Heylo

TD 300 - Ventilateur domestique Heylo - Free user manual and instructions

Find the device manual for free TD 300 Heylo in PDF.

📄 14 pages English EN Download 💬 AI Question
Notice Heylo TD 300 - page 9
View the manual : Deutsch DE English EN
Pick your language and provide your email: we'll send you a specifically translated version.

User questions about TD 300 Heylo

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Ventilateur domestique in PDF format for free! Find your manual TD 300 - Heylo and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. TD 300 by Heylo.

USER MANUAL TD 300 Heylo

natural_image Orange HEYZO air conditioner unit with control panel and fan (no visible text or symbols)

Heylo TD 300 - 1

natural_image Orange circular background with a white and dark dot pattern in the center (no text or symbols)

TD 300 MID VENTILATOR

BEDIENUNGSANLEITUNG

USER MANUAL

Heylo TD 300 - USER MANUAL - 1

DE Ventilator

Heylo TD 300 - USER MANUAL - 2

EN Air mover

text_image Exploded view diagram of an electric motor assembly with numbered components

11. Schaltplan

230V\~ / 50Hz

Brownbr
Bluebl
Whiteweiß
Greengr
Redrot
blacksw
Green/yellowgr/ge

Heylo TD 300 - Schaltplan - 1

text_image YELLOW/GREEN M RED 1.5μF/500VAC RED BLUE BROWN Switch ④ MID ① ③ BROWN BLUE Cord YELLOW/GREEN

HEYLO

EC Declaration of Conformity, IIA In conformity with EC Machine Directive 2006/42/EC,

For unit series: Ventilators Type: TD300 MID

HEYLO GmbH of Im Finigen 9, D-28832 Achim, Germany, declares that, if they are fitted, maintained and used in conformity with the operating instructions and the generally accepted engineering standards, the machines mentioned are in keeping with the fundamental safety and health requirements of the “Machine Ordinance” as well as with the regulations and standards mentioned hereinafter.

Applicable EC directives:

EC Machinery Directive 2006/42/EG

Low Voltage Directive 2014/35/EU

EMC Directive 2014/30/EU

EMC Directive 2009/125/EG

RoHS 2011/65/EU

In case of unauthorised changes of the machine, the directives shall forfeit their validity.

Applied standards:

DIN VDE 0700 Part 1 and Part 30

DIN EN 55014-1:2012-05

EN 60 335-1

EN 60 335-2-30

CE

Achim, 14th Mai 2018

Milledo

Dr. Thomas Wittleder - Managing Director -

Table of contents

  1. General information 9
  2. Use of ventilators/fans 9
  3. Installing the devices 10
  4. Cooling and ventilating 10
  5. Moisture control 10
  6. Operating the devices....10
  7. Repairs/maintenance....10
  8. Technical Data....11
  9. Troubleshooting....11
  10. Spare parts list.... 12
  11. Wiring.... 13

1. General information

CAUTION: Read carefully before starting up!

Please observe the notes in the operating instructions carefully. In case of non-observation, the warranty claims will become void. The manufacturer shall not be liable for any damage and/or consequential damage resulting.

Introduction This section includes general information on the device and on the manual.

Target group The manual is intended for service engineers installing the device, carrying out maintenance work and changing defective parts.

Copyright Copying the manual, as a whole or in parts, is only permitted with the written approval of HEYLO GmbH!

Conditions HEYLO GmbH reserves the right to make changes and improvements to the product and manual without prior announcement or notification.

Disposal The device is designed for long term operation. If it has to be disposed of, this must take place in accordance with the respective legal regulations in an environment friendly manner.

Safety instructions!

Keep out of reach of children: Do not allow children to play with the device or near the device.

Electrical connection: Fans and ventilators are designed for operation at 230V/50Hz. Use only with a plug with earthing contact! Sockets used must be earthed and have to save by a fault current protection switch.

Protect power cable from damage: Never use the device with a damaged power cable. If the power cable is damaged, it must be replaced by a cable of the same type and dimensions.

Extension cable: Only used approved extension cables!

Handle with care: Do not drop or throw the device since this could lead to damage of components or wiring.

Place on a steady surface: Always place the device on a steady, even surface.

Make sure it is fixed in place during transport: Tie down the device during transport to prevent it from slipping and sliding.

Keep it dry: The device cannot be operated in puddles or stagnant water. Do not store or operate it in open spaces. If the electric wiring or parts of the device get wet, dry it thoroughly before using it again.

Keep the air vents free: Do not cover or block the air inlets and outlets.

2. Use of ventilators/fans

The fans are designed in such a way that they blow air over moist surfaces to dry them quickly. They are particularly suitable for drying floors, since they produce a flat air column. A high volume air flow increases evaporation, helps prevent the formation of mould and mildew and reduces the risk of additional damage caused by moisture. Flowing air improves evaporation since it blows away the film of saturated air on the boundary, lying above wet surfaces.

3. Installing the devices

At least one turbo dryer must be installed in each room to dry out a building. Air is to be produced on three sides. Please make sure that all wet surfaces are exposed to air flow.

4. Cooling and ventilating

Overheated rooms can be cooled by the high volume air flow of a fan. Place the device on the floor or another even surface for this purpose and let the air flow in from cooler areas or from outside.

5. Moisture control

If fans are used to increase evaporation in a building the air moisture usually also immediately increases. When this happens, the movement of air becomes less effective and drying slows down. It is therefore necessary that the fans are used together with a sufficient number of dehumidifiers. Air moisture in rooms must be held at under 60% to keep formation of mould and mildew under control. If possible air moisture in rooms should be under 45%. HEYLO dehumidifiers can be used for this purpose.

The area to be dried must be separated from the rest of the building to improve the drying process. Set heating or air conditioning to 20-27°C. If no dehumidifiers are available, ventilators should be used in attics, kitchens and bathrooms to get rid of moisture. If the outside air is very dry, windows or doors can be left slightly ajar.

6. Operating the devices

Connect the device to an earthed socket. Set the switch to turn on. Check for correct operation, before the unit is left unsupervised.

Do not move or carry the fan during operation.

The device is equipped with a calibrated energy meter. Please read the meter reading before startup and after the end of the work. The difference is the energy consumption in KWh

7. Repairs/maintenance

Attention: Always pull out the mains plug before maintenance and repair work.

INSPECTION OF THE ELECTRICAL SYSTEM: Check the electricity cable regularly for damages. Remove the housing regularly and check the internal wiring for blank conductors, loose fittings and discolouration. Take out and repair damaged cables if necessary.

CLEAN AIR INLETS: Fluff and other dirt that has collected at the air inlet must be removed. Remove fluff, lint and dust from the fan wheel, motor and side covers with a vacuum or compressed air.

CLEAN HOUSING: Clean the housing with a mild detergent and water. Restore the original shine with vinyl cleaner and polish, e.g. used for synthetic materials for vehicles.

EXTERNAL CHECKING: Check the external parts and make sure that they have been properly installed. Look out for unusual noises.

ENGINE AND WIRING MUST REMAIN DRY: The turbo dryer cannot be cleaned with a water hose or pressurised washing device to prevent electrical components from getting damaged. If electrical components still get wet, they must be dried immediately.

8. Technical Data

ModelTD 300
Air flow rate max.445 m^3/h
Connection230V / 50Hz
Fuse16 A
Height x Width x Depth30 x 25 x 28 cm
Weight3,2 kg
Engine output85 W
Noise level at 1 m distance58 dB(A)
IP-classIP 22

Attention: Technical data can be changed during the course of further development without prior announcement. Some values are approx. – values.

9. Troubleshooting

WARNING: All maintenance work listed below must be carried out without current, i.e. with the plug pulled out.

PROBLEMCAUSEExec.SOLUTION
Motor does not runNo power supply to the deviceSwitch not turned onFan wheel blockedAir inlet or outlet blockedSwitch interruptedWiring looseBBBBBBASTASTConnect device, check fuse.Turn on switchRemove reason for blockageSwitch off machine and let it cool off; then remove blockage.Order a replacement switch from the dealer or HEYLO.Check wiring and tighten as per requirement.
Motor runs but wheel turns irregularly or hits the sidesA heavy impact has bent the engine suspension so that the wheel is stuck.A heavy impact has let the engine slide out of the suspension so that the wheel is stuck.ASTASTDismantle engine from the housing, then replace or repair the bent engine suspension.Dismantle the engine from the housing and then place it correctly into the suspension.
Device vibrates excessivelyCollection of dirt on the wheelUnbalance of the fan wheelFan wheel bentMotor shaft bentBASTASTASTASTClean fan wheelBalance out or replace fan wheelChange fan wheelChange motor

Exec.: B - User AST - authorised service engineer

Contact your local dealer or HEYLO customer services department for spare parts and service.

10. Spare parts list

ItemHEYLO Item No.Description
11750160grille
21750159fan
31750161housing
41750157Motor
51750167foot
61750156front grille (discharge side)
71750151switch ON/OFF
8DE02-01646MID energy counter
-1750155cable
-1750153Stain-relief for cable
-1750154Stain-relief inside
-1750152Cover-cap for on/off switch

Heylo TD 300 - Spare parts list - 1

text_image Exploded view diagram of an electric motor assembly with numbered components

11. Wiring

230V\~ / 50Hz

Brownbr
Bluebl
Whiteweiß
Greengr
Redrot
blacksw
Green/yellowgr/ge

Heylo TD 300 - Wiring - 1

text_image YELLOW/GREEN M RED 1.5μF/500VAC RED BLUE BROWN Switch MID ④① ③② BLUE BROWN Cord YELLOW/GREEN

Heylo TD 300 - Wiring - 2

SIE HABEN FRAGEN? WIR HELFEN IHNEN GERN! Do you have any questions? We are happy to help you!

HEYLO Kundendienst – Technischer Support und Service HEYLO Customer Service – Technical Support and Service

Tel. +49 (0) 42 02 - 97 55 15

For your construction site, production facility or event via the HEYLO rental network:

www.heylo-mietservice.de

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Heylo

Model : TD 300

Category : Ventilateur domestique