| Product Type | Undercounter Refrigerator |
| Model | IMC82BC |
| Brand | Scandomestic |
| Dimensions (H x W x D) | 82 cm x 59.5 cm x 54.5 cm |
| Weight | 30 kg |
| Power Supply | 220-240 V, 50 Hz |
| Energy Consumption | Approx. 100 kWh/year |
| Climate Class | N-ST |
| Temperature Range | +2°C to +8°C |
| Defrost Type | Manual |
| Adjustable Thermostat | Yes |
| Interior Light | Yes |
| Reversible Door | Yes |
| Number of Shelves | 3 (glass) |
| Door Bins | 3 |
| Crisper Drawer | Yes |
| Maintenance | Clean with mild soap; defrost when ice > 5 mm |
| Safety Features | Stable shelves, proper ventilation |
| Spare Parts Available | Shelves, door bins, thermostat |
| Warranty | 2 years (standard) |
Frequently Asked Questions - IMC82BC Scandomestic
User questions about IMC82BC Scandomestic
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Refrigerator in PDF format for free! Find your manual IMC82BC - Scandomestic and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. IMC82BC by Scandomestic.
USER MANUAL IMC82BC Scandomestic
natural_image
Black plastic laboratory condenser unit with clear glass lid and ventilation slots (no text or symbols visible)natural_image
Symbol of a trash bin crossed with no text or numbers, representing waste sorting or disposal (no text present)Please read this manual book carefully before use and operate according to this manual book
Please keep it well and for your reference.
This manual is original in English.
Proper use
The refrigerated and frozen food cabinet described in this operating manual is intended for storing snacks, cold drinks, dairy products and frozen foods or ice cream.
Do not load the cabinet with non-frozen products and do not try to freeze products in the case.
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
Children should be supervised to ensure that they do not play with the appliance.
Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance.
WARNING: Keep clear of obstruction all ventilation openings in the appliance enclosure or in the structure for building-in.
WARNING: Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer.
WARNING: Do not damage the refrigerant circuit.
WARNING: Do not use electrical appliances inside the food
storage compartments of the appliance, unless they are of the type recommended by the manufacturer.
Proper use only means the use as described above, adhering to the specifications on installation, connection, operation and service. Any other use is regarded as being contrary to specification and is prohibited.
To avoid any damage during the transport or the installation, never tilt the cabinet more than 50^
Safety regulation
Warning: Keep ventilation openings in the appliance enclosure or in the structure clear of obstruction.
Warming: Do not damage the refrigerant circuit.
If the cabinet is filled with refrigerant Propane (R290) please read carefully the attached Safety Instructions. The type of refrigerant is documented in the cabinet's type plate.
Refrigerating units operating on Propane (R290) may not be placed in an area with sources of ignition (e.g. unsealed electrical contacts) or where the refrigerant could gather in the event of a leak. The type of refrigerant is indicated on the cabinet's type plate.
The plug-in refrigerated cabinets as described in this operating manual are designed and manufactured in compliance with the international safety regulations.
Like any electrical appliance, it must be handled with all due care, particularly with consideration to ensuring electrical safety.
To ensure safe operation in all service conditions, the following safety precautions must be observed:
- The device may not be used by persons with limited physical, sensory or mental skills and/or with no experience and/or knowledge.
- Never connect the cabinet to the power supply if it is damaged (in transit or otherwise). When in doubt, contact your Service Organization or dealer.
- Contact your Service Organization if you are in any doubt about electrical connection, working or safety of your plug-in refrigerated cabinet.
- The power plug must be connected in regulation matter and the electrical power supply must be as indicated on the type plate.
- Never work yourself on electrical equipment.
- Electronic and electrical elements (e.g. damaged cable) may only be replaced by a qualified electrician or person with experience in electrical engineering! Safety first!
- If any damage occurs to the power cable, pull the plug to disconnect the cabinet. Please make sure that the cabinet can't be switched on again. Call your local Service Organization.
- Damaged fluorescent tubes, starters and 1 or tube covers must be replaced immediately. Contact your local Service Organization.
- When disconnecting the power plug, always pull on the plug itself and never the cable.
- Remove the cabinet from use if it is not working properly or exhibits any damage. Disconnect the power plug, transfer the merchandise to other cabinets or a cold-room and call your local Service Organization.
Product overview

1 Cabinet opening
2 Front glass
3 Left side panel
4 Advertising nail
5 Evaporator
6 Fan
7 Power supply
8 Thermostat
9 Switch
10 Power cord
11 Return air glass
12 Universal wheel
13 Universal wheel (with brake)

natural_image
Black plastic laboratory condenser unit with clear glass panel and ventilation slots (no text or symbols visible)14 Condensing fan
15 Condensing fan screen cover
16 Fan blade
17 Condenser
18 Compressor
19 Right side panel
20 Left wind deflector
21 Right wind deflector
22 LED strip
23 Lower glass door
24 Upper glass door
Installation
Single-row line-up
When cabinets are installed side by side, no distance is required between the end walls of the refrigerated cabinets under normal.
Ambient conditions.
Group installation, back to back When two IMC82BC cabinets are installed back to back, this can be done without a distance between the rear walls.
Requirements for electrical connection
The cabinet s connected by inserting the power plug in a socket (fig. 7).
The cabinet must not be plugged into a multiple outlet power strip (see lig.8) The socket employed must be firmly installed, properly earthed and separately fuse-protected by a 10A-circuit breaker, type C.
Supply voltage and frequency of the socket must be in accordance with the data shown on the type plate of the cabinet. Therefore, the cross-section of the wires must be increased, if necessary. for long wires to the socket. The local utility company's regulations on the power connection (e.g earth-fault protection, additional equipotential bonding, remote control switch etc.) must be observed. If in doubt, consult a qualified electrician.
- Run the power cables so that they are protected from risk of damage and there is no risk of tripping (fig.9).
- Please do not drill in the outer or inner of the cabinet. This might damage the refrigeration circuit.
- If necessary. put the plugs of electrically operated accessories (e.g. the display super structure) into separately secured sockets.
- The power cable may not come into contact with parts over 75°C.
Starting
Measures prior to starting
If the cabinet has been sharply tilted while being sited or for mounting of accessories, it must be left to stand for at least three hours before being started to allow the lubricating oil to settle in the compressor! Failure to do so can cause total destruction of the compressor refrigerating system.
Setting into operation
- Start the cabinet only if it has been installed as described.
- Plug power plug (1-1) in socket (1-2).
- When selecting the socket, observe the requirements stated in section
- The cabinet must not be plugged into multiple-outlet power strip (see fig.2).
- Switch on remote control switch (fig.2) or provided. Starting is signaled by the low running noise of fans and refrigeration system.
Customer should close the lids properly. if not, condensation might happen.
Specifications
| Type | IMC82BC | |
| Length | [mm] | 730 |
| Width | [mm] | 450 |
| Height | [mm] | 900 |
| Display area | [m2] | 0.86 |
| Useful capacity | [I] | 68 |
| Rated power input | [w] | 250 |
| Rated Current | [A] | 1.5 |
| Temperature | [°C] | -1~7 |
| Rated Voltage Range | [V] | 220-240 |
| Rated Frequency | [Hz] | 50 |
Troubleshooting
Any trouble occurring might be due to a minor problem that you can correct yourself following the instructions below. Do not try any further action if the pointers given cannot solve the problem!
Repairs on the cabinet must be made only by qualified specialists. Incompetent repair work can cause serious personal danger, contact your Service Organization for any repairs needed.
| Trouble | Possible cause | Corrective measures |
| The cabinet does not work (no audible running noise or only fan noise audible). | Automatic evaporator defrosting active or electronic controller witched off.Power plug not connected or remote control switch (where provided) switched off.Fuse blown, power plug or socket defective.Condenser fins fouled. | Not required, as cooling will switch on automatically again.1. Insert power plug properly in or switch remote control switch on.2. Contact your electrician or the Service Organization.3. Perform maintenance. |
| Cabinet Stopp's running after short operation. | Condenser fins fouled. | Perform maintenance. |
| Storage temperature is too high. | Automatic evaporator defrosting active.Ambient temperature too high or electronic controller misadjusted.The warm air outlet of another cabinet is directly taken in as air intake.Ventilation slots blocked or covered.Lack of air intake due to obstruction of air intake grille.Condenser fins fouled. | Not required, temporary minor temperature rise during defrosting is normal.Avoid extreme operating environment, readjust storage temperature.Observe single-row line-up and group installationKeep ventilation slots free.Remove any obstacles in the air intake area.Perform maintenance. |
| Storage temperature is too high. | Misadjustment | Adjust storage temperature in small increments. |
| Storage temperature is too low. | Drip water gutter under base plate fouled | Clean |
| Condensation on the sliding glass lids | Wrong close of the sliding lids | Close the lids properly |
R290 refrigerant is used for this equipment.
WARNING; Risk of fire / flammable materials
Caution!
Consult repair manual/owner's guide before attempting to install or service this product. All safety precautions must be followed. Dispose of properly in accordance with federal or local regulations. Risk of fire or explosion due to puncture of refrigerant tubing. Follow handling instructions carefully.
Danger!
Risk of fire or explosion. Flammable refrigerant used. To be repaired only by trained service personnel. Do not use mechanical devices to defrost refrigerator. Do not puncture refrigerant tubing.
Disposal

natural_image
Symbol of a trash bin crossed with a diagonal line, no text or numbers presentEU regulations require refrigeration product to be disposed of by specialist companies who remove or recycle all gasses, metal and plastic components.
Consult your local waste collection authority regarding disposal of your appliance. Local authorities are not obliged to dispose of commercial refrigeration equipment but may be able to offer advice on how to dispose of the equipment locally.
All packaging materials should be disposed of in an environmentally friendly way.
The cardboard may be used as scrap paper. The protective foil and the foam cushions are CFC-free.
Do not allow children to play with the packaging and destroy plastic bags safely.
Environmental protection
Discarded electric appliances are recyclable and should not be discarded in the domestic waste! Please actively support us in conserving resources and protecting the environment by returning this appliance to the collection centers (if available).
Compliance

Parts have undergone strict product testing in order to comply with regulatory standards and specification set by international, independent, and federal authorities.
Products have been approved to carry the following symbol:
natural_image
Black plastic laboratory condenser unit with clear glass lid and ventilation slots (no text or symbols visible)natural_image
Symbol of a trash bin crossed with a diagonal line, no text or numbers presentnatural_image
Black plastic laboratory condenser unit with clear glass panel and ventilation slots (no text or symbols visible)natural_image
Symbol of a trash bin with crossed lines indicating no waste or restriction, and a solid black rectangle below (no text or labels)EU declaration of conformity
Name and address of the manufacturer or his authorised representative:
Scandomestic A/S
Linåvej 20
8600 Silkeborg
Denmark
This declaration of conformity is issued under the sole responsibility of the manufacturer (or installer):
Scandomestic A/S
Linåvej 20
8600 Silkeborg
Denmark
References to the relevant harmonised standards used or references to the other technical specifications in relation to which conformity is declared:
EN ISO 17050-1: 2004
Additional Information
Object of the declaration
(identification of product allowing traceability. It may include a colour image of sufficient clarity to enable the identification of the product)

natural_image
Black and white photo of a glass-walled refrigerator with ventilation slots (no visible text or symbols)| Model number(unique identification of the product): | IMC82BC |
| Type | Impulse Cooler |
| Brand | Scancool |
| Outside colour | Black |
The object of the declaration described above is in conformity with the relevant Union harmonisation legislation:
scandomestic
Denmark · CVR. No.: 29774242
Phone: +45 7242 5571
info@scandomestic.dk

DK
Adgang til professionel reparation, såsom internetsider, adresser, kontaktoplysninger: Model nr.: IMC82BC
Access to professional repair, such as internet webpages, addresses, contact details.
Model no: IMC82BC
Aftersales service station list:
| Address | Linåvej 20 . 8600 Silkeborg . Denmark | QR code | ![]() |
| Contact Number | 0045 7242 5571 | ||
| Website | www.scandomestic.dk | ||
| Relevant information for ordering spare parts, directly or through other channels provided by the manufacturer, importer or authorised representative; | www.scandomestic.dk | ||
| The minimum period during which spare parts, necessary for the repair of the appliance, are available; (years) | 8 | ||
| defined in Regulation EU 2019/2018 by means of a weblink that links to the model information as stored in the product database or a link to the product database and information on how to find the model identifier on the product.) | www.scandomestic.dk | ||
Note: The address or contact phone number of the service site is subject to change without prior notice. Please confirm whether the service station is a directly affiliated one of our company when requiring services.