MT195A-T1 - Wi-Fi repeater Black Box - Free user manual and instructions
Find the device manual for free MT195A-T1 Black Box in PDF.
| Product Type | T1/E1 Link Extender |
| Model | MT195A-T1 |
| Data Rate | 1.544 Mbps (T1) |
| Line Coding | TC-PAM (Trellis Coded Pulse Amplitude Modulation) |
| Circuit Interface | RJ-48C (T1, 100 Ohms) |
| Line Connection | RJ-45, single twisted pair (pins 4 and 5) |
| Power Supply | External AC adapter, 100–240 VAC input, 5 VDC output, 2A |
| Rated Voltage | 5 VDC |
| Rated Current | 1 A DC |
| LED Indicators | Power (on/off), Link (solid/flashing/off), Frame (solid/flashing/off) |
| Operating Temperature | 32–122°F (0–50°C) |
| Humidity | 5–95% non-condensing |
| Altitude | 0–15,000 ft (0–4,572 m) |
| Compliance | FCC Part 15 Class A, EN55022 Class A, EN55024, UL 60950-1, CSA C22.2 No. 60950-1, IEC/EN60950-1, AS/NZS 60950-1, FCC Part 68, CS03, TBR12 & 13 |
| Features | Plug 'n' Play, no configuration required, CE marked, DIP switches for Line Build Out |
| Installation | Connect power, line port, and T1/E1 circuit; no user settings needed |
| Warranty | Contact Black Box Tech Support for repair/warranty |
Frequently Asked Questions - MT195A-T1 Black Box
User questions about MT195A-T1 Black Box
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Wi-Fi repeater in PDF format for free! Find your manual MT195A-T1 - Black Box and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. MT195A-T1 by Black Box.
USER MANUAL MT195A-T1 Black Box
T1/E1 Link Extenders


Important
This is a Class A device and is intended for use in a light industrial environment. It is not intended nor approved for use in an industrial or residential environment.
CE NOTICE
We certify that the apparatus identified in this document conforms to the requirements of Council Directive 1999/5/EC on the approximation of the laws of the member states relating to Radio and Telecommunication Terminal Equipment and the mutual recognition of their conformity.
RADIO AND TV INTERFERENCE
This equipment generates and uses radio frequency energy, and if not installed and used properly—that is, in strict accordance with the manufacturer's instructions—may cause interference to radio and television reception. This equipment has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart B of Part 15 of FCC rules, which are designed to provide reasonable protection from such interference in a commercial installation. However, there is no guarantee that interference will not occur in a particular installation. If the equipment causes interference to radio or television reception, which can be determined by disconnecting the cables, try to correct the interference by one or more of the following measures: moving the computing equipment away from the receiver, re-orienting the receiving antenna, and/or plugging the receiving equipment into a different AC outlet (such that the computing equipment and receiver are on different branches).
FCC PART 68
This equipment complies with Part 68 of FCC rules and the requirements adopted by ACTA. On the bottom side of this equipment is a label that contains—among other information—a product identifier in the format US: AAAEQ##TXXXX. If requested, this number must be provided to the telephone company.
The method used to connect this equipment to the premises wiring and telephone network must comply with the applicable FCC Part 68 rules and requirements adopted by the ACTA.
If this equipment causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. But if advance notice isn't practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary.
The telephone company may make changes in its facilities, equipment, operations or procedures that could affect the operation of the equipment. If this happens the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service.
If trouble is experienced with this equipment, for repair or warranty information, please contact our company. If the equipment is causing harm to the telephone network, the telephone company may request that you disconnect the equipment until the problem is resolved.
Connection to party line service is subject to state tariffs. Contact the state public utility commission, public service commission or corporation commission for information.
INDUSTRY CANADA NOTICE
This equipment meets the applicable Industry Canada Terminal Equipment Technical Specifications. This is confirmed by the registration number. The abbreviation, IC, before the registration number signifies that registration was performed based on a Declaration of Conformity indicating that Industry Canada technical specifications were met. It does not imply that Industry Canada approved the equipment.
This Declaration of Conformity means that the equipment meets certain telecommunications network protective, operational and safety requirements. The Department does not guarantee the equipment will operate to the user's satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. In some cases, the company's inside wiring associated with a single line individual service may be extended by means of a certified connector assembly (telephone extension cord). The customer should be aware that compliance with the above condition may not prevent degradation of service in some situations. Repairs to some certified equipment should be made by an authorized maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment. Users should ensure for their own protection that the ground connections of the power utility, telephone lines and internal metallic water pipe system, are connected together. This protection may be particularly important in rural areas.
COMPLIANCE
EMC
• FCC Part 15, Class A
• EN55022, Class A
• EN55024
SAFETY
• UL 60950-1/CSA C22.2 N0. 60950-1
- IEC/EN60950-1
• AS/NZS 60950-1
PSTN REGULATORY
- FCC Part 68
- CS03
- TBR12 & 13
• AS/ACIF S016:2001
• AS/ACIF S043:2003
SAFETY WHEN WORKING WITH ELECTRICITY

- This device contains no user serviceable parts. The equipment shall be returned to Black Box for repairs, or repaired by qualified service personnel.
- The external AC adaptor shall be a listed limited power source that incorporates a disconnect device and shall be positioned within easy reach of the operator. Ensure that the AC power cable meets all applicable standards for the country in which it is to be installed, and that it is connected to a wall outlet which has earth ground.
- Do not work on the system or connect or disconnect cables during periods of lightning activity.

In accordance with the requirements of council directive 2002/96/EC on Waste of Electrical and Electronic Equipment (WEEE), ensure that at end-of-life you separate this product from other waste and scrap and deliver to the WEEE collection system in your country for recycling.
TRADEMARKS USED IN THIS MANUAL
All applied-for and registered trademarks are the property of their respective owners.
CONTENTS
CE Notice 2
Radio and TV Interference....2
FCC Part 68....2
Industry Canada Notice.... 3
Compliance....4
Safety When Working With Electricity 5
Trademarks Used In This Manual.... 5
- General Information 8
1.1 Features ....8
1.2 Description 8
- Installation.... 9
2.1 Connecting Power 10
2.2 Power Input Connector.... 10
2.2.1 External AC universal power supply ....10
2.3 Connecting the Line Port.... 11
2.4 Connecting the Circuit Interface 11
- Operation.... 12
3.1 Front Panel LED Status Monitors 12
3.2 Configuration and Dip Switches 13
3.2.1 Switch S1-7: Line Build Out 13
A. Specifications 14
A.1 Circuit Rates ....14
A.2 Circuit Interface 14
A.3 Circuit Defaults ....14
A.4 Circuit Connector 14
A.5 LED Indicators 14
A.6 Power and Power Supply Specifications ....14
A.7 Environmental 15
A.8 Transmission Line 15
A.9 Line Coding 15
A.10 Line Interface ....15
A.11 Line Physical Connection ....15
B. Factory Default Dip Switch Configuration 16
B.1 Switch S1 - Factory Default configuration ....16
B.2 Switch S2 - Factory Default Configuration .....16
1. General Information
Thank you for your purchase of this Black Box product. If any questions arise during installation or use of the unit, contact Black Box Tech Support at (724) 746-5500.
1.1 Features
- Easy-to-install T1/E1 Extenders—no configuration required
• Data rates up to 2.048 Mbps in 64-kbps intervals - Plug ‘n’ Play for easy installations
• LED indicators for Power, Ethernet Link, and Frame - CE marked
1.2 Description
The Black Box T1/E1 Extenders provide high speed 2-wire T1/E1 extension connectivity to ISPs, PTTs, and enterprise environments using binder group friendly TC-PAM modulation.
Line connection is made with an RJ-45 jack. Models MT196A-E1 and MT195A-T1 are powered by an 100/230 VAC (Universal) supply. The NTU features externally-accessible DIP switches, loopback diagnostics, and Plug 'n' Play.
2. Installation
Because the T1/E1 Extenders require no configuration, they can be installed quickly. Installation consists of the following:
- Connect the power plug (refer to section 2.1, “Connecting Power” on page 10).
- Connect the line port (refer to section 2.3, “Connecting the Line Port” on page 11)
Note See Figure 1 and Figure 2 for the rear-panel connectors locations.
- Connect the T1/E1 port (refer to section 2.4, “Connecting the Circuit Interface” on page 11).

Figure 1. Model MT196A-E1 rear panel

Figure 2. Model MT195A-T1 rear panel
2.1 Connecting Power

The external AC adaptor shall be a listed limited power source that incorporates a disconnect device and shall be positioned within easy reach of the operator. Ensure that the AC power cable meets all applicable standards for the country in which it is to be installed, and that it is connected to a wall outlet which has earth ground.
Your T1/E1 Extender comes with an external AC adaptor with a detachable power cord.
To connect power to the T1/E1 Extender:
- Connect the female plug of the AC power cord to the AC adaptor provided.
- Connect the barrel-type connector of the AC adaptor to the Power connector on the T1/E1 Extender.
- Insert the male plug of the AC power cord into the AC power outlet (100-240 VAC).
- Verify that the Power LED on the front panel illuminates and remains lit.
2.2 Power Input Connector
The T1/E1 Extender comes with an AC power supply.
- The supplies connection to the T1/E1 Extender is a 2.5 mm barrel receptacle with the center conductor positive (see Figure 3).

Figure 3. Power connection barrel receptacle diagram
• T1/E1 Extender's rated voltage: 5.0 VDC
• T1/E1 Extender's rated current: 1 A DC
2.2.1 EXTERNAL AC UNIVERSAL POWER SUPPLY
• Output from power supply: 5 VDC, 2A
- Input to power supply: universal input 100–240 VAC 50/60 Hz 0.3A
2.3 Connecting the Line Port

CAUTION
The interconnecting cables shall be acceptable for external use and shall be rated for the proper application with respect to voltage, current, anticipated temperature, flammability, and mechanical serviceability.
Follow the steps below to connect the line port:
- Obtain a single-twisted pair cable with an RJ-45 plug connector at each end.
- Plug one end of the cable into the RJ-45 socket (labeled Line) on the T1/E1 Extender.
- When the remote and local extender units synchronize, the front-panel Link LED will turn on.
2.4 Connecting the Circuit Interface
Your T1/E1 Extender comes with either an RJ-48C or an RJ-48C and dual BNC for connection to a T1 or E1:
- Model MT196A-E1 - E1: 120-Ohm RJ-48C and dual 75-Ohm BNC connectors
• Model MT195A-T1 - T1: RJ-48C
To connect the twisted pair cable to the T1/E1 port:
- Attach the male connector of the twisted pair cable to the female RJ-48 connector on the T1/E1 Extender.
- Attach the other end of the cable to the RJ-48 connector on the local T1 or E1.
Note When attaching the T1/E1 Extender directly to a T1/E1 circuit, a straight through twisted pair cable can be used. When attaching the MT196A-E1/R or MT195A-T1/R to a device, please use the enclosed T1/E1 cross over cable for proper operation.
Note The unit marked as MT196A-E1/L or MT195A-T1/L is configured by default to accept timing from the T1/E1 circuit. The MT196A-E1/R or MT195A-T1/R unit then recovers this timing from the line in order to ensure synchronization of the T1/E1 circuit over the extenders.
3. Operation
Once the T1/E1 Extenders are properly installed, they should operate transparently. No user settings required. This section describes reading the LED status monitors.
3.1 Front Panel LED Status Monitors
Models MT196A-E1 and MT195A-T1 feature three front-panel LEDs that monitor power, Ethernet signals, and the CopperLink connection. Figure 4 shows the front panel location of each LED. Table 1 describes the LED functions.

Figure 4. T1/E1 Extender front panel
Table 1: Front panel LED description
| LED Description | |
| Power When lit, indicates the unit is powered on | |
| Link On solid—link is connectedOff—No signal detectedFlashing — Data is being transmitted/received | |
| Frame On solid—T1/E1 frame is connectedOff — No signal detectedFlashing — Error detected |
3.2 Configuration and Dip Switches
The T1/E1 Extenders are Plug ‘n’ Play enabled and do not require any configuration by the user.
Note The user should NOT change any of the dip switches except for S1-7 (if necessary). If the user changes the position of any of the dip switches (except for S1-7), it will affect the operation of the unit. Refer to Appendix B. on page 16 for the factory default dip switch configuration.
3.2.1 SWITCH S1-7: LINE BUILD OUT
Switch S1-7 defines the shape of the waveform on the T1 or E1 line.
Table 2:S1-7 Default Position
| Switch | MT196A-E1/L/EUI | MT196A-E1/R/EUI | MT195A-T1/L/EUI | MT195A-T1/R/EUI |
| S1-7 OFF (120) OFF (120) ON (0.0dB) ON (0.0dB) | ||||
A. Specifications
A.1 Circuit Rates
• Model MT196A-E1 - 2.048 Mbps
• Model MT195A-T1 - 1.544 Mbps
A.2 Circuit Interface
- E1 (Model MT196A-E1) presents G.703/G.704 interface. Either 75 Ohms (unbalanced) or 120 Ohms (balanced). Pins 1 & 2 are Receive. Pins 4 & 5 are transmit.
- T1 (Model MT195A-T1) present T1 interface. Pins 1 & 2 are Receive. Pins 4 & 5 are Transmit.
A.3 Circuit Defaults
• E1 Line Coding = HDB3.
- T1 Line Coding = B8ZS; Line Build Out Rx = Automatic; Line Build Out Tx = 0.
A.4 Circuit Connector
- Dual BNC and RJ48C (Model MT196A-E1), strap selectable
• RJ48C connector (Model MT195A-T1)
A.5 LED Indicators
- Three LED indicators: Power, Link, Frame
A.6 Power and Power Supply Specifications
- AC power supply
- Connection to the T1/E1 Extender requires +5VDC ±5% DC power (1.0A minimum). Center pin is +5V. The barrel type plug has a 2.5/5.5/10mm I.D./O.D./shaft length dimensions
• T1/E1 Extender's rated voltage: 5.0 VDC
• T1/E1 Extender's rated current: 1A DC
A.7 Environmental
• Temperature: 32–122°F (0–50°C)
- Relative Humidity: 5–95%, non-condensing
- Altitude: 0–15,000 ft (0–4,572 m)
A.8 Transmission Line
- Single Twisted Pair
A.9 Line Coding
• TC-PAM (Trellis Coded Pulse Amplitude Modulation)
A.10 Line Interface
• Transformer coupled, 2500 VRMS isolation
A.11 Line Physical Connection
- RJ-45, 2-wire polarity insensitive pins 4 and 5
B. Factory Default Dip Switch Configuration
Note This information is provided for informational purposes only. These settings should not be changed other than by instructions from Black Box Support, lest the unit be rendered inoperable.
B.1 Switch S1 - Factory Default configuration
Table 3: S1 Factory Default Dip Switch Configuration
| Switch | MT196A-E1/L/EUI | MT196A-E1/R/EUI | MT195A-T1/L/EUI | MT195A-T1/R/EUI |
| Switch 1-1 ON ON ON ON | ||||
| Switch 1-2 ON ON ON ON | ||||
| Switch 1-3 ON ON ON ON | ||||
| Switch 1-4 ON ON OFF OFF | ||||
| Switch 1-5 ON ON OFF OFF | ||||
| Switch 1-6 OFF OFF ON ON | ||||
| Switch 1-7 OFF OFF ON ON | ||||
| Switch 1-8 ON ON ON ON |
B.2 Switch S2 - Factory Default Configuration
Table 4: S2 Factory Default Dip Switch Configuration
| Switch | MT196A-E1/L/EUI | MT196A-E1/R/EUI | MT195A-T1/L/EUI | MT195A-T1/R/EUI |
| Switch 2-1 | OFF OFF OFF | OFF | ||
| Switch 2-2 | OFF OFF OFF | OFF | ||
| Switch 2-3 | OFF OFF OFF | OFF | ||
| Switch 2-4 | OFF ON OFF ON | |||
| Switch 2-5 | ON OFF ON OFF | |||
| Switch 2-6 | OFF OFF ON ON | |||
| Switch 2-7 | OFF OFF ON ON | |||
| Switch 2-8 | ON ON ON ON |
Notes
Notes
Notes