| Product Type | LED Controller (Constant Current) |
| Model | ELG-150-C1050DA |
| Brand | Mean Well |
| Rated Power | 150 W |
| Output Current | 1050 mA (constant current) |
| Output Voltage Range | 72 ~ 143 V |
| Input Voltage | 100 ~ 277 VAC (autoswitching) |
| Dimming Interface | DALI (Digital Addressable Lighting Interface) |
| Dimensions (L x W x H) | 229 x 63 x 38.8 mm (9.0 x 2.5 x 1.5 in) |
| Weight | 1.2 kg (2.65 lbs) |
| Protection Rating | IP65 (dust-tight and protected against water jets) |
| Operating Temperature | -40°C ~ +70°C (with derating) |
| Cooling | Convection (fanless) |
| Safety Standards | UL, ENEC, CE, CB certified |
| Main Functions | Constant current output, DALI dimming, short circuit/overload/overvoltage/over temperature protection |
| Maintenance & Cleaning | Disconnect power before cleaning; use dry cloth; no water ingress; keep ventilation clear |
| Spare Parts & Repairability | Mean Well provides replacement units; no user-serviceable parts inside; contact authorized service center |
| General Information | Designed for LED lighting applications; high efficiency (up to 93%); 5-year warranty |
Frequently Asked Questions - ELG-150-C1050DA Mean Well
How do I wire the ELG-150-C1050DA?
Connect AC input to L and N terminals. For DALI dimming, connect DALI+ and DALI- to the controller. Output terminals are V+ and V- for the LED load. Ensure polarity matches.
What is the output current range?
The ELG-150-C1050DA provides a constant current of 1050 mA. The output voltage automatically adjusts between 72V and 143V to maintain this current.
Can I use this with a 0-10V dimmer?
No, the DA suffix indicates DALI dimming. It is not compatible with 0-10V dimmers. Use a DALI controller instead.
What happens if there is a short circuit?
The driver features short circuit protection. It will shut down and automatically recover once the fault is removed.
Is the driver suitable for outdoor use?
Yes, the IP65 rating makes it dust-tight and protected against water jets, suitable for outdoor or damp locations.
What is the maximum LED load?
The maximum load is 150W. Ensure the total LED wattage does not exceed 150W, and the forward voltage is within 72-143V.
How do I adjust the output current?
The ELG-150-C1050DA is a fixed constant current model. Output current is factory set to 1050 mA and cannot be adjusted externally.
Does it come with a warranty?
Mean Well offers a 5-year warranty from the date of purchase, subject to normal use and conditions.
Can multiple drivers be connected to one DALI line?
Yes, DALI allows multiple drivers on a single bus. Each driver has a unique address. The bus can support up to 64 devices.
What is the efficiency at full load?
The typical efficiency is 93% at full load, reducing energy loss and heat generation.