No], BIOS does not assign an IRQ to the PCI VGA card even if requested. Configuration options: [No] [Yes]

Palette Snooping [Disabled]

When set to [Enabled], the pallete snooping feature informs the PCI devices that an ISA graphics device is installed in the system so that the latter can function correctly. Configuration options: [Disabled] [Enabled]

IRQ-xx assigned to [PCI Device]

When set to [PCI Device], the specific IRQ is free for use of PCI/PnP devices. When set to [Reserved], the IRQ is reserved for legacy ISA devices. Configuration options: [PCI Device] [Reserved]

4.5 Power Configuration

The Power Configuration menu items allow you to change the settings for the ACPI and Advanced Power Management (APM) features. Select an item then press to display the configuration options.

Main Advanced Power BIOS SETUP UTILITY Boot Exit
ACPI APIC Support [Enabled] ▶ APM Configuration ▶ Hardware MonitorInclude ACPI APIC table pointer to RSDT pointer list. ↔ Select Screen ↑↓ Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit

ACPI APIC Support [Enabled]

Allows you to enable or disable the Advanced Configuration and Power Interface (ACPI) support in the Advanced Programmable Interrupt Controller (APIC). When set to Enabled, the ACPI APIC table pointer is included in the RSDT pointer list. Configuration options: [Disabled] [Enabled]

4.5.1 APM Configuration

ASUS TS100-E4/PI2 - APM Configuration - 1

text_image BIOS SETUP UTILITY Power APM Configuration Restore on AC Power Loss [Last State] Resume On By RTC Alarm [Disabled] Power On By PS/2 Keyboard [Disabled] Power On By PS/2 Mouse [Disabled] Resume On Ring [Disabled] Resume On LAN [Disabled] Power On By PCI Devices [Disabled] Keyboard Wakeup Password : Not Installed Options Power Off Power On Last State ←→ Select Screen ↑↓ Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit v02.58 (C) Copyright 1985-2004, American Megatrends, Inc.

Restore on AC Power Loss [Last State]

When set to Power Off, the system goes into off state after an AC power loss. When set to Power On, the system goes on after an AC power loss. When set to Last State, the system goes into either off or on state, whatever the system state was before the AC power loss. Configuration options: [Power Off] [Power On] [Last State]

Resume On By RTC Alarm [Disabled]

Allows you to enable or disable RTC to generate a wake event. When this item is set to [Enabled], the items RTC Alarm Date, RTC Alarm Hour, RTC Alarm Minute, and RTC Alarm Second appear with set values.

Configuration options: [Disabled] [Enabled]

ASUS TS100-E4/PI2 - Resume On By RTC Alarm [Disabled] - 1

The following items appear only when the Resume On By RTC Alarm item is set to Enabled.

RTC Alarm Date (Days) [15]

To set the alarm date, highlight this item and press the <+> or <-> key to make the selection. Configuration options: [Everyday] [1] [2] [3]...[31]

System Time [12:30:30]

To set the alarm time, highlight this item and press the <+> or <-> key to make the selection.

Power On By PS/2 Keyboard [Disabled]

Allows you to use specific keys on the keyboard to turn on the system. This feature requires an ATX power supply that provides at least 1A on the +5VSB lead. Configuration options: [Disabled] [Enabled]

Power On By PS/2 Mouse [Disabled]

When set to [Enabled], this parameter allows you to use the PS/2 mouse to turn on the system. This feature requires an ATX power supply that provides at least 1A on the +5VSB lead. Configuration options: [Disabled] [Enabled]

Resume On Ring [Disabled]

When set to [Enabled], the system enables the RI to generate a wake event while the computer is in Soft-off mode.

Configuration options: [Disabled] [Enabled]

Power on By PCI Devices [Disabled]

When set to [Enabled], this parameter allows you to turn on the system through a PCI LAN or Modem card. This Feature requires an ATX power supply that provides at least 1A on the +5VSB lead.

Configuration options: [Disabled] [Enabled]

4.5.2 Hardware Monitor

ASUS TS100-E4/PI2 - Hardware Monitor - 1

text_image BIOS SETUP UTILITY Power Hardware Monitor CPU Temperature [49°C/120°F] MB1 Temperature [47°C/114°F] MB2 Temperature [47°C/114°F] CPU Fan1 Speed [3884RPM] CPU Fan2 Speed [N/A] Front Fan1 Speed [N/A] Front Fan2 Speed [N/A] Rear Fan1 Speed [N/A] Rear Fan2 Speed [N/A] Smart Fan Control [Smart Fan] VCORE Voltage [ 1.320V] 3.3V Voltage [ 3.345V] 5V Voltage [ 5.094V] CPU1 Temperature ↔ Select Screen ↑↓ Select Iten +- Change Option F1 General Help F10 Save and Exit ESC Exit vMM.mm Copyright 1985-2002, American Megatrends, Inc.

Use the arrow down key to display additional items.

ASUS TS100-E4/PI2 - Hardware Monitor - 2

text_image 5VSB Voltage [ 4.980V] VBAT Voltage [ 3.120V] 12V Voltage [12.053V] F10 Save and Exit ESC Exit vMM.mm Copyright 1985-2002. American Megatrends. Inc.

CPU Temperature [xxx°C/xxx°F] MB1 Temperature [xxx°C/xxx°F]

The onboard hardware monitor automatically detects and displays the motherboard and CPU temperatures. Select [Ignored] if you do not wish to display the detected temperatures.

CPU Fan1/2 Speed [xxxxRPM] or [N/A] Front Fan1/2 Speed [xxxxRPM] or [N/A] Rear Fan1/2 Speed [xxxxRPM] or [N/A]

The onboard hardware monitor automatically detects and displays the CPU, front, and rear fan speed in rotations per minute (RPM). If the fan is not connected to the motherboard, the field shows N/A.

Smart Fan Control [Enabled]

Allows you to enable or disable the ASUS Smart Fan feature that smartly adjusts the fan speeds for more efficient system operation. Configuration options: [Disabled] [Enabled]

ASUS TS100-E4/PI2 - Smart Fan Control [Enabled] - 1

The CPU Temperature and MB Temperature items appear when you set the Smart Fan Control item to [Enabled].

VCORE1 Voltage, VCORE2 Voltage, 3.3V Voltage, 5V Voltage, 5VSB Voltage, VBAT Voltage, 12V Voltage

The onboard hardware monitor automatically detects the voltage outputs through the onboard voltage regulators.

4.6 Boot menu

The Boot menu items allow you to change the system boot options. Select an item then press to display the sub-menu.

Main Advanced Power Boot Exit BIOS SETUP UTILITY
Boot SettingsSpecifies the Boot Device Priority sequence. A virtual floppy disk drive (Floppy Drive B:) may appear when you set the CD-ROM drive as the first boot device. ←→ Select Screen ↑↓ Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit
▶ Boot Device Priority ▶ Hard Disk Drives
▶ Boot Settings Configuration ▶ Security

4.6.1 Boot Device Priority

ASUS TS100-E4/PI2 - Boot Device Priority - 1

text_image BIOS SETUP UTILITY Boot Boot Device Priority 1st Boot Device [Removable dev.] 2nd Boot Device [ATAPI CD-ROM] 3rd Boot Device [RAID LSI Logic MB] 4th Boot Device [Network: MBA V8.3.9] 5th Boot Device [Network: MBA V8.3.9]

1st Boot Device [1st FLOPPY Drive] 2nd Boot Device [Network: MBA v7.7.5] 3rd Boot Device [Network: MBA v7.7.5]

These items specify the boot device priority sequence from the available devices. Configuration options: [xxxxx Drive] [Disabled]

4.6.2 Hard Disk Drives

BIOS SETUP UTILITY Boot
Boot Device PrioritySpecifies the Boot Device Priority sequence from available Hard Drives.
1st Drive [HDD: XXXXXXXX Drive]
2nd Drive [HDD: XXXXXXXX Drive]

1st \~ xxth Drive [HDD: XXXXXXXX Drive]

These items specify the boot device priority sequence from the available hard disk drives. The number of device items that appears on the screen depends on the number of devices installed in the system. Configuration options: [xxxxx Drive] [Disabled]

4.6.3 Boot Settings Configuration

BOOT Settings Configuration Quick Boot [Enabled] Full Screen Logo [Enabled] AddOn ROM Display Mode [Force BIOS] Bootup Num-Lock [On] PS/2 Mouse Support [Auto] Wait For 'F1' If Error [Enabled] Hit 'DEL' Message Display [Enabled] Interrupt 19 Capture [Enabled]Allows BIOS to skip certain tests while booting. This will decrease the time needed to boot the system. ←→ Select Screen ↑↓ Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit

Quick Boot [Enabled]

Enabling this item allows the BIOS to skip some power on self tests (POST) while booting to decrease the time needed to boot the system. When set to [Disabled], BIOS performs all the POST items.

Configuration options: [Disabled] [Enabled]

Full Screen Logo [Enabled]

Allows you to enable or disable the full screen logo display feature. Configuration options: [Disabled] [Enabled]

ASUS TS100-E4/PI2 - Full Screen Logo [Enabled] - 1

Set this item to [Enabled] to use the ASUS MyLogo2™ feature.

AddOn ROM Display Mode [Force BIOS]

Allows you to set display mode for optional ROM. Configuration options: [Force BIOS] [Keep Current]

Bootup Num-Lock [On]

Allows you to select the power-on state for the NumLock. Configuration options: [Off] [On]

PS/2 Mouse Support [Auto]

Allows you to enable or disable support for PS/2 mouse. Configuration options: [Disabled] [Enabled] [Auto]

Wait for 'F1' If Error [Enabled]

When set to Enabled, the system waits for the F1 key to be pressed when error occurs. Configuration options: [Disabled] [Enabled]

Hit 'DEL' Message Display [Enabled]

When set to Enabled, the system displays the message “Press DEL to run Setup” during POST. Configuration options: [Disabled] [Enabled]

Interrupt 19 Capture [Enabled]

When set to [Enabled], this function allows the option ROMs to trap Interrupt 19. Configuration options: [Disabled] [Enabled]

4.6.4 Security

The Security menu items allow you to change the system security settings. Select an item then press to display the configuration options.

ASUS TS100-E4/PI2 - Security - 1

text_image BIOS SETUP UTILITY Boot Security Settings Supervisor Password : Not Installed User Password : Not Installed Change Supervisor Password Change User Password (to change password. again to disable password. ←→ Select Screen ↑↓ Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit v02.58 (C) Copyright 1985-2004, American Megatrends, Inc.

Change Supervisor Password

Select this item to set or change the supervisor password. The Supervisor Password item on top of the screen shows the default Not Installed. After you set a password, this item shows Installed.

To set a Supervisor Password:

  1. Select the Change Supervisor Password item, then press .
  2. From the password box, type a password composed of at least six letters and/or numbers, then press .
  3. Confirm the password when prompted.

The message "Password Installed" appears after you successfully set your password.

To change the supervisor password, follow the same steps as in setting a user password.

To clear the supervisor password, select the Change Supervisor Password then press . The message "Password Uninstalled" appears.

ASUS TS100-E4/PI2 - Change Supervisor Password - 1

If you forget your BIOS password, you can clear clear it by erasing the CMOS Real Time Clock (RTC) RAM. See section "2.6 Jumpers" for information on how to erase the RTC RAM.

After you have set a supervisor password, the other items appear to allow you to change other security settings.

Security Settings Supervisor Password : Installed User Password : Not Installed Change Supervisor Password User Access Level [Full Access] Change User Password Clear User Password Password Check [Setup]<Enter> to change password. <Enter> again to disable password.
←→ Select Screen ↑↓ Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit

User Access Level [Full Access]

This item allows you to select the access restriction to the Setup items. Configuration options: [No Access] [View Only] [Limited] [Full Access]

No Access prevents user access to the Setup utility.

View Only allows access but does not allow change to any field.

Limited allows changes only to selected fields, such as Date and Time.

Full Access allows viewing and changing all the fields in the Setup utility.

Change User Password

Select this item to set or change the user password. The User Password item on top of the screen shows the default Not Installed. After you set a password, this item shows Installed.

To set a User Password:

  1. Select the Change User Password item and press .

  2. On the password box that appears, type a password composed of at least six letters and/or numbers, then press .

  3. Confirm the password when prompted.

The message “Password Installed” appears after you set your password successfully.

To change the user password, follow the same steps as in setting a user password.

Clear User Password

Select this item to clear the user password.

Password Check [Setup]

When set to [Setup], BIOS checks for user password when accessing the Setup utility. When set to [Always], BIOS checks for user password both when accessing Setup and booting the system.

Configuration options: [Setup] [Always]

4.7 Exit menu

The Exit menu items allow you to load the optimal or failsafe default values for the BIOS items, and save or discard your changes to the BIOS items.

Main Advanced Power BIOS SETUP UTILITY Boot Exit
Exit Options Exit & Save Changes Exit & Discard Changes Discard Changes Load Setup DefaultsExit system setup after saving the changes. F10 key can be used for this operation. ←→ Select Screen ↑↓ Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit

ASUS TS100-E4/PI2 - Exit menu - 1

If you made changes to any of the settings in the menus, pressing does not immediately exit this menu. A confirmation window appears and prompts you to either save your changes or cancel the command. Select one of the options from this menu to exit.

Exit & Save Changes

Select this option then press , or simply press , to save your changes to CMOS before exiting the Setup utility.

When a confirmation window appears, select [OK] then press to save your changes and exit Setup. If you wish to cancel the command, select [Cancel] then press to return to the Exit menu.

Exit & Discard Changes

Select this option then press to exit the Setup utility without saving your changes.

When a confirmation window appears, select [OK] then press to discard your changes and exit Setup. If you wish to cancel the command, select [Cancel] then press to return to the Exit menu.

Discard Changes

Select this option then press to discard the changes that you made, and restore the previously saved settings.

When a confirmation window appears, select [OK] then press to discard the changes, and load the previously saved settings. If you wish to cancel the command, select [Cancel] then press to return to the Exit menu.

Load Setup Defaults

Select this option then press to load the optimized settings for each of the Setup menu items.

When a confirmation window appears, select [OK] then press to load the default settings. If you wish to cancel the command, select [Cancel] then press to return to the Exit menu.

Chapter 5

This chapter provides instructions for setting up, creating and configuring RAID sets using the available utilities.

ASUS TS100-E4/PI2 - Chapter 5 - 1

natural_image Black desktop computer tower with visible drive bays and ventilation slots (no text or labels)

CARD conjugation

5.1 RAID configurations

The server system/motherboard comes with the IntelICH7R and the LSI Logic Embedded SATA RAID technology built-in the Intel® ICH7R SouthBridge chipset that allows you to configure IDE and Serial ATA hard disk drives as RAID sets. The motherboard supports the following RAID configurations:

5.1.1 RAID definitions

RAID 0 (Data striping) optimizes two identical hard disk drives to read and write data in parallel, interleaved stacks. Two hard disks perform the same work as a single drive but at a sustained data transfer rate, double that of a single disk alone, thus improving data access and storage. Use of two new identical hard disk drives is required for this setup.

RAID 1 (Data mirroring) copies and maintains an identical image of data from one drive to a second drive. If one drive fails, the disk array management software directs all applications to the surviving drive as it contains a complete copy of the data in the other drive. This RAID configuration provides data protection and increases fault tolerance to the entire system. Use two new drives or use an existing drive and a new drive for this setup. The new drive must be of the same size or larger than the existing drive.

Intel® Matrix Storage. The Intel® Matrix Storage technology supported by the ICH7R chip allows you to create a RAID 0 and a RAID 1 set using only two identical hard disk drives. The Intel® Matrix Storage technology creates two partitions on each hard disk drive to create a virtual RAID 0 and RAID 1 sets. This technology also allows you to change the hard disk drive partition size without losing any data.

ASUS TS100-E4/PI2 - RAID definitions - 1

If you want to boot the system from a hard disk drive included in a created RAID set, copy first the RAID driver from the support CD to a floppy disk before you install an operating system to the selected hard disk drive. Refer to section "6.1 RAID driver installation" for details.

5.1.2 Installing Serial ATA hard disks

The motherboard supports Serial ATA hard disk drives. For optimal performance, install identical drives of the same model and capacity when creating a disk array.

To install the SATA hard disks for a RAID configuration:

  1. Install the SATA hard disks into the drive bays.
  2. Connect the SATA signal cables.
  3. Connect a SATA power cable to the power connector on each drive.

5.1.3 Setting the RAID item in BIOS

You must set the RAID item in the BIOS Setup before you can create a RAID set(s). To do this:

  1. Enter the BIOS Setup during POST.
  2. Go to the Main Menu, select IIE Configuration, then press .
  3. Select the item Configure SATAAs, then press to display the configuration options.
  4. Select RAID from the Configure SATA As item options, then press .
  5. Select the item Onboard SerialATABOOTROM, press , then select Enabled from the options.
  6. Save your changes, then exit the BIOS Setup.

ASUS TS100-E4/PI2 - Setting the RAID item in BIOS - 1

Refer to Chapter 4 for details on entering and navigating through the BIOS Setup.

5.1.4 RAID configuration utility

Depending on the RAID_SEL1 jumper setting and the operating system, you can select a utility to create a RAID set. Refer to section "3.2 Jumpers" for details on the RAID_SEL1 jumper settings.

Use the Intel® Matrix Storage Manager to create a RAID 0 or RAID 1 set under Windows® 2000/2003 Server/XP operating system.

Use the LSI Logic Embedded SATA RAID Setup Utility to create a RAID 0 or RAID 1 under Windows® 2000/2003 Server or Red Hat® Enterprise ver. 3.0 operating system.

Refer to the succeeding sections for details on how to use the RAID configuration utilities.

5.2 Intel® Matrix Storage Manager Option ROM Utility

The Intel ^® Matrix Storage Manager Option ROM utility allows you to create RAID 0 or RAID 1 from Serial ATA hard disk drives that are connected to the Serial ATA connectors supported by the Southbridge.

To enter the Intel® Application Accelerator RAID Option ROM utility:

  1. Install all the Serial ATA hard disk drives.
  2. Turn on the system.
  3. During POST, press + to display the utility main menu.

ASUS TS100-E4/PI2 - Intel® Matrix Storage Manager Option ROM Utility - 1

text_image Intel(R) Matrix Storage Manager Option ROM v5.0.0.1032 ICH7R wRAID5 Copyright(C) 2003-05 Intel Corporation. All Rights Reserved. [ MAIN MENU ] 1. Create RAID Volume 2. Delete RAID Volume 3. Reset Disks to Non-RAID 4. Exit [ DISK/VOLUME INFORMATION ] RAID Volumes: None defined. Physical Disks: Port Drive Model Serial # 0XXXXXXXXXXXX XXXXXXXXX XX.XXGB Non-RAID Disk 1XXXXXXXXXXXX XXXXXXXXX XX.XXGB Non-RAID Disk 2XXXXXXXXXXXX XXXXXXXXX XX.XXGB Non-RAID Disk 3XXXXXXXXXXXX XXXXXXXXX XX.XXGB Non-RAID Disk [↑↓]-Select [ESC]-Exit [ENTER]-Select Menu

The navigation keys at the bottom of the screen allow you to move through the menus and select the menu options.

ASUS TS100-E4/PI2 - Intel® Matrix Storage Manager Option ROM Utility - 2

The RAID BIOS setup screens shown in this section are for reference only and may not exactly match the items on your screen.

5.2.1 Creating a RAID 0 set (striped)

To create a RAID 0 set:

  1. From the utility main menu, select 1. Create RAID Volume, then press . This screen appears.

ASUS TS100-E4/PI2 - Creating a RAID 0 set (striped) - 1

text_image Intel(R) Matrix Storage Manager Option ROM v5.0.0.1032 ICH7R wRAID5 Copyright(C) 2003-05 Intel Corporation. All Rights Reserved. [ CREATE ARRAY MENU ] Name: Volume0 RAID Level: RAID0(Stripe) Disks: Select Disks Strip Size: 128KB Capacity: 0.0 GB Create Volume [ DISK/VOLUME INFORMATION ] Enter a string between 1 and 16 characters in length that can be used to uniquely identify the RAID volume. This name is case sensitive and cannot contain special characters. [↑↓]-Change [TAB]-Next [ESC]-Previous Menu [Enter]-Select
  1. Enter a name for the RAID 0 set, then press .
  2. When the RAID Level item is highlighted, press the up/down arrow key to select RAID 0(Stripe), then press .
  3. When the Disks item is highlighted, press to select the hard disk drives to configure as RAID. This SELECT DISKS screen appears.

ASUS TS100-E4/PI2 - Creating a RAID 0 set (striped) - 2

text_image [ SELECT DISKS ] Port Drive Model Serial # Size Status 0XXXXXXXXXX XXXXXXXX XX.XGB Non-RAID Disk 1XXXXXXXXXX XXXXXXXX XX.XGB Non-RAID Disk 2XXXXXXXXXX XXXXXXXX XX.XGB Non-RAID Disk 3XXXXXXXXXX XXXXXXXX XX.XGB Non-RAID Disk Select 2 to 4 disks to use in creating the volume. [↑↓]-Previous/Next [SPACE]-Selects [ENTER]-Selection Complete
  1. Use the up/down arrow key to highlight a drive, then press to select. A small triangle marks the selected drive. Press after completing your selection.

  2. Use the up/down arrow key to select the stripe size for the RAID 0 array, then press . The available stripe size values range from 8 KB to 128 KB. The default stripe size is 128 KB.

ASUS TS100-E4/PI2 - Creating a RAID 0 set (striped) - 3

TIP: We recommend a lower stripe size for server systems, and a higher stripe size for multimedia computer systems used mainly for audio and video editing.

  1. Key in the RAID volume capacity that you want, then press . The default value indicates the maximum allowed capacity.
  2. Press when the Create Volume item is highlighted. This warning message appears.

WARNING: ALL DATA ON SELECTED DISKS WILL BE LOST. Are you sure you want to create this volume? (Y/N):

  1. Press to create the RAID volume and return to the main menu, or to go back to the Create Volume menu.

5.2.2 Creating a RAID 1 set (mirrored)

To create a RAID 1 set:

  1. From the utility main menu, select 1. Create RAID Volume, then press . This screen appears.

ASUS TS100-E4/PI2 - Creating a RAID 1 set (mirrored) - 1

text_image Intel(R) Matrix Storage Manager Option ROM v5.0.0.1032 ICH7R wRAID5 Copyright(C) 2003-05 Intel Corporation. All Rights Reserved. [ CREATE ARRAY MENU ] Name: Volume1 RAID Level: RAID1(Mirror) Disks: Select Disks Strip Size: N/A Capacity: XX.X GB Create Volume [ DISK/VOLUME INFORMATION ] Enter a string between 1 and 16 characters in length that can be used to uniquely identify the RAID volume. This name is case sensitive and cannot contain special characters. [↑↓]-Change [TAB]-Next [ESC]-Previous Menu [Enter]-Select
  1. Enter a name for the RAID 1 set, then press .
  2. When the RAID Level item is highlighted, press the up/down arrow key to select RAID 1(Mirror), then press .
    4 When the Disks item is highlighted, press to select the hard disk drives to configure as RAID. The SELECT DISKS screen appears.
    5 Use the up/down arrow key to highlight a drive, then press to select. A small triangle marks the selected drive. Press after completing your selection.
  3. When the Capacity item is highlighted, key in the RAID volume capacity that you want, then press . The default value indicates the maximum allowed capacity.
  4. Press when the Create Volume item is highlighted. This warning message appears.

ASUS TS100-E4/PI2 - Creating a RAID 1 set (mirrored) - 2

text_image WARNING: ALL DATA ON SELECTED DISKS WILL BE LOST. Are you sure you want to create this volume? (Y/N):
  1. Press to create the RAID volume and return to main menu or to go back to Create Volume menu.

5.2.3 Deleting a RAID set

ASUS TS100-E4/PI2 - Deleting a RAID set - 1

Take caution when deleting a RAID set. You will lose all data on the hard disk drives when you delete a RAID set.

To delete a RAID set:

  1. From the utility main menu, select 2. Delete RAID Volume, then press to display this screen.

ASUS TS100-E4/PI2 - Deleting a RAID set - 2

text_image Intel(R) Matrix Storage Manager Option ROM v5.0.0.1032 ICH7R wRAID5 Copyright(C) 2003-05 Intel Corporation. All Rights Reserved. [ DELETE VOLUME MENU ] Name Level Drives Capacity Status Bootable Volume0 RAIDX(xxxxx) X XXX.XGB Normal Yes [ HELP ] Deleting a volume will destroy the volume data on the drive(s) and cause any member disks to become available as non-RAID disks. WARNING: EXISTING DATA WITHIN THIS VOLUME WILL BE LOST AND NON-RECOVERABLE. [↑↓]-Select [] -Previous Menu [] -Delete Volume
  1. Use the up/down arrow key to select the RAID set you want to delete, then press . This window appears.

ASUS TS100-E4/PI2 - Deleting a RAID set - 3

text_image [ DELETE VOLUME VERIFICATION ] ALL DATA IN THE VOLUME WILL BE LOST! Are you sure you want to delete volume "VolumeX"? (Y/N):
  1. Press to delete the RAID set and return to the utility main menu; otherwise, press to return to the Delete Volume menu.

5.2.4 Resetting Disks to Non-RAID

ASUS TS100-E4/PI2 - Resetting Disks to Non-RAID - 1

Take caution before you reset a RAID volume HDD to non-RAID. Resetting a RAID volume HDD deletes all internal RAID structure on the drive.

To reset a RAID set hard disk drive:

  1. From the utility main menu, select 3. Reset Disks to Non-RAID, then press to display this screen.

ASUS TS100-E4/PI2 - Resetting Disks to Non-RAID - 2

text_image [ RESET RAID DATA ] Resetting RAID data will remove internal RAID structures from the selected RAID disks. By removing these structures, the drive will revert back to a non-RAID disk. WARNING: Resetting a disk causes all data on the disk to be lost. Port Drive Model Serial # Size Status 0 XXXXXXXXXXXXX XXXXXXXX XX.XGB Member Disk 1 XXXXXXXXXXXXX XXXXXXXX XX.XGB Member Disk Select the disks that should be reset. [↑↓]-Previous/Next [SPACE]-Selects [ENTER]-Selection Complete
  1. Use the up/down arrow key to highlight the RAID set drive you want to reset, then press to select.
  2. Press to reset the RAID set drive. A confirmation message appears.
  3. Press to reset the drive or press to return to the utility main menu.
  4. Follow steps 2 to 4 to select and reset other RAID set drives.

5.2.5 Exiting the Intel® Matrix Storage Manager utility

To exit the utility:

  1. From the utility main menu, select 4. Exit, then press . This window appears.

ASUS TS100-E4/PI2 - Exiting the Intel® Matrix Storage Manager utility - 1

text_image [ CONFIRM EXIT ] Are you sure you want to exit? (Y/N):
  1. Press to exit or press to return to the utility main menu.

5.2.6 Rebuilding the RAID

ASUS TS100-E4/PI2 - Rebuilding the RAID - 1

This option is only for the RAID 1, RAID 5 and RAID 10 sets.

Rebuilding the RAID with other non-RAID disk

If any of the SATA hard disk drives included in the RAID array failed, the system displays the status of the RAID volume as “Degraded” during POST. You can rebuild the RAID array with other installed non-RAID disks.

To rebuild the RAID with other non-RAID disk:

  1. At the prompt, press + to enter the Intel Matrix Storage Manager RAID configuration.

  2. If there is a non-RAID SATA Hard Disk available, the utility will prompt to rebuild the RAID. Press , then use up/down arrow keys to select the destination disk or press to exit.

ASUS TS100-E4/PI2 - Rebuilding the RAID with other non-RAID disk - 1

text_image [DEGRADED VOLUME DETECTED] "Degraded" volume and disk available for rebuilding detected. Selecting a disk initiates a rebuild. Rebuild completes in the operating system. Select the port of destination disk for rebuilding (ESC to exit): Port Drive Model Serial# Size 3HDS722580VLSA80 VN6Bxxxx 76.7GB [↑↓] - Previous/Next [Enter] - Selects [ESC] - Exit

ASUS TS100-E4/PI2 - Rebuilding the RAID with other non-RAID disk - 2

Select a destination disk with the same size as the original hard disk.

  1. The utility immediately starts rebuilding after the disk is selected. The status of the degraded RAID volume is changed to "Rebuild".

ASUS TS100-E4/PI2 - Rebuilding the RAID with other non-RAID disk - 3

text_image Copyright(C) 2003-05 Intel Corporation. All Rights Reserved. [ MAIN [ NO ] ] 1. Create RAID Volume 2. Delete RAID Volume 3. Reset Disks to Non-RAID 4. Exit **********[ DISK/VOLUME INFORMATION ]********** RAID Volumes: ID Name Level Strip Size Status Bootable 0 Volume0 RAID1(Mirror) N/A 74.5GB Rebuild Yes Physical Disks: Port Drive Model Serial # 1 ST380013AS 5JV7XSE9 Size Type/Status(Vol ID) 3 HDS722580VLSA80 VN6BHECBW1EKMC 74.5GB Member Disk(0) Volumes with "Rebuild" status will be rebuilt within the operating system. [--]-Select [ESC]-Exit [ENTERI]-Select Menu
  1. Exit the RAID configuration utility and reboot the system.
  2. Select Start > Programs >> Intel Matrix Storage >> Intel Matrix Storage Console or click the Intel Matrix Storage Manager tray icon to load the Intel Matrix Stroage Manager utility.
  3. From the View menu, select Advanced Modesto display the details of the Intel Matrix Storage Console.
  4. From the Volumes view option, select RAID volume to view the rebuilding status. When finished, the status is changed to "Normal".

Rebuilding the RAID with a new hard disk

If any of the SATA hard disk drives included in the RAID array failed, the system displays the status of the RAID volume as "Degraded" during POST. You may replace the disk drive and rebuild the RAID array.

To rebuild the RAID with a new hard disk:

  1. Remove the failed SATA hard disk and install a new SATA hard disk of the same specification into the same SATA Port.

ASUS TS100-E4/PI2 - Rebuilding the RAID with a new hard disk - 1

Select a destination disk with the same size as the original hard disk.

  1. Reboot the system and then follow the steps in section "Rebuilding the RAID with other non-RAID disk" on page 5-12.

5.2.7 Setting the Boot array in the BIOS Setup Utility

You can set the boot priority sequence in the BIOS for your RAID arrays when creating multi-RAID using the Intel® Matrix Storage Manager.

ASUS TS100-E4/PI2 - Setting the Boot array in the BIOS Setup Utility - 1

Set at least one of the arrays bootable to boot from the hard disk.

To set the boot array in the BIOS:

  1. Reboot the system and press to enter the BIOS setup utility during POST.
  2. Go to the Boot menu and select the option Boot Device Priority.
  3. Use up/down arrow keys to select the boot priority and press . Refer to "4.6.1 Boot Device Priority" for details.
  4. From the Exit menu, select Exit & Save Changes, then press .
  5. When the confirmation window appears, select OK, then press .

5.3 LSI Logic Embedded SATA RAID Setup Utility

The LSI Logic Embedded SATA RAID Setup Utility allows you to create RAID 0 or RAID 1 set(s) from SATA hard disk drives connected to the SATA connectors supported by the motherboard Southbridge chip.

ASUS TS100-E4/PI2 - LSI Logic Embedded SATA RAID Setup Utility - 1

The LSI Logic Embedded SATA RAID automatically configures a RAID 1 (Mirrored) set when the SATA is configured as RAID in the BIOS and you installed two hard disk drives without a RAID configuration.

To enter the LSI Logic Embedded SATA RAID Setup Utility:

  1. Turn on the system after installing all the SATA hard disk drives.
  2. During POST, the LSI Logic Embedded SATA RAID Setup Utility automatically detects the installed SATA hard disk drives and displays any existing RAID set(s). Press + to enter the utility.
LSI Logic Embedded SATA RAID BIOS Version 5.4.06091652R
(c)2004 Copyright LSI Logic Corporation. All Rights Reserved.

LSI Logic Embedded SATA RAID Found at PCI Bus No:00 Dev No:1F
Scanning for Port 0 ... Responding. ST380013AS 76319MB UDMA 6
Scanning for Port 1 ... Responding. ST380013AS 76319MB UDMA 6
Scanning for Port 2 ... Responding. ST380023AS 76319MB UDMA 6
Scanning for Port 3 ... Responding. ST380023AS 76319MB UDMA 6

LSI Logic Embedded SATA RAID Not Configured!

New Drive(s) Found.

Press Ctrl-M to run LSI Logic Embedded SATA RAID Setup Utility. 

ASUS TS100-E4/PI2 - LSI Logic Embedded SATA RAID Setup Utility - 2

You may also create a RAID set(s) in a Windows® operating environment using the Global Array Manager (GAM) application. Refer to the GAM user guide in the motherboard support CD for details.

  1. The utility main window appears. Use the arrow keys to select an option from the Management Menu, then press . Refer to the Management Menu descriptions below.

At the bottom of the screen is the legend box. The keys on the legend box allow you to navigate through the setup menu options or execute commands. The keys on the legend box vary according to the menu level.

ASUS TS100-E4/PI2 - LSI Logic Embedded SATA RAID Setup Utility - 3

text_image Management Menu Configure Initialize Objects Rebuild Check Consistency Configure Logical Drive(s) Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
Menu DescriptionDescription
Configure Allows you to create RAID 0 or RAID 1 set using the EasyConfiguration or the New Configuration command. This menu also allows you to view, add, or clear RAID configurations or select the boot drive
Initialize Allows you to initialize the logical drives of a created RAID set
Objects Allows you to initialize logical drives or change the logical drive parameters
Rebuild Allows you to rebuild failed drives
Check Consistency Allows you to check the data consistency of the logical drives of a created RAID set

5.3.1 Creating a RAID set

The LSI Logic Embedded SATA RAID Setup Utility allows you to create a RAID 0 or RAID 1 set using two types of configurations: Easy and New.

In Easy Configuration, the logical drive parameters are set automatically including the size and stripe size (RAID 1 only).

In New Configuration, you manually set the logical drive parameters and assign the set size and stripe size (RAID 1 only).

Using Easy Configuration

To create a RAID set using the Easy Configuration option:

  1. From the utility main menu, highlight Configure, then press .
  2. Use the arrow keys to select Easy Configuration, then press .

ASUS TS100-E4/PI2 - Using Easy Configuration - 1

text_image Configuration Menu Easy Configuration Management New Configuration Configure View/Add Configuration Initialize Clear Configuration Objects Select Boot Drive Rebuild Check Consistency Dofinos Physical Arrays. An Array Will Automatically Become A logical drive Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
  1. The ARRAY SELECTION MENU displays the available drives connected to the SATA ports. Select the drives you want to include in the RAID set, then press . When selected, the drive indicator changes from READY to ONLIN A[X]-[Y], where X is the array number, and Y is the drive number.

ASUS TS100-E4/PI2 - Using Easy Configuration - 2

text_image Easy Configuration - ARRAY SELECTION MENU Management Configure Initialize Objects Rebuild Check Consis PORT 0 0- DENOS - 1- DENOS - Port 0 DISK 114376MB HDS722512VLSA80 V330A6MA4 SPACE-SEL ENTER-EndArray F10-Configure F2-Dry Info F3-Logical Drives

ASUS TS100-E4/PI2 - Using Easy Configuration - 3

The information of the selected hard disk drive displays at the bottom of the screen.

  1. Select all the drives required for the RAID set, then press . The configurable array appears on screen.

ASUS TS100-E4/PI2 - Using Easy Configuration - 4

text_image Easy Configuration - ARRAY SELECTION MENU -- Management -- Configure -- Initialize -- Objects -- Rebuild -- Check Consis PORT # 8-ONLIN 480.00 1-ONLINE 200.00 Port # 1 DISK 114376MB HDS722512VLSA80 V390AGMA- SPACE-SEL ENTER-EndArray F10-Configure F2-Dry Info E3-Logical Drives
  1. Press , select the configurable array, then press .

ASUS TS100-E4/PI2 - Using Easy Configuration - 5

text_image Easy Configuration - ARRAY SELECTION MENU Select Configurable Array(s) Management Configure Initialize Objects Rebuild Check Consis Cursor Keys. SPACE-(Del)Select F2-ChIdInfo F3-SlotInfo F10-Configure ESC-Duit

The logical drive information appears including a Logical Drive menu that allows you to change the logical drive parameters.

ASUS TS100-E4/PI2 - Using Easy Configuration - 6

text_image Logical Drive(s) Configured LD RAID Size %Stripes StripeSz Status 0 1 114376MB 2 64 KB ONLINE Manager Configure Initializ Objects Rebuild Check Con Logical Drive 0 RAID = 1 Size = 114376MB Stripe Size Accept SPAN = NO Choose RAID Level For This Logical Drive Use Cursor Keys To Navigate Between Items And Press Enter To Select On Option
  1. Select RAID from the Logical Drive menu, then press .
  2. Select the RAID level from the menu, then press .

ASUS TS100-E4/PI2 - Using Easy Configuration - 7

You need at least two identical hard disk drives when creating a RAID 1 set.

ASUS TS100-E4/PI2 - Using Easy Configuration - 8

text_image Logical Drive(s) Configured LD RAID Size #Stripes StripeSz Status 0 1 114376MB 2 64 KB ONLINE Managen Configure Initializ- Objects - Rebuild - Check Con- Logical Drive 0 RAID Level RAID = 1 RAID 0 Size = 114376MB RAID 1 Stripe Size Accept SPAN = NO Choose RAID Level For This Logical Drive Use Cursor Keys To Navigate Between Items And Press Enter To Select On Option
  1. When creating a RAID 1 set, select Stripe Size from the Logical Drive menu, then press .

When creating a RAID 0 set, proceed to step 10.

  1. Key in the stripe size, then press .

ASUS TS100-E4/PI2 - Using Easy Configuration - 9

text_image Logical Drive(s) Configured LD RAID Size #Stripes StripeSz Status 0 1 114376MB 2 64 KB ONLINE Managon Configure Initializ Objects Rebuild Check C Enter Stripe Size In KB (4.8,16,32,64,128)? :64 Logical Drive 0 RAID = 1 Size = 114376MB Stripe Size Accept SPAN = NO Enter Stripe Size In KB (4.8,16.32,64,128)? :

ASUS TS100-E4/PI2 - Using Easy Configuration - 10

For server systems, we recommend that you use a lower array block size. For multimedia computer systems used mainly for audio and video editing, we recommend a higher array block size for optimum performance.

  1. When finished setting the selected logical drive configuration, select Accept from the menu, then press .

ASUS TS100-E4/PI2 - Using Easy Configuration - 11

text_image Logical Drive(s) Configured LD RAID Size %Stripes StripeSz Status 0 1 114376MB 2 64 KB ONLINE Managem Configure Initializ Objects Rebuild Check Con- Logical Drive 0 RAID = 1 Size = 114376MB Stripe Size Accept SPAN = NO Accept This Logical Drive Configuration And Go To Next Logical Drive Use Cursor Keys To Navigate Between Items And Press Enter To Select On Option
  1. Follow steps 5 to 10 to configure additional logical drives.
  2. When prompted, save the configuration, then press to return to the Management Menu.

ASUS TS100-E4/PI2 - Using Easy Configuration - 12

text_image Configuration Menu Easy Configuration Management New Configuration Configure View/Add Configuration Save Configuration ? Yes No Logical Drive(s) Configured Objects LD RATIO Size NStripes StripeSz Status Rebuild Check Con 0 1 114376MB 2 64 KB ONLINE Select YES Or NO Use Cursor Keys To Navigate Between Items And Press Enter To Select On Option

Using New Configuration

ASUS TS100-E4/PI2 - Using New Configuration - 1

When a RAID set is already existing, using the New Configuration command erases the existing RAID configuration data. If you do not want to delete the existing RAID set, use the View/Add Configuration command to view or create another RAID configuration.

To create a RAID set using the New Configuration option:

  1. From the utility main menu, highlight Configure, then press .
  2. Use the arrow keys to select New Configuration, then press .

ASUS TS100-E4/PI2 - Using New Configuration - 2

text_image Configuration Menu Easy Configuration Management New Configuration Configure View/Add Configuration Initialize Clear Configuration Objects Select Boot Drive Rebuild Check Consistency Defines Physical Arrays. An Array Will Automatically Become A logical drive Use Cursor Keys To Navigate Between Items And Press Enter To Select On Option
  1. Follow steps 3 to 7 of the previous section.
  2. Select Size from the Logical Drive menu, then press .
  3. Key in the desired logical drive size, then press .

ASUS TS100-E4/PI2 - Using New Configuration - 3

text_image Logical Drive(s) Configured LD RAID Size #Stripes StripeSz Status 0 1 114376MB 2 64 KB ONLINE Manages Configure Initializ Objects Rebuild Check C Enter Logical Drive Size (MB) :114376 Logical Drive 0 RAID = 1 Size = 114376MB Stripe Size Accept SPAN = NO Enter Logical Drive Size (MB) Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
  1. Follow steps 8 to 12 of the previous section to create the RAID set.

5.3.2 Adding or viewing a RAID configuration

You can add a new RAID configuration or view an existing configuration using the View/Add Configuration command.

Adding a new RAID configuration

To add a new RAID configuration:

  1. From the Management Menu, highlight Configure, then press .
  2. Use the arrow keys to select View/Add Configuration, then press .

ASUS TS100-E4/PI2 - Adding a new RAID configuration - 1

text_image Configuration Menu Easy Configuration Management New Configuration Configure View/Add Configuration Initialize Clear Configuration Objects Select Boot Drive Rebuild Check Consistency View/Add To The Existing Configuration Use Cursor Keys To Navigate Between Items And Press Enter To Select On Option
  1. The ARRAY SELECTION MENU displays the available drives connected to the SATA ports. Select the drive(s) you want to include in the RAID set, then press . When selected, the drive indicator changes from READY to ONLINE A[X]-[Y], where X is the array number, and Y is

ASUS TS100-E4/PI2 - Adding a new RAID configuration - 2

text_image View/Add Configuration - ARRAY SELECTION MENU Management Configure Initialize Objects Rebuild Check Consis PORT #: 0-ONLINE 000-010 1-ONLINE 000-00 Port # 0 DISK 114376MB HDS722512VLSA80 V330A6MA SPACE-SQL ENTER-EndArray F10-Configure F2-Dry. Info E3-Logical Drives

ASUS TS100-E4/PI2 - Adding a new RAID configuration - 3

The information of the selected hard disk drive displays at the bottom of the screen.

  1. Select all the drives required for the RAID set, then press . The configurable array appears on screen.

ASUS TS100-E4/PI2 - Adding a new RAID configuration - 4

text_image View/Add Configuration - ARRAY SELECTION MENU -- Management -- Configure -- Initialize -- Objects -- Rebuild -- Check Consis PORT # 8-ONLIN ADD-00 - 1-ONLIN ADD-SOL - Port # 1 DISK 114376MB HDS722512VLSA80 V390A6MR SPACE-SEL ENTER-EndArray F10-Configure F2-Dry Info F3-Logical Drives
  1. Press , select the configurable array, then press .

ASUS TS100-E4/PI2 - Adding a new RAID configuration - 5

text_image View/Add Configuration - ARRAY SELECTION MENU Select Configurable Array(s) Management Configure Initialize Objects Rebuild Check Consis Cursor Keys. SPACE-(De)Select F2-chIdInfo F3-SlotInfo F10-Configure ESC-Quit

The logical drive information appears including a Logical Drive menu that allows you to change the logical drive parameters.

ASUS TS100-E4/PI2 - Adding a new RAID configuration - 6

text_image Logical Drive(s) Configured LD RAID Size #Stripes StripeSz Status 0 1 114376MB 2 64 KB ONLINE Managen Configure Initializ Objects Rebuild Check Con Logical Drive 0 RAID = 1 Size = 114376MB Stripe Size Accept SPAN = NO Choose RAID Level For This Logical Drive Use Cursor Keys To Navigate Between Items And Press Enter To Select On Option
  1. Follow steps 6 to 7 of the Creating a RAID set: Using Easy Configuration section.
  2. Select Size from the Logical Drive menu, then press .
  3. Key in the desired logical drive size, then press .

ASUS TS100-E4/PI2 - Adding a new RAID configuration - 7

text_image Logical Drive(s) Configured LD RAID Size #Stripes StripeSz Status 0 1 114376MB 2 64 KB ONLINE Managers Configure Initializ Objects Rebuild Check C Enter Logical Drive Size (MB) :114376 Logical Drive 0 RAID = 1 Size = 114376MB Stripe Size Accept SPAN = NO Enter Logical Drive Size (MB) Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
  1. Follow steps 8 to 12 of the Creating a RAID set: Using Easy Configuration section to add the new RAID configuration.

5.3.3 Initializing the logical drives

After creating the RAID set(s), you must initialize the logical drives. You may initialize the logical drives of a RAID set(s) using the Initialize or Objects command in the Management Menu.

Using the Initialize command

To initialize the logical drive using the Initialize command:

  1. From the Management Menu, highlight Initialize, then press .

ASUS TS100-E4/PI2 - Using the Initialize command - 1

text_image Management Menu Configure Initialize Objects Rebuild Check Consistency Initialize Logical Drive(s) Use Cursor Keys To Navigate Between Items And Press Enter To Select On Option
  1. The screen displays the available RAID set(s) and prompts you to select the logical drive to initialize. Use the arrow keys to select the logical drive from the Logical Drive selection, then press .

ASUS TS100-E4/PI2 - Using the Initialize command - 2

text_image Logical Drive(s) Configured Management Menu LD RAID Size HStripes StripeS2 Status Configure Initialize 0 1 114376MB 2 64 KB ONLINE Objects Rebuild Check Consistency Logical Drives Select Logical Drive SPICE-(Doc)Select EIO-Initialize
  1. When prompted, press the to select Yes from the Initialize? dialog box, then press . You may also press to initialize the drive without confirmation.

ASUS TS100-E4/PI2 - Using the Initialize command - 3

text_image Management Menu Configure Initialize Objects Rebuild Check Consistency Logical Drives Initialize Will Destroy Data On Selected Logical Drive(s). SPACE-(De)Select F10-Initialize LD RAID Size #Stripes StripeS2 Status 0 1 114376MB 2 64 KB ONLINE Initialize ?* Yes No

ASUS TS100-E4/PI2 - Using the Initialize command - 4

Initializing a logical drive(s) erases all data on the drive.

  1. A progress bar appears on screen. If desired, press to abort initialization.

ASUS TS100-E4/PI2 - Using the Initialize command - 5

text_image Logical Drive(s) Configured Management Menu LD RAID Size NStripes StripeS2 Status Configure Initial Initialize Logical Drives In Progress ONLINE Objects Rebuild Array Initialization Under Progress. Press ESC to ABORT Check C 16 % Completed Logica SPACE-(Do)Select F10-Initialize
  1. When initialization is completed, press .

ASUS TS100-E4/PI2 - Using the Initialize command - 6

text_image Logical Drive(s) Configured Management Menu -- LD RAID Size NStripes StripeS2 Status Configure Initial Initialize Logical Drives In Progress ONLINE Objects Rebuild Array Initialization Complete !! Press ESC.. Check C- 100% Completed Logica SPACE-(De)Select F10-Initialize

Using the Objects command

To initialize the logical drives using the Objects command:

  1. From the Management Menu, highlight Objects, then press .

ASUS TS100-E4/PI2 - Using the Objects command - 1

text_image Management Menu Configure Initialize Objects Rebuild Check Consistency Configure Objects Like Adapter Parameters Use Cursor Keys To Navigate Between Items And Press Enter to Select On Option
  1. Select Logical Drive from the Objects sub-menu, then press .

ASUS TS100-E4/PI2 - Using the Objects command - 2

text_image Objects Management Adapter Configure Logical Drive Initialize Physical Drive Objects Rebuild Check Consistency Change Logical Drive Parameters Use Cursor Keys To Navigate Between Items And Press Enter To Select On Option
  1. Select the logical drive to initialize from the Logical Drives sub-menu, then press .

ASUS TS100-E4/PI2 - Using the Objects command - 3

text_image Logical Drives(1) Logical Drive 0 Obj Managemen Adapter Configure Logical Drive Initialize Physical Drive Objects Rebuild Check Consistency Select Logical Drive Press ENTER To Select Logical Drive. To Delete Logical Drive Array
  1. Select Initialize from the pop-up menu, then press to start initialization.

ASUS TS100-E4/PI2 - Using the Objects command - 4

text_image Logical Drives(1) Logical Drive 0 Obj Management Adapter Configure Logical Drive Initialize Physical Drive Objects Rebuild Check Consistency Initialize Check Consistency View/Update Parameters Initialize Logical Drive Use Cursor Keys To Navigate Between Items And Press Enter To Select On Option
  1. When prompted, press the to select Yes from the Initialize? dialog box, then press . You may also press to initialize the drive without confirmation.

ASUS TS100-E4/PI2 - Using the Objects command - 5

text_image Logical Drives(1)... Logical Drive 0 Obj Managemen Adapter Configure Logical Drive Initialize Physical Drive Objects Rebuild Logical Drive 0 Check Consistency Initialize Check Con Initialize View/Update Yes No Initialize Will Destroy Data On Selected Logical Drive(s). Use Cursor Keys to Navigate Between Items And Press Enter To Select On Option
  1. A progress bar appears on screen. If desired, press to abort initialization.

ASUS TS100-E4/PI2 - Using the Objects command - 6

text_image Logical Drives(1) Logical Drive 0 Obj Managemen Adapter Configure Logical Drive Initial Initialize Logical Drives In Progress Objects Rebuild Array Initialization Under Progress. Press ESC to ABORT Check C / 23 % Completed Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
  1. When initialization is completed, press .

ASUS TS100-E4/PI2 - Using the Objects command - 7

text_image Logical Drives(1)- Logical Drive 0 Obj Managemen-Adapter Configure Logical Drive Initial Initialize Logical Drives In Progress Objects Rebuild Array Initialization Complete !! Press ESC.. Check C 100% Completed

5.3.4 Rebuilding failed drives

You can manually rebuild failed hard disk drives using the Rebuild or Objects command in the Management Menu.

Using the Rebuild command

To rebuild a failed hard disk drive using the Rebuild command:

  1. From the Management Menu, highlight Rebuild, then press .

ASUS TS100-E4/PI2 - Using the Rebuild command - 1

text_image Management Menu Configure Initialize Objects Rebuild Check Consistency Rebuild Physical Drive(s) Use Cursor Keys To Navigate Between Items And Press Enter To Select On Option
  1. The PHYSICAL DRIVES SELECTION MENU displays the available drives connected to the SATA ports. Select the drive you want to rebuild, then press .

ASUS TS100-E4/PI2 - Using the Rebuild command - 2

text_image Rebuild - PHYSICAL DRIVES SELECTION MENU Management Configure Initialize Objects Rebuild Check Consis PORT # 8-ONLINE 500-00 1-ONLINE 500-00 Port # 0 DISK 114376MB HDS722512VLSA80 V330AGMA- SPACE-(Del)Select E10-Start Rebuild E2-Drive Information E3-View Logical Drives
  1. After selecting the drive to rebuild, press . The indicator for the selected drive now shows RBLD.

  2. When prompted, press to rebuild the drive.

  3. When rebuild is complete, press any key to continue.

Using the Objects command

To rebuild a failed hard disk drive using the Objects command:

  1. From the Management Menu, select Objects, then select Physical Drive from the menu.
  2. Use the arrow keys to select the physical drive you want to rebuild, then press .
  3. Select Rebuild from the pop-up menu, then press .
  4. When prompted, press to rebuild the drive.
  5. When rebuild is complete, press any key to continue.

5.3.5 Checking the drives for data consistency

You can check and verify the accuracy of data redundancy in the selected logical drive. The utility can automatically detect and/or detect and correct any differences in data redundancy depending on the selected option in the Objects > Adapter menu.

ASUS TS100-E4/PI2 - Checking the drives for data consistency - 1

The Check Consistency command is available only for logical drives included in a RAID 1 set.

Using the Check Consistency

To check data consistency using the Check Consistency command:

  1. From the Management Menu, select Check Consistency, then press .

ASUS TS100-E4/PI2 - Using the Check Consistency - 1

text_image Management Menu Configure Initialize Objects Rebuild Check Consistency Check Consistency Of Logical Drive(s) Use Cursor Keys To Navigate Between Items And Press Enter to Select On Option
  1. The screen displays the available RAID set(s) and prompts you to select the logical drive to check. Use the arrow keys to select the logical drive from the Logical Drive selection, then press .

ASUS TS100-E4/PI2 - Using the Check Consistency - 2

text_image Management Menu Configure Initialize Objects Rebuild Check Consistency Logical Drives Select Logical Drive SPACE-(Do)Select. E10-Check Consistency LD RAID Size USStripes StripeS2 Status 0 1 114376MB 2 64 KB ONLINE
  1. When prompted, press the to select Yes from the Consistency Check dialog box, then press . You may also press to check the drive consistency.

ASUS TS100-E4/PI2 - Using the Check Consistency - 3

text_image Logical Drive(s) Configured Management Menu LD RAID Size NStripes StripeSz Status Configure Initialize 0 1 114376MB 2 64 KB ONLINE Objects Rebuild Check Consistency Consistency Check Yes No Logical Drives Select Logical Drive SPACE-(Do)Select. F10-Check Consistency

A progress bar appears on screen.

ASUS TS100-E4/PI2 - Using the Check Consistency - 4

text_image Logical Drive(s) Configured Management Menu -- LD RAID Size HStripes StripeSz Status Configure Initial Consistency Check ONLINE Objects Rebuild Consistency Check Under Progress. Press ESC to ABORT. Check C / 0 % Completed Logica SPACE-(Be)Select... F10-Check Consistency
  1. While checking the disk consistency, press to display the following options.

- Stop - Stops the consistency check. The utility stores the percentage of disk checked. When you restart checking, it continues from the last percentage completed rather than from zero percent.

- Continue - Continues the consistency check.

- Abort - Aborts the consistency check. When you restart checking, it continues from zero percent.

  1. When checking is complete, press any key to continue.

Using the Objects command

To check data consistency using the Objects command:

  1. From the Management Menu, select Objects, then select Logical Drive from the menu.
  2. Use the arrow keys to select the logical drive you want to check, then press .
  3. Select Check Consistency from the pop-up menu, then press .
  4. When prompted, press to check the drive.
  5. When checking is complete, press any key to continue.

5.3.6 Deleting a RAID configuration

To delete a RAID configuration:

  1. From the Management Menu, select Configure > Clear Configuration, then press .

ASUS TS100-E4/PI2 - Deleting a RAID configuration - 1

text_image Configuration Menu Easy Configuration Management Now Configuration Configure View/Add Configuration Initialize Clear Configuration Objects Select Boot Drive Rebuild Check Consistency Clear Existing Configuration Use Cursor Keys To Navigate Between Items And Press Enter To Select On Option
  1. When prompted, press the to select Yes from the Clear Configuration? dialog box, then press .

ASUS TS100-E4/PI2 - Deleting a RAID configuration - 2

text_image Configuration Menu Easy Configuration Management Now Configuration Configure View/ Clear Configuration? Initialize Clear Yes Objects Select No Rebuild Check Consistency Clear Existing Configuration Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option

The utility clears the current array.

  1. Press any key to continue.

5.3.7 Selecting the boot drive from a RAID set

You must have created a new RAID configuration before you can select the boot drive from a RAID set. Refer to the Creating RAID setting Using New Configuration section for details.

To select the boot drive from a RAID set:

  1. From the Management Menu, select Configure > Select Boot Drive, then press .

ASUS TS100-E4/PI2 - Selecting the boot drive from a RAID set - 1

text_image Configuration Menu Easy Configuration Management New Configuration Configure View/Add Configuration Initialize Clear Configuration Objects Select Boot Drive Rebuild Check Consistency Specify A Logical Drive As Boot Drive On This Adapter Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
  1. When prompted, press the to select the bootable logical drive from the list, then press .

ASUS TS100-E4/PI2 - Selecting the boot drive from a RAID set - 2

text_image Bootable Logical Drives (4): Currently (0) Config Boot Drive 0 Easy Co Boot Drive 1 Management New Con Boot Drive 2 Configure View/Ad Boot Drive 3 Initialize Clear C Objects Select Boot Drive Rebuild Check Consistency Specify A Logical Drive As Boot Drive On This Adapter Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
  1. The logical drive is selected as boot drive. Press any key to continue.

5.3.8 Enabling the WriteCache

You may enable the RAID controller's WriteCache option to improve the data transmission performance.

ASUS TS100-E4/PI2 - Enabling the WriteCache - 1

When you enable WriteCache, you may lose data when a power interruption occurs while transmitting or exchanging data among the drives.

To enable WriteCache:

  1. From the Management Menu, select Objects > Adapter, then press to display the adapter properties.

  2. Select WriteCache, then press to turn the option On (enabled).

ASUS TS100-E4/PI2 - To enable WriteCache: - 1

text_image Adapter 0 BoldRate = 80 BiasState = Enable StopOnError = No NewDevice = Auto Configuration FastInit = Enable ChkConState = Report Only Rebuild WriteCache = Off Check Consistency ReadAhead = On Auto Rebuild = On AutoResume = Enable DiskCoercion = 10 GB Factory Default Write Cache Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
  1. When finished, press any key to continue.

5.4 Global Array Manager

You may also create a RAID set(s) in Windows® operating environment using the Global Array Manager (GAM) application. The GAM application is available from the motherboard support CD.

ASUS TS100-E4/PI2 - Global Array Manager - 1

Refer to the GAM user guide in the motherboard support CD for details.

Chapter 6

This chapter provides instructions for installing the necessary drivers for different system components.

ASUS TS100-E4/PI2 - Chapter 6 - 1

natural_image Black desktop computer tower with visible drive bays and ventilation slots (no text or labels)

Driver insatation

6.1 RAID driver installation

After creating the RAID sets for your server system, you are now ready to install an operating system to the independent hard disk drive or bootable array. This part provides instructions on how to install the RAID controller drivers during OS installation.

6.1.1 Creating a RAID driver disk

ASUS TS100-E4/PI2 - Creating a RAID driver disk - 1

You may have to use another system to create the RAID driver disk from the system/motherboard support CD or from the Internet.

A floppy disk with the RAID driver is required when installing Windows® 2000 or Red Hat® Enterprise ver. 3.0/SuSE operating system on a hard disk drive that is included in a RAID set. You can create a RAID driver disk in DOS (using the Makedisk application in the support CD).

To create a RAID driver disk in DOS environment:

  1. Place the motherboard support CD in the optical drive.
  2. Restart the computer, then enter the BIOS Setup.
  3. Select the optical drive as the first boot priority to boot from the support CD. Save your changes, then exit the BIOS Setup.
  4. Restart the computer.
  5. Press any key when prompted to boot from CD.
Loading FreeDOS FAT KERNEL GO!
Press any key to boot from CDROM... 

The Makedisk menu appears.

A) FreeDOS command prompt
B) Make Intel ICH7R LSI MegaRAID for Win32/64 bit driver disk
C) Make Intel ICH7R LSI MegaRAID for RHEL 3 32/64 bit driver disk
D) Make Intel ICH7R LSI MegaRAID for RHEL 4 32/64 bit driver disk
E) Flash AMI BIOS for TS100-E4/PI2
F) Broadcom ASF Firmware Update
G) Write TS100-E4/PI2 FRU
Please choose A To G: 
  1. Place a blank, high-density floppy disk to the floppy disk drive, then select the type of RAID driver disk you want to create by typing the number before the option
  2. Press .
  3. Follow screen instructions to create the driver disk.

6.1.2 Installing the RAID controller driver

Windows® 2003 Server OS

During Windows® 2003 Server OS installation

To install the RAID controller driver when installing Windows 2000/2003 Server OS:

  1. Boot the computer using the Windows® 2003 Server installation CD. The Windows® 2003 Setup starts.

ASUS TS100-E4/PI2 - During Windows® 2003 Server OS installation - 1

text_image Windows 2000 Setup Press F6 if you need to install a third party SCSI or RAID driver...
  1. Press when the message "Press F6 if you need to install a third party SCSI or RAID driver..." appears at the bottom of the screen.
  2. When prompted, press to specify an additional device.

ASUS TS100-E4/PI2 - During Windows® 2003 Server OS installation - 2

text_image Windows 2008 Setup Setup could not determine the type of one or more mass storage devices installed in your system, or you have chosen to manually specify an adapter. Currently, Setup will load support for the following mass storage devices(s): • To specify additional SCSI adapters, CO-ROM drives, or special disk controllers for use with Windows 2008, including those for which you have a device support disk from a mass storage device manufacturer, press S. • If you do not have any device support disks from a mass storage device manufacturer, or do not want to specify additional mass storage devices for use with Windows 2008, press ENTER.
  1. Insert the RAID driver disk you created earlier to the floppy disk drive, then press .

ASUS TS100-E4/PI2 - During Windows® 2003 Server OS installation - 3

text_image Windows 2008 Setup Please insert the disk labeled Manufacturer-supplied hardware support disk into Drive A: * Press ENTER when ready. ENTER=Continue ESC=Cancel FJ=Exit
  1. Select the RAID controller driver from the list, then press .

ASUS TS100-E4/PI2 - During Windows® 2003 Server OS installation - 4

text_image Windows Setup You have chosen to configure a SCSI Adapter for use with Windows, using a device support disk provided by an adapter manufacturer. Select the SCSI Adapter you want from the following list, or press ESC to return to the previous screen. LSI Logic Embedded SATA RAID LSI Logic Embedded SATA RAID (Intel IA32E) ENTER=Select F3=Exit

LSI Logici SATATRAIDAID

Select "LSI Logic Embedded SATA RAID" for 32bit Windows 2003 Server OS from the list, then press . For 64bit Windows 2003 Server OS, please select "LSI Logic Embedded SATA RAID (Intel IA32E)" item.

ASUS TS100-E4/PI2 - LSI Logici SATATRAIDAID - 1

text_image Windows Setup You have chosen to configure a SCSI Adapter for use with Windows. using a device support disk provided by an adapter manufacturer. Select the SCSI Adapter you want from the following list, or press ESC to return to the previous screen. *Intel(R) 82801GR/GH SATA RAID Controller (Desktop ICH7R/DH) * *Intel(R) 82801GR/GH SATA AHCI Controller (Desktop ICH7R/DH) * *Intel(R) 82801FR SATA RAID Controller (Desktop ICH6R) * *Intel(R) 82801FR SATA AHCI Controller (Desktop ICH6R) * *Intel(R) 82801FBM SATA AHCI Controller (Mobile ICH6M) * *Intel(R) 82801FR SATA RAID Controller (Desktop ICH5R) * *Intel(R) 6300ESB SATA RAID Controller ENTER=Select F3=Exit

Intel Matrix Storage

Select "Intel(R) 82801GR/CHSATARRAID Contributor(Desktop:CH7RDH)" for Intel Matrix Storage RAID mode from the list, then press .

If you configured SATA as AHCI Mode in the BIOS setup utility of IDE Configuration, first install the Intel SATA AHCI Driver during windows setup. Then, select the "Intel(R) 82801GRI6H SATA AHCHrController (Desktop ICH7RDH)" from the list. Refer to section "6.1.1 Creating a RAID driver disk" to create the Intel SATA Driver for windows system.

  1. The Windows® 2003 Setup loads the RAID controller drivers from the RAID driver disk. When prompted, press to continue installation.
  2. Setup then proceeds with the OS installation. Follow screen instructions to continue.

To an existing Windows® 2003 Server OS

To install the RAID controller driver on an existing Windows 2003 Server OS:

  1. Restart the computer, then log in with Administrator privileges.
  2. Windows® automatically detects the RAID controller and displays a New Hardware Found window. Click Cancel.
  3. Right-click the My Computer icon on the Windows® desktop, then select Properties from the menu.
  4. Click the Hardware tab then click the Device Manager button to display the list of devices installed in the system.

ASUS TS100-E4/PI2 - To an existing Windows® 2003 Server OS - 1

text_image Computer Management Action View Tree Computer Management (Local) System Tools Event Viewer System Information Performance Logs and Alerts Shared Puffers Device Manager Local Users and Groups Storage Disk Management Disk Defragmenters Logical Drives Removable Storage Services and Applications ASUS-SVRMB Computer Disk drives Display adapters DVD/CD-ROM drives Floppy disk controllers Flappy disk drives IDL ATA/ATAPE controllers Keyboards Mice and other pointing devices Monitors Network adapters Other devices RAID Controller Ports (COM 0.1.P1) SCSI and RADI controllers Sound, video and game controllers System devices Universal Serial Bus controllers
  1. Right-click the RAID controller item, then select Properties.
  2. Click the Driver tab, then click the Update Driver button.
  3. The Upgrade Device Driver Wizard window appears. Click Next.
  4. Insert the RAID driver disk you created earlier to the floppy disk drive.
  5. Select the option "Search for a suitable driver for my device (recommended)", then click Next.

  6. The wizard searches the RAID controller drivers. When found, click Next to install the drivers.

  7. Click Finish after the driver installation is done.

ASUS TS100-E4/PI2 - To an existing Windows® 2003 Server OS - 2

text_image Upgrade Device Driver Wizard Driver Files Search Results The wizard has finished searching for drivers ifes for your hardware device. The wizard found a driver for the following device: PAID Controller Windows found a driver that is a closer match for this device than your current driver. To install the driver Windows found, click Next. d:\drivers\6300\v5\windows\win12\varichinl < Back Next > Cancel

To verify the RAID controller driver installation:

  1. Right-click the My Computer icon on the Windows® desktop, then select Properties from the menu.
  2. Click the Hardware tab, then click the Device Manager button.
  3. Click the “+” sign before the item SCSI and RAID controllers. The LSI Logic Embedded SATA RAID or Intel® 8201 GR/GH SATA RAID items should appear.

ASUS TS100-E4/PI2 - To an existing Windows® 2003 Server OS - 3

text_image Computer Management Tree Computer Management (Local) System Tools Event Viewer System Information Performance Logs and Alerts Shared Posters Device Manager Local Users and Groups Storage Disk Management Disk Defragmenter Logical Drives Renovable Storage Services and Applications Computer Disk drives Display adapters RAGE XL PCI DVD/CD-ROM drives Floppy disk controllers Floppy disk drives IDE ATA/ATAFT controllers Keyboards Mice and other pointing devices Monitors Network adapters Ports (COM & IPT) SCSI and RAID controllers LSI Logic Embedded SATA RAID Sound, Video and game controllers Storage volumes System devices Universal Serial Bus controllers
  1. Right-click the RAID controller driver item, then select Properties from the menu.
  2. Click the Driver tab, then click the Driver Details button to display the RAID controller drivers.
  3. Click OK when finished.

Red Hat® Enterprise ver. 3.0

To install the Intel ^® ICH7R LSI Logic Embedded SATA RAID controller driver when installing Red Hat ^® Enterprise ver. 3.0 operating system:

  1. Boot the system from the Red Hat® Installation CD.

ASUS TS100-E4/PI2 - Red Hat® Enterprise ver. 3.0 - 1

text_image . redhat.

Red Hat Enterprise Linux

ASUS TS100-E4/PI2 - Red Hat® Enterprise ver. 3.0 - 2

text_image - To install or upgrade in graphical node, press the key. - To install or upgrade in text node, type: linux text . - Use the function keys listed below for more information. [F1-Main] [F2-Options] [F3-General] [F4-Kernel] [F5-Rescue] boot: _
  1. At the boot:, type linux dd, then press .

ASUS TS100-E4/PI2 - Red Hat® Enterprise ver. 3.0 - 3

text_image Installer Boot Options - To disable hardware probing, type: linux noprobe . - To test the install media you are using, type: linux mediacheck . - To enable rescue node, type: linux rescue . Press for more information about rescue node. - If you have a driver disk, type: linux dd . - To prompt for the install method being used on a CD-ROM install, type linux askmethod . - If you have an installer update disk, type: linux updates . - To test the memory in your system type: mentestOG . (This option is only available when booting from CD.) (F1-Main) [F2-Options] [F3-General] [F4-Nemell] [F5-Recovery] boot: linux dd_
  1. Select Yes using the key when asked if you have the driver disk. Press

ASUS TS100-E4/PI2 - Red Hat® Enterprise ver. 3.0 - 4

text_image Welcome to Red Hat Enterprise Linux Driver disk Do you have a driver disk? Yes No / between elements | selects | next screen
  1. Select fd0 using the key when asked to select the driver disk source. Press to move the cursor to OK, then press .

ASUS TS100-E4/PI2 - Red Hat® Enterprise ver. 3.0 - 5

text_image Welcome to Red Hat Enterprise Linux Driver Disk Source You have multiple devices which could serve as sources for a driver disk. Which would you like to use? f48 hdc OK Cancel / between elements | selects | next screen
  1. When prompted, insert the Red Hat® Enterprise ver. 3.0 RAID driver disk to the floppy disk drive, select OK, then press .

ASUS TS100-E4/PI2 - Red Hat® Enterprise ver. 3.0 - 6

text_image Welcome to Red Hat Enterprise Linux Insert Driver Disk Insert your driver disk into /dev/fd0 and press "OK" to continue. OK Back / between elements | selects | next screen

The drivers for the RAID controller are installed to the system.

  1. When asked if you will load additional RAID controller drivers, select Yes, then install the additional RAID controller drivers.

ASUS TS100-E4/PI2 - Red Hat® Enterprise ver. 3.0 - 7

text_image Welcome to Red Hat Enterprise Linux More Driver Disks? Do you wish to load any more driver disks? Yes No / between elements | selects | next screen
  1. Follow screen instructions to continue the OS installation.

SuSE Linux

To install the RAID controller driver when installing SuSE Linux OS:

  1. Boot the system from the SuSE Installation CD.
  2. Select Installation from the Boot Options menu, then press .

ASUS TS100-E4/PI2 - SuSE Linux - 1

text_image Boot from Hard Disk Installation Installation - ACPI Disabled Installation - Safe Settings Manual Installation Rescue System Memory Test Boot Options

F1 Help F2 800 x 600 F3 CD-ROM F4 English F5 Silent F6 Driver Update

  1. A message instructs you to prepare the RAID driver disk. Press .

ASUS TS100-E4/PI2 - SuSE Linux - 2

text_image Boot from Hard Disk Installation Installation - ACPT Disabled Installation - Safe Settings Manual Installation Rescue System Memory Test Please get your Driver Update Floppy ready. Boot Options

F1 Help F2 800 x 600 F3 CD-ROM F4 English F5 Silent F6 Driver Update

ASUS TS100-E4/PI2 - SuSE Linux - 3

For SuSE Linux Enterprise Server 9.0 SP1 operating system, do not use OS bundled driver, otherwise your computer may become unstable due to OS limitation.

  1. When prompted, insert the RAID driver disk to the floppy disk drive, then press .

ASUS TS100-E4/PI2 - SuSE Linux - 4

text_image Boot from Hard Disk Installation Boot loader Please insert the driver update floppy/CDROH. OK Memory Test Please get your Driver Update Floppy ready. Boot Options F1 Help F2 800 x 600 F3 CD-ROM F4 English F5 Silent F6 Driver Update
  1. When prompted, select the floppy disk drive (fd0) as the driver update medium, select OK, then press .

ASUS TS100-E4/PI2 - SuSE Linux - 5

text_image >>> Linux or 6 (Kernel 2.6.4-52-default) lc) 1996-2004 SUSE LINUX AG << Please choose the Driver Update medium. fd0 (floppy) hdc (cdrom) other OK Back

The drivers for the RAID controller are installed to the system.

6.2 LAN driver installation

This section provides instructions on how to install the Broadcom ^ Gigabit LAN controller drivers.

6.2.1 Windows® 2003 Server

To install the Broadcom® Gigabit LAN controller driver on a Windows® 2003 Server OS:

  1. Restart the computer, then log on with Administrator privileges.
  2. Insert the motherboard/system support CD to the optical drive. The CD automatically displays the Drivers menu if Autorun is enabled in your computer.

ASUS TS100-E4/PI2 - Windows® 2003 Server - 1

  • Windows ^® automatically detects the LAN controllers and displays a New Hardware Found window. Click Cancel to close this window.
  • If Autorun is NOT enabled in your computer, browse the contents of the support CD to locate the file ASSETUP.EXE from the BIN folder. Double-click the ASSETUP.EXE to run the CD.

  • Click the Broadcom 5721 Driver option to begin installation.

ASUS TS100-E4/PI2 - Windows® 2003 Server - 2

text_image ASUS TS100-E4/PI2 support CD for Windows Server 2003 32 bit Edition Drivers | Management Software | Utilities | Contact | Drivers Please select items on the right side. Intel Chipset Update Utility XGI VOLARI ZI Broadcom 5721 Driver Broadcom 5721 NetXtreme Software Utility
  1. Click Next when the InstallShield Wizard window appears. Follow screen instructions to continue installation.

ASUS TS100-E4/PI2 - Windows® 2003 Server - 3

text_image InstallShield Wizard Welcome to the Broadcom Driver Installer setup application. This application will install the NetChrome Ethernet Device Driver onto your system. < Back Next > Cancel

6.2.2 Red Hat® Enterprise ver. 3.0

Follow these instructions when installing the Broadcom® Gigabit LAN controller base driver for the Red Hat® Enterprise ver. 3.0 operating system.

Building the driver from the TAR file

ASUS TS100-E4/PI2 - Building the driver from the TAR file - 1

Install first the Kernel Development tools before building the driver from the TAR file.

To build the driver from the TAR file:

  1. Create a directory and extract the TAR files: tar xvzf bcm5700-.tar.gz
  2. Build the driver bcm5700.o as a loadable module for the running kernel: cd bcm5700-/src make
  3. Test the driver by loading it: insmod bcm5700.o
  4. Install the driver and man page: make install
  5. Refer to Red Hat distribution documentation to configure the network protocol and address.

6.3 VGA driver installation

This section provides instructions on how to install the XGI Graphics driver.

6.3.1 Windows® 2003 Server

The Windows® 2003 Server operating system automatically recognizes the XGI Graphics driver during system installation. There is no need to install an additional driver(s) to support the onboard VGA.

6.3.2 Red Hat® Enterprise ver. 3.0

The Red Hat® Enterprise ver. 3.0 operating system automatically recognizes the XGI Graphics driver during system installation. There is no need to install an additional driver(s) to support the onboard VGA.

6.4 Management applications and utilities installation

The support CD that came with the motherboard package contains the drivers, management applications, and utilities that you can install to avail all motherboard features.

ASUS TS100-E4/PI2 - Management applications and utilities installation - 1

The contents of the support CD are subject to change at any time without notice. Visit the ASUS website (www.asus.com) for updates.

6.4.1 Running the support CD

Place the support CD to the optical drive. The CD automatically displays the Drivers menu if Autorun is enabled in your computer.

ASUS TS100-E4/PI2 - Running the support CD - 1

If Autorun is NOT enabled in your computer, browse the contents of the support CD to locate the file ASSETUP.EXE from the BIN folder. Double-click the ASSETUP.EXE to run the CD.

6.4.2 Drivers menu

The Drivers menu shows the available device drivers if the system detects installed devices. Install the necessary drivers to activate the devices.

ASUS TS100-E4/PI2 - Drivers menu - 1

The screen display and driver options vary under different operating system versions.

ASUS TS100-E4/PI2 - Drivers menu - 2

text_image ASUS TS100-E4/PI2 support CD for Windows Server 2003 32 bit Edition Drivers | Management Software | Utilities | Contact | Drivers Please select items on the right side. Intel Chipset Update Utility XGI VOLARI Z7 Broadcom 5721 Driver Broadcom 5721 NetXtreme Software Utility

6.4.3 Management Software menu

The Management Software menu displays the available network and server monitoring application. Click on an item to install.

ASUS TS100-E4/PI2 - Management Software menu - 1

text_image ASUS TS108-E4/PI2 support CD for Windows Server 2003 - 32 bit Edition Drivers Management Software Options Contact Management Software Please select items on the right side ASUS Remote Console Install Asus Network Utility ASWM

6.4.4 Utilities menu

The Utilities menu displays the software applications

ASUS TS100-E4/PI2 - Utilities menu - 1

text_image ASUS TS104-E4/PI2 support CD for Windows Server 2003 32 bit Edition Drivers | Management Software | Utilities | Contact | Utilities Please select items on the right side. ADOBE Acrobat Reader V7.0 ASUS Screen Saver Broadcom ASF Installer Broadcom ASF Guide ASUS Update

6.4.5 Contact information

Click the Contact tab to display the ASUS contact

ASUS TS100-E4/PI2 - Contact information - 1

text_image ASUS TS100-E4/PI2 support CD for Windows Server 2003 32 bit Edition Drivers | Management Software | Utilities | Contact Contact ASUSTEK COMPUTER INC. (Asia Pacific) Marketing Address: US, U.Tx Road, Petou, Teles, Taiwan 112 Telephone: 000-2-2004-2447 Fax: +69-2-2004-2449 E-mail: https://asus.com.tw Technical Support Telephone: 000-2-2000-7121 (MB) +885-2-2000-7123 (Server) E-mail: http://asp.asus.com/service/techserv.aspx http://www.asus.com ASUS COMPUTER INTERNATIONAL (America) Marketing Address: NASC/Casim Drive, Fremont, CA 24588 USA Fax: +1-510-400-055 E-mail: http://asus.com/ RMA Support Telephone: +1-502-993-0003 Fax: +1-502-933-8713 E-mail: http://asp.asus.com/ eyservice/techerv.aspx http://www.asus.com ASUS COMPUTER GmbH (Germany & Austria) Marketing Address: Harlort Str. 25, D-40880 Ratingm, Germany Telephone: +9-2102-9599-9 Fax: +9-2102-9599-11 Online Contact: http://www.asus.com/details Technical Support Telephone: +9-2102-9599-0 Fax: +9-2102-9599-11 Online Contact: http://www.asus.com/dissupport Download: http://www.asus.com/details http://www.asus.com DR ASUS COMPUTER INTERNATIONAL (America)

Appendix

The Appendix describes the CPU features that the motherboard supports.

ASUS TS100-E4/PI2 - Appendix - 1

natural_image Black desktop computer tower with visible drive bays and ventilation slots (no text or labels)

Refere info

A.1 Intel® EM64T

ASUS TS100-E4/PI2 - A.1 Intel® EM64T - 1

  • The motherboard is fully compatible with Intel ^ Pentium ^ 4 LGA775 processors running on 32-bit operating systems.
  • The motherboard comes with a BIOS file that supports EM64T. You can download the latest BIOS file from the ASUS website (www.asus.com/support/download/) if you need to update the BIOS file. See Chapter 5 for details.
  • Visit www.intel.com for more information on the EM64T feature.
  • Visit www.microsoft.com for more information on Windows® 64-bit OS.

Using the Intel® EM64T feature

To use the Intel ^® EM64T feature:

  1. Install an Intel ^® Pentium ^® 4 CPU that supports the Intel ^® EM64T.
  2. Install a 64-bit operating system (Windows® XP Professional x64 Edition).
  3. Install the 64-bit drivers for the motherboard components and devices from the support CD.
  4. Install the 64-bit drivers for expansion cards or add-on devices, if any.

ASUS TS100-E4/PI2 - Using the Intel® EM64T feature - 1

Refer to the expansion card or add-on device(s) documentation, or visit the related website, to verify if the card/device supports a 64-bit system.

A.2 Enhanced Intel SpeedStep Technology (EIST)

ASUS TS100-E4/PI2 - A.2 Enhanced Intel SpeedStep Technology (EIST) - 1

  • The motherboard comes with a BIOS file that supports EIST. You can download the latest BIOS file from the ASUS website (www.asus.com/support/download/) if you need to update the BIOS. See Chapter 5 for details.
  • Visit www.intel.com for more information on the EIST feature.

A.2.1 System requirements

Before using EIST, check your system if it meets the following requirements:

  • Intel ^ Pentium ^ 4 processor with EIST support
    • BIOS file with EIST support
  • Operating system with EIST support (Windows ^ XP SP2/Linux 2.6 kernel or later versions)

A.2.2 Using the EIST

To use the EIST feature:

  1. Turn on the computer, then enter the BIOS Setup.
  2. Go to the Advanced Menu, highlight CPU Configuration, then press .

  3. Set the Intel(R) SpeedStep Technology item to [Automatic], then press . See page 5-24 for details.

  4. Press to save your changes and exit the BIOS setup.

  5. After the computer restarts, right click on a blank space on the desktop, then select Properties from the pop-up menu.

  6. When the Display Properties window appears, click the Screen Saver tab.

  7. Click the Power button on the Monitor power section to open the Power Options Properties window.

ASUS TS100-E4/PI2 - A.2.2 Using the EIST - 1

text_image Display Properties Themes Desktop Screen Save Appearance Settings Screen save Name Settings Programm To adjust monitor power settings and save energy click Power. Power... OK Cancel Apply
  1. On the Power schemes section, click ▼, then select any option except Home/Office Desktop or Always On.

  2. Click Apply, then click OK.

  3. Close the Display Properties window.

After you adjust the power scheme, the CPU internal frequency slightly decreases when the CPU loading is low.

ASUS TS100-E4/PI2 - A.2.2 Using the EIST - 2

text_image Power Options Properties Power Schemes Advanced UPS Select the power scheme with the most appropriate settings for this compute. Note that changing the settings below will modify the selected scheme. Power schemes Always On Home/Office Desk Portable/Backup Presentation Always On Minimal Power Management New Rates I am off monitor: After 20 mins I am off hard disks: None OK Cancel Apply

ASUS TS100-E4/PI2 - A.2.2 Using the EIST - 3

The screen displays and procedures may vary depending on the operating system.

A.3 Block diagram

ASUS TS100-E4/PI2 - A.3 Block diagram - 1

flowchart
graph TD
    A["Xeon 3000/3200 Presler"] -->|1066 FSB| B["3000 MCH Mukilteo-2"]
    B -->|x8| C["PCIE2"]
    B -->|x4| D["PCIE1"]
    B -->|DMI Interface| E["ICH7R"]
    E -->|4 x SATA2| F["BCM 5721"]
    E -->|x1| G["XGI Z7"]
    E --> H["PCI 33"]
    H --> I["PCIE1"]

A.4 670 W single power supply

A.4.1 General description

The 250W single power supply with ATX-compliant output cables and connectors. The power supply has 8 plugs labeled P1 to P8. Take note of the devices to which you should connect the plugs.

ASUS TS100-E4/PI2 - A.4.1 General description - 1

text_image P7 P6 P5 P4 P3 P2 P1 P8

P1 Motherboard 24-pin ATX power connector

P2 Motherboard 4-pin +12V power connector

P3 Peripheral device (available); Optical drive

P4 Peripheral device (available); Optical drive

P5 Peripheral device (available); HDD

P6 Peripheral device (available); HDD

P7 Floppy disk drive

P8 SATA power connector

ASUS TS100-E4/PI2 - A.4.1 General description - 2

The voltage switch selection must be the same with voltage of AC Power. Fail to do it will cause PSU damage.

A.4.2 Specifications

Input Characteristics

Input Voltage Range

115V\~/6A or 230V\~/3A, (By Voltage Switch selection)

Input Frequency Range

50 Hz to 60 Hz

DC Output characteristics

Output Voltage Max (A)
+3.3V 16A
+5V 18A
+12V1 10A
+12V2 14A
-12V 0.3A
+5VSB 2.5A

+5V&3.3V Max 115W

+12V1&+12V2 Max 235W

Total Combine Current on 12V1&+12V2 rails are 19A Max

Table of contents Click a title to access it
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : ASUS

Model : TS100-E4/PI2

Category : Server