HP PROLIANT BL20P G2 SERVER - Server

PROLIANT BL20P G2 SERVER - Server HP - Free user manual and instructions

Find the device manual for free PROLIANT BL20P G2 SERVER HP in PDF.

📄 204 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice HP PROLIANT BL20P G2 SERVER - page 3
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Blade server for HP BladeSystem enclosure
Brand and Model HP ProLiant BL20p G2
Dimensions (H x W x D) Approximately 1.75 x 6.5 x 17.5 inches (4.4 x 16.5 x 44.5 cm)
Weight Approximately 5.5 kg (12 lb)
Power Supply Hot-plug power supply, up to 2 possible
Processor Intel Xeon (dual-core or single-core depending on version)
Memory (RAM) Up to 8 GB DDR2 ECC (4 slots)
Storage 2 bays for hot-plug SAS/SATA hard drives (2.5 inch)
Network 2 integrated Gigabit Ethernet ports
Connectors Serial port, VGA port, USB ports (front and rear)
Remote Management Integrated via HP Integrated Lights-Out (iLO)
Supported Operating Systems Microsoft Windows Server, Linux (Red Hat, SUSE), VMware ESX
Operating Temperature 10 to 35 °C (50 to 95 °F)
Operating Humidity 20% to 80% (non-condensing)
Maintenance and Cleaning Unplug before cleaning; use a dry, antistatic cloth
Safety Follow high-voltage safety guidelines; service by qualified personnel only
Spare Parts and Repairability Spare parts available via HP; module-level repairs only
General Information Blade server designed for virtualized enterprise environments

Frequently Asked Questions - PROLIANT BL20P G2 SERVER HP

How to install the HP ProLiant BL20p G2 server in a rack?
The BL20p G2 is a blade server designed to be installed in an HP BladeSystem enclosure (c7000 or c3000). Insert it into a free slot until it clicks. Ensure that the rails are aligned and the latch is properly in place. For added safety, follow bottom-loading guidelines and remove only one component at a time.
What is the typical power consumption of the HP ProLiant BL20p G2?
Consumption depends on configuration, but typically ranges from 200 to 400 watts per blade. Use appropriate hot-plug power supplies and do not exceed 80% of the power circuit load.
How to replace a hot-plug hard drive on the BL20p G2?
The server supports hot-plug SAS/SATA hard drives. To replace a drive, disconnect it by pulling the latch, insert the new drive until it clicks. No power down is required if the system is configured in RAID.
What to do if a red warning light is lit on the server?
A red light indicates a critical fault. Check the system log via iLO or the enclosure management panel. Possible causes include overheating, power failure, or a failed disk. Follow troubleshooting procedures in the documentation.
How to reset the default iLO password?
The default password for iLO is often printed on a label affixed to the server. Alternatively, you can reset it by removing the CMOS battery or using the iLO reset jumper on the motherboard. Consult the manual for the exact location.
What safety precautions should be taken before opening the server cover?
Before opening the cover, always power down the server by disconnecting all power cords. Wait for the server to cool down. Remove all metal jewelry and use an antistatic wrist strap. Only qualified personnel should service internal circuits.
Does the HP ProLiant BL20p G2 server support virtualization?
Yes, this model supports hypervisors such as VMware ESX, Microsoft Hyper-V, and Linux solutions (KVM, Xen). It is ideal for light virtualized environments. Check processor compatibility with virtualization features (Intel VT).
How to clean the server without damaging it?
Use a soft, lint-free cloth lightly dampened with water or an antistatic cleaner. Never spray liquid directly onto components. Ensure the server is unplugged and cool before cleaning the ventilation grilles.
Where can I find drivers and firmware for the BL20p G2?
Drivers and firmware are available on the HP support website (support.hp.com). Search for your exact model. You can also use the HP Smart Update Manager (SUM) tool for automated updates.
What is the typical lifespan of a CMOS battery on this server?
The CMOS battery (CR2032) typically lasts 3 to 5 years. If the system clock resets or configuration errors appear at startup, it's time to replace it. Disconnect power before replacing the battery.

User questions about PROLIANT BL20P G2 SERVER HP

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Server in PDF format for free! Find your manual PROLIANT BL20P G2 SERVER - HP and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. PROLIANT BL20P G2 SERVER by HP.

USER MANUAL PROLIANT BL20P G2 SERVER HP

Important Safety Information

For Server, Storage, Power, Networking, and Rack Products Read Before Installing Product

Important Safety Information, Read Before Installing Product (English) 1-1 (2) (204) Informações importantes sobre segurança. Leia antes de instalar o produto (Português) 3-1 Važne sigurnosne informacije. Pročitajte prije instalacije proizvoda (Hrvatski) 4-1 Důležité bezpečnostní informace, čtěte před instalací produktu (Čeština) 5-1 Vigtige oplysninger om sikkerhed. Læs dette, inden du installerer produktet (Dansk) 6-1 Belangrijke veiligheidsinformatie, lees dit voordat u het product installeert (Nederlands) 7-1 Tärkeitä turvallisuutta koskevia tietoja, lue ennen tuotteen asentamista (Suomi) 8-1 Tähtis ohutusteave. Lugege enne toote paigaldamist (Eesti) 9-1 Consignes strictes de sécurité, à lire avant toute manipulation et installation du produit (Français) 10-1 Wichtige Sicherheitshinweise, bitte vor der Installation des Produkts sorgfältig lesen (Deutsch) 11-1 Σημαντικές πληροφορίες ασφαλείας. Διαβάστε πριν την εγκατάσταση του προϊόντος (Ελληνικά) 12-1 中京安京通,. (1) 14-1 Fontos tudnivalók a biztonsággal kapcsolatban. Olvassa el a termék üzembe helyezése előtt (Magyar) 15-1 Importanti informazioni sulla sicurezza, da leggersi prima di installare il prodotto (Italiano) 16-1 安全使用のため、製品をインストールする前にお読みください。17-1 Información de Seguridad Importante. Léase antes de Instalar el Producto (Español de Latinoamérica) 18-1 Svarīga informācija par drošību. Izlasiet pirms ierīces uzstādīšanas (Latviešu valoda) 19-1 Svarbi saugos informacija. Perskaitykite prieš montuodami įrangą (Lietuviškai) 20-1 Viktig sikkerhetsinformasjon, les dette før produktet installeres (Norsk) 21-1 Ważne informacje dotyczące bezpieczeństwa, przeczytaj przed rozpoczęciem instalowania produktu (Polski) 22-1 Informações de Segurança Importantes, Leia Antes de Instalar o Produto (Português) 23-1 Важные инструкции по безопасности, ознакомьтесь перед установкой изделия (Русский) 24-1 安全性重要信息,安装产品前先行阅读(简体中文) 25-1 Dôležité bezpečnostné informácie, čítajte pred inštaláciou výrobku (Slovenčina) 26-1 Pomembne varnostne informacije, preberite pred namestitvijo izdelka (Slovenščina) 27-1 Información de Seguridad Importante. Léase antes de Instalar el Producto (Español) 28-1 Viktiga säkerhetsföreskrifter, läs föreskrifterna innan du installerar produkten (Svenska) 29-1 重要的安全性資訊,在安裝產品前請先閱讀(繁體中文) 30-1 Önemli Güvenlik Bilgileri, Ürünü Kurmadan Önce Okuyun (Türkçe) 31-1 Основні правила техніки безпеки. Уважно ознайомтеся з наведеними правилами перед тим, як приступити до установки виробу (Українська) 32-1

Important Safety Information

For Server, Storage, Power, Networking, and Rack Products Read Before Installing Product

Retain and follow all product safety and operating instructions. Always refer to the documentation supplied with your equipment (printed or electronic documentation). In the event of a conflict between this guide and the equipment documentation, the equipment documentation takes precedence. Observe all warnings on the product and in the operating instructions.

To reduce the risk of bodily injury, electric shock, fire, and damage to the equipment, observe all precautions included in this guide.

Symbols on Equipment

The following symbols may be placed on equipment to indicate the presence of potentially hazardous conditions:

HP PROLIANT BL20P G2 SERVER - Symbols on Equipment - 1

This symbol in conjunction with any of the following symbols indicates the presence of a potential hazard. The potential for injury exists if warnings are not observed. Consult your documentation for specific details.

HP PROLIANT BL20P G2 SERVER - Symbols on Equipment - 2

This symbol indicates the presence of hazardous energy circuits or electric shock hazards. Refer all servicing to qualified personnel.

WARNING: To reduce the risk of injury from electric shock hazards, do not open this enclosure. Refer all maintenance, upgrades, and servicing to qualified personnel.

HP PROLIANT BL20P G2 SERVER - Symbols on Equipment - 3

This symbol indicates the presence of electric shock hazards. The area contains no user or field serviceable parts. Do not open for any reason.

WARNING: To reduce risk of injury from electric shock hazards, do not open this enclosure.

HP PROLIANT BL20P G2 SERVER - Symbols on Equipment - 4

This symbol on an RJ-45 receptacle indicates a Network Interface Connection.

WARNING: To reduce risk of electric shock, fire, or damage to the equipment, do not plug telephone or telecommunications connectors into this receptacle.

HP PROLIANT BL20P G2 SERVER - Symbols on Equipment - 5

This symbol indicates the presence of a hot surface or hot component. If this surface is contacted, the potential for injury exists.

WARNING: To reduce the risk of injury from a hot component, allow the surface to cool before touching.

These symbols on power supplies or systems indicate the equipment is supplied by multiple sources of power. WARNING: To reduce the risk of injury from electric shock, remove all power cords to completely disconnect power from the system
Weight in kg. Weight in lb.This symbol indicates that the component exceeds the recommended weight for one individual to handle safely. WARNING: To reduce the risk of personal injury or damage to the equipment, observe local occupational health and safety requirements and guidelines for manual material handling.

General Precautions

  • If the product sustains damage requiring service, disconnect the product from the AC electrical outlet and refer servicing to an HP authorized service provider. Examples of damage requiring service include:

The power cord, extension cord, or plug has been damaged. Liquid has been spilled on the product, or an object has fallen into the product. The product has been exposed to rain or water. The product has been dropped or damaged. The product does not operate normally when you follow the operating instructions.

To reduce the risk of personal injury or damage to the equipment:

Place the product away from radiators, heat registers, stoves, amplifiers, or other products that produce heat. Never use the product in a wet location. Avoid inserting foreign objects through openings in the product. Move products with casters carefully. Avoid quick stops and uneven surfaces. Use the product only with the HP equipment identified as suitable. Turn down the volume before using headphones or other audio devices.

Precautions for Maintaining and Servicing Enterprise Products

To reduce the risk of electric shock or damage to the equipment when installing, maintaining, or servicing Enterprise products, observe the following precautions:

  • Some Enterprise products contain power supplies that are capable of producing hazardous energy levels. Refer to the documentation included with your product to determine whether it contains these power supplies. The installation of internal options and routine maintenance and service of this product should be performed by individuals who are knowledgeable about the procedures, precautions, and hazards associated with equipment containing hazardous energy levels.
  • Allow the product to cool before removing covers and touching internal components.
  • Do not use conductive tools that could bridge live parts.
  • Remove all watches, rings, or loose jewelry when working in hot-plug areas of an energized server and storage products.
  • Do not attempt to defeat safety interlocks (where provided).
  • The PCI Hot Plug access doors provide access to hazardous energy circuits.

The doors should remain locked during normal operation

-or-

The server should be installed in a controlled access location where only qualified personnel have access to the server.

  • Power down the equipment and disconnect all AC power cords before removing any access covers for non-hot plug areas.
  • Do not replace non-hot plug components while power is applied to the product. First, shut down the product and disconnect all AC power cords.
  • Do not exceed the level of repair specified in the procedures in the product documentation. All troubleshooting and repair procedures are detailed to allow only subassembly or module-level repair. Because of the complexity of the individual boards and subassemblies, do not attempt to make repairs at the component level or to make modifications to any printed wiring board. Improper repairs can create a safety hazard.
  • For floor-standing products, install and extend bottom stabilizers before installing options and boards.
  • Verify that the AC power supply branch circuit that provides power to the rack is not overloaded. This will reduce the risk of personal injury, fire, or damage to the equipment. The total rack load should not exceed 80 percent of the branch circuit rating. Consult the electrical authority having jurisdiction over your facility wiring and installation requirements.

Precautions for Power Products

Power Cords

To reduce the risk of electric shock or damage to the equipment:

Use an approved power cord. If you have not been provided with a power cord for your computer or for any AC-powered option intended for your product, purchase a power cord that is approved for use in your country. - You must use a power cord rated for your product and for the voltage and current marked on the electrical ratings label of the product. The voltage and current rating of the cord must be greater than the voltage and current rating marked on the product. If you have questions about the type of power cord to use, contact your HP authorized service provider. - Do not place objects on AC power cords or cables. Arrange them so that no one may accidentally step on or trip over them. - Do not pull on a cord or cable. When unplugging from the electrical outlet, grasp the cord by the plug. - Make sure that the total ampere rating of all products plugged into an extension cord or power strip does not exceed 80 percent of the ampere ratings limit for the extension cord or power strip. - Do not disable the power cord grounding plug. The grounding plug is an important safety feature. - Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all times.

Power Supplies

  • Hot-plug power supplies are not designed to be removed or installed with AC power connected to the power supply. To reduce the risk of electric shock or damage to the equipment when handling hot-plug power supplies:
  • Install the power supply before connecting the power cord to the power supply.
  • Unplug the power cord before removing the power supply from the product. If the system has multiple sources of power, you must unplug all AC power cords from the power supplies to completely disconnect power from the system.
  • Verify that the external power source connected to your product matches the type of power source indicated on the electrical ratings label. If you are not sure of the type of power source required, consult your HP authorized service provider or local power company.

Uninterruptible Power Supply (UPS) Products

  • To reduce the risk of electric shock and/or equipment damage when installing or servicing UPS products:

The installation of options and routine maintenance and service of UPS products must be performed by trained service technicians who are knowledgeable about the procedures, precautions, and hazards associated with AC power products. - Hardwired UPS products require a direct connection to a dedicated AC branch circuit (AC mains). Connection should only be performed by a licensed electrician in accordance with National Electrical Code (NFPA70) Article 310 in North America or the equivalent local and national wiring regulations.

Use a Lockout/Tagout procedure to isolate hardwired UPS products from AC power before servicing the product or replacing a non-hot plug component. Do not operate a UPS that is disconnected from AC power. Use the TEST/ALARM RESET button to test the batteries. Disconnect all protected loads before disconnecting the UPS from AC power. Pluggable UPS products must be disconnected and unplugged from AC power before servicing the product or replacing a non-hot plug component. Do not overload the output of the UPS. The total connected load should not exceed 80 percent of the rated output. Do not exceed the leakage current limit for the type of UPS in your system. See the "Earth Leakage Current" section later in this document for limits. For rack installations, do not exceed the maximum number of UPS products in any single equipment rack. For rack installations, install the UPS only at the bottom of a rack.

  • To reduce the risk of personal injury or damage to equipment when installing a Remote Emergency Power Off (REPO) port:

The REPO port must be wired by a licensed electrician. Verify that the main AC power disconnect device for the UPS is locked and/or tagged in the OFF position before wiring the REPO port. In North America, the REPO circuit must comply with the NEC (NFPA 70, Article 725) for a Class 2 circuit. In other geographical regions or countries, the REPO port wiring must comply with the national and local standards in the area in which the product is installed.

To reduce the risk of personal injury from electric shock or damage to equipment when installing or servicing batteries:

Make sure that only trained service personnel handle or connect the batteries. Remove watches, rings, or other metal objects prior to working with the equipment. Use tools with insulated handles. On products with remote external batteries, do not attempt to replace batteries unless all battery circuit breakers are in the OFF (down) position. These are hazardous voltage batteries.

This product may contain sealed lead-acid batteries. To reduce the risk of fire or chemical burns:

  • Do not attempt to recharge batteries after they have been removed from the equipment. Do not disassemble, crush, or puncture the batteries. Do not short the external contacts of the batteries. Do not immerse the batteries in water.
  • Do not expose the batteries to temperatures higher than 60°C or dispose of in fire. Use only the HP spare battery designated for this equipment.

Power Distribution Units (PDUs)

To reduce the risk of electric shock and/or equipment damage when installing or servicing PDUs:

  • The installation and routine maintenance and service of PDUs must be performed by individuals who are knowledgeable about the procedures, precautions, and hazards associated with AC power products (trained service technicians).
  • Hardwired PDUs require a direct connection to a dedicated AC branch circuit (AC mains). Connection should only be performed by a licensed electrician in accordance with National Electrical Code (NFPA70 Article 310) in North America, or in other regions or countries, in accordance with the equivalent local and national wiring regulations.
  • Use a Lockout/Tagout procedure to isolate hardwired PDUs from AC power before servicing or replacing the product.
  • Pluggable PDUs must be disconnected from the product and unplugged from the AC electrical outlet before servicing or replacing the product.
  • Do not overload the output of the PDU. The total connected load should not exceed rated input power.
  • Do not exceed the leakage current limit for the type of PDU in your system. See the "Earth Leakage Current" section later in this document for limit.

Earth Leakage Current

To reduce the risk of electric shock due to high leakage currents, a reliable grounded (earthed) connection is essential before connecting power distribution products to AC power. Observe the following limits when connecting the product to AC power distribution devices:

  • For UPS products and PDUs that have attached AC power cords or are directly wired to the building power, the total combined leakage current should not exceed 5 percent of the rated input current for the device. For UPS products and PDUs that have detachable AC power cords, the total combined leakage current should not exceed 3.5 mA.

Voltage Selection

  • On products that have voltage select switches, make sure that the switch is set for the type of voltage you use (115 VAC or 230 VAC).
  • Do not attempt to power the product with voltage converter kits sold for appliances.

Batteries

Some HP products may contain internal lithium manganese dioxide batteries or vanadium pentoxide batteries. There is risk of fire and burns if the battery pack is not handled properly. To reduce the risk of personal injury:

  • Do not attempt to recharge the battery.
  • Do not expose the battery to temperatures higher than 60°C (140°F).
  • Do not disassemble, crush, puncture, short external contacts, or dispose of the battery in fire or water.
  • Replace the battery only with the HP spare battery designated for this product.

HP PROLIANT BL20P G2 SERVER - Batteries - 1

Do not dispose of batteries with the general household waste. To forward them to recycling or proper disposal, use the public collection system or return them to HP, your authorized HP Partners, or their agents.

Precautions for Products Installed in Racks

Stability

To reduce the risk of personal injury or damage to the equipment, be sure that:

The leveling jacks are extended to the floor. The full weight of the rack rests on the leveling jacks. - The stabilizing feet are attached to the rack if it is a single-rack installation. - The racks are coupled together in multiple-rack installations. - Only one component is extended at a time. A rack may become unstable if more than one component is extended for any reason. - You are careful when pressing the component rail release latches and sliding the component into the rack. The slide rails could pinch your fingertips. - You load the rack from the bottom up and load the heaviest item into the rack first. - You do not attempt to move equipment racks without adequate assistance, due to their height and weight. - You do not attempt to move an equipment rack on an incline that is greater than 10 degrees from horizontal. - You do not attempt to move a fully loaded equipment rack. Remove equipment from the rack before moving the rack.

Manual Material Handling

To reduce the risk of personal injury or damage to the equipment:

  • Observe local occupational health and safety requirements and guidelines for manual materials handling.
  • Obtain adequate assistance to lift and stabilize the product during installation or removal.
  • Remove all pluggable power supplies and modules to reduce the weight of the product.
  • Make sure that the product is properly mated with the rails. Products that are improperly mated with the rails may be unstable.

Precautions for Modems, Telecommunications, or Local Area Network Options

To reduce the risk of exposure to shock hazard from telephone ringing voltages:

  • Do not connect or use a modem or telephone (other than a cordless type) during a lightning storm.
  • Do not use a telephone line to report a gas leak while you are in the vicinity of the leak.
  • Do not connect or use a modem or telephone cable in a wet location.
  • Disconnect the modem cable before opening a product enclosure, touching or installing internal components, or touching an uninsulated modem cable or jack.
  • Do not plug telecommunications or telephone connectors into the Network Interface Card (NIC) receptacles.

Precautions for Products with Laser Devices

To reduce the risk of exposure to hazardous radiation:

  • Do not try to open the laser device enclosure. There are no user-serviceable components inside.
  • Do not operate controls, make adjustments, or perform procedures to the laser device other than those specified herein.
  • Allow only HP authorized service technicians to repair the laser device.

.

.

a a

y

-gi

14 15

.

1 1

Ais

i i 1

a

J5.

a

.

A

1

J 1

HP no 100000000000000000000000000000000000000

2a1111

gj gj jgi jgi jgi jgi jgi jgi jgi jgi jgi jgi jgi jgi jgi jgi jgi jgi jgi jgi jgi jgi jgi jgi jgi jgi jgi jgi jgi jgi jgi jgi jgi jgi jgi jgi jgi jgi jgi jgi jgi jgi jgi jgi jgi jgi jgi jgi jgi jgi jgi jgi jgl

a#

a aaaaaan aaannnnaa an aananaan anan anan anan anan anan anan anan anan anan anan anan anan anan anan anan anan anan anan anan anan anan anan anan anan anan anan anan anan anan anan anan anan anan anan anan anan

a aaaee

()

a jz jz jz jz jz jz jz jz jz jz jz jz jz jz jz jz jz jz jz jz jz jz

A

1

Joo

a a a a a a a a a a a a a a

..

aaii aaiiaai iaaaiiaaiiaai

y j 2.

a 1

pIe Iepiepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepe pe

1gdsgj jaaal 15

HP PROLIANT BL20P G2 SERVER - 1 - 1

Smid参加会议, and the members of the group were asked to make a statement.

UPS (Uninterruptible Power Supply) products

PDUs (Power Distribution Units)

Ppoulaeic yia Ppoiovta Tpopoobooia

Kaawia Tpofooboiac

Ipoiovta AdeltaeinnTs Tpopoobooiac (UPS)

Ia va eaattosotov kivduvo nAekponnxiag n/kai nmuac oTov Esoano kaTyn ykarataon n tn ovvtnpon tov npoiovtups:

The UPS must be installed and connected by qualified personnel and must comply with the UPS safety requirements. The UPS products are designed for indoor use only and have an isolated AC input circuit (AC distribution network). The connection must be made only by a licensed electrician in accordance with the National Electrical Code (NFPA70) Article 310 in North America or the corresponding local and national regulations. Use a proper disconnection/isolating procedure to disconnect the UPS from the AC supply before performing maintenance on the product or replacing a battery or an active component. Do not operate a UPS that has been disconnected from the AC supply. Use the TEST/ALARM RESET button to check the batteries. Disconnect all protected loads before disconnecting the UPS from the AC supply. The internal UPS products must be disconnected from the product and from the AC supply before maintenance on the product or replacement of a battery or an active component. Do not overload the UPS input. The total connected load must not exceed 80 percent of the rated output. Do not remove the grounding conductor for the UPS. The system will. If the limit is exceeded, see below the unit "Ground Fault Current" for products installed in a rack or cabinet, do not exceed the maximum current of the UPS. For products installed in a rack or cabinet, install the UPS only in the lower part of the rack.

To reduce the risk of injury or damage during the installation of the bypass switch or emergency power off (EPO):

ninn nnn nn, lnonx nnnn nn

yipn np nynnnn nn nnynnn nynnnn ynpn np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np np

nnn nbn npn, nsh pnn, nn, shyn bn, nyn ny nny npn by

Tyn by yin no

y 100

no 7n no n nn no n nn no

HP PROLIANT BL20P G2 SERVER - ninn nnn nn, lnonx nnnn nn - 1

n790X 77 nn non,77nn n nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn

ywnnnn nn nnnn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn

HP PROLIANT BL20P G2 SERVER - ninn nnn nn, lnonx nnnn nn - 2

Enterprise

n nn nnn, npnn nyaa y na nn no by

: nnnn nn nn nn nn ,Enterprise nn nn nn

y .n nn nnnn nnnn nnnn nnnn nnnn nnnn nnnn nnnn nnnn nnnn nnnn nnnn nnnn nnnn nnnn nnnn nnnn nnnn nnnn nnnn nnnn nnnn nnnn nnnn nnnn nnnn nnnn nnnn nnnn nnnn nnnn nnnn nnnn nnnn

n nn n nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn

Pn npnnn nnnn nn nnnn nn nnnn nn nnnn

y

.

N

n nn nnnn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn

y y n nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn nn

  1. 10NN 7NIN N

(1)

HP PROLIANT BL20P G2 SERVER - Enterprise - 1

HP PROLIANT BL20P G2 SERVER - Enterprise - 2

HP PROLIANT BL20P G2 SERVER - Enterprise - 3

(in no 90) UPS

UPS 100000000000000000000000000000000000000000000000

UPS

TEST/ALARM RESET 1000000000000000000000000000000000000000000

nnpnUPS-n pnnn nn nnnn nn nnnn

.

UPS

on-wwyipn nn

80 by nynn nn nnnn nn nnnn. UPS-n nn nn nn nn nn

Nnn

n nnnnnpuPS u npnnpnnpnnp

__SUPPIMER__

HP PROLIANT BL20P G2 SERVER - (in no 90) UPS - 1

Do not expose yourself to temporary laser radiation:

Do not attempt to open the laser device housing. There are no user-serviceable parts inside. Do not attempt to perform adjustments, alignments, or other procedures other than those described in this section. Laser device repair should only be performed by authorized service technicians.

Safety Important Information

During server operation, when saving data, connecting to the network, or organizing network equipment racks

Please read the following rules carefully before installing and operating the device.

Carefully study the safety documentation supplied with the device (in printed or electronic form) and strictly follow all instructions. In case of discrepancies between the text of this manual and the device documentation, the device documentation takes precedence. Pay special attention to all warning labels on the device and in the operating documentation.

Follow all instructions in this manual to avoid injury, electric shock, fire, or damage to the device.

Safety symbols and markings on the device

The following safety symbols and markings may be placed on the device in places that are potentially hazardous:

Ley cimboj y cnoluyehni 3 6ydb-ram 3 habe de hnhx nghye cimboiB Bka3yE ha haeBHicb ToteHciHoI Hebe3nekn. Topyuhenr Bmorg be3nekn moxe npin3bcevn do tpabmi. BiIbss detaIbha inΦopMaizg HabeDeHa y BiDnOBiDnH i dokymentauii.
Ley cimboj Bka3yE ha haeBHicb eNeKTPnuHnx IaHc0riB niD hapyukenm afo ha haeBHicb dKepeLa Hebe3neHoro hapyukenr. ObcnyroBuBatn i peMOHTyBatn taki By3ni Mycarb npopecini φaxibci 3ACTEPEXEHN. Κθ6 3anobirtn ypaJeeHNIO eNeKTPnuHNM ctpyom - 3aboponeHO 3Himatn 3axncn Koxyxn. ObcnyroBuHNN, peMOHT i ModuPikaio Tackx By3niB nobHHi po6bntn npopecini φaxibci
Ley cimboj Bka3yE ha haeBHicb Hebe3neHoro Hapyukenr. HeobxdHn pEmoHT MOxHa po6bntn TiIbKn y cpeuaJIbHi maJCTepH. 3aboponeHO 3Himatn 3axncn KpNIcky. 3ACTEPEXEHN. Κθ6 3anobirtn ypaJeeHNIO eNeKTPnuHNM ctpyom 3aboponeHO 3Himatn 3axncn OKOxyxa.
Ley cimboj Ha po3natti RJ-45 o3Nauee πidKnUoyenHn do komn'otepHOI MEPexi. 3ACTEPEXEHN. Κθ6 3anobirtn ypaJeeHNIO eNeKTPnuHNM ctpyom, BnHikHeHNO noxexi abo BIXOdu oblaDaHnH 3i ctpoH, 3aboponeHO πidKnUoyatn do zuBO rpo3nTTA shypn TeJeΦoHORO qH TeLEKOMYHkauziHOrO oblaDaHnH.
Ley cimboj Bka3yE ha haeBHicb πidirpiToI do BnCOKoi tempepatyr DiJINHKn NobepxHl 6bIaHaHnH. 3ITKHeHn 3 TAKO noBepxHeO Moxe 3anodIaTn TpaBMy. 3ACTEPEXEHN. Ipeed TIm,Як доTopKHytncbdo TakoI nobepxHl, TpeBa datn iI oxOLOHyt.

HP PROLIANT BL20P G2 SERVER - Safety symbols and markings on the device - 1

This symbol indicates that the device is powered by multiple power sources.

WARNING: To avoid electric shock, completely disconnect the system from all power sources before servicing.

HP PROLIANT BL20P G2 SERVER - Safety symbols and markings on the device - 2

Voltage Danger

This symbol indicates that the voltage at the corresponding device node allows it to be moved only by qualified personnel.

WARNING: To avoid injury or damage to the device, follow the internal safety rules when performing manual lifting work.

General safety rules

If the device is damaged or requires repair, it must be disconnected from the AC power outlet and a specialist from the "HP" company service center must be called. Only specialists are allowed to eliminate the following faults:

Damage to the power cord, power plug, or plug connector. Penetration of liquid or foreign objects inside the device. □ Liquid ingress into the device. Mechanical damage to the device. Unauthorized repair of the device under normal operating conditions is not permitted, as specified in the operating instructions.

To prevent accidents or device failure:

Do not place the device near heating radiators, heating registers, stoves, or other equipment that generates heat. It is strictly forbidden to use the device in damp or wet rooms. Do not insert foreign objects through the openings into the device. Move the device carefully on its casters. Do not make sharp turns and do not leave the device on inclined surfaces. Use the device only as part of the "HP" equipment set. If you need to use a telephone or other device, you must change the volume level.

Safety measures during maintenance and operation of the device

To prevent electric shock or device failure during installation and operation of the device, follow the following safety rules:

■ The device has power sources with dangerous voltage. Read the documentation included in the delivery to know which power sources a particular device has. Only persons who have thoroughly studied the safety rules can be allowed to install, maintain, and operate the device. ■ Before removing the cover to work with internal components and parts, you must let the device cool down. It is forbidden to use electric tools, as they can damage parts under voltage. ■ Before starting work with the device, you must disconnect it from the power source (by unplugging the power cord from the outlet) or from the server or other connected equipment. You must remove your watch, rings, and other jewelry.

Do not remove the blocking devices where they are installed. ■ Through the holes that lead to the device, there are electrical circuits with dangerous voltage.

Work with the device must be carried out by qualified personnel only, in a room with restricted access, or with a server. The device must be installed in a room with restricted access, and only qualified personnel should work with it.

Before starting any repair work, it is necessary to disconnect the equipment from the power supply and unplug the power cord from the AC outlet. It is forbidden to perform repairs with the equipment connected to the power supply. First, you must disconnect the equipment and unplug the power cord from the AC outlet. Repair work should only be carried out by qualified personnel authorized for specific types of repairs in the equipment's operating documentation. All work on troubleshooting and repairing is intended at the level of units and modules. Some units and devices have a complex structure and circuit design, so it is forbidden to perform repairs at the level of circuit elements or make modifications to printed circuit boards. Incorrectly performed repairs can become a source of danger to human health. Before starting repairs, you must ensure that the equipment is disconnected from the power supply. Make sure there is no voltage in the equipment's power supply circuit. This will eliminate the risk of electric shock and prevent equipment failure. The total load on the equipment should not exceed 80% of the rated load on the power supply line. Before starting repairs, consult with representatives of the local energy service.

SAFETY PRECAUTIONS DURING WORK WITH POWER ELEMENTS

ELECTRICAL SAFETY

To avoid electric shock or equipment failure:

Use only the standard power cord. If the standard power cord of the computer is missing, use a cord that is approved for use in your country. Use a power cord rated for the current and voltage specified on the equipment. The rated current and voltage of the power cord must be greater than or equal to the rated values indicated on the equipment itself. In case of damage to the cord, contact the official representative of the local service center of the company "HP". - Do not place the power cord under any objects. Route the cord so that service personnel do not step on it or trip over it. Do not pull the cord when you need to unplug it from the outlet; instead, grasp the plug with your hand. The total rated load on the power cord when connecting multiple devices via an extension cord or power strip must not exceed 80% of the rated load on the cord for that extension cord or power strip. Monitor the condition of the grounding contact of the power cord. A properly functioning grounding contact is an important element of ensuring operational safety. Connect the power cord only to a grounded outlet located in an easily accessible place.

Power Source

To prevent the so-called "arc flash" hazard, disconnect the power source before working on the equipment when the power is turned off from the AC power source. To avoid electric shock or equipment damage and to ensure safe operation with power sources, the "arc flash" hazard:

Disconnect the power source only with the power cord unplugged. Before disconnecting the power source from the device, you must unplug the power cord. If the system is powered from multiple sources, unplug all power cords to ensure the device is completely disconnected from the power supply.

Make sure that the power source you connect to the device matches the type indicated on the nameplate of electrical characteristics, which is installed on the device itself. If you have any doubts about the type of power source, contact your local service center of the company "HP" or the representative of your local power company.

DISCONNECTING THE POWER SOURCE (DPS)

To prevent electric shock or equipment damage during installation, operation, or maintenance:

Before installation, maintenance, or operation, only qualified technical specialists who have thoroughly studied the operating procedures with electrical equipment and comply with electrical safety rules should be allowed. They must be directly connected to the AC power source. Connection must be made by a qualified electrician in accordance with the requirements of Article 310 of the National Electrical Code (NFPA 70) or equivalent national standards, which regulate connection procedures. Before performing maintenance on the device or replacing any components that require disconnecting the power source, you must check the labels and install lockouts to prevent accidental reconnection. It is forbidden to work with devices that are connected to the AC power source. Before checking the charge, use the TEST/ALARM RESET button (reset control/alarm signal). Before disconnecting the device from the AC power source, first disconnect all loads. The device must be disconnected from the AC power source before performing maintenance or replacing any components that require disconnection. Do not overload the outputs. The total connected load must not exceed 80% of the nominal value. Ensure that the output currents do not exceed the maximum level specified for this type of device. The limits of output currents are given in the section "Output Currents to Ground" of this manual. When placing equipment on a rack, ensure that the total weight does not exceed the established maximum limit. When placing equipment on a rack, the device must be installed only in the lower part of the rack itself.

To prevent injury or damage to equipment, if the installation is not equipped with an "Emergency Power Off" (EPO) switch, the following requirements must be met:

Connection of the DIBK device must be performed by a qualified electrician. Before connecting the DIBK, it is recommended that the main power supply of the device be disconnected and locked in the disconnected state, and the corresponding warning plate be posted. In the countries of North America, the DIBK must comply with the requirements of national electrical codes and standards (NFPA 70, Article 725) for Category 2 circuits. In other geographic regions and countries, the DIBK connection scheme must comply with the requirements of national standards or other applicable standards of the country where the connection is made.

To prevent electric shock or equipment damage during installation or operation, follow these instructions:

Ensure that battery installation and maintenance are performed only by specially trained personnel. Before working with the equipment, remove rings, watches, and other metal objects. Use tools with insulated handles. Replace batteries only after disconnecting all power supply lines and setting the switch to OFF. Voltage may still be present at some battery terminals and is dangerous to life.

The product may contain sealed lead-acid batteries. To prevent burns or acid burns, observe the following safety measures:

It is forbidden to disassemble the battery. It is forbidden to disassemble, crush, or puncture the battery. It is forbidden to short-circuit the external terminals of the battery. It is forbidden to immerse the battery in water. It is forbidden to heat the battery above 60 degrees Celsius or dispose of it by incineration. Use only batteries of the specified type, specially designed for this equipment.

Peripheral devices

To prevent electric shock or equipment damage during installation and operation of peripheral devices, observe the following safety measures:

Only qualified personnel who have thoroughly studied the operating procedure for power tools and comply with electrical safety rules (trained technical personnel) are allowed to service and operate power tools. Power tools are connected directly to the AC mains. Connection must be performed by a qualified electrician in accordance with the requirements of Article 310 of the National Electrical Code (NFPA 70) of the United States or an equivalent national standard governing connection procedures. Before servicing or replacing the tool, it is necessary to identify the appropriate tag and install a lockout to prevent accidental connection of the power tool to the AC mains. Portable power tools must be disconnected from the mains and locked out before servicing or replacement. Do not overload the power tool's output. Always ensure that the connection does not exceed the maximum rated output power. Ensure that the circuit breaker does not exceed the maximum rated type of the power tool's system. The limits of the new circuit breaker are given in the "Grounding" section of this manual.

Grounding

To prevent the risk of electric shock due to the ground fault current exceeding the permissible maximum, before connecting power tools to the AC mains, an appropriate grounding system must be installed. When connecting the tool to power tools with AC, consider the following limit values:

For power tools that have a fixed power cord with AC or are directly connected to the building's mains, the total ground fault current must not exceed 5% of the tool's rated input current. For power tools that have a detachable power cord with AC, the total ground fault current must not exceed 3.5 mA.

Selecting the input voltage

If the tool has a voltage selector switch, you must ensure that the switch is in the position corresponding to the existing mains voltage (115 V AC or 230 V AC). It is forbidden to change the voltage using homemade transformers.

Batteries

Some HP products may contain nickel-cadmium or nickel-metal hydride batteries. Improper use of batteries may cause fire or burns. To avoid the risk of injury, follow these instructions:

It is forbidden to disassemble the battery. It is forbidden to heat the battery above 60 degrees Celsius (140 degrees Fahrenheit). It is forbidden to disassemble batteries, damage or puncture them, short-circuit the external terminals, and also to dispose of them through incineration or throw them into water. As a replacement, only spare batteries from "HP" company, specially designed for this product, may be used.

HP PROLIANT BL20P G2 SERVER - Batteries - 1

It is forbidden to transport batteries on public roads. To hand over batteries for recycling, you must contact the state authorized recycling functions or their HP company representatives or HP company authorized service centers.

Safety instructions for working with equipment installed in a rack

Stability

To prevent injury or damage to equipment, it is recommended that:

The horizontal supports of the rack and the floor must be level. The rack rests with its entire weight on the horizontal supports. Secure the rack to the floor (if all equipment is located in one rack). Connect the racks to each other (if the equipment is located in several racks). Only one unit can be pulled out at a time. If for any reason two or more units are pulled out, the rack may lose stability. When pulling out the units, do so carefully. Make sure that when pulling out, the units do not pinch your hands. Install the equipment in the rack from the bottom up, starting with the heaviest unit in the lowest position. Move the rack with the help of a sufficient number of people, taking into account the height and weight of the rack. The rack cannot be moved on a surface that has an incline of more than 10 degrees relative to the horizontal. - The rack cannot be moved together with the equipment. Before moving, remove the equipment from the rack.

Manual handling work

To prevent injury or damage to equipment:

Follow internal safety and labor protection rules for manual handling work. All work on lifting and moving the product during installation must be performed with the help of a sufficient number of people. To change the weight of the product, remove all removable power sources and modules from it. It is recommended that the product be firmly secured in the direction. Otherwise, if the product is not firmly installed in the direction, it may lose stability.

Safety instructions for working with modems, telecommunication equipment, and local network equipment

To prevent electric shock from the output signal, use the following safety measures:

Do not use or connect the modem or telephone (unless it is of the cordless type) during a thunderstorm. Do not use the telephone to report a gas leak in the vicinity of the leak. Do not connect the modem or telephone cable in a wet environment. If you need to remove the cover from the equipment and work with internal parts or parts that come into contact with the unused modem cable or connector, disconnect the modem cable. Do not insert metal connectors of telecommunication or telephone cables into the connectors of the network interface cards (NICs).

Safety instructions for working with laser devices

To prevent accidental exposure to laser radiation:

It is forbidden to open the housing of the laser device. The device does not contain parts that require user maintenance. Adjustment of the laser device must be performed in strict accordance with the instructions in this manual. Repair of the laser device must be carried out only by authorized HP service technicians.

©2002 Hewlett-Packard Company

Hewlett-Packard Company shall not be liable for technical or editorial errors or omissions contained herein. The information in this document is provided "as is" without warranty of any kind and is subject to change without notice. The warranties for HP products are set forth in the express limited warranty statements accompanying such products. Nothing herein should be construed as constituting an additional warranty.

Fifth Edition (July 2002)

Part Number 296382-025

HP PROLIANT BL20P G2 SERVER - Safety instructions for working with laser devices - 1

296382-025

Table of contents Click a title to access it
Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : HP

Model : PROLIANT BL20P G2 SERVER

Category : Server